• Title/Summary/Keyword: Transmission coefficients

Search Result 394, Processing Time 0.027 seconds

Quality characteristics of soybean sprouts packaged with different packaging materials during their storage (포장 필름의 종류에 따른 저장 중 콩나물의 품질특성)

  • Hwang, Tae-Young
    • Food Science and Preservation
    • /
    • v.20 no.5
    • /
    • pp.602-607
    • /
    • 2013
  • Correct packaging enables processors to pack fresh produce and extend its shelf life. This study was carried out to investigate the effect of different packaging materials on the weight loss, pH, $O_2$, $CO_2$ and sensory characteristics of soybean sprouts during their storage at $5^{\circ}C$ for seven days. Soybean sprouts ($320{\pm}20g$) were packaged with oriented polypropylene (OPP) and cast polypropylene (CPP) films, respectively. The $O_2$ transmission rate of the packaging materials was set to have a control of $10,000cc/m^2$.day.atm, and an OP15 and CP15 with $15,000cc/m^2$.day.atm through a pre-screening test. The average weight loss of the soybean sprouts during their storage was less than 10%, and that of the soybean sprouts with a CPP film was higher than that of the OPP film. The pH of the soybean sprouts increased during their storage regardless of their packaging materials; but compared to the pH of the soybean sprouts packaged with OPP, those packaged with CPP were higher. The $CO_2$ content of the packaging increased with a decrease in the $O_2$ content. The ratio of $CO_2$ to $O_2$ in the soybean sprouts with the OPP film was 3.5 times higher than in the soybean sprouts with the CPP film. The results of the overall sensory test showed that the marketability of the soybean sprouts packaged with OPP film and stored at $5^{\circ}C$ seemed to have been maintained effectively for six days (at a $15,000cc/m^2$.day.atm $O_2$ transmission rate). When the correlation coefficients of the control, OP15 and CP15 were analyzed, the highest correlation was shown between a control and OP15 (0.986; p<0.01).

A Comparative Evaluation on the Thermal Insulation Performance of Windows according to the Temporary Improvement Method (창호의 단열성능 간이 개선방법의 비교 분석)

  • Lee, Sung-Jin;Kim, Jeong-Gook;Kim, Jonghun;Jeong, Hakgeun;Lee, Jin-Sook;Jang, Cheol-Yong
    • KIEAE Journal
    • /
    • v.15 no.1
    • /
    • pp.77-82
    • /
    • 2015
  • The purpose of this study is to compare the thermal insulation performance of windows according to the formation of air layer and to evaluate its energy efficiency on a selected standard house. A thermal insulation test, KS F 2278 was used to measure U-values (Heat transmission coefficients) for the following three cases: the first case (Case 1) is a Low-E pair glass (Argon injected), the second case (Case 2) is a Low-E pair glass with the air cap attached on the glass surface, and the third case (Case 3) is a Low-E pair glass, on the frame of which the air cap is attached. The evaluation of the energy efficiency was conducted according to a building energy calculation method from ISO 13790, calculation of energy use for space heating and cooling, using the U-values obtained from the thermal insulation tests. As results of the tests, the U-values of Case 1, Case 2, and Case 3 were $1.668W/m^2{\cdot}K$, $1.568W/m^2{\cdot}K$, and $1.319W/m^2{\cdot}K$ respectively. The Case 2 had about 5.9% lower value than the Case 1, and the Case 3 had about 20.9% lower value than the Case 1. It seems that the thermal performance of the windows is attributed to an increase of the heat resistance and the thickness of air layer. An evaluation of the energy efficiency of the three cases on the selected standard house showed that the amount of heating energy demand per unit area was $7.776kWh/m^2{\cdot}yr$ for the Case $1,6.856kWh/m^2{\cdot}yr$ for the Case 2, and $4.856kWh/m^2{\cdot}yr$ for the Case 3. This study suggests that the formation of air layer (by using air cap) and its thickness should reduce the heat energy demand and thus improve the energy saving efficiency

New Design Method of Wireless Power Transfer System Using Loop Antennas (루프 안테나를 이용한 무선 전력 전송 시스템의 새로운 설계법)

  • Kim, Hee-Seung;Won, Do-Hyun;Lim, Jae-Bong;Jang, Byung-Jun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.1
    • /
    • pp.36-45
    • /
    • 2010
  • In this paper, we propose a new design method to design a wireless power transfer system using loop antennas for consumer electronics. This method can simply design a wireless power transfer system only using measurements of coupling coefficients and simple equations of equivalent circuit model about loop antennas without complicated electromagnetic analysis. Using the proposed design method, a wireless power transfer system with a pair of loop antennas operating at the frequency of 13.56 MHz, which have a dimension of $50{\times}50\;cm^2$, is designed and implemented. The input return loss, coupling coefficient, efficiency, and input impedance variation with respect to a distance between loop antennas were measured. The proposed design method provides good agreements between measured and predicted results. Also, the wireless power transfer system with impedance matching circuits designed by the proposed design method shows two times higher efficiency characteristics than the case with the general $50\;{\Omega}$ impedance matching circuits. Therefore, we verified that our design method could be an effective tool to design a wireless power transfer system.

