• Title/Summary/Keyword: Treatment Equipment

Search Result 942, Processing Time 0.034 seconds

Improvement of Blast Efficiency by Correlation Analysis of Impella Blast and Steel Balls for Surface Treatment of Steel Bridges (강교 보수도장의 표면처리를 위한 임펠라 블라스트와 스틸볼의 상관관계 분석을 통한 블라스트 효율 향상)

  • Chang, Byoung Ha;Jang, Dong Wook;Seo, Myoung Kook;Lee, Ho Yeon;Park, Jae Hyun
    • Journal of Drive and Control
    • /
    • v.19 no.1
    • /
    • pp.8-15
    • /
    • 2022
  • The demand for the re-painting of steel bridges is increasing, but surface treatment is still centered on human resources for on-site re-painting processes. Worker safety accidents continue to occur because the work is performed in a narrow space. Recently, PS balls with excellent surface treatment have been used for blasting, but the working environment is poor due to the large amount of dust generated. In this study, an effective surface treatment method using impeller blasting equipment was developed. The correlation between steel ball size, impeller rotation speed, and exposure time was studied to optimize the efficiency of the surface treatment.

The NPS Analysis and CSO Management Based on SWMM for Oncheon Basin (SWMM 모형을 이용한 비점오염 분석 및 CSO 관리방안 연구 - 부산시 온천천 유역 대상 -)

  • Shin, Hyun Suk;Son, Jeong Hwa;Jang, Jong Kyung;Shon, Tae Seok;Kang, Dookee;Cho, Dukjoon
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.2
    • /
    • pp.268-280
    • /
    • 2009
  • Oncheon basin which are located in Busan is divided into 43 basin on the basis of main pipe, constructed with Storm Water Management Model (SWMM). Occurrence situation for Outflow and pollutant loads by long-term continuous rainfall is examined for treatment district and river analysis point of Oncheon basin and a reduction vs effectiveness table for effective CSOs managements is made for each of treatment districts according to each of managements. In case that treatment equipment is located at the discharge point of CSO, treatment efficiency is analysed. It is supposed that treatment equipment have an efficiency on the basis of a concentration and runoff discharge over a critical flow is discharged with it untreated and treating runoff discharge with treatment equipment at each of runoff discharge points and treating it gathered at sewage treatment plant (STP) through trunk sewer is compared for a relative treatment efficiency.

Experimental Study on the Improvement of Surface Treatment of Mechanical Structures in Field Environment (야전 환경에서 기계구조물 표면처리 개선에 관한 실험적 연구)

  • Kim, Jongwha;Hyun, Jonghun;Kang, Seokjoong
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.24 no.2
    • /
    • pp.197-203
    • /
    • 2021
  • Mechanical structures of military equipment have been mainly applied with black oxide coating due to the limitation of surface treatment thickness. However, the mechanical structures applied by the black oxide coating treatment is constantly being corroded by calcium chloride and humidity. Since this can cause serious problems in the operation of equipment, a review to improve surface treatment and corrosion resistance is required. Therefore, in this study, surface treatment methods that can enhance corrosion resistance were selected and corrosion resistance performance was verified through experiments describing harsh field conditions. Thus, applying a proven surface treatment method to future military equipment will prevent corrosion.

Green algae dominance quickly switches to cyanobacteria dominance after nutrient enrichment in greenhouse with high temperature

  • Wang, Xiaodong;Liu, Xingguo;Qin, Boqiang;Gu, Zhaojun;Wu, Zongfan;Xu, Hao;Zhu, Hao;Cheng, Guofeng;Liu, Huang
    • Journal of Ecology and Environment
    • /
    • v.38 no.3
    • /
    • pp.293-305
    • /
    • 2015
  • In order to understand the mechanisms of conversion between different algal dominance, an experiment was performed in a greenhouse from 22 June to 10 July 2011. The experiment included a treatment group subjected to three instances of nutrient enrichment and a control with no nutrient enrichment. The initial water was dominated by Ankistrodesmus of Chlorophyta. The average water temperature at 08:30 h and 14:00 h during the experiment was $31.6^{\circ}C$ and $34.6^{\circ}C$, respectively. The results showed that the total nitrogen (TN), total phosphorus (TP), dissolved total nitrogen (DTN), dissolved total phosphorus (DTP), and soluble reactive phosphorus (SRP) concentrations in the treatment were significantly higher than in the control (P < 0.05). However, the TN/TP and DTN/DTP in the control was higher than in the treatment (P < 0.05). The dominant algae in the control did not change during the experiment, while the dominant algae in the treatment switched to Planktothrix of Cyanophyta on day 9. The chlorophyll a (Chl-a), wet weight of all algae, wet weight of Cyanophyta, and percentage of Cyanophyta in the control were all significantly lower than in the treatment (P < 0.05). Amounts of zooplankton, especially rotifers, were present at the end of the experimental period. The density of rotifers between the control and treatment was not significantly different (P > 0.05), while the copepod density in the treatment was higher than in the control (P < 0.05). We conclude that green algae dominance quickly switches to cyanobacteria dominance after nutrient enrichment in a greenhouse with elevated temperature.

