• 제목/요약/키워드: Transmission Line Method

검색결과 1,068건 처리시간 0.061초

A Metamodeling Approach for Leader Progression Model-based Shielding Failure Rate Calculation of Transmission Lines Using Artificial Neural Networks

  • Tavakoli, Mohammad Reza Bank;Vahidi, Behrooz
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권6호
    • /
    • pp.760-768
    • /
    • 2011
  • The performance of transmission lines and its shielding design during a lightning phenomenon are quite essential in the maintenance of a reliable power supply to consumers. The leader progression model, as an advanced approach, has been recently developed to calculate the shielding failure rate (SFR) of transmission lines using geometrical data and physical behavior of upward and downward lightning leaders. However, such method is quite time consuming. In the present paper, an effective method that utilizes artificial neural networks (ANNs) to create a metamodel for calculating the SFR of a transmission line based on shielding angle and height is introduced. The results of investigations on a real case study reveal that, through proper selection of an ANN structure and good training, the ANN prediction is very close to the result of the detailed simulation, whereas the Processing time is by far lower than that of the detailed model.

Calculation on the Ion Flow Field under HVDC Transmission Lines Considering Wind Effects

  • Wu, Jing;Gao, Sheng;Liu, Yuxiao
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권5호
    • /
    • pp.2077-2082
    • /
    • 2015
  • Based on Deutsch assumption, a calculation method on the electric field over the ground surface under HVDC transmission lines in the wind is proposed. Analyzing the wind effects on the electric field and the space charge density the existing method based on Deutsch assumption is improved through adding the wind speed to the ion flow field equations. The programming details are illustrated. The calculation results at zero wind speed are compared with available data to validate the code program. Then the ionized fields which resulted from corona of ±800kV HVDC lines are analyzed. Both the electric field and the current density on the ground level are computed under different wind direction and speed. The computation results are in good agreement with measurements. The presented method and code program can be used to rapidly predict and evaluate the wind effects in HVDC transmission engineering.

Pulse Propagation Analysis of High Speed Transmission Lines using the Phenomenological Loss Equivalence Method (현상학적 도체 손실 등가 기법을 이용한 고속 전송선의 펄스 전송 특성 해석)

  • 홍정기;이해영;민형복
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • 제32A권3호
    • /
    • pp.25-37
    • /
    • 1995
  • The phenomenological loss equivalence method incorporated into the wideband lossy transmission line model is applied to the characterization of high desity digital transmission lines. The pulse propagation characteristics are analyzed using the calculated frequency characteristics and the discrete Fourier transformation. This approach has been verified by comparing the calculated frequency characteristics with the FEM and the esperimental results. This method is very suitable for computer-aided analysis of high density/high speed interconnection circuits because of the simple calculation as well as the calculation accuracy. We have found that pulse ftransmission speed and dispersion of hgih density digital transmission lines can be optimized by managing the conductor and dielectric losses in addition to the impedance matching.

  • PDF

Estimation for the Transfer Function of Transmission Line using the Temination and Input Impedances at Activated/Deactivated states (활성/비활성 상태에서의 종단과 입력 임피던스 변화를 이용한 전송선로의 전달함수 추정)

  • 이종헌;진용옥
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • 제17권1호
    • /
    • pp.90-97
    • /
    • 1992
  • An estimation method for the amplitude and phase response of transmission line is discussed. and applied to narrow band ISDN subscriber line. The ABCD parameters of line are evaluated from four impedance values: the standard termination impedence at activated and deactivated stares, and the input impedances of line which can be estimated at each state. Estimating input impedence, the “chirp” signal is used as incident signal and noise effect can be reduced by ensemble averaging. These ABCD parameter estimations might be applicable to ether uniform or nonuniform line. Cleary the magnitude and phase response can be obtained from estimated ABCD parameters. The numerical simulation results for N ISDN subscriber line model are included, and the estimation error introduced by deviation in load impedence is also anlyzed.

  • PDF

Fault Line Detection Methodology for Four Parallel Lines on the Same Tower

  • Li, Botong;Li, Yongli;Yao, Chuang
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권4호
    • /
    • pp.1217-1228
    • /
    • 2014
  • A method for faulted line detection of four parallel lines on the same tower is presented, based on four-summing and double-differential sequences of one terminal current. Four-summing and double-differential sequences of fault current can be calculated using a certain transformation matrix for parameter decoupling of four parallel transmission lines. According to fault boundary conditions, the amplitude and phase characteristics of four-summing and double-differential sequences of fault current is studied under conditions of different types of fault. Through the analysis of the relationship of terminal current and fault current, a novel methodology for fault line detection of four parallel transmission line on the same tower is put forward, which can pick out the fault lines no matter the fault occurs in single line or cross double lines. Simulation results validate that the methodology is correct and reliable under conditions of different load currents, transient resistances and fault locations.

