• Title/Summary/Keyword: Transthoracic Ultrasound

Search Result 6, Processing Time 0.018 seconds

Postoperative Transesophageal Echocardiographic Evaluation in Patients with Cardiac Valve Replacement (경식도 심초음파 검사를 이용한 판막대치술 환자의 평가)

  • 조건현
    • Journal of Chest Surgery
    • /
    • v.24 no.3
    • /
    • pp.265-270
    • /
    • 1991
  • Since advent of the prosthetic cardiac valve replacement, much efforts for accurate assessing value function in-vivo have been attempted. To evaluate the postoperative functional and morphological status of the replaced cardiac valve prosthesis, 33 patients with valve replacement were studied by transthoracic and transesophageal 2-dimensional echocardiac imaging as well as by color Doppler flow velocity imaging. Twenty four patients had mitral valve replacement. 6 patients had aortic valve replacement and 3 patients had both mitral and aortic valve replacement. There were 34 mechanical and 2 biological prosthesis. Comparing to transthoracic echocardiography, transesophageal approach showed transvalvular regurgitant jet flow amid the prosthetic mitral valve ring during. systole and much clear visualization of cardiac chamber behind prosthesis which could give shadowing effect to ultrasound beam. According to the quantitative grading by the length and area of mitral regurgitant flow, 24 out of 27 mitral valves revealed mild degree regurgitation considered as physiological after prosthetic bileaflet valve replacement and the other 3 valves including 2 biological prosthesis had moderate degree regurgitation which was regarded as pathologic one. 2 cases of left atrial thromboses and 1 case of paravalvular leakage which were not visible by transthoracic approach were identified by transesophageal echocardiography in patients with mitral valve replacement and patients with aortic valve replacement respectively. We conclude that in patients with prosthetic mitral valve replacement, transesophageal 2-dimensional imaging with color Doppler can suggest reliable information beyond that available from the transthoracic access even though it gives patient some discomfort to proceed.

  • PDF

Role of Bedside Ultrasonography in Assessment of Diaphragm Function as a Predictor of Success of Weaning in Mechanically Ventilated Patients

  • Elshazly, Mostafa Ibrahim;Kamel, Khaled Mahmoud;Elkorashy, Reem Ibrahim;Ismail, Mohamed Said;Ismail, Jumana Hesham;Assal, Hebatallah Hany
    • Tuberculosis and Respiratory Diseases
    • /
    • v.83 no.4
    • /
    • pp.295-302
    • /
    • 2020
  • Background: Weaning failure is common in mechanically ventilated patients, and if ultrasound can predict weaning outcome remains controversial. The purpose of this study was to evaluate the diaphragmatic function (thickness and excursion) measured by ultrasound as a predictor of the extubation outcome. Methods: We included 62 mechanically ventilated patients from the chest intensive care unit in this study. Sixty-two patients who successfully passed the spontaneous breathing trial (SBT) were enrolled. The transthoracic ultrasound of the diaphragm was performed during an SBT to the assess diaphragmatic function (excursion and thickness), and they were classified into the successful extubation group and the failed extubation group. Results: There was a statistically significant increase in the successful extubation group in the diaphragmatic excursion and thickness fraction (p<0.001), a statistically significant negative correlation between the diaphragmatic function and the duration of the mechanical ventilation, and a statistically significant negative correlation between the diaphragmatic excursion and the Acute Physiology and Chronic Health Evaluation II. The diaphragmatic excursion cut-off value predictive of weaning was 1.25 cm, with a specificity of 82.1% and a sensitivity of 97.1% respectively, and the diaphragmatic thickness cut-off value predictive of weaning was 21.5%, with a specificity of 60.7% and a sensitivity of 91.2%, respectively. Conclusion: The diaphragmatic ultrasonography was found to be a promising tool for predicting the extubation outcome for mechanically ventilated patients.

Ultrasound-Guided Posterolateral Approach for Midline Calcified Thoracic Disc Herniation

  • Tan, Lee A.;Lopes, Demetrius K.;Fontes, Ricardo B.V.
    • Journal of Korean Neurosurgical Society
    • /
    • v.55 no.6
    • /
    • pp.383-386
    • /
    • 2014
  • Objective : Symptomatic thoracic disc herniation often requires prompt surgical treatment to prevent neurological deterioration and permanent deficits. Anterior approaches offer direct visualization and access to the herniated disc and anterior dura but require access surgeons and are often associated with considerable postoperative pain and pulmonary complications. A disadvantage with using posterior approaches in the setting of central calcified thoracic disc herniation however, has been the limited visualization of anterior dura and difficulty to accurately assess the extent of decompression. Methods : We report our experience with intraoperative ultrasound (US) guidance during a modified posterior transpedicular approach for removal of a central calcified thoracic disc herniation with a review of pertinent literature. Results : The herniated thoracic disc was successfully removed with posterior approach with the aid of intraoperative US. The patient had significant neurological improvement at three months follow-up. Conclusion : Intraoperative ultrasound is a simple yet valuable tool for real-time imaging during transpedicular thoracic discectomy. Visualization provided by intraoperative US increases the safety profile of posterior approaches and may make thoracotomy unnecessary in a selected group of patients, especially when a patient has existing pulmonary disease or is otherwise not medically fit for the transthoracic approach.

