• 제목/요약/키워드: Transmission Line Method

검색결과 1,065건 처리시간 0.026초

배관 압력을 이용한 서보밸브 정적 특성에 관한 실험적 연구 (An Experimental Study on Static Characteristics of Servo Valves using Transmission Line Pressures)

  • 김성동;주별진;윤소남
    • 드라이브 ㆍ 컨트롤
    • /
    • 제13권2호
    • /
    • pp.42-50
    • /
    • 2016
  • The conventional technique to measure the hysteresis and the null of servo valves is defined in ISO 10770-1 and based on load flow signal of the servo valve. A new technique based on the transmission line pressures is suggested in this study. The new measuring method was verified through a series of experiments. No hysteresis was observed between the spool displacement and the transmission line pressures, load pressure or each chamber pressure. Some hysteresis was observed between valve input and pressures, which was found to be the same as those of load flow and spool displacement for the valve input. By using the chamber pressures, the hysteresis and the null are easier to measure than the load pressure or differential pressure between those two chamber pressures because the chamber pressures showed sharp edges.

비공진형 협벽 도파관 슬롯 배열 설계를 위한 효율적인 슬릇 어드미턴스 추출 방법에 관한 연구 (A Study on the Efficient Extraction of Slot Admittance for the Design of a Non-Resonant Waveguide Edge Slot Array)

  • 박종국;한기진;나형기;김찬홍;이동국
    • 한국전자파학회논문지
    • /
    • 제19권11호
    • /
    • pp.1223-1232
    • /
    • 2008
  • 본 논문에서는 비공진형 협벽 도파관 슬롯 배열 설계를 위해 필요한 기준이 되는 단위 슬롯 어드미턴스를 해석적으로 추출하는 방법을 제시하였다. 충분한 개수의 동일 기울임 각을 가지는 교번 슬롯 구조에 대해, 도파관 협벽의 단위 슬롯과 단위 슬롯 양쪽에 이웃한 전송선 부분을 균일한 손실 전송선으로 근사하고, 이로부터 손쉽게 전체의 ABCD 행렬을 계산하여 전체의 시뮬레이션 또는 측정값과 비교함으로써, 손실 전송선의 복소 특성 임피던스와 복소 전파 상수를 구하고 해석 적으로 정규화 된 슬롯 어드미턴스를 추출하였다. 제안한 방법의 타당성을 입증하기 위해, 대역 협벽 도파관 슬롯 배열 설계용으로 제작된 기준 슬롯 도파관 샘플의 정규화 된 슬롯 어드미턴스를 구하고 기존의 방법으로 얻은 값과 비교하여 잘 일치함을 보였다.

Simulation of nonstationary wind in one-spatial dimension with time-varying coherence by wavenumber-frequency spectrum and application to transmission line

  • Yang, Xiongjun;Lei, Ying;Liu, Lijun;Huang