• Title/Summary/Keyword: Trap system

Search Result 309, Processing Time 0.028 seconds

Effects of Cattle Manure and Swine Slurry Acidification on Ammonia Emission as Estimated by an Acid Trap System

  • Park, Sang-Hyun;Lee, Bok-Rye;Kim, Tae-Hwan
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.35 no.3
    • /
    • pp.212-216
    • /
    • 2015
  • This study was conducted to assess the efficacy of slurry acidification in reducing ammonia emission from manure storage and application. The non-fermented cattle manure (NFC) and swine slurry (SS) were acidified by sulfuric acid and stored in an acryl chamber for 168 and 96 hours, respectively. Ammonia emitted from the chamber was collected using an acid trap system. The amount of ammonia emission was significantly reduced when the livestock manures were treated with sulfuric acid. The absolute amount of ammonia in NFC increased rapidly starting from 48 h and 72 h in the control (pH 8.6) and acidified NFC (pH 6.5), respectively. The absolute amount of ammonia was the highest at 96 h ($3.65g\;kg^{-1}h^{-1}$) in the control and at 144 h ($2.34g\;kg^{-1}h^{-1}$) in pH 6.5 NFC. The cumulative ammonia content in the control continuously increased until 96 h and was maintained until 168 h, whereas the increase rate of emission gas accumulation in acidified NFC was much less throughout the experimental period. Acidification of SS mitigated ammonia emission as proven in NFC. The cumulative amount of ammonia emission was decreased by 49.4% and 92.3% in the acidified SS at pH 6.5 and pH 5.5, respectively, compared to the control at 96 h after treatment. These results indicate that ammonia emission can be significantly reduced by sulfuric acid treatment of livestock manure during processing and the subsequent land application.

Molecular Analysis of Rice Plants Harboring an Ac/Ds Transposable Element-Mediated Gene Trapping System

  • Hang Gyeong;Mi Sook Choe;Sung-Ho Lee;Sung Han Park;Hyuk Kim;Ja Choon Koo;No Youl Kim;Su Hyun Park;Jeung Joo Lee
    • Proceedings of the Botanical Society of Korea Conference
    • /
    • 1999.07a
    • /
    • pp.17-20
    • /
    • 1999
  • In rice, limited efforts have been made to identify genes by the use of insertional mutagens, especially heterologous transposons such as the maize Ac/Ds. We constructed Ac and gene trap Ds vectors and introduced them into the rice genome by Agrobacterium-mediated transformation. In this report, rice plants that contained single and simple insertions of T-DNA were analyzed in order to evaluate the gene-tagging efficiency. The 3'end of Ds was examined for putative splicing donor sites. As observed in maize, three splice donor sites were identified at the 3'end of the Ds in rice. Nearly 80% of Ds elements wered excised from the original T-DNA sites, when Ac cDNA was expressed under a CaMV 35S promoter. Repetitive ratoon culturing was performed to induce new transpositions of Ds in new plants derived from cuttings. About 30% of the plants carried at least one Ds that underwent secondary transposition in the later cultures. 8% of transposed Ds elements expressed GUS in various tissues of rice panicles. With cloned DNA adjacent to Ds, the genomic complexities of the insertion sites were examined by Southern hybridization. Half of the Ds insertion sites showed simple hybriodization patterns which could be easily utilized to locate the Ds. Our data demonstrate that the Ac/Ds mediated gene trap system could prove an excellent tool for the analysis of functions of genes in rice. We discuss genetic strategies that could be employed in a largee scale mutagenesis using a heterologous Ac/Ds family in rice.

  • PDF

Air Sampling For Volatile Organics Using an Adsorbent (흡착제를 이용한 휘발성 유기물 채취)

  • ;L.R.Berrafato
    • Journal of Environmental Science International
    • /
    • v.1 no.1
    • /
    • pp.41-46
    • /
    • 1992
  • To perform a long-term ambient sampling study at a residential site, an air sampler was constructed to collect 24-hour integrated air samples suitable for the volatile organic compounds (VOCs) analysis. It includes an esthetically acceptance due to proximity to homes, as fell as providing the required sampling specifications. The VOCs sampler accomodates four 5/8 "stainless steel(SS) traps packed with adsorbent(Tenax) and is capable of four flow rates in the range of 5 to 50 cc/min. Sintered metal filters(10 micrometer) were directly connected to the inlet of the trap adapters. Additional specifications include: 1) constructed of organically inert materials, 2) weatherproof, 3) battery operated, 4) collecting of VOCs at a breathing zone level, and 5) quiet operation with micro diaphragm pumps wrapped by the sponge. The pump/battery system was separated from the sampling shelter. Sound levels measured for this system were below permissible sound levels (NJDEP) at a residential site. The sampler has been successfully operated at both ground level in a residential area and on the roof of a one story elementary school.hool.

