• 제목/요약/키워드: Transmission Loss Coefficient

검색결과 114건 처리시간 0.032초

파랑 중 제주 "테우" 틈에 의한 파 흡수효과 (Efficiency of wave absorption by the porous of "Taewoo" of Jeju in regular seaway)

  • 이창헌;최찬문;안장영;조일형
    • 수산해양기술연구
    • /
    • 제49권2호
    • /
    • pp.144-152
    • /
    • 2013
  • In an effort to find the optimum porous of Taewoo through the mathematical model 2 - dimensional tank water experiment among the approached to a problem related to ocean engineering, this study analyzed the porosity by dividing it into 9 cases. As the wave penetrates through the longitudinal porous of the Taewoo model, it was found that there is a wave energy loss because of the phenomenon of the separation of the porous due to the eddy. Looking into the general tendency based on the wave-height meter (probe) data, it was found that the shorter wavelength and higher frequency area, the more reflection coefficients increased, but in contrast, the longer wavelength and lower frequency area, the transmission coefficients showed the increasing trend and energy dissipation was in a similar way with reflection coefficients. In addition, it was found that the bigger the porosity was, the narrower distribution range of reflection coefficients was, and the more its average value decreased. On the other hand the transmission coefficients in direct opposition to reflection was found to show the wider range and the more gradual increase in the average value as porosity was the bigger around the average value. In contrast, energy dissipation rate was found to increase linearly as porosity increased the more around the porosity of 0.2518 but it decreased gradually around the peak point. Through the above results, it is judged that the porous of optimum in the longitudinal direction of the Taewoo model perforated plate was about 2.6cm because it was found that the porosity which produced the lowest reflection and transmission coefficient and the highest energy dissipation. As a result of comparing this to the case where there was no porosity at all, it showed the function of wave absorbing about 31.60%.

Dielectric and Optical Properties of Amorphous Hafnium Indium Zinc Oxide Thin Films on Glass Substrates

  • Shin, Hye-Chung;Seo, Soon-Joo;Denny, Yus Rama;Lee, Kang-Il;Lee, Sun-Young;Oh, Suhk-Kun;Kang, Hee-Jae;Heo, Sung;Chung, Jae-Gwan;Lee, Jae-Cheol
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제41회 하계 정기 학술대회 초록집
    • /
    • pp.225-225
    • /
    • 2011
  • The dielectric and optical properties of GaInZnO (GIZO), HfInZnO (HIZO) and InZnO (IZO) thin films on glass by RF magnetron sputtering method were investiged using reflection electron energy loss spectroscopy (REELS). The band gap was estimated from the onset values of REELS spectra. The band gaps of GIZO, HIZO and IZO thin films are 3.1 eV, 3.5 eV and 3.0 eV, respectively, Hf and Ga incorporated into IZO results in an increase in the energy band gap of IZO by 0.5 eV and 0.1 eV. The dielectric functions were determined by comparing the effective cross section determined from experimental REELS with a rigorous model calculation based on the dielectric response theory, using available software package, good agreement between the experimental and fitting results gives confidence in the accuracy of the determined dielectric function. The main peak of Energy Loss Function (ELF) obtained from IZO shows at 18.42 eV, which shifted to 19.43 eV and 18.15 eV for GIZO and HIZO respectively, because indicates the corporation of cation Ga and Hf in the composition. The optical properties represented by the dielectric function e, the refractive index n, the extinction coefficient k, and the transmission coefficient, T of HIZO and IZO thin films were determined from a quantitative analysis of REELS. The transmission coefficient was increased to 93% and decreased to 87% in the visible region with the incorporation of Hf and Ga in the IZO compound.