Regional Grouping of Transmission System Using the Sequential Clustering Technique (순차적 클러스터링기법을 이용한 송전 계통의 지역별 그룹핑)

  • Kim, Hyun-Houng;Lee, Woo-Nam;Park, Jong-Bae;Shin, Joong-Rin;Kim, Jin-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • 제58권5호
    • /
    • pp.911-917
    • /
    • 2009
  • This paper introduces a sequential clustering technique as a tool for an effective grouping of transmission systems. The interconnected network system retains information about the location of each line. With this information, this paper aims to carry out initial clustering through the transmission usage rate, compare the similarity measures of regional information with the similarity measures of location price, and introduce the techniques of the clustering method. This transmission usage rate uses power flow based on congestion costs and similarity measurements using the FCM(Fuzzy C-Mean) algorithm. This paper also aims to prove the propriety of the proposed clustering method by comparing it with existing clustering methods that use the similarity measurement system. The proposed algorithm is demonstrated through the IEEE 39-bus RTS and Korea power system.

Analysis of the Sleeve Dipole Array Antennas Using the Moment Method (모멘트 법을 이용한 슬리브 다이폴 배열안테나의 해석)

  • 배남진;최학근
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • 제10권7호
    • /
    • pp.973-984
    • /
    • 1999
  • This paper presents a method of moments with the transmission line theory to analyze the sleeve dipole array antennas and analyses characteristics of that. There were several considerations for analysis of the method of moments. First, the method of moments were applied at both of the sleeve dipole elements and the coaxial line because the current flows on both of them. Second, the feed voltages of each sleeve dipole element were obtained by using a transmission line theory because the feeding structure is fed by coaxial line in series. Third, the series reactance between the coaxial line and the open side of the sleeve was considered as impedance loading on the antenna. The radiation patterns and current distributions from the numerical results were considered as variation of the feed distances and frequencies. To verify the validity of our method, 4 elements sleeve dipole array antennas with 1 λg distance were fabricated and measured, and then the measured radiation patterns were compared with the numerical results. The measured results were confirmed a good agreement with the numerical results.

  • PDF

Improvement of Attenuation Characteristics for Multiple Coupled Line Structure on the Specific Lossy Media (특정 손실 매질위의 다중 결합선로에 대한 손실특성 개선)

  • Kim, Yoon-Suk;Kim, Min-Su
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • 제48권12호
    • /
    • pp.35-41
    • /
    • 2011
  • In this paper, an analysis for a new substrate shielding symmetric coupled MIS structure consisting of grounded crossbar at the interface between Si and SiO2 layer using the Finite-Difference Time-Domain(FDTD) method is presented. In order to reduce the substrate effects on the transmission line characteristics, a shielding structure consisting of grounded crossbar lines over time-domain signal has been examined. Parameters of symmetric coupled MIS transmission line with various gaps between crossbars for even- and odd-mode are investigated as the functions of frequency, and the extracted distributed frequency-dependent transmission line parameters and corresponding equivalent circuit parameters as well as quality factor for the new MIS crossbar embedded structure are also presented. It is shown that the quality factor of the symmetric coupled transmission line can be improved without significant change in the characteristic impedance and effective dielectric constant.

FM Reflectometric Measurement of Group Velocities of Microwave Transmission Lines

  • Park, Yong-Hyun;Lee, Jeong-Hae
    • Journal of electromagnetic engineering and science
    • /
    • 제3권1호
    • /
    • pp.67-71
    • /
    • 2003
  • In this paper, frequency modulated(FM) reflectometry is proposed to measure group velocity of microwave transmission line Various microwave transmission lines such as periodically loaded conducting posts in a waveguide and nonradiative dielectric(NRD) guide are adopted to measure their group velocity The result compared with that from network analyzer shows good agreement, indicating the validity of our measurement method.

A Study on Design of Multivariable Equalizer for Transmission Distortion Compensation (전송왜곡보상용 다중가변등화기 설계에 관한 연구)

  • 김동석;최규훈;문홍진;김종교
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • 제27권6호
    • /
    • pp.921-928
    • /
    • 1990
  • A multivariable equalizer is designed which compensates transmission distortion for coaxial transmission line. The characteristic transfer function with bilateral parameter domain is approximated using the expansion method of orthonormal function and Gram Schmidt orthogonal function, but the parameter domain of approximated function is limited to unilateral. To solve that problem, Bode type transfer function is used to give bilateral variable characteristic to approximated function. The multivariable equalizer in this paper can be substituted for the current equalizer which consist of a fixed equalizer and a variable equalizer.

  • PDF