A Study on the Availability Modelling and Assessment with Failure Density Function of Major Equipment for a Sewage Treatment Plant (하수처리장 주요 기자재의 고장확률밀도함수를 이용한 가용도 모델링 및 평가에 관한 연구)

  • Lee, Hong-Cheol;Kwak, Pilljae;Lee, Hyundong;Hwang, In-Ju
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.11
    • /
    • pp.763-768
    • /
    • 2013
  • The simulation investigation on the availability with failure density function of major equipment for a sewage treatment plant has been carried out. This study focuses on the availability of the plant and criticality with equipment module induced by component layout and its failure function. The equipment classification of sewage treatment plant and its failure function are established. Also solution methodologies are introduced as Monte-Carlo simulation method and event algorithm for uncertainty problem. The availability in the case of serial connection of equipment with all exponential function is calculated as around 50.4%. In other case of parallel combination with back up equipment, the availability showed over 80.1%. The criticality that a ffects availability showed high value over 77% in the dehydration and concentration process of sludge.

Development of Controlled Gas Nitriding Furnace(II) : Controlled Gas Nitriding System and its Hardware (질화포텐셜 제어 가스질화로 개발(II) : 제어시스템 및 하드웨어)

  • Won-Beom Lee;Won-Beom Lee;YuJin Moon;BongSoo Kim
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.36 no.2
    • /
    • pp.86-95
    • /
    • 2023
  • This paper explained the equipment and process development to secure the source technology of controlled nitrification technology. The nitriding potential in the furnace was controlled only by adjusting the flow rate of ammonia gas introduced into the furnace. In addition, a control system was introduced to automate the nitriding process. The equipment's hardware was designed to enable controlled nitriding based on the conventional gas nitriding furnace, and an automation device was attached. As a result of measuring the temperature and quality uniformity for the equipment, the temperature and compound uniformity were ±1.2℃ and 14.3 ± 0.2 ㎛, respectively. And, it was confirmed that nitriding potential was controlled within the tolerance range of AMS2759-10B standard. In addition to parts for controlled nitriding, it was applied to products produced in existing conventional nitriding furnaces, and as a result, gas consumption was reduced by up to 80%.

Corrosion Characteristics of Welding Zone by Types of Repair Welding Filler Metals and Post Weld Heat Treatment

  • Lee, Sung-Yul;Moon, Kyung-Man;Lee, Yeon-Chang;Kim, Yun-Hae;Jeong, Jae-Hyun
    • International Journal of Ocean System Engineering
    • /
    • v.2 no.4
    • /
    • pp.209-213
    • /
    • 2012
  • Recently, the fuel using in the diesel engines of marine ships has been changed to a low quality of heavy oil because of the steady increase in the price of oil. Therefore, the wear and corrosion in all parts of the engine such as the cylinder liner, piston crown, and spindle and seat ring of exhaust valves has correspondingly increased. The repair welding of a piston crown is a unique method for prolonging its lifetime from an economic point of view. In this case, filler metals with a high corrosion and wear resistance are mainly being used for repair welding. However, often at a job site on a ship, a piston crown is actually welded with mild filler metals. Therefore, in this study, mild filler metals such as CSF350H, E8000B2, and 435 were welded to SS401 steel as the base metal, and the corrosion properties of the weld metals with and without post weld heat treatment were investigated using some electrochemical methods in a 0.1% $H_2SO_4$ solution. The weld metal welded with CSF350H filler metal exhibited the best corrosion resistance among these filler metals, irrespective of the heat treatment. However, the weld metal zones of the E8000B2 and 435 filler metals exhibited better and worse corrosion resistance with the heat treatment, respectively. As a result, it is suggested that in the case of repair welding with CSF350H and 435 filler metals, no heat treatment is advisable, while heat treatment is desirable if E8000B2filler metal is used with repair welding.

On-Site Treatment of Soil Contaminated by Heavy Metals and Petroleum using Relocatable Soil Washing Equipment

  • Kim, Taeeung
    • International journal of advanced smart convergence
    • /
    • v.9 no.1
    • /
    • pp.19-28
    • /
    • 2020
  • We studied the on-site treatment of soil contaminated by heavy metals and petroleum was tested using relocatable soil washing equipment for greater remediation efficiency. Different combinations of pH and solid/liquid ratio were tested to determine the optimum balance, settling on values of 5 and 1:2, respectively. Next, soils containing Pb, Hg, and petroleum were further tested to assess the optimum number of washing cycles. The remediation efficiency of Pb and Hg in soil contaminated solely by heavy metals was 90.1% and 86.4% after three and two washings, respectively. The remediation efficiency of petroleum in soil contaminated solely by petroleum was 98.8% after one washing. When soil contaminated by both heavy metals and petroleum was cleaned, up to 91.0% of Pb, 86.9% of Hg, and 96.1% of petroleum was removed after two, one, and one washings, respectively. We conducted all remediation efficiencies and concentration reductions satisfied the standard threshold for soil contamination in South Korea.