• 제목/요약/키워드: Transmission scan

검색결과 97건 처리시간 0.023초

QUALITY EVALUATION OF TECHNOLOGY OF AGRICULTURAL PRODUCTS

  • Chen, Pictiaw
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1996년도 International Conference on Agricultural Machinery Engineering Proceedings
    • /
    • pp.171-190
    • /
    • 1996
  • Quality evaluation of agricultural products has been a subject of interest to many researches for many years. As a results, several nondestructive techniques for quality evaluation of agricultural products have been developed. These methods are based on the detection of various physical properties that correlate well with certain quality factors of the products. This paper presents an overview of various quality evaluation techniques that are based on one of the following properties : density, firmness , vibration characteristic , X-ray and gamma ray transmission, optical reflectance and transmission , electrical properties, aromatic volatile emission, and nuclear magnetic resonance (NMR). The sophistication of nondestructive methods has evolved rapidly with modern technologies. The use of various modern image acquisition techniques, such as solid state TV camera, line-scan camera, X-ray scanning , ultrasonic scanning and NMR imaging, in conjunction with image-processing te hniques has provided new opportunities for researchers to develop many new and improved techniques for nondestructive quality evaluation of agricultural products.

  • PDF

고정된 프레임 크기를 갖는 PS 알고리즘의 성능 분석 (Performance Analysis of PS Algorithm with FIxed Frame Length)

  • 임인택
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2014년도 춘계학술대회
    • /
    • pp.547-549
    • /
    • 2014
  • RFID 시스템의 태그 식별 성능은 동시에 응답하는 태그들로 인한 태그 충돌 확률과 밀접한 관계가 있다. PS 알고리즘은 리더의 송신 전력을 점진적으로 증가시키면서 리더의 식별 영역 내에 있는 태그들을 그룹화하여 식별하는 기법이다. 이 기법에서는 매 스캔 과정을 수행할 때마다 고정된 크기의 프레임을 사용한다. 이로 인하여 PS 알고리즘의 성능은 태그의 수, 프레임 크기, 및 전력 증가 값에 따라 다양하게 나타나는 문제점이 있을 것으로 예상된다. 따라서 본 논문에서는 프레임 크기와 전력 증가 값에 따른 PS 알고리즘의 성능을 분석한다.

  • PDF

DCT 부호화 영상의 최적 비트 정렬에 의한 점진적 전송 (Progressive transmission using optimum bit-ordering of DCT coded image)

  • 채종길
    • 한국통신학회논문지
    • /
    • 제19권4호
    • /
    • pp.679-684
    • /
    • 1994
  • 전체 부호화 비트중 일부 비트이 수신만으로도 나은 양호한 영상을 재생할 수 있는 DCT 부화화 영상의 최적 비트 정열에 의한 점진적 전송을 제안하였다. 이는 한 비크 더 전송함으로서 재생 영상의 왜곡을 가장 많이 줄이는 비트부터 단계적으로 전송하는 것이다. 이를 위해서 Embedded 양자화기의 재생 레벨과 한비트 더 전송함으로서 얻어지는 새로운 재생 레벨과 차의 제곱을 의미하는 PTF를 정의하였으며 부호화 비트에대한 PTF를 순차 정렬함으로서 비트 전송 순서를 얻었다. 결과로 제안한 방법은 기존의 zig-zag주사에 의한 전송보다 동일 비트율에서 작은 왜곡과 보다 나은 화질을 갖는 영상을 재생할 수 있었다.

  • PDF

하이드로겔 렌즈와 실리콘-하이드로겔 렌즈가 각막 두께에 미치는 영향 (Effect of Hydrogel lens and Silicone-Hydrogel lens on Corneal thickness)

  • 서정익
    • 한국임상보건과학회지
    • /
    • 제5권4호
    • /
    • pp.1021-1025
    • /
    • 2017
  • Purpose: Changes in corneal thickness after wearing hydrogel lens and silicone-hydrogel lens with different oxygen transmission rates wew syudied. Methods: Experiments were performed on 11 subjects(22 eyes). corneal thickness was measured after wearing contact lenses for 8 hours. Corneal thickness was measured using ORB Scan II(ver. 3.14) Results: In the results of the corneal thickness measurement by direction, in the case of the hydrogel-tor lens, the center thickness was $33.63{\mu}m$, the nasal was $34.29{\mu}m$, the temporal was $27.17{\mu}m$, the inferior was $27.17{\mu}m$, the superior was $18.90{\mu}m$, and change rates were 6.28%, 5.71%, 5.40%, 4.75% and 3.09%, respectively. In the results of the corneal thickness measurement by diameter, in the case of the hydrogel-tor lens, the center was $33.63{\mu}m$, the mid-peripheral was $28.19{\mu}m$, the peripheral was $24.18{\mu}m$, and change rates were 6.28%, 4.76%, and 3.79%, respectively. Conclusions: The hydrogel lenses with relatively low oxygen transmission rates resulted in a significant increase in thickness over the entire cornea compared to silicon-hydrogel lenses with high oxygen transmission rates.

