• 제목/요약/키워드: Treated wastewater

검색결과 591건 처리시간 0.022초

장기폭기시킨 축사뇨오수의 벼재배 시비효과 (The Fertilizing Effect of the Long-Time Aerated Animal Wastewater for the Paddy Rice)

  • 오인환
    • 한국축산시설환경학회지
    • /
    • 제3권1호
    • /
    • pp.35-42
    • /
    • 1997
  • The purpose of this study is to investigate the effect of the biologically treated animal wastewater as a liquid fertilizer in the paddy rice. The treated water has content of the ammonia nitrogen 24mg/I and nitrate 40 mg/I on an average in the first year. A trace of nitrite has been shown. The phosphate content was 92 mg/I on an average. The amount of yielded rice was 365kg/10a for test 1 (no fertilizer), 388dg/10a for test 2(chemical fertilizer), 526kg/10a for test 3 (treated water) respectively. The treated water showed 35% more in production than the chemical fertilizer. The treated water has content of the ammonia nitrogen 40mg/I and nitrate 67mg/I on an average in the second year. A trace of nitrite has been shown. The phosphate content was 57mg/I on an average. The amount of yielded rice was 402kg/10a for test 1, 505kg/10a for test 2, 607kg/10a for test 3 respectively. Yield of unhulled rice was 20% more in the plot of treated water than that of chemical fertilizer.

Evaluation of monthly environmental loads from municipal wastewater treatment plants operation using life cycle assessment

  • Piao, Wenhua;Kim, Ye-jin
    • Environmental Engineering Research
    • /
    • 제21권3호
    • /
    • pp.284-290
    • /
    • 2016
  • Life cycle assessment (LCA) methodology can be used to assess impacts on the environment that might be generated during treatment of wastewater and sludge treatment. In this work, LCA methodology was suggested to evaluate monthly environmental impact of wastewater treatment plants (WWTPs). Two field scale WWTPs, A2/O process and conventional activated sludge process (CAS), were selected as target plants and the operational data were collected from those plants. As the function units, the unit volume of treated wastewater of $1m^3$ and 1 kg T-N eq. removed were selected. The environmental effect of target WWTPs operation were assessed as impact categories such as global warming potential, eutrophication potential, and so on. From monthly profiles of each index, it was shown that the environmental impact of WWTPs has seasonal patterns influenced by the influent flow rate variation causing higher impacts in winter than summer. This is due to the fact that there were no significant increase in the electricity consumption and chemical usage during the summer while the treated volume of wastewater was increased.

하수처리수와 하천수를 대상으로 한 생태적 수질정화 비오톱 시스템의 오염물질 제거에 대한 수질정화 평가 (Evaluation of Pollutants Removal for Treated Wastewater Effluent and River Water by Meandering Constructed Wetland System)

  • 이상호
    • 상하수도학회지
    • /
    • 제26권1호
    • /
    • pp.131-139
    • /
    • 2012
  • Field experiment was performed from June 2010 to July 2011 to evaluate pollutants removal efficiency in the constructed wetland system for the treated wastewater and the river water. The wetland systems were constructed near Gyungan river. Two different systems with meandering shape were compared for seasonal base and operational period base. Several kinds of aquaculture are planted through the corridor of wetland system. Average removal rate of BOD, T-N and T-P for A system were 15.8%, 14.8% and 26.5%, respectively. Average removal rate of BOD, T-N and T-P for C system were 23.5%, 27.8% and 10.6%, respectively. The effluent from two wetland systems often exceeded effluent water quality standards for wastewater influent, however effluent water quality standards for river water. However, the wetland system can be useful to treat polluted river water and effluent from wastewater plant. Removal rate of pollutants in seasonal variation was the highest in summer for BOD and T-N, however the removal rates of T-P were higher in spring and autumn than in summer.

백운석 첨가가 응집에 의한 하수 처리수의 인 제거에 미치는 영향 (Effects of dolomite addition on phosphorus removal by chemical coagulation of secondary treated effluent)

  • 이병하;박준홍;차호영;맹승규;송경근
    • 상하수도학회지
    • /
    • 제26권3호
    • /
    • pp.443-451
    • /
    • 2012
  • Wastewater treatment plants need to reduce phosphorus in order to meet increasingly stringent regulations on phosphorus. This study evaluated the feasibility of dolomite as a coagulation aid to enhance phosphorus removal from secondary treated wastewater by chemical coagulation. Standard jar tests were conducted to evaluate the effect of dolomite addition on a coagulation process for phosphorus removal and to determine the optimum doses of coagulants and dolomite. Coagulants used with dolomite yielded a significant improvement in phosphorus removal and reduced total phosphorus concentrations below 0.02 mg/L in wastewater effluent. Dolomite has played an important role in enhancing phosphate adsorption and increasing pH, as a coagulation aid. The maximum removal efficiency of phosphorus in this study was yielded at 25 mg/l of dolomite and 20 mg Al/L of PAC dose. However, considering economic aspects, the optimum doses of dolomite and PAC were 10 mg/L and 15mg Al/L, respectively. Consequently, dolomite, a coagulation aid, can be used in coagulation processes to enhance the removal of phosphorus.