  • PDF

간척지 설치 온실의 난방부하 특성 분석 (Analysis of Heating Load Characteristics for Greenhouses Constructed in Reclaimed Lands)

  • 남상운;신현호
    • 한국농공학회논문집
    • /
    • 제59권6호
    • /
    • pp.1-8
    • /
    • 2017
  • The purpose of this study was to provide basic data for development of environmental design technology for greenhouses constructed in reclaimed lands. We analyzed the climatic conditions around seven major reclaimed land areas in Korea, which have a plan to install advanced horticultural complexes. The characteristics of heating load through the thermal environment measurement of the greenhouse in Saemangeum were analyzed. The part to be applied to the environmental design of the greenhouses in reclaimed lands were reviewed. The overall heat transfer coefficient of the experimental greenhouse with the aluminum screen and multi-layer thermal curtain averaged $3.79W/m^2^{\circ}C$. It represents a 44 % heat savings rate compared with plastic greenhouses with a single covering, which was significantly lower than that of the common greenhouses with 2-layer thermal curtains. This is because the experimental greenhouse was installed on reclaimed land and wind was stronger than the inland area. Among the total heating load, the transmission heat loss accounted for 96.4~99.9 %, and the infiltration loss and the ground heat exchange were low. Therefore, it is necessary to take countermeasures to minimize the transmission heat loss for greenhouses constructed in reclaimed lands. As the reclaimed land is located on the seaside, the wind is stronger than the inland area, and the fog is frequent. Especially, Saemangeum area has 2.6 times stronger wind speed and 3.4 times longer fog duration than the inland area. In designing the heating systems for greenhouses in reclaimed lands, it is considered that the maximum heating load should be calculated by applying the wind coefficient larger than the inland area. It is reasonable to estimate the operation cost of the heating system by applying the adjustment factor 10 % larger than the average in calculating the seasonal heating load.

Wave-blocking Efficiency of a Horizontal Porous Flexible Membrane

  • Cho, Il-Hyoung
    • 한국해양공학회지
    • /
    • 제17권1호
    • /
    • pp.8-15
    • /
    • 2003
  • 본 논문에서는 투과성 유연막이 수면밑 일정한 깊이에 수평으로 잠겨있을 때 투과성 유연막에 의한 파랑제어성능을 살펴보았다. 해석 방법으로는 유체문제는 고유함수전개법 (Eigenfunction expansion method)을 사용하였고, 유연막과 파랑의 상호작용문제는 Newmann 이 제시한 유탄성 이론 (hydro-elastic theory)을 채택하였다. 막의 투과성 효과를 고려하기 위하여 수평막에서의 수직속도는 수평막 상하의 압력차에 선형적으로 비례하며 그들 사이에는 위상차가 없다고 가정한 Darcy 법칙을 사용하였다. 투과성 수평막의 설계변수 (초기장력, 길이, 잠긴 깊이, 공극율)와 입사파의 주파수를 바꿔가면서 반사율과 투과율 그리고 에너지 손실율을 살펴보았다.

Wave-blocking Efficiency of a Horizontal Porous Flexible Membrane

  • Cho, Il-Hyoung
    • International Journal of Ocean Engineering and Technology Speciallssue:Selected Papers
    • /
    • 제6권1호
    • /
    • pp.7-14
    • /
    • 2003
  • The interaction of monochromatic incident waves with a submerged horizontal porous membrane is investigated in the context of two-dimensional linear hydro-elastic theory. It is assumed that the membrane is made of material with very fine pores so that the normal velocity of the fluid passing through the porous membrane is linearly proportional to the pressure difference between two sides of the membrane (e.g. Darcy's law). Using the Eigen-function expansion method, the wave-blocking performance of a submerged horizontal porous membrane is tested with various membrane tensions, porosities, lengths, and submerged depths. It is found that an optimal combination of design parameters exists for given water depth and wave characteristics.

  • PDF

밸브 형식별 유량제어범위 결정에 관한 연구 (Study of Flow Control Range according to Valve Type)

  • 박종호;박한영
    • 한국유체기계학회 논문집
    • /
    • 제14권5호
    • /
    • pp.39-47
    • /
    • 2011
  • Flow control range of valve, which is installed on pipeline, varies according to valve type, pipe diameter, pipe length, roughness, and elevation difference of both ends of pipeline. A lot of computation efforts and knowledge are needed to estimate flow control range of valve, considering above many parameters. The table of flow control range of each valve type is presented for convenience of pipeline design engineers who must make decision of valve size and type in this study. Also the reason that butterfly valve is recommended for flow control, and gate valve is forbidden is presented via quantification and figures in this study.