Precipitation of Eu3+ - Yb3+ Codoped ZnAl2O4 Nanocrystals on Glass Surface by CO2 Laser Irradiation

  • Bae, Chang-hyuck;Lim, Ki-Soo;Babu, P.
    • Current Optics and Photonics
    • /
    • 제2권1호
    • /
    • pp.79-84
    • /
    • 2018
  • We present a novel and simple method to enable spatially selective $ZnAl_2O_4$ nanocrystal formation on the surface of $B_2O_3$-$Al_2O_3$-ZnO-CaO-$K_2O$ glass by employing localized laser heating. Optimized precipitation of glass-ceramics containing nanocrystals doped with $Eu^{3+}$ and $Yb^{3+}$ ions was performed by controlling $CO_2$ laser power and scan speed. Micro-x-ray diffraction and transmission electron microscopy revealed the mean size and morphology of nanocrystals, and energy dispersive x-ray spectroscopy showed the lateral distribution of elements in the imaged area. Laser power and scan speed controled annealing temperature for crystalization in the range of 1.4-1.8 W and 0.01-0.3 mm/s, and changed the size of nanocrystals and distribution of dopant ions. We also report more than 20 times enhanced downshift visible emission under ultraviolet excitation, and 3 times increased upconversion emission from $Eu^{3+}$ ions assisted by efficient sensitizer $Yb^{3+}$ ions in nanocrystals under 980 nm excitation. The confocal microscope revealed the depth profile of $Eu^{3+}$ ions by showing their emission intensity variation.

Influence of Resin-Infiltrated Time on Wood Natural Materials Using Conventional/Air-Coupled Ultrasound Waves

  • Park, Je-Woong;Kim, Do-Jung;Kweon, Young-Sub;Im, Kwang-Hee;Hsu, David K.;Kim, Sun-Kyu;Yang, In-Young
    • 비파괴검사학회지
    • /
    • 제29권3호
    • /
    • pp.235-241
    • /
    • 2009
  • Composite wood materials are very sensitive to water and inspection without any coupling medium of a liquid is really needed to wood materials due to the permeation of coupling medium such as water. However, air-coupled ultrasound has obvious advantages over water-coupled experimentation compared with conventional C-scanner. In this work, it is desirable to perform contact-less nondestructive evaluation to assess wood material homogeneity. A wood material was nondestructively characterized with non-contact and contact modes to measure ultrasonic velocity using automated data acquisition software. We have utilized a proposed peak-delay measurement method. Also through transmission mode was performed because of the main limitation for air-coupled transducers, which is the acoustic impedance mismatch between most materials and air. The variation of ultrasonic velocity was found to be somewhat difference due to air-coupled limitations over conventional scan images. However, conventional C-scan images are well agreed with increasing the resin-infiltrated time as expected. Finally, we have developed a measurement system of an ultrasonic velocity based on data acquisition software for obtaining ultrasonic quantitative data for correlation with C-scan images.

구조적 희소성 기반 압축 센싱 알고리즘을 통한 측면주사소나 영상의 비균일 잡음 제거 (Non-homogeneous noise removal for side scan sonar images using a structural sparsity based compressive sensing algorithm)

  • 진영생;구본화;이승호;김성일;고한석
    • 한국음향학회지
    • /
    • 제37권1호
    • /
    • pp.73-81
    • /
    • 2018
  • 측면주사소나 영상의 화질은 소나 운용 주파수의 영향을 받는다. 저주파 측면주사소나 장비로 얻는 영상은 저화질 영상이며, 잡음이 화질 저하의 요소 중 하나가 된다. 균일한 잡음을 가정하는 광학 영상과는 달리. 측면주사소나 데이터의 잡음은 해양 환경(장비 소음, 신호 간섭 등)에 의해 발생한다. 또한 소나 신호의 전달 손실을 보상하고자 시간변환이득(Time-Varied Gain, TVG)을 수행하며, 이로 인해 측면주사소나 영상에 비균일 잡음이 생성된다. 본 논문에서는 측면주사소나 영상에 포함된 비균일 잡음을 제거하는 구조적 희소성에 기반한 압축 센싱 알고리즘 (Structural Sparsity based Compressive Sensing, SSCS)을 제안한다. 영상의 구조적 특징 도메인에서 국부적 및 비국부적 모델링을 동시에 구현하여 계수의 희소성을 보장하면서 비국부적 자가 유사성을 강화한다. 그리고 잡음의 비균일성을 고려하여 비국부적 모델링을 보상한다. 다양한 모의 실험을 통해 제안한 알고리즘의 우수성을 입증한다.