Echocardiographic parameters and indices in 23 healthy Maltese dogs

  • Tsai, Chih-Hung;Huang, Chao-Chun;Ho, Chia-Chi;Claretti, Marta
    • Journal of Veterinary Science
    • /
    • v.22 no.5
    • /
    • pp.60.1-60.9
    • /
    • 2021
  • Background: Echocardiography is a primary tool used by veterinarians to evaluate heart diseases. In recent years, various studies have targeted standard echocardiographic values for different breeds. Reference data are currently lacking in Maltese dogs and it is important to fill this gap as this breed is predisposed to myxomatous mitral valve disease, which is a volume overload disease. Objectives: To establish the normal echocardiographic parameters for Maltese dogs. Methods: In total, 23 healthy Maltese dogs were involved in this study. Blood pressure measurements, thoracic radiography, and complete transthoracic echocardiography were performed. The effects of body weight, age and sex were evaluated, and the correlations between weight and linear and volumetric dimensions were calculated by regression analysis. Results: The mean vertebral heart size was 9.1 ± 0.4. Aside from the ejection fraction, fractional shortening, and the left atrial to aorta root ratio, all the other echocardiographic parameters were significantly correlated with weight. Conclusion: This study describes normal echocardiographic parameters that may be useful in the echocardiographic evaluation of Maltese dogs.

Clinical Utility of Chest Sonography in Chronic Obstructive Pulmonary Disease Patients Focusing on Diaphragmatic Measurements

  • Hend M. Esmaeel;Kamal A. Atta;Safiya Khalaf;Doaa Gadallah
    • Tuberculosis and Respiratory Diseases
    • /
    • v.87 no.1
    • /
    • pp.80-90
    • /
    • 2024
  • Background: There are many methods of evaluating diaphragmatic function, including trans-diaphragmatic pressure measurements, which are considered the key rule of diagnosis. We studied the clinical usefulness of chest ultrasonography in evaluating stable chronic obstructive pulmonary disease (COPD) patients and those in exacerbation, focusing on diaphragmatic measurements and their correlation with spirometry and other clinical parameters. Methods: In a prospective case-control study, we enrolled 100 COPD patients divided into 40 stable COPD patients and 60 patients with exacerbation. The analysis included 20 age-matched controls. In addition to the clinical assessment of the study population, radiological evaluation included chest radiographs and chest computed tomography. Transthoracic ultrasonography (TUS) was performed for all included subjects. Results: Multiple A lines (more than 3) were more frequent in COPD exacerbation than in stable patients, as was the case for B-lines. TUS significantly showed high specificity, negative predictive value, positive predictive value, and accuracy in detecting pleural effusion, consolidation, pneumothorax, and lung mass. Diaphragmatic measurements were significantly lower among stable COPD subjects than healthy controls. Diaphragmatic thickness and excursion displayed a significant negative correlation with body mass index and the dyspnea scale, and a positive correlation with spirometry measures. Patients in Global Initiative for Chronic Obstructive Lung Disease (GOLD) group D showed lower diaphragmatic measurements (thickness and excursion). Conclusion: The TUS of COPD patients both in stable and exacerbated conditions and the assessment of diaphragm excursion and thickness by TUS in COPD patients and their correlations to disease-related factors proved informative and paved the way for the better management of COPD patients.

Analysis of the Result and Merit of Computed Tomography Guided Percutaneous Needle Aspiration Biopsy of Focal Lung Lesion (CT 유도하 국소적 폐질환의 경피적 흡입생검의 장점과 결과 분석)

  • Chang, You-Song;Cho, Kil-Ho;Byun, Woo-Mock;Hwang, Mi-Soo;Park, Bok-Hwan
    • Journal of Yeungnam Medical Science
    • /
    • v.10 no.1
    • /
    • pp.127-134
    • /
    • 1993
  • Percutaneous needle biopsy of pulmonary lesion with use of fluoroscopic guidance is well established as a diagnostic tool but limited by the small size and inaccessibility of certain lesions. However, percutaneous needle biopsy has been used increasingly in relation to advance and the safty of smaller biopsy needle and new imaging modalities such as ultrasound and CT. CT, because of its characteristics of high resolution, allows tissue sampling with considerable safety from area that heretofore could not be visualized under fluoroscopy. The authors summarized 44 pulmonary lesions that underwent CT-guided transthoracic biopsy with fine-needle over a 14 month period and analyzed the sensitivity of PTNB. CT-guided PTNB was done with 20 gauge or 22 gauge Westcott biopoy needle(Manan medical products, USA). A diagnosis was made in 27 of 44 cases(61%) including malignany in 19 of 24 cases and benignancy in 8 of 20 cases. The pulmonary mass lesions were located at the peripheral zone of the lung field in 33 cases and at the central zone in 11 cases. Complications were observed in 2 cases which were pneumothorax and hemoptysis each but specific therapy was not required. The sensitivity of PTNB by one session was 61%(27/44). The sensitivity of malignancy was 79%(19/24) and benignancy was 40%(8/20). These results suggest the usefulness of PTNB using fine needles be increased in earlier diagnosis and improved staging of pulmonary nodular lesions without significant complications.

  • PDF