하수처리장 방류수를 이용한 소수력발전 성능분석 (Performance Anaysis of Small Hydropower Plant Using Treated Effluent in Wastewater Treatment Plant)

  • 이철형;박완순
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.494-497
    • /
    • 2012
  • A methodology to predict the output performance of small hydro power using treated effluent in wastewater treatment plant has been studied. Existing plant located Kyunggi-Do were selected and the output performance characteristics for these plants were analyzed. As a result, it was found that the developed model in this study can be used to analyze the output characteristics for small hydro power in wastewater treatment plant. Additionally, primary design specifications such as design flowrate, capacity, operational rate and annual electricity production were estimated and discussed.

  • PDF

침지형 한외여과 막공법과 역삼투 공법을 이용한 하.폐수처리 (Wastewater Treatment Using Ultrafiltration (UF) and Reverse Osmosis (RO) Process)

  • 최희정;박연종;이승목
    • 대한환경공학회지
    • /
    • 제34권10호
    • /
    • pp.678-683
    • /
    • 2012
  • 세계적인 물부족을 해결하는 대안 중의 하나는 하수 재이용이다. 본 연구는 A시의 하수를 UF와 RO 공법으로 처리하여 인근지역의 공업용수로 재사용이 가능한지의 여부를 확인하고자 하였다. A시의 하수를 UF와 RO로 처리한 결과 Na, Mg, Cl, Ca, Mn, $PO_4$, $SO_4$ 등은 원수 대비 97% 이상의 높은 처리 효율을 보였으나, $NH_4$-N, TN, $NO_3$-N, BOD등의 영양염류는 각각 35.71%, 85.21%, 87.05% 그리고 56%로 상대적으로 낮은 제거율을 보였다. 그러나 영양염류는 원수 자체의 함유량이 소량 이여서 하수 처리수 공업용수 재이용수질 권고 기준을 만족하는데 문제가 없었다. 그 외의 측정항목 또한 하수 처리수 공업용수 재이용수질 권고 기준을 만족하여 인근지역의 공업용수로 재사용에는 문제가 없을 것으로 예상된다.

하수처리수의 논 관개용수 재이용을 위한 미생물 위해성 평가 (Quantitative Microbial Risk Assessment of Wastewater Reuse for Irrigation in Paddy Field)

  • 윤춘경;한정윤;정광욱;장재호
    • 한국농공학회논문집
    • /
    • 제48권2호
    • /
    • pp.77-87
    • /
    • 2006
  • The reuse of wastewater for agricultural irrigation may cause human health risk as a result of exposure to pathogens. This study conducted the quantitative microbial risk assessment in paddy field irrigated with treated wastewater. Six treatments were used to irrigate the paddy field from Year 2003 to Year 2005: biofilter-effluent, UV-disinfected water (6, 16, 40, 68 $mW s cm^{-2}$), pond-treated water, wetland-treated water, conventional irrigation water and tap water. Total coliforms, fecal coliforms and E. coli were monitored during rice growing period. Beta - Poisson model was employed to calculate the microbial risk of pathogens ingestion that may occur to farmers and neighbor children. Uncertainty of risk was estimated using Monte Carlo simulation. In this study, the microbial risk was higher during initial cultivation (end of May$\sim$June), and it decreased with time. Biofilter effluent (secondary effluent) irrigation showed higher risk values than others (>$10^{-4}$) and irrigation with UV-disinfected water has the lowest risk range ($10^{-6}{\sim}10^{-5}$). The risk value estimated in 2005 was lower than risk value in 2003 and 2004, it is likely due to clean tap water irrigation in initial transplanting stage. It is suggested that irrigation with UV-disinfected water and pond-treated water would reduce the microbial risk associated with wastewater irrigation in paddy field. In addition, the first irrigation water quality significantly affected the subsequent microbial risk.

