• Title/Summary/Keyword: Transmission Width

Search Result 371, Processing Time 0.027 seconds

Analysis of Capillary Flow in Open-Top Rectangular Microchannel (상판이 없는 직사각형 단면의 미세채널에서 모세관 유동 분석)

  • Park, Eun-Jung;Cho, Ji-Yong;Kim, Jeong-Chul;Hur, Dae-Sung;Chung, Chan-Il;Kim, Jung-Kyung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.1
    • /
    • pp.77-82
    • /
    • 2010
  • Our study aims to understand the flow of liquid in an open-top rectangular microchannel that can be used in micro total analysis systems ($\mu$-TAS) because it has advantages in terms of light transmission and energy efficiency. We measured the liquid velocity using particle tracking technique and conducted a simulation with computational fluid dynamics by altering the area of channel cross section and channel length for the capillary-driven flow in the open-top rectangular microchannel. When liquid water drops to an entrance of the fabricated microchannel with a height of 20 μm and a width of 20 ${\mu}m$, it flows along the microchannel by only capillary force. In the wetting behavior of the liquid, important parameters of this flow are channel size, contact angle and liquid properties such as surface tension and viscosity, which are used to control the flow of liquid in the microchannel.

Development of Birdcage Resonator for Various Absorption Regions at 3T (3T MRI에서 흡수영역의 변화에 따른 Birdcage Resonator의 개발)

  • 이정우;최보영;윤성익;이형구;서태석;허순녕
    • Progress in Medical Physics
    • /
    • v.15 no.1
    • /
    • pp.54-58
    • /
    • 2004
  • The aim of this study was to develop special birdcage resonators for small objects including the human wrist, hand and small animals, using 3T MRI/MRS. Before substantial development, different types of parameters were arranged, based on theoretical analysis, through lumped element transmission line theory. The primary analysis was peformed with a network analyzer (HP 4195A) and the final experimental analysis was carried out with 3T MRI (Medinus, Korea). The manufactured birdcage resonator is typically composed of 12-element structures to which a low-pass filter is fundamentally applied. The diameter and length of each element of the birdcage resonator were as follows: (1) diameter 12 cm, length of element 22 cm, (2) diameter 15 cm, length of element 22 cm, and (2) diameter 17 cm, length of element 25 cm. Copper tape with a width of 1 cm was used for the coils. MRI acquisition parameters were TR=500 ms, TE=17 ms, and Ave=2 for T1-WT images, and TR=4,000 ms, TE=96 ms, and Ave=2 for T2-WT images. The ratio of the samples diameter to the birdcage resonators diameter was approximately 55%, 63% and 70%, respectively, for the three elements. This study determined that the best image quality and S/N ratio were obtained when the ratio of the object's diameter was approximately 50∼80%. A general theoretical analysis of the birdcage coil differs in many respects from the experimental results which were influenced by many factors that were not considering when the general theoretical analysis of the birdcage coil was peformed. The induced resistance may be considered as part of the resistive loss if the quantitative value can be determined using a radiation resistance approach.

  • PDF

Property of Composite Titanium Silicides on Amorphous and Crystalline Silicon Substrates (아몰퍼스실리콘의 결정화에 따른 복합티타늄실리사이드의 물성변화)

  • Song Oh-Sung;Kim Sang-Yeob
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.13 no.1 s.38
    • /
    • pp.1-5
    • /
    • 2006
  • We prepared 80 nm-thick TiSix on each 70 nm-thick amorphous silicon and polysilicon substrate using an RF sputtering with $TiSi_2$ target. TiSix composite silicide layers were stabilized by rapid thermal annealing(RTA) of $800^{\circ}C$ for 20 seconds. Line width of $0.5{\mu}m$ patterns were embodied by photolithography and dry etching process, then each additional annealing process at $750^{\circ}C\;and\;850^{\circ}C$ for 3 hours was executed. We investigated the change of sheet resistance with a four-point probe, and cross sectional microstructure with a field emission scanning electron microscope(FE-SEM) and transmission electron microscope(TEM), respectively. We observe an abrupt change of resistivity and voids at the silicide surface due to interdiffusion of silicide and composite titanium silicide in the amorphous substrates with additional $850^{\circ}C$ annealing. Our result implies that the electrical resistance of composite titanium silicide may be tunned by employing appropriate substrates and annealing condition.