  • PDF

Development of a Total Internal Reflection Fluorescence (TIRF) Microscopy for Precise Imaging the Drying Pattern of a Sessile Droplet (고착 액적 증발면의 정밀 관측을 위한 전반사 형광 현미경 기법 개발)

  • Wonho Cho;Jinkee Lee
    • Journal of the Korean Society of Visualization
    • /
    • v.21 no.3
    • /
    • pp.65-74
    • /
    • 2023
  • Compared to epifluorescence(EPI) microscopy which captures fluorescence from the entire depth of sample, total internal reflection fluorescence(TIRF) can selectively visualize only a single surface of it. TIRF uses a thin evanescent field generated by the total internal reflection of laser light on surface. However, conventional TIRF system are designed for total internal reflection to occur at the upper surface of sample, making them unsuitable for sessile droplet imaging. We designed a TIRF system suitable for a sessile droplet imaging by utilizing slide glass as a lightguide. We presented the details for constructing the TIRF system using a prism, slide glass, air slit, and optical trap. Then, we compared the TIRF with EPI by imaging the droplet with fluorescent particles during its drying process. As a result, TIRF allows us to distinctly visualize the drying pattern on the bottom surface of droplet.

Characteristics of Simultaneous Removal of NOx and PM over a Hybrid System of LNT/DPF + SCR/DPF in a Single Cylinder Diesel Engine (단기통 디젤엔진에서 LNT/DPF + SCR/DPF 하이브리드 시스템의 NOx 및 PM 동시저감 특성)

  • Kang, Wooseok;Park, Su Han;Choi, Byungchul
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.24 no.2
    • /
    • pp.152-160
    • /
    • 2016
  • The market demand for diesel engine tends to increase in general passenger cars as well as commercial vehicles because of its advantages. However, to meet the vehicle emissions regulation which will be more stringent in the future, it is necessary to plurally apply all after-treatment technologies such as diesel oxidation catalyst (DOC), catalyzed diesel particulate filter (CDPF), lean NOx trap (LNT) and selective catalytic reduction (SCR), and so on. Accordingly, the exhaust after-treatment system for diesel vehicle requires the technology of minimizing the numbers of catalysts by integrating every individual catalysts. The purposes of this study is to develop hybrid exhaust after-treatment device system which simultaneously uses LNT/DPF and SCR/DPF catalyst concurrently reducing NOx and particulate matter (PM). As the results, the hybrid system with $NH_3$ generated at LNT/DPF working as a reducing agent of SCR/DPF catalyst, improving NOx conversion rate, was found to be more excellent in de-NOx performance than that in LNT/DPF alone system.

Self-sustainable Operation of a 1kW class SOFC System (1kW급 고체산화물 연료전지 발전시스템 자열운전)

  • Lee, Tae-Hee;Choi, Jin-Hyeok;Park, Tae-Sung;Yoo, Young-Sung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.57-60
    • /
    • 2008
  • KEPRI has studied planar type SOFC stacks using anode-supported single cells and kW class co-generation systems for residential power generation. A 1kW class SOFC system consisted of a hot box part, a cold BOP part and a water reservoir. A hot box part contains a SOFC stack made up of 48 single cells and ferritic stainless steel interconnectors, a fuel reformer, a catalytic combustor and heat exchangers. Thermal management and insulation system were especially designed for self-sustainable operation. A cold BOP part was composed of blowers, pumps, a water trap and system control units. When a 1kW class SOFC system was operated at $750^{\circ}C$ with hydrogen after pre-treatment process, the stack power was 1.2kW at 30 A and 1.6kW at 50A. Turning off an electric furnace, the SOFC system was operated using hydrogen and city gas without any external heat source. Under self-sustainable operation conditions, the stack power was about 1.3kW with hydrogen and 1.2kW with city gas respectively. The system also recuperated heat of about 1.1kW by making hot water.

