• Title/Summary/Keyword: Transmission Line Method

Search Result 1,068, Processing Time 0.037 seconds

The SAG Behavior of Overhead Conductor due to Forest Fire (산불에 의해 가열된 가공송전선의 이도거동)

  • Kim, Byung-Geol;Kim, Shang-Shu;Jun, Wan-Gi;Han, Se-Won;Kim, Jin-Han
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.516-517
    • /
    • 2007
  • Because forest fire can give a serious damage to overhead conductors, the thorough understanding about sag behavior of burned conductor is very important in maintaining the transmission line safely. Therefore, a systematic investigation was carried out by heating method. As the heating temperature increases, drastic change of tensile strength of Al wire due to the softening of Al wire occurred. When Al wire is exposed to the flame(about $800^{\circ}C$) during only 13 seconds, the remained tensile strength of Al wire showed under 90%. and then sag of overhead conductor become deteriorated. The detailed results will be given in the text.

  • PDF

Comparison of the Poor Insulator Detecting Technique for the Reliability Enhancement of the Electric Power Facilities (전력설비의 신뢰성 향상을 위한 불량애자검출기법의 비교)

  • Jung, Soon-Won;Koo, Kyung-Wan
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.4
    • /
    • pp.417-423
    • /
    • 2008
  • For the evaluation in the safety of outdoor insulator, there are various methods such as: visual observation; voltage measurement; use of ultrasonic wave due to partial discharge; electric field measurement; use of infrared/ultraviolet sensor-type camera. However, many problems have been issued regrading the reliability of the evaluation test and safety of testing operation. Accordingly, the present study has investigated and analyzed the characteristics and mechanisms of the insulator deterioration, in order to obtain an optimal method for detecting poor insulator so that the reliability of power facilities can be enhanced. Besides, based on theoretical analysis of domestic and international detection methods for poor insulator, the reliability has been compared and evaluated quantitatively. As a result, it was shown that the corona camera would be the best choice for domestic workplace application in detecting poor insulator for enhancing the reliability of power transmission line.

A study on the computer diagnosis that apply Neural-Fuzzy algorithm accumulation detection of Partial Discharge signal (부분방전 신호의 누적검출과 뉴럴-퍼지 알고리즘을 이용한 컴퓨터 진단에 관한 연구)

  • Hwang, Kyoung-Jun;Yeoum, Keoung-Tae;Kim, Yong-Kab;Kim, Jin-Su
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1445-1446
    • /
    • 2007
  • In this paper, we have studied for analysis of the partial discharge(PD) signal in power transmission line. The PD signal has estimated as detected signal accumulation of a PRPDA method by using Labview, and analyzed with neural-fuzzy algorithm. With practical PD logic implementation of theoretical detected system and hardware implementation, the device for Hipotronics Company's 22.9kV or 154kV setup have generated and then have applied with 18kV,20kV with 1:1 time probe. It's also used the LDPE 0.27mmt (scratch error 0.05mmt) to sample for making PD. Our new class of PD detected algorithm have also compared with previous PRPDA or Neural Fuzzy algorithm, which has diagnose more conveniently by adding numerical values.

  • PDF

A method of underground transmission line power cable transport & pulling Installation For long distance span (지중송전 장조장 케이블 운반 및 포설공법개발)

  • Oh, Jang-Man;Bae, Joo-Ho;Bang, Hang-Kwon;Min, Byeong-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.663-664
    • /
    • 2007
  • 지중송전선로 건설공사에 154kV 장조장 케이블 드럼개발 및 트레일러 일체형 Under Roller 방식을 이용한 포설장비를 개발하여 현장에 적용함으로써 신기술 신개발 공법 적용으로 인한 국제경쟁력 향상 뿐만 아니라 접속경간의 장조장 설계로 케이블 접속개소 감소로 인한 공사비절감과 공사기간 단축에 크게 기여하였다. 이와 동시에 공사를 위한 도로점용 단축으로 민원발생을 크게 감소시켰다. 현행 도로법 규제로 케이블의 운반중량이 제한되었던 케이블 표준 경간을 450m에서 최대 700m까지 가능하여 접속개소의 유연성이 확보되었을 뿐만 아니라 토목구조물(전력구,관로등)공사의 다양한 설계방법을 적용할 수 있게 되었다.

  • PDF

Multi-Layered Optimal VAR Planning (조상설비 최적화를 위한 다단계 방안)

  • Hur, Jin;Lee, Byoung-Jun;Song, Kil-Yeong
    • Proceedings of the KIEE Conference
    • /
    • 1998.11a
    • /
    • pp.273-275
    • /
    • 1998
  • This paper presents a method of determining the minimum amount of reactive power capacity installation and minimizing transmission line losses. It deals with maintaining voltage profile within an acceptable range with respect to the increase in load demand. Our approach provides three-different stages to power system planner. First stage considers existing capacitors. Second stage considers expanding the size of the installed capacitors. Third stage considers existing capacitors and newly installed capacitors whose locations are irrelevant to the locations of existing ones. Validity and effectiveness of the proposed algorithm are confirmed by results on modified New England 30 bus test system.