  • PDF

The New X-ray Induced Electron Emission Spectrometer

  • Yu.N.Yuryev;Park, Hyun-Min;Lee, Hwack-Ju;Kim, Ju-Hwnag;Cho, Yang-Ku;K.Yu.Pogrebitsky
    • Proceedings of the Korea Crystallographic Association Conference
    • /
    • 2002.11a
    • /
    • pp.5-6
    • /
    • 2002
  • The new spectrometer for X-ray Induced Electron Emission Spectroscopy (XIEES) .has been recently developed in KRISS in collaboration with PTI (Russia). The spectrometer allows to perform research using the XAFS, SXAFS, XANES techniques (D.C.Koningsberger and R.Prins, 1988) as well as the number of techniques from XIEES field(L.A.Bakaleinikov et all, 1992). The experiments may be carried out with registration of transmitted through the sample x-rays (to investigate bulk samples) or/and total electron yield (TEY) from the sample surface that gives the high (down to several atomic mono-layers in soft x-ray region) near surface sensitivity. The combination of these methods together give the possibility to obtain a quantitative information on elemental composition, chemical state, atomic structure for powder samples and solids, including non-crystalline materials (the long range order is not required). The optical design of spectrometer is made according to Johannesson true focusing schematics and presented on the Fig.1. Five stepping motors are used to maintain the focusing condition during the photon energy scan (crystal angle, crystal position along rail, sample goniometer rail angle, sample goniometer position along rail and sample goniometer angle relatively of rail). All movements can be done independently and simultaneously that speeds up the setting of photon energy and allows the using of crystals with different Rowland radil. At present six curved crystals with different d-values and one flat synthetic multilayer are installed on revolver-type monochromator. This arrangement allows the wide range of x-rays from 100 eV up to 25 keV to be obtained. Another 4 stepping motors set exit slit width, sample angle, channeltron position and x-ray detector position. The differential pumping allows to unite vacuum chambers of spectrometer and x-ray generator avoiding the absorption of soft x-rays on Be foil of a window and in atmosphere. Another feature of vacuum system is separation of walls of vacuum chamber (which are deformed by the atmospheric pressure) from optical elements of spectrometer. This warrantees that the optical elements are precisely positioned. The detecting system of the spectrometer consists of two proportional counters, one scintillating detector and one channeltron detector. First proportional counter can be used as I/sub 0/-detector in transmission mode or by measuring the fluorescence from exit slit edge. The last installation can be used to measure the reference data (that is necessary in XANES measurements), in this case the reference sample is installed on slit knife edge. The second proportional counter measures the intensity of x-rays transmitted through the sample. The scintillating detector is used in the same way but on the air for the hard x-rays and for alignment purposes. Total electron yield from the sample is measured by channeltron. The spectrometer is fully controlled by special software that gives the high flexibility and reliability in carrying out of the experiments. Fig.2 and fig.3 present the typical XAFS spectra measured with spectrometer.

  • PDF

Effects of the Ge Prearmophization Ion Implantation on Titanium Salicide Junctions (게르마늄 Prearmophization 이온주입을 이용한 티타늄 salicide 접합부 특성 개선)

  • Kim, Sam-Dong;Lee, Seong-Dae;Lee, Jin-Gu;Hwang, In-Seok;Park, Dae-Gyu
    • Korean Journal of Materials Research
    • /
    • v.10 no.12
    • /
    • pp.812-818
    • /
    • 2000
  • We studied the effects of Ge preamorphization (PAM) on 0.25$\mu\textrm{m}$ Ti-salicide junctions using comparative study with As PAM. For each PAM schemes, ion implantations are performed at a dose of 2E14 ion/$\textrm{cm}^2$ and at 20keV energy using $^{75}$ /As+and GeF4 ion sources. Ge PAM showed better sheet resistance and within- wafer uniformity than those of As PAM at 0.257m line width of n +/p-well junctions. This attributes to enhanced C54-silicidation reaction and strong (040) preferred orientation of the C54-silicide due to minimized As presence at n+ junctions. At p+ junctions, comparable performance was obtained in Rs reduction at fine lines from both As and Ge PAM schemes. Junction leakage current (JLC) revels are below ~1E-14 A/$\mu\textrm{m}^{2}$ at area patterns for all process conditions, whereas no degradation in JLC is shown under Ge PAM condition even at edge- intensive patterns. Smooth $TiSi_2$ interface is observed by cross- section TEM (X- TEM), which supports minimized silicide agglomeration due to Ge PAM and low level of JLC. Both junction break- down voltage (JBV) and contact resistances are satisfactory at all process conditions.

