• Title/Summary/Keyword: Transport temperature

Search Result 1,512, Processing Time 0.029 seconds

Improvement of carrier transport in silicon MOSFETs by using h-BN decorated dielectric

  • Liu, Xiaochi;Hwang, Euyheon;Yoo, Won Jong
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2013.05a
    • /
    • pp.97-97
    • /
    • 2013
  • We present a comprehensive study on the integration of h-BN with silicon MOSFET. Temperature dependent mobility modeling is used to discern the effects of top-gate dielectric on carrier transport and identify limiting factors of the system. The result indicates that coulomb scattering and surface roughness scattering are the dominant scattering mechanisms for silicon MOSFETs at relatively low temperature. Interposing a layer of h-BN between $SiO_2$ and Si effectively weakens coulomb scattering by separating carriers in the silicon inversion layer from the charged centers as 2-dimensional h-BN is relatively inert and is expected to be free of dangling bonds or surface charge traps owing to the strong, in-plane, ionic bonding of the planar hexagonal lattice structure, thus leading to a significant improvement in mobility relative to undecorated system. Furthermore, the atomically planar surface of h-BN also suppresses surface roughness scattering in this Si MOSFET system, resulting in a monotonously increasing mobility curve along with gate voltage, which is different from the traditional one with a extremum in a certain voltage. Alternatively, high-k dielectrics can lead to enhanced transport properties through dielectric screening. Modeling indicates that we can achieve even higher mobility by using h-BN decorated $HfO_2$ as gate dielectric in silicon MOSFETs instead of h-BN decorated $SiO_2$.

  • PDF

Mass Transfer and Heat Transfer Characteristics of PEM fuel cell by Permeability of GDL (GDL Permeability에 따른 고분자 전해질 연료전지의 물질전달 및 열전달 특성에 관한 연구)

  • Han, Sang-Seok;Lee, Pil-Hyong;Park, Chang-Soo;Lee, Jae-Young;Hwang, Sang-Soon
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2822-2827
    • /
    • 2008
  • Among the main components of PEM fuel cell, the functions of GDL are to transport reactants from the channel to the catalyst and remove reaction products from the catalyst and transport heat from the catalyst to the channels in the flow filed plate. Permeability of GDL is known to make it possible to enhance the gas transport through GDL, devoting to get better performance. In this paper, three dimensional numerical simulation of the fuel cell by the permeability of GDL is presented by using a FLUENT modified to include the electrochemical behavior. Results show that as permeability is higher than $10^{-12}m^2$, gradients of temperature distribution, oxygen molar concentration and current density distribution in MEA were decreased. Although heat generation was increased as high permeability, MEA's temperature was lower than the low permeability of GDL. This seems because that convection was higher affects in mass and heat transfer process than diffusion as permeability of GDL is increases.

  • PDF

Annealing Temperature of Nickel Oxide Hole Transport Layer for p-i-n Inverted Perovskite Solar Cells (P-I-N 역구조 페로브스카이트 태양전지 응용을 위한 Nickel oxide 홀전달층의 열처리 온도 연구)

  • Gisung Kim;Mijoung Kim;Hyojung Kim;JungYup Yang
    • Current Photovoltaic Research
    • /
    • v.11 no.4
    • /
    • pp.103-107
    • /
    • 2023
  • A Nickel oxide (NiOx) thin films were prepared via sol-gel process on a transparent conductive oxide glass substrate. The NiOx thin films were spin-coated in ambient air and subsequently annealed for 30 minutes at temperatures ranging from 150℃ to 450℃. The structural and optical characteristics of the NiOx thin films annealed at various temperatures were measured using X-ray diffraction, field emission scanning electron microscopy, and ultraviolet-visible spectroscopy. After optimizing the NiOx coating conditions, perovskite solar cells were fabricated with p-i-n inverted structure, and its photovoltaic performance was evaluated. NiOx thin films annealed at 350℃ exhibited the most favorable characteristics as a hole transport layer, resulting in the highest power conversion efficiency of 17.88 % when fabricating inverted perovskite solar cells using this film.

Measuring stress responses using active biotelemetry in cattle II. Fluid administration for reducing transport stress (Active biotelemetry를 이용한 젖소의 스트레스 반응 측정: II. 수송 스트레스 감소를 위한 수액투여 효과)