  • PDF

Operation Results of the SOFC System Using 2 Sub-Module Stacks (2 모듈 스택을 이용한 SOFC 시스템 운전결과)

  • Lee, Tae-Hee
    • Journal of Hydrogen and New Energy
    • /
    • v.21 no.5
    • /
    • pp.405-411
    • /
    • 2010
  • A 5kW class SOFC cogeneration system consisted of a hot box part, a cold BOP (balance of plant) part, and a hot water reservoir. The hot box part contained a stack, a fuel reformer, a catalytic combustor, and heat exchangers. A cold BOP part was composed of blowers, pumps, a water trap, and system control units. A 5kW stack was designed to integrate 2 sub-modules. In this paper, the 5kW class SOFC system was operated using 2 short stacks connected in parallel to test the sub-module and the system. A short stack had 15 cells with $15{\times}15 cm^2$ area. When a natural gas was used, the total power was about 1.38 kW at 120A. Because the sub-modules were connected in parallel and current was loaded using a DC load, voltages of sub-modules were same and the currents were distributed according to the resistance of sub-modules. The voltage of the first stack was 11.46 V at 61A and the voltage of the second stack was 11.49V at 59A.

고농도 Out Gas 정량 분석법 개발

  • Kim, Min-Ju;Kim, Jong-Yun;Jeong, Gi-Ho;Park, Chang-Sik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.13-13
    • /
    • 2009
  • 본 연구는 MLCC 구성성분의 증발/비등에 의한 저분자물질의 제거가 bar 수축에 미치는 영향도를 평가하기 위해, 압착 bar에서 발생하는 고농도의 out gas를 정량하기 위한 최적 system을 구축하고자 하였다. gas 포집에 범용적으로 사용하는 Purge & Trap sampler 대신 Heating block를 사용하여 gas를 발생시키고 동시에 solvent에 용해시킴으로써 고농도의 시료가 희석될 수 있는 전처리 장치를 디자인하였다. 그 결과 고농도 gas 주입에 의한 장비오염과 peak saturation 문제가 해결되었고, gas phase의 시료를 liquid phase로 상전이 시켜 autosampler를 이용한 정확한 량의 시료 주입이 가능하였다. System의 Gage Linearity와 Bias는 각각 1.7%와 1.3%로 개선이 필요없는 수준의 정확도를 가졌다.

  • PDF

A Study on the Performance of the Diesel Particulate Filter made of Porous Metal with Fe-based Fuel Additive (Fe 첨가제를 적용한 금속분말 필터의 포집 및 재생 특성에 관한 연구)

  • Park, S.H.;Chun, K.M.;Cho, G.B.;Jeong, Y.I.;Park, Y.L.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.802-806
    • /
    • 2001
  • Diesel particulate trap is the most reliable system to reduce the particulate matters from diesel engine. Filter is the core component of DPF and ceramic monolith type is dominantly used, which is expensive and fragile relatively at thermal shock. Porous metal filter, which has superior thermal characteristics and low cost, was tested in order to analyze the regeneration performance by using with ferrocene additive. This filter showed the 72% filtration efficiency, additives itself diminished 48% of PM from engine out emission, and final PM reduction ratio of 89% was achieved by DPF system with D-13 test mode.

  • PDF

Production of Shikonin by A Hairy Root Culture of Lithospermum erythrorhizon

  • Seo, Weon-Taek;Park, Young-Hoon;Choe, Tae-Boo
    • Journal of Microbiology and Biotechnology
    • /
    • v.2 no.1
    • /
    • pp.41-45
    • /
    • 1992
  • Shikonin production was examined in a bubble column bioreactor system with the hairy roots of Lithosphermum erythrorhizon. The volumetric productivity was higher than those obtained from other reactor configurations with free or immobilized cells of the same cell line. The productivities of the bubble column reactor, with and without a product absorption trap, were 7.4 and 4.5 mg of shikonin/l/d, respectively. This indicated the importance of the product removal in the design and operation of the shikonin production system with hairy root culture.

  • PDF