  • PDF

Growth of Blue Light Emitting InGaN/GaN MQWs by Metalorganic Chemical Vapor Deposition (유기금속화학기상증착법을 이용한 청색 발광 InGaN/GaN MQWs의 성장에 관한 연구)

  • Kim, Dong-Joon;Moon, Yong-Tae;Song, Keun-Man;Park, Seong-Ju
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.37 no.12
    • /
    • pp.11-17
    • /
    • 2000
  • We investigated the growth of InGaN/GaN multiple quantum wells (MQWs) structures which emit blue light. The samples were grown in a low pressure metalorganic chemical vapor deposition system. We examined InGaN/GaN MQWs by varying growth temperatures and thicknesses of InGaN well and GaN barrier layers in MQWs. Especially, the thickness of GaN barrier in InGaN/GaN MQWs was found to severely affect the interfacial abruptness between InGaN well and GaN barrier layers. The higher order satellite peaks in the high resolution x-ray diffraction spectra and the high resolution cross sectional transmission electron microscope image of MQW structrues revealed that the interface between InGaN and GaN layers was very abrupt. Room-temperature photoluminescence spectra also showed a blue emission from InGaN/GaN MQWs at the wavelength of 463.5nm with a narrow full width at half maximum of 72.6meV.

  • PDF

-1 Mode Circular Polarization Antenna Design by Using Cross Aperture-Coupled Feed (십자 개구 결합 급전을 이용한 -1 모드 원형 편파 안테나)

  • Kim, Jun-Sik;Lee, Jeong-Hae
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.2
    • /
    • pp.156-163
    • /
    • 2014
  • In this paper, a compact circularly polarized metamaterial patch antenna using cross aperture-coupled feed is proposed. The CP antenna utilizes the -1 mode that is induced by the composit right-left handed(CRLH) transmission line. Since the -1 mode has the same properties with the $TM_{010}$ mode of the conventional patch antenna, the circular polarization(CP) can be realized. If two orthogonal modes are excited with $90^{\circ}$ phase difference, the CP property can be obtained. In order to obtain two orthogonal modes and $90^{\circ}$ phase difference, 4 mushroom structures having the shape of square are employed. The width and length of the cross aperture are optimized through the design algorithm. The fabricated antenna is based on RT/duroid5880 substrate and the total area of the 4 mushroom is $0.25{\lambda}_0{\times}0.25{\lambda}_0$. The center frequency of the LHCP(Left-Handed Circular Polarization) antenna is measured as 1.622 GHz and circular polarization bandwidth(3 dB) is measured as 3 MHz. The center frequency of the RHCP(Right-Handed Circular Polarization) antenna is measured as 1.609 GHz and circular polarization bandwidth (3 dB) is measured as 3 MHz, respectively. The measured radiation efficiency of LHCP antenna is 61.1 % and the measured radiation efficiency of RHCP antenna is 54.5 %.

Development and utility evaluation of new Multi-Leaf Collimator for Diagnostic X-ray Equipment

  • Ji, Hoon;Han, Su Chul;Baek, Jong Hyeun;Lee, Dong Hoon;Park, Seungwoo
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.936-942
    • /
    • 2018
  • The diagnostic multi-leaf collimator preventing unnecessary dose from entering into patients during the diagnostic examination was made in this study. The movement of the entire 50 leaves was embodied with the group of 25 ones thereof configured in a pair facing each other on the left and right of the median line. Dimensions of the length, width, and height of each shielding leaf were $5{\times}0.5{\times}0.5cm^3$ resulting in the maximum boost field of $10{\times}10cm^2$. The material of multi-leaf collimator had the excellence on the machinability with the use of the SKD-11 alloy tool steel having the high wear resistance against frequent movement, and it was devised to control both-side's shielding leaves by moving 2 motors unlike existing remedial multi-leaf collimator that use as many motors as the number of 50 shielding leaves. Thereafter, the transmission dose of leaves, cross-leaf leakage dose, and inter-leaf leakage dose were measured by the developed multi-leaf collimator attached to X-ray equipment. An ionization chamber was used to detect doses there from, and the comparative analysis was carried out by means of the radiographic film that was easy to detect the dose leakage in between each leaf. Results obtained from the test conducted in comparative analysis yielded approximately 98%, 96%, and 94% of shielding efficiency realized at each level of energy of 80kV, 100kV, and 120kV it was confirmed there was no dose leakage resulted from the varied level of irradiation energy. Thus the multi-leaf collimator to be developed based on this study is thought that it could fully reduce the unnecessary dose to patients in the diagnostic test and the shielding efficiency thereof is expected to be increasing if it is made in a miniaturized form with a way of increasing the thickness of each leaf later for an extended application to general diagnostic purposes.