  • Lee, Su-han;Lee, Byeong-han;Lim, Joa-jin;Kim, Jin-young;Lee, Dong-hee;Kim, Jae-kyung;Choe, Nong-hoon;Jeong, Soon-wuk;Chung, Byung-hyun
    • Korean Journal of Veterinary Research
    • /
    • v.41 no.4
    • /
    • pp.603-609
    • /
    • 2001
  • A transport stress is one of the main causes of economic losses and physiological dysfunction. The present study has been performed to suggest a method to decrease the adverse effects above mentioned from transport. The groups were prepared as follows; (1) Control group : 4 cattle transported for 5 hrs (274 km) without any treatment, (2) Treatment group : 4 cattle treated with electrolyte-mineral solution (I.V.) at 1 hr before the enrollment of transport under same experimental condition with Control group. The blood specimens were collected at 1 hr before transport, 2.3 hrs (135 km) and 5 hrs (274 km) after the enrollment of transport, and 1, 6 and 18 hrs after fulfillment of transport. The collected blood specimens were analyzed for cortisol and epinephrine. Core temperature and heart rate were measured with active biotelemetry in every 30 minutes from 0.5 hr before the start of transport to 18 hrs after the end of transport. In results, the level of cortisol considerably increased to the peak either in Control group ($5.3{\pm}1.3{\mu}g/d{\ell}$) and in Treatment group ($4.0{\pm}2.6{\mu}g/d{\ell}$) at 2.3 hrs in transport. The concentration of epinephrine of Treatment group had been higher than that of Control group from the start of transport to 18 hrs after the fulfillment of transport. Particularly there was the biggest gap between Control and Treatment groups, $424.0{\pm}194.1pg/m{\ell}$ and $209.1{\pm}65.1pg/m{\ell}$ respectively, at 6 hrs after the end of transport. The heart rates were considerably increased either in Control group ($81.5{\pm}18.5$ to $126.3{\pm}7.8beats/min$) and in Treatment group ($114.3{\pm}14.4$ to $140.8{\pm}22.4beats/min$) with the enrollment of transport. These results indicate that the concentration of cortisol and the heart rate were pertinent to cognitive parameters to evaluate physiological responses against stress such as transport. In addition, the intravenous administration of electrolyte-mineral solution could be suggested as the method to decrease the adverse effects from a transport stress.

  • PDF

Effects of Relative Humidity and Temperature on the Transport of Chloride in the Concrete

  • Nam Jin-Gak;Hartt William H.;Kim Ki-Joon
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.5 s.89
    • /
    • pp.821-828
    • /
    • 2005
  • To investigate the role of RH and temperature on the transport of chloride in the concrete, two groups of specimens were configured. For both groups, mix design was based on w/c=0.45, $400kg/m^3$ cement, $794kg/m^3$ fine aggregate and $858kg/m^3$ coarse aggregate. After specimen fabrication these were exposed to four different RH (35, 55, 75 and $95\%$ RH) and temperature (0, 20, 30 and $40^{\circ}C$) conditions. After 3 and 6 months $15\%$ NaCl exposure 5mm cores were taken. These cores were sliced and individual cores were ground to powder. In addition, to evaluate the effect of temperature on the chloride binding some powder samples were leached in the each of four temperature chambers. Chloride titration fur these was performed using FDOT acid titration method. Based upon the resultant data conclusions were reached regarding that 1) effective diffusion coefficient, $D_e$, increased with increasing exposure RH, suggesting that the size and number of water paths increased with elevated moisture content in the specimens, 2) $D_e$ increased with increasing temperature in the range of 0 to $40^{\circ}C$ possibly by elevated thermal activation of chloride ions and reduced chloride binding at higher temperature, 3) water soluble chloride concentration, $[Cl^-]_s$, increased with increasing temperature, and 4) chloride concentration profile for initially dry concrete specimens was higher than for the initially wet ones indicating pronounced capillary suction (sorption) occurred for the dry concrete specimens.

Theoretical Analysis of Heat Transport Limitation in a Screen Mesh Wick Heat Pipe

  • Lee, Ki-Woo;Park, Ki-Ho;Lee, Wook-Hyun;Rhi, Seok-Ho
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.12 no.1
    • /
    • pp.1-9
    • /
    • 2004
  • The purpose of the present study is to examine the heat transport limitations in a screen mesh heat pipe for electronic cooling by theoretical analysis. Diameter of pipe was 6mm, and mesh numbers were 50, 100, 150, 200 and 250, and water was investigated as working fluid. According to the change of mesh number, wick layer, inclination and saturation temperature, the maximum heat transport limitations by capillary, entraintment, sonic and boiling were analyzed by a theoretical design method of heat pipe, including capillary pressure, pumping pressure, liquid friction coefficient in wick, vapor friction coefficient, etc. Based on the results, the capillary limitation in a small diameter of heat pipe is largely affected by mesh number and wick layer. Mesh number of 250 is desirable not to be used in pipe diameter of 6 mm, because capillary heat transport limitation decreases by the abrupt increase of liquid friction pressure due to the small liquid flow area. For the heat transport of 15 watt in 6mm diameter pipe, mesh number of 100 and one layer is an optimum wick condition, which thermal resistance is the smallest.

