• Title/Summary/Keyword: Transosseous fixation

Search Result 8, Processing Time 0.034 seconds

Transosseous Tie Fixation Using Krackow Sutures and Bone Tunnels in a Comminuted Fracture of the Upper Pole of the Patella: A Case Report

  • Baik, Jong Seok
    • Journal of Trauma and Injury
    • /
    • v.34 no.4
    • /
    • pp.305-308
    • /
    • 2021
  • Comminuted fractures of the patella mostly occur at the inferior pole and require appropriate reduction and fixation to restore the extensor mechanism. Conventional methods such as tension-band wiring are not enough to gain proper fixation strength. Numerous methods have been reported, including circumferential cerclage wiring, osteosynthesis, and suture anchors depending on the fracture pattern. Herein, the author reports a relatively rare case of a comminuted fracture of the upper pole of the patella, for which we used augmented Krackow sutures in the quadriceps and fixation with tying of the suture limbs through patellar bone tunnels. Satisfactory results were obtained in terms of reduction and extensor mechanism recovery.

The suture bridge transosseous equivalent technique for Bony Bankart lesion

  • Choe, Chang-Hyeok;Kim, Sin-Geun;Baek, Seung-Hun;Sin, Dong-Yeong
    • The Academic Congress of Korean Shoulder and Elbow Society
    • /
    • 2008.03a
    • /
    • pp.178-178
    • /
    • 2008
  • In order to improve static stability and healing of reattached labrum, we combined the advantages of suture bridge and transosseous technique. Using the conventional 3 portal for anterior instability, check stability of bony Bankart and preparation of glenoid bed in 3 way including removal, reshaping or mobilization of bony fragment. Two anchors were inserted to the superior and inferior portion and medial edge of bony Bankart lesion. It usually corresponded to the area of IGHL. Medial mattress sutures were applied around IGHL complex to get enough depth of glenoid coverage using suture hook. Make 3.5mm pushlock anchor hole to the articular edge of glenoid cartilage. Proximal suture bridge was applied at first and then distal suture bridge was inserted to mobilize the labrum in proximal direction. These construction can provide more stable labral repair with wide contact and compression in case of deficient bony stability. It not only avoids technical disadvantage of point contact with anchor fixation, but also decreasing gap formation through cross compression of labrum that couldn't gain even with the transosseous fixation which affords linear compression effect. Additional bony stability could be gained if the the bony fragment was mobilized to the glenoid margin with potential healing bed or reshaped for the good contact with reattached labrum.

  • PDF

Biomechanical Test for Repair Technique of Full-thickness Rotator Cuff Tear

  • Lim, Chae-Ouk;Park, Kyoung-Jin
    • Clinics in Shoulder and Elbow
    • /
    • v.19 no.1
    • /
    • pp.51-58
    • /
    • 2016
  • The arthroscopic rotator cuff repair is now considered a mainstream technique with highly satisfactory clinical results. However, concerns remain regarding healing failures for large and massive tears and high revision rate. In recent decades, various repair strategies and construct configurations have been developed for rotator cuff repair with the understanding that many factors contribute to the structural integrity of the repaired construct. The focus of biomechanical test in arthroscopic repair has been on increasing fixation strength and restoration of the footprint contact characteristics to provide early rehabilitation and improve healing. These include repaired rotator cuff tendon-footprint motion, increased tendon-footprint contact area and pressure, and tissue quality of tendon and bone. Recent studies have shown that a transosseous tunnel technique provides improved contact area and pressure between rotator cuff tendon and insertion footprint, and the technique of using double rows of suture anchors to recreate the native footprint attachment has been recently described. The transosseous equivalent suture bridge technique has the highest contact pressure and fixation force. In this review, the biomechanical tests about repair techniques of rotator cuff tear will be reviewed and discussed.

A Suture Bridge Transosseous-Equivalent Technique for Bankart Lesions with Deficient Bony Stability - Technical Note - (골안정성 결손을 가진 Bankart 병변에 대한 경 골-유사 교량형 봉합술식 - 술기 보고 -)

  • Choi, Chang-Hyuk;Kim, Shin-Kun;Chang, Il-Woong;Chae, Sung-Bum
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.2
    • /
    • pp.179-182
    • /
    • 2009
  • Purpose: Point fixation at the margin of the glenoid is a limitation of conventional arthroscopic stabilization using suture anchors, and does not afford sufficient footprint healing, especially in glenoid bone deficiency. So, we introduce an arthroscopic suture bridge transosseous-equivalent technique for bony Bankart lesions to avoid the technical disadvantage of point contact with anchor fixation and to improve mechanical stability through cross compression of the labrum. Surgical approach: The technique was adapted from the transosseous-equivalent rotator cuff repair technique using suture bridges, which improved the pressurized contact area and mean pressure between the tendon and footprint. After preparation of the glenoid bed by removal, reshaping, or mobilization of the bony lesion, two anchors (3.0 mm Biofastak, $Arthrex^{(R)}$, Naples, FL) were inserted into the superior and inferior portion of the bony Bankart lesion. Using a suture hook, medial mattress sutures were applied around the capsulolabral portion of the IGHL complex to obtain sufficient depth of glenoid coverage. A 3.5 mm pushloc anchor ($Arthrex^{(R)}$, Naples, FL) hole was made in the articular edge of the anterior glenoid rim. distal, suture bridge was applied, and proximal was inserted to mobilize the labrum in the proximal direction. This avoided the technical disadvantage of point contact with anchor fixation and decreased the level of gap formation through cross-compression of the labrum.

