• Title/Summary/Keyword: Transparent solar module

Search Result 32, Processing Time 0.016 seconds

Changes in Optical Properties of Crystalline-Si PV Modules after Natural Light Exposure (자연광 노출 후 결정질 실리콘 PV모듈의 광학적 특성 변화)

  • Kong, Ji-Hyun;Ji, Yang-Guen;Kang, Gi-Hwan;Yu, Gwon-Jong;Ahn, Hyung-Keun;Han, Deuk-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.64-64
    • /
    • 2010
  • This paper presents the results of changes of optical properties of front materials in crystalline PV modules. If PV modules on the outdoor, transmittance of front materials is reduced by solar light. That is UV, IR included Solar spectrum will have change the properties of glass. Therefore decrease in transmittance leads to loss of the PV modules output. All the PV modules showed the loss in Isc by 1~5% within few hors. To investigate the changes we are analyzed using spectrophotometer from raw glass to laminated glass.

  • PDF

A Study on Analysis for Energy Demand of the Heating, Cooling and Lighting in Office Building with Transparent Thin-film a-Si BIPV Window (투광형 박막 BIPV 창호 적용에 따른 냉난방 및 조명 부하 저감에 관한 연구)

  • Yoon, Jong-Ho;An, Young-Sub;Park, Jang-Woo;Kim, Bit-Na
    • KIEAE Journal
    • /
    • v.13 no.3
    • /
    • pp.91-96
    • /
    • 2013
  • The purpose of this study was to analyze the annual energy demand including heating, cooling and lighting according to kind of windows with transparent thin-film a-Si Building Integrated Photovoltaic(a-Si BIPV) for office building. The analysis results of the annual energy demand indicated that the a-si BIPV window was reduced by 8.4% than the clear gazing window. The base model A was combinate with a-Si BIPV window area of 67% and clear window area of 33% among the total exterior area. The model B is to be applied with low-e clear glass instead of clear glass of the base model A. The model B was reduced to annual energy demand of 1% more than the model A. Therefore, By using a-si BIPV solar module, the cooling energy demand can be reduced by 53%(3.4MWh) and the heating energy demand can be increase by 58%(2.4MWh) than clear glazing window in office building. Also, Model C applied to the high efficient lighting device to the model B was reduced to annual energy demand of 14.4% more than the Model D applied to the high efficient lighting device to the model A. The Model E applied with daylight dimming control system to the Model C was reduced to annual energy demand of 5.9% more than Model C.