Experimental Study of Thermal Performance of Heat Pipe with Axial Trapezoidal Grooves (축방향 사다리꼴 그루브 히트파이프의 열성능에 대한 실험적 연구)

  • Suh, Jeong-Se;Lee, Woon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.4
    • /
    • pp.407-414
    • /
    • 2003
  • Analysis and experiment are performed to investigate the thermal performance of a heat pipe with axial grooves. The heat pipe was designed in a 6.5 mm I.D., 17 axial trapezoidal grooves. 1000 mm long tube of aluminium, and ammonia as working fluid. A mathematical equations fur heat pipe with axial grooves is formulated to obtain the capillary limitation on heat transport rate in a steady state. As a result, heat transport factor of heat pipe has the maximum at the operating temperature of 293K in 0m elevation. As the elevation of heat pipe increases. the heat transport factor of the heat pipe is reduced markedly, comparing with that of horizontal elevation of the heat pipe. It may be considered that such behavior of heat pipe is caused by the working fluid swarmed back to the condenser port due to gravity force and supercooled by a coolant of heat exchanger. Analytical results of heat transport factor are in a good agreement with those of experiment.

The Impact of Southern Ocean Thermohaline Circulation on the Antarctic Circumpolar Current Transport

  • Kim, Seong-Joong;Lee, Bang-Yong
    • Journal of the Korean Geophysical Society
    • /
    • v.9 no.4
    • /
    • pp.291-299
    • /
    • 2006
  • The observed ocean barotropic circulation is not completely explained by the classical wind-driven circulation theory. Although it is believed that the thermohaline forcing plays a role in the ocean barotropic circulation to some degree, how much the thermohaline forcing contributes to the barotropic circulation is not well known. The role of thermohaline circulation driven by changes in temperature and salinity in the Southern Ocean (SO) water masses on the Antarctic Circumpolar Current (ACC) transport is investigated using a coupled ocean - atmosphere - sea ice - land surface climate system model in a Last Glacial Maximum (LGM) context. Withthe implementation of glacial boundary conditions in a coupled model, a substantial increase in the ACC transport by about 75% in 80 years of integration and 25% in the near LGM equilibrium is obtained despite of the decreases in the magnitude of wind stresses over the SO by 33% in the transient time and 20% in the near-equilibrium. This result suggests that the increase in the barotropic ACC transport is due to factors other than the wind forcing. The change in ocean thermohaline circulation in the SO seems to play a significant role in enhancing the ACC transport in association with the change in the bottom pressure torque.

  • PDF

Numerical Analysis of Transport Current Losses in Stacked HTS Conductors (적층 형태의 고온 초전도선재에서의 통전손실 수치 해석)

  • 최세용;나완수;김정호;주진호;류경우
    • Progress in Superconductivity
    • /
    • v.5 no.2
    • /
    • pp.89-93
    • /
    • 2004
  • We have studied alternating transport current losses in the vertically stacked high temperature superconducting tapes(HTS) using numerical techniques. In the case of stacked conductors, HTS tapes are exposed to self-field generated by transport current itself and also experienced external magnetic field around adjacent tapes. It is well known that magnetic interactions between neighbored tapes have significant effect on their properties of superconducting tapes such as current distribution, AC loss, and critical current. In this paper, we investigated the transport current losses in stacked conductors consisting of a few of the HTS tapes using numerical analysis. Current distributions are calculated in HTS tape cross-section taking account of magnetic field dependencies, which are represented superconducting nonlinear properties. Dissipated losses in tape and stacked conductors were integrated with current distribution and electric field intensity in the whole conductor region. Finally estimated results were discussed and verified through the analytical theory.

  • PDF

Cause of Corrosion and Evaluation of Material Corrosion Resistance on Underground Heat Transport Facilities Connected to Manhole (맨홀과 연결된 지하 열수송설비의 부식 원인 및 재질 내식성 평가)

  • Song, M.J.;Choi, G.;Kim, W.C.;Lee, S.Y.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.35 no.4
    • /
    • pp.193-202
    • /
    • 2022
  • Manholes and underground spaces are installed to manage the buried heat transport pipes of the district heating system, and the corrosion damage of the equipment placed in this space often occurs. The purpose of this work is to identify locations with a high risk of corrosion damage in the air vent and to establish preventive measures based on precise analysis via sampling of heat transport pipes and air vents that have been used for about 30 years. The residual thickness of the air vent decreased significantly by reaching ~1.1 mm in thickness, and locations of 60~70 mm away from a transport pipe were the most vulnerable to corrosion. The energy dispersive X-ray spectroscopy (EDS) analysis was performed in the corroded oxides, and it was found that chloride ion was contained in the corrosion products. Anodic polarization tests were carried out on the air vent materials (SPPS250, SS304) with varying the amounts of chloride ions at two different temperatures (RT, 80℃). The higher concentration of chloride ions and temperature are, the lower corrosion resistances of both alloys are.