  • PDF

Cement Augmentation for Lateral Row Fixation in Rotator Cuff Repair: A Case Report

  • Kim, Jin Hwan;Koh, Kyoung-Hwan
    • Clinics in Shoulder and Elbow
    • /
    • v.20 no.1
    • /
    • pp.42-45
    • /
    • 2017
  • One of the most important factors leading to a successful healing of rotator cuff tear is good bone quality to secure the suture anchor in the bone for a stable fixation. However, rotator cuff tear are commonly found in elderly patients, and their proximal humerus often shows osteoporosis or cystic lesions. Especially when the transosseous repair prevails for a torn rotator cuff, a weak metaphyseal cancellous bone is often the case, which associated with difficulty in stable fixation of the lateral row suture anchor. In this situation, we were able to augment the lateral row fixation with polymethylmethacrylate bone cement. Although there is a concern of disturbance in the blood flow and healing potential, our case showed good clinical results with respect to healing. If we suspect a weak fixation of the lateral row suture anchor, bone cement seems to be a good option for augmentation.

Arthroscopic Rotator Cuff Repair by Single Row Technique (회전근 개 파열에 대한 관절경적 봉합술 중 일열 봉합술의 유용성)

  • Yum, Jae-Kwang
    • Clinics in Shoulder and Elbow
    • /
    • v.11 no.2
    • /
    • pp.77-81
    • /
    • 2008
  • The goal of rotator cuff repairs is to achieve high initial fixation strength, minimize gap formation, maintain mechanical stability under cyclic loading and optimize the biology of the tendon-bone interface until the cuff heals biologically to the bone. Single row repairs are least successful in restoring the footprint of the rotator cuff and are most susceptible to gap formation. Double row repairs have an improved load to failure and minimal gap formation. Transosseous equivalent repairs (suture bridge technique) have the highest ultimate load and resistance to shear and rotational forces and the lowest gap formation. Even though the superior advantages of double row and transosseous equivalent repairs, those techniques take longer surgical time and are more expensive than single row repairs. Therefore single row repairs can be useful in bursal side partial thickness or small size full thickess rotator cuff tear.

THE LONG-TERM CONSERVATIVE DRAINAGE CARE OF EXTENSIVE OSTEOMYELITIS ASSOCIATED WITH MANDIBULAR COMPOUND FRACTURE : REPORT OF A CASE (장기간의 보존적 배농술로 치료된 하악 복합골절 관련 광범위 골수염 치험 : 증례보고)

  • Kim, Ha-Rang;Yoo, Jae-Ha;Choi, Byung-Ho;Sul, Sung-Han;Mo, Dong-Yub;Lee, Chun-Ui
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.31 no.6
    • /
    • pp.544-549
    • /
    • 2009
  • Failure to use effective methods of reduction, fixation and immobilization may lead to osteomyelitis with the exposed necrotic bone, as the overzealous use of transosseous wires & plates that devascularizes bone segments in the compound comminuted fractures of mandible. Once osteomyelitis secondary to fractures has become established, intermaxillary fixation should be instituted as early as possible. Fixation enhances patient comfort and hinders ingress of microorganisms and debris by movement of bone fragments. Teeth and foreign materials that are in the line of fracture should be removed and initial debridement performed at the earliest possible time. Grossly necrotic bone should be excised as early as possible ; no attempt should be made to create soft tissue flaps to achieve closure over exposed bone. The key to treatment of chronic osteomyelitis of the mandible is adequate and prolonged soft tissue drainage. If good soft tissue drainage is provided over a long period, sequestration of infected bone followed by regeneration or fibrous tissue replacement will occur so that appearance and function are not seriously altered. Localization and sequestration of infected mandible are far better performed by natural mechanism of homeostasis than by cutting across involved bone with a cosmetic or functional defect. As natural host defenses and conservative therapy begin to be effective, the process may become chronic, inflammation regresses, granulation tissue is formed, and new blood vessels cause lysis of bone, thus separating fragments of necrotic bone(sequestra) from viable bone. The sequestra may be isolated by a bed of granulation tissue, encased in a sheath of new bone(involucrum), and removed easily with pincettes. This is a case report of the long-term conservative drainage care in osteomyelitis associated with mandibular fractures.