Estimation of Heat Insulation and Light Transmission Performance According to Covering Methods of Plastic Greenhouses (플라스틱온실의 피복방식에 따른 보온 및 광투과 성능 평가)

  • Lee, Hyun-Woo;Kim, Young-Shik;Sim, Sang-Youn;Lee, Jong-Won;Diop, Souleymane
    • Journal of Bio-Environment Control
    • /
    • v.22 no.3
    • /
    • pp.270-278
    • /
    • 2013
  • The objective of the present study is to provide data needed to decide covering method to be able to increase the thermal insulation and light transmittance efficiency of commercial greenhouse. The thermal insulation effect, PPF transmittance and quantity of condensation water were estimated in experimental tomato greenhouses covered with three types of coverings of single layer, air inflated and conventional double layers covering. The overall heat flow of air inflated double layers greenhouse was similar to that of conventional double layers greenhouse, but the temperature between covering material and thermal screen in air inflated double layers greenhouse was lower than that in conventional double layers greenhouse at the same outside temperature condition due to air leakage through the gap of roof vent. The overall heat transfer coefficients acquired by experiment that was performed in single layer and conventional double layers greenhouses were close to those obtained from model experiment. Even though the PPF transmittance of air inflated double layers greenhouse was lower than that of single layer greenhouse, which was greater than that of conventional double layers greenhouse. The quantity of condensation water on covering surface of single layer greenhouse was greater than that of air inflated double layers greenhouse due to lower covering surface temperature.

Digital Video Watermarking Based on SPIHT Coding Using Motion Vector Analysis (움직임 벡터 정보를 이용한 SPIHT 부호화 기반의 디지털 비디오 워터마킹)

  • Kwon, Seong-Geun;Hwang, Eui-Chang;Lee, Mi-Hee;Jeong, Tai-Il;Kwon, Ki-Ryong
    • Journal of Korea Multimedia Society
    • /
    • v.10 no.11
    • /
    • pp.1427-1438
    • /
    • 2007
  • Video watermarking technologies are classified into types of four kinds. The first type is to embed the watermark into a raw video signal and to code the watermarked video signal. Most of video watermarking technologies fall into the category of this type. The second type is to apply watermarking to the coding process, such as block DCT and quantization. The third is to directly embed the watermark into the compressed bitstream itself. Generally, it is referred as labelling rather than watermarking. Finally, the fourth is to embed the water mark into MPEG motion vector. This type has the difficulty in real-time process because of the high complexity and has the blocking effects because of DCT-based on coder. In this paper, we proposed the digital video watermarking that embed the watermark in SPIHT video code for I-frame using motion vector analysis. This method can remove the blocking effect occurred at the DCT-based on coder and obtain video data that has progressive transmission property. The proposed method is to select the region for the watermark embedding in I frame using motion vector estimated from the previous P or B frame. And then, it is to perform DWT and embed the watermark based on HVS into the wavelet coefficients in the same subband of DWT as the motion vector direction. Finally, the watermarked video bitstream is obtained by the SPIHT coder. The experimental results verified that the proposed method has the invisibility from the objective and subjective image quality and the robustness against the various SPIHT compression and MPEG re-code.

  • PDF

X-Band 6-Way Waveguide Power Divider Using Inductive Post (유도성 포스트를 활용한 X-Band 6-Way 도파관 전력 분배기)

  • Kim, Dong-Hyun;Oh, Soon-Soo;Min, Kyeong-Sik;Kang, Suk-Youb
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.4
    • /
    • pp.417-426
    • /
    • 2010
  • This paper describes the 6-way power divider to be used as a feeding structure of the waveguide array antenna generating the plane wave at the near distance. The SMA connector has been connected at the center of the power divider in order to feed the radiating element. The six output ports made of waveguide are positioned on the peripheral of the divider. This paper proposes the method utilizing the inductive post in order to decrease the return loss. The height of the feeding pin, the diameter of the inductive post, and the distance between the feeding pin and inductive post have been investigated, and as a result, the power divider has been optimized. The simulated and measured results show the low return loss of about -40 dB. The calculated and measured transmission coefficients are -7.78 dB and -8.06 dB, respectively. The output power of the six waveguide port show equal-amplitude and equal-phase distribution. Since the power divider proposed in this paper can be expanded to the divider having several output ports, it could be easily applied to the various array antennas.

Noninvasive Method to Distinguish between Glucose and Sodium Chloride Solution Using Complementary Split-Ring Resonator (Complementary Split Ring Resonator(CSRR)를 이용한 포도당과 염화나트륨 수용액의 비침습적 구별)

  • Jang, Chorom;Park, Jin-Kwan;Yun, Gi-Ho;Yook, Jong-Gwan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.4
    • /
    • pp.247-255
    • /
    • 2018
  • In this work, glucose solution and sodium chloride solution were distinguished noninvasively using a microwave complementary split-ring resonator (CSRR). Based on the electrical properties of the two solutions measured using a open-ended coaxial probe, a CSRR was designed and fabricated for operation at a specific frequency that facilitates differentiating the two solutions. Furthermore, a polydimethylsiloxane mold was fabricated to concentrate the solution at a region where the electric field of the resonator was strongest, and a laminating film was used to prevent contact between the solution and resonator. Experiments were performed by dropping $50{\mu}L$ of the solution in steps of 100 mg/dL up to a maximum human blood glucose level of 400 mg/dL. Our experiments confirmed that the transmission coefficients ($S_{21}$) of glucose solution and sodium chloride solution exhibit variations of -0.06 dB and 0.14 dB, respectively, per 100 mg/dL concentration change at the resonance frequency. Thus, the opposite trends in the variation of $S_{21}$ with change in the concentration of the two solutions can be used to distinguish between them.

Wavelet Image Coding according to the Activity Regions (활성 영역에 따른 웨이브렛 영상 부호화)

  • Park, Jeong-Ho;Kim, Dae-Jung;Gwak, Hun-Seong
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.39 no.2
    • /
    • pp.30-38
    • /
    • 2002
  • In this paper, we propose a new method for image coding which efficiently use the relationship between the properties of spatial image and its wavelet transform. Firstly, an original image is decomposed into several layers by the wavelet transform, and simultaneously decomposed into 2$^n$$\times$2$^n$blocks. Each block is classified into two regions according to their standard deviation, i.e., low activity region(LAR) and high activity region(HAR). The region with low frequency in spatial domain does not only appears as zero regions in wavelet frequency domain like HL, LH, and HH but also gives little influence to the quality of reconstructed image. The other side, the high frequency regions are related to significant coefficients which gives much influence to image reconstruction. In this paper, we propose a image coding method to obtain high compression rate at low bit rate by these properties. The LAR region is encoded by LAR coding method which is proposed in this paper, the HAR by a technique similar to bitplane coding in hierarchical tree. Simulation results show that th,$\boxUl$ proposed coding method has better performance than EZW and SPIHT schemes in terms of image quality and transmitted bit rates, can be successfully applied to the application areas that require of progressive transmission.

Dependences of Ultrasonic Parameters for Osteoporosis Diagnosis on Bone Mineral Density (골다공증 진단을 위한 초음파 변수의 골밀도에 대한 의존성)

  • Hwang, Kyo Seung;Kim, Yoon Mi;Park, Jong Chan;Choi, Min Joo;Lee, Kang Il
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.5
    • /
    • pp.502-508
    • /
    • 2012
  • Quantitative ultrasound technologies for osteoporosis diagnosis measure ultrasonic parameters such as speed of sound(SOS) and normalized broadband ultrasound attenuation(nBUA) in the calcaneus (heel bone). In the present study, the dependences of SOS and nBUA on bone mineral density in the proximal femur with high risk of fracture were investigated by using 20 trabecular bone samples extracted from bovine femurs. SOS and nBUA in the femoral trabecular bone samples were measured by using a transverse transmission method with one matched pair of ultrasonic transducers with a center frequency of 1.0 MHz. SOS and nBUA measured in the 20 trabecular bone samples exhibited high Pearson's correlation coefficients (r) of r = 0.83 and 0.72 with apparent bone density, respectively. The multiple regression analysis with SOS and nBUA as independent variables and apparent bone density as a dependent variable showed that the correlation coefficient r = 0.85 of the multiple linear regression model was higher than those of the simple linear regression model with either parameter SOS or nBUA as an independent variable. These high linear correlations between the ultrasonic parameters and the bone density suggest that the ultrasonic parameters measured in the femur can be useful for predicting the femoral bone mineral density.

Estimation of Structural Properties from the Measurements of Phase Velocity and Attenuation Coefficient in Trabecular Bone (해면질골에서 위상속도 및 감쇠계수 측정에 의한 구조적 특성 평가)

  • Lee, Kang-Il
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.7
    • /
    • pp.661-667
    • /
    • 2009
  • Trabecular-bone-mimicking phantoms consisting of parallel-nylon-wire arrays were used to investigate correlations of phase velocity and attenuation coefficient with structural properties in trabecular bone. Trabecular separation (Tb.Sp) of the 7 trabecular-bone-mimicking phantoms ranged from 300 to $900\;{\mu}m$ and volume fraction (VF) from 1.6% to 8.7%. Phase velocity and attenuation coefficient of the phantoms were measured by using a through-transmission method in water, with a matched pair of broadband unfocused transducers with a diameter of 12.7 mm and a center frequency of 1 MHz. Phase velocity and attenuation coefficient at 1 MHz decreased almost linearly with increasing Tb. Sp and increased almost linearly with increasing VF. The simple and multiple linear regression models with phase velocity and attenuation coefficient as independent vanables and Tb.Sp and VF as dependent variables demonstrated that the coefficients of determination for the prediction of VF were higher than those for the prediction of Tb.Sp. The results obtained in the trabecular-bone-mimicking phantoms consisting of parallel-nylon-wire arrays were consistent with those in human trabecular bone suggesting that the structural properties can be estimated from the measurements of phase velocity and attenuation coefficient in trabecular bone.