KRISS에서 수행된 음향관련 교정 및 시험 동향 (Tendency of Calibration and Test for Acoustic Field in KRISS)

  • 서재갑;권휴상;정성수;조문재;서상준
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.448-452
    • /
    • 2002
  • We report the number of calibration and test for acoustic field which were conducted in KRISS between the year of 1990 and 2001. The items contain sound level meter and calibrator for calibration and sound absorption coefficient, transmission loss, sound pressure level of siren, sound pressure level and power of acoustic instrument and relative accessories for test. The data show that the number of them have been increased continuously.

  • PDF

방음실에 의한 공장설비 소음의 감쇠 효과에 관한 연구 (A Study on Sound Attenuation of Plant Noise by Enclosure)

  • 윤세철;이해경
    • 한국안전학회지
    • /
    • 제9권4호
    • /
    • pp.119-124
    • /
    • 1994
  • The considerations in the noise control by enclosure are the rise of temperature and sound pressure, transmission loss, absorption coefficient of the materials, the structure of the soundproof panels, an opening and coincidence frequency. But it is very difficult that we obtain the accurate data about those in design, so, the noise reduction after enclosing does not correspond with the calculation. The difference of the noise reduction between the calculation and the measurement was 8.2dBA, and we can obtain the approximate result as the following formula which correct 10dBA, safely.

  • PDF

ENHANCEMENT THE SOUND TRANSMISSION LOSS OF POROELASTIC LININGS

  • Song, B.Heuk-Jin;Bolton, J.Stuart
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.606-611
    • /
    • 2000
  • It has been noted that the low frequency absorption coefficient of a porous sample placed in a standing wave tube is affected by the nature of the sample's edge constraint. The edge constraint has the effect of stiffening the solid phase of the sample, which itself can be strongly coupled to the material's fluid phase, and hence the incident sound field, by viscous means at low frequencies. In recent work it has also been shown that such a circumferential constraint causes the low frequency transmission loss of a layer of fibrous material to approach a finite low frequency limit that is proportional to the flow resistance of the layer and which is substantially higher than that of an unconstrained sample of the same material. However, it was also found that the benefit of the circumferential edge constraint was reduced in a transitional frequency range by a shearing resonance of the sample. Here it will be shown that the effect of that resonance can be mitigated or eliminated by adding additional axial and radial constraints running through the sample. It will also be shown that the constraint effect can be modeled closely by using a finite element procedure based on the Biot poroelastic theory. Implications for low frequency barrier design are also discussed.

  • PDF

The Effect of Gas Environment on the Electronic and Optical Properties of Amorphous Indium Zinc Tin Oxide Thin Films

  • Denny, Yus Rama;Lee, Sun-Young;Lee, Kang-Il;Seo, Soon-Joo;Oh, Suhk-Kun;Kang, Hee-Jae;Heo, Sung;Chung, Jae-Gwan;Lee, Jae-Cheol;Tougaard, Seven
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제43회 하계 정기 학술대회 초록집
    • /
    • pp.141-141
    • /
    • 2012
  • The electronic and optical properties of Indium Zinc Tin Oxide (IZTO) thin films using gas environment were investigated by X-ray photoelectron spectroscopy (XPS) and reflection electron energy loss spectroscopy (REELS). REELS spectra revealed that the band gaps of IZTO thin films are 3.26, 3.07, and 3.46 eV for water mixed with oxygen, argon mixed with oxygen, and air environments, respectively. The measured band gaps by REELS are consistent with the optical band gaps obtained by UV-Spectrometer. The optical properties represented by the dielectric function $\mathfrak{m}$, the refractive index n, the extinction coefficient k, and the transmission coefficient T of the IZTO thin films with different gas environments were determined from a quantitative analysis of REELS spectra. The calculated transmission from quantitative analysis of REELS spectra shows good agreement with transmission measured by UV-spectrometer. The transmission values of 89% and low electrical resistivity of $3.55{\times}10^{-3}{\Omega}{\cdot}cm$ have been achieved for argon mixed with oxygen which indicates that the gas enviroment plays an important role in improving the electronic and optical properties of films.

  • PDF