PET/CT 시스템에서 CT 영상을 이용한 감쇠 보정 시 조영제가 PET 영상에 미치는 영향 (Impact of Contrast agent for Attenuation Correction Using CT Scan in PET/CT System)

  • 손혜경;;권윤영;봉정균;정해조;김희중
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2004년도 제29회 추계학술대회 발표논문집
    • /
    • pp.100-103
    • /
    • 2004
  • 본 연구에서는 PET/CT시스템에서 CT영상을 이용한 감쇠 보정 시 조영제가 PET영상에 미치는 영향을 관찰하기 위해 팬텀실험과 모의실험을 수행하였다. 다양한 농도로 희석한 조영제를 채운 플라스틱 병을 스티로폼을 이용하여 전신 팬텀 내에 고정시킨 후 투과 영상을 획득하였다. 모의실험을 위해 인체 기관 중 간을 가진 수학적 방출 스캔 맵과 투과 스캔 맵을 각각 만들었다. 간에서 조영제가 비 균일하게 증강된 투과 스캔 맵, 간에 조영제의 증강이 있는 투과스캔 맵과 없는 투과 스캔 맵, 간에 있는 종양에 조영제의 hypo-attenuating이 있는 투과 스캔 맵, 그리고 각각의 다른 조영제의 감쇠 정도를 가지는 간을 구현한 투과 스캔 맵을 각각 만들고 이를 이용하여 방출 영상을 감쇠 보정하였다. 팬텀실험을 통해 조영제의 농도에 따라 감쇠 정도가 달라짐을 확인하였다. 모의실험을 통해 감쇠 보정된 방출 영상이 조영제에 의해 영향을 받고, 또한 인공산물이 발생할 수 있음을 확인하였다. 따라서 조영제와 같은 물리적 인자가 감쇠 보정에 미치는 영향을 충분히 이해하고 정량적 분석 또는 진단 등에 고려하여야 할 것으로 생각한다.

  • PDF

F-18-FDG감쇠보정 전신 PET을 이용한 표준섭취계수 추정과 매개변수 영상의 구성 (Parametric Images of Standardized Uptake Values using P-18-FDG Attenuation Corrected Whole Body PET)

  • 김경민;곽철은;이동수;정재민;정준기;이명철;고창순;김영진
    • 대한핵의학회지
    • /
    • 제30권4호
    • /
    • pp.560-569
    • /
    • 1996
  • F-18-FDG 전신 PET을 촬영하여 분할/편평화 방법으로 감쇠보정한 전신 영상을 만들었으며 이어 SUV 매개변수 영상을 구성하여, 측정한 것을 그대로 사용한 방법과 분할/편평화 후에 감쇠보정하는 방법에 따라 SUV 추정 성능이 달라지는지 보았다. 모형실험의 결과 SUV 계산식이 적절함을 확인하였고 측정 감쇠보정 방법에 비해 분할/편평화 감쇠보정 방법을 이용하여 만든 영상이 화질이 우수하고, 구한 SUV 값은 국소스캔에 의한 SUV에 비해 측정 감쇠보정 방법은 SUV가 조금 높게, 분할/편평화 감쇠보정 방법은 조금 낮음을 알았다 환자를 대상으로 적용한 결과 분할/편평화 방법으로 감쇠보정한 전신 영상의 화질은 우수하여 판독에 적합하였다. 환자 국소 매개변수 영상과 전신 매개변수 영상에서 병소부위의 SUV는 감쇠방법에 따라 작은 차이가 있었다. 23명의 환자에서 전신 SUV는 분할/편평화 감쇠보정 방법을 사용한 경우 국소스캔에서 얻은 SUV보다 조금 낮았다. 전신SUV를 측정한 것을 그대로 사용하여 얻으면 국소스캔에서 얻은 SUV보다 조금 덜 낮았다. SUV를 측정할 때 개입하는 병변의 특성이 뚜렷한 차이를 보이는 것을 고려할 때 우리가 발견한 방법간 SUV값의 차이는 상대적으로 작아 분할/편평화 후 감쇠보정 방법을 이용한 전신 SUV 매개변수 영상에서 얻은 SUV를 국소스캔에서 측정한 SUV와 서로 바꾸어 사용하여도 좋다고 생각한다.

  • PDF

Effect of O2 Partial Pressure on AlOx Thin Films Prepared by Reactive Ion Beam Sputtering Deposition

  • Seong, Jin-Wook;Yoon, Ki-Hyun;Kim, Ki-Hwan;Beag, Young-Whoan;Koh, Seok-Keun
    • 한국세라믹학회지
    • /
    • 제41권5호
    • /
    • pp.364-369
    • /
    • 2004
  • The barrier and optical properties of AlO$_{x}$ thin films on polycarbonate deposited by Reactive Ion Beam Sputtering (RIBS) were investigated at different oxygen partial pressure. We measured the deposition rate of AlO$_{x}$ thin films. As the oxygen partial pres-sure increased, the deposition rate increased then decreased. The changes of deposition rate are associated with the properties of deposited films. The properties of deposited AlO$_{x}$ thin films were studied using X-ray Photoelectron Spectroscopy (XPS), Scan-ning Electron Microscopy (SEM), and Atomic Force Microscopy (AFM). Optimum deposition parameters were found for fabricat-ing aluminum oxide thin films with high optical transparency for visible light and low Oxygen Transmission Rate (OTR). The optical transmittance of AlO$_{x}$ thin film deposited on polycarbonate (PC) showed the same value of bare PC.bare PC.