하수방류수 재이용을 위한 Birm filter + UF 적용시 용도별 사용 가능성 및 막오염 특성 (Possible Uses of Reclaimed Wastewater Effluent Treated Using Birm Filtration Along UF, and Analysis on Membrane Fouling)

  • 정진희;이승철;성낙창;최영익
    • 한국환경과학회지
    • /
    • 제25권11호
    • /
    • pp.1467-1474
    • /
    • 2016
  • In response to the water shortage problem, continued attempts are being made to secure consistent and reliable water sources. Among various solutions to this problem, wastewater effluent is an easy way to secure the necessary supply, since its annual output is consistent. Furthermore, wastewater effluent has the advantage of being able to serve various purposes, such as cleaning, sprinkling, landscaping, river management, irrigation, and industrial applications. Therefore, this study presents the possible use of reclaimed industrial wastewater treated with Birm filters and a UF membrane, along with an analysis on membrane fouling. The preprocessing stage, part of the reclamation process, used Birm filters to minimize membrane fouling. Since this study did not consider heavy metal levels in the treated water, the analyses did not include the criterion for irrigation water quality. However, the wastewater reclaimed by using Birm filters and a UF membrane met every other requirement for reclaimed water quality standards. This indicated that the treated water could be used for cleaning, channel flow for maintenance, recreational purposes, and industrial applications. The analysis on the fouling of the Birm filter and UF membrane required the study of the composition and recovery rate of the membrane. According to SEM and EDX analyses of the UF membrane, carbon and oxygen ion composition amounted to approximately 57%, whereas inorganic matter was not detected. Furthermore, the difference in the recovery rates of the distressed membrane between acidic and alkaline cleaning was more than ~78%, which indicated that organic rather than inorganic matter contributed to membrane fouling.

수중 미량 잔류항생물질 Erythromycin, Sulfamethazine, Sulfathiazole의 오존산화제거 (Removal of Residual Antibiotics - Erythromycin, Sulfamethazine and Sulfathiazole - from water by Ozone Oxidation)

  • 최연우;한민수;송준혁;왕창근
    • 상하수도학회지
    • /
    • 제31권4호
    • /
    • pp.347-356
    • /
    • 2017
  • Oxidation of erythromycin, sulfamethazine and sulfathiazole by ozone was experimentally investigated to see the effects of background water quality such as ultrapure water, humic acid and biologically treated wastewater and water temperature on the removal rate, consequently to provide design information when the ozone treatment process is adopted. Initial concentration of the antibiotics was spiked to $10{\mu}g/l$ and ozone dose was 1, 2, 3, 5, 8 mg/l. While the removal rate of erythromycin under ultrapure water background by ozone oxidation was over 99%, that under humic acid and biologically treated wastewater background was markedly reduced to the range of 59.8%~99% and 17.0%~99%, respectively. When water temperature is decreased from $20^{\circ}C$ to $4^{\circ}C$, the removal rate is reduced from the range of 17.0%~99% to the range of 9.4%~97.4% under biologically treated wastewater background. The effects of background and temperature on the removal rate of sulfamethazine and sulfathiazole were similar to erythromycin, but the degree was different. Therefore, it is concluded that the background of water to be treated as well as water temperature should be taken into consideration when the design factor such as ozone dose is determined to meet the treatment objective in the ozone treatment process.

공공하수처리시설 방류수 TOC에 영향을 주는 요인 분석 (Analysis of factors affecting effluent TOC in publicly owned treatment works)

  • 강성주;강병준;박규홍;정동환;이원석;정현미
    • 상하수도학회지
    • /
    • 제33권2호
    • /
    • pp.141-150
    • /
    • 2019
  • Total organic carbon(TOC) was introduced as the water quality index of the rivers and lakes in 2013. This paper evaluated factors affecting effluent TOC concentrations and treated and discharged loads of existing publicly owned treatment works(POTWs). For selected POTWs with greater treatment capacity than $500m^3/day$, factorial analysis was used to consider effects of kinds of biological treatment processes, inflow of other types of wastewater(industrial, livestock, landfill leachate wastewater, etc.) with domestic wastewater, sewer separation rate, and effluent discharging zones in which different effluent criteria applied. As a result, those factors did not show significant effect on effluent TOC concentration of POTWs in effluent discharging zone I and II. However, In effluent discharging zone III and IV, kinds of biological treatment processes, the inclusion of other waste in influent of domestic wastewater, and the sewer separation rate were significant factors. The treated TOC load in POTWs was also not affected significantly by the variables set in this study. On the other hand, those three factors influenced significantly on the TOC load discharged to water bodies. The sum of factorial effects and the contribution rate of three factors to the discharged TOC load was 60.23 and 41%, 59.57 and 41%, and 42.04 and 18%, respectively.