  • PDF

The Aging Behavior of Overhead Conductor due to Forest Fire (산불에 의한 가공송전선의 열화거동)

  • Kim, Byung-Geol;Kim, Shang-Shu;Jun, Wan-Gi;Han, Se-Won
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.534-535
    • /
    • 2007
  • Because forest fire can give a serious damage to overhead conductors, the thorough understanding about aging behavior of burned conductor is very important in maintaining the transmission line safely. Therefore, a systematic investigation was carried out by heating method. As the heating temperature increases, drastic change of tensile strength of Al wire due to the softening of Al wire occurred. When Al wire is exposed to the flame(about $800^{\circ}C$) during only 13 seconds, the remained tensile strength of Al wire showed under 90%. The detailed results will be given in the text.

  • PDF

Design of New Attenuator Structure with Quad Spiral sHaped Defected Ground Structure

  • Jeong Yongwoo;ong Young-Joo;Park Hyung-Sik;Ahn Dal
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.5 no.5
    • /
    • pp.403-408
    • /
    • 2004
  • We suggest new attenuator design and formula using quad spiral shaped defected ground structure (DGS). Series resistors and quarter wavelength transmission line that has a role of inverter have been synthesized for attenuator design and novel attenuator structure using quad spiral shaped DGS is fabricated, the measurements show good agreement with theoretical anticipations. The suggested attenuator could remove peak of insertion loss graph through various attenuation method. The various attenuations are obtained by attached pin-diodes, 10-15dB attenuation leveling is realized for validity of suggested design.

  • PDF

DRAM Package Substrate Using Aluminum Anodization (알루미늄 양극산화를 사용한 DRAM 패키지 기판)

  • Kim, Moon-Jung
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.4
    • /
    • pp.69-74
    • /
    • 2010
  • A new package substrate for dynamic random access memory(DRAM) devices has been developed using selective aluminum anodization. Unlike the conventional substrate structure commonly made by laminating epoxy-based core and copper clad, this substrate consists of bottom aluminum, middle anodic aluminum oxide and top copper. Anodization process on the aluminum substrate provides thick aluminum oxide used as a dielectric layer in the package substrate. Placing copper traces on the anodic aluminum oxide layer, the resulting two-layer metal structure is completed in the package substrate. Selective anodization process makes it possible to construct a fully filled via structure. Also, putting vias directly in the bonding pads and the ball pads in the substrate design, via in pad structure is applied in this work. These arrangement of via in pad and two-layer metal structure make routing easier and thus provide more design flexibility. In a substrate design, all signal lines are routed based on the transmission line scheme of finite-width coplanar waveguide or microstrip with a characteristic impedance of about $50{\Omega}$ for better signal transmission. The property and performance of anodic alumina based package substrate such as layer structure, design method, fabrication process and measurement characteristics are investigated in detail.

Electrical Characteristics of Copper Circuit using Inkjet Printing (잉크젯 프린팅 방식으로 형성된 구리 배선의 전기적 특성 평가)

  • Kim, Kwang-Seok;Koo, Ja-Myeong;Joung, Jae-Woo;Kim, Byung-Sung;Jung, Seung-Boo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.17 no.3
    • /
    • pp.43-49
    • /
    • 2010
  • Direct printing technology is an attractive metallization method, which has become immerging as "Green technology" to the conventional photolithography, on account of low cost, simple process and environment-friendliness. In order to commercialize the printed electronics in industry, it is essential to evaluate the electrical properties of conductive circuits using direct printing technology. In this contribution, we focused on the electrical characteristics of inkjet-printed circuits. A Cu nanoink was inkjet-printed onto a Bisaleimide triazine(BT) substrate with parallel transmission line(PTL) and coplanar waveguide(CPW) type, then was sintered at $250^{\circ}C$ for 30 min. We calculated the resistivity of printed circuits through direct current resistance by the measurement of I-V curve: the resistivity was approximately 0.558 ${\mu}{\Omega}{\cdot}cm$ which is about 3.3 times that of bulk Cu. Cascade's probe system in the frequency range from 0 to 30 GHz were employed to measure the Scattering parameter(S-parameter) with or without a gap between the substrate and the probe station chuck. The result of measured S-parameter showed that all printed circuits had over 5 dB of return loss in the entire frequency range. In the curve of insertion loss, $S_{21}$, showed that the PTL type circuits had better transmission of radio frequency (RF) than CPW type.

Analysis of Packet Transmission Delay in the DC Power-Line Fault Management System using IEEE 802.15.4 (IEEE 802.15.4를 적용한 직류배전선로 장애관리시스템에서 패킷전송 지연시간 분석)

  • Song, Han-Chun;Hwang, Sung-Ho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.1
    • /
    • pp.259-264
    • /
    • 2014
  • IEEE 802.15.4 has been emerging as the popular choice for various monitoring and control applications. In this paper, a fault management system for DC power-lines has been designed using IEEE 802.15.4, in order to monitor DC power-lines in real time, and to rapidly detect faults and shut off the line where such faults occur. Numbers were allocated for each node and unslotted CSMA-CA method of IEEE 802.15.4 was used, the performance of which was analyzed by a simulation. For such purpose, a total of 60 bits of the control data consisting of 16 bits of the current, 16 bits of the amplitude, 28 bits of the terminal state data were sent out, and the packet transfer rate and the transmission delay time of the fault management system for DC power-lines were measured and analyzed. When the traffic load was 330 packets per second or lower, the average delay time was shown to be shorter than 0.02 seconds, and when the traffic load was 260 packets per second or lower, the packet transfer rate was shown to be 99.99% or higher. Therefore, it was confirmed that the stringent condition of US Department of Energy (DOE) could be satisfied if the traffic load was 260 packets per second or lower, The results of this study can be utilized as basic data for the establishment of the fault management system for DC power-lines using IEEE 802.15.4.