Transmission electron microscopic ultastructure of the tegument of Fibricola seoulenis (Fibricola seouenis 표피의 투과전자현미경적 미세구조)

  • 손운목;이순형
    • Parasites, Hosts and Diseases
    • /
    • v.31 no.4
    • /
    • pp.301-314
    • /
    • 1993
  • An electron microscopic study was performed to observe the ultrastructure of the tegument of U seoulensis. The outer surface of the tegument was covered with a tnlaminated plasma membrane. The electron-dense cytoplasmic layer was $2.5{\;}\mu\textrm{m}$ wide In the anterior portion and contained numerous vacuoles, mitochondriae and granular materials in its matrix. The basement layer was 330 nm wade or so, and Its numerous extensions protruded into the cytoplasmic layer. The sensory organ was composed of a small vesicle of $1.7{\;}{\times}{\;}1.1{\;}\mu\textrm{m}$ in dimensions, which possessed a cilium of $1.2{\;}{\times}{\;}0.19{\;}\mu\textrm{m}$ in size. The pharynx was composed of the epithelial layer of about $0.5{\;}\mu\textrm{m}$ wide, well developed muscle layer and basement layer. The tegument of the oral sucker was composed of a cytoplasmic layer of $0.4-0.5{\;}\mu\textrm{m}$ width, a narrow basement layer, a well developed muscle layer and tegumental cells. Some kinds of secretory granules that seemed to be originated from the cells of the oral sucker were observed In the parenchymal portions of the adjacent cells. The tribocytic organ consisted of numerous microvilli. The microvilli were 5 nm wide and heptalaminated. Two types of secretory granules originated from the gland cells of tribocytic organ were observed In the tegument and parenchyme. The tegumental cells were irregular in shape, and of which nuclei were multifarious.

  • PDF

Ansanella granifera gen. et sp. nov. (Dinophyceae), a new dinoflagellate from the coastal waters of Korea

  • Jeong, Hae Jin;Jang, Se Hyeon;Moestrup, Ojvind;Kang, Nam Seon;Lee, Sung Yeon;Potvin, Eric;Noh, Jae Hoon
    • ALGAE
    • /
    • v.29 no.2
    • /
    • pp.75-99
    • /
    • 2014
  • A small dinoflagellate, Ansanella granifera gen. et sp. nov., was isolated from estuarine and marine waters, and examined by light microscopy, scanning electron microscopy, and transmission electron microscopy. In addition, the identity of the sequences (3,663-bp product) of the small subunit (SSU), internal transcribed spacer (ITS) region (ITS1, 5.8S, ITS2), and D1-D3 large subunit (LSU) rDNA were determined. This newly isolated, thin-walled dinoflagellate has a type E eyespot and a single elongated apical vesicle, and it is closely related to species belonging to the family Suessiaceae. A. granifera has 10-14 horizontal rows of amphiesmal vesicles, comparable to Biecheleria spp. and Biecheleriopsis adriatica, but greater in number than in other species of the family Suessiaceae. Unlike Biecheleria spp. and B. adriatica, A. granifera has grana-like thylakoids. Further, A. granifera lacks a nuclear fibrous connective, which is present in B. adriatica. B. adriatica and A. granifera also show a morphological difference in the shape of the margin of the cingulum. In A. granifera, the cingular margin formed a zigzag line, and in B. adriatica a straight line, especially on the dorsal side of the cell. The episome is conical with a round apex, whereas the hyposome is trapezoidal. Cells growing photosynthetically are $10.0-15.0{\mu}m$ long and $8.5-12.4{\mu}m$ wide. The cingulum is descending, the two ends displaced about its own width. Cells of A. granifera contain 5-8 peripheral chloroplasts, stalked pyrenoids, and a pusule system, but lack nuclear envelope chambers, a nuclear fibrous connective, lamellar body, rhizocysts, and a peduncle. The main accessory pigment is peridinin. The SSU, ITS regions, and D1-D3 LSU rDNA sequences differ by 1.2-7.4%, >8.8%, and >2.5%, respectively, from those of the other known genera in the order Suessiales. Moreover, the SSU rDNA sequence differed by 1-2% from that of the three most closely related species, Polarella glacialis, Pelagodinium bei, and Protodinium simplex. In addition, the ITS1-5.8S-ITS2 rDNA sequence differed by 16-19% from that of the three most closely related species, Gymnodinium corii, Pr. simplex, and Pel. bei, and the LSU rDNA sequence differed by 3-4% from that of the three most closely related species, Protodinium sp. CCMP419, B. adriatica, and Gymnodinium sp. CCMP425. A. granifera had a 51-base pair fragment in domain D2 of the large subunit of ribosomal DNA, which is absent in the genus Biecheleria. In the phylogenetic tree based on the SSU and LSU sequences, A. granifera is located in the large clade of the family Suessiaceae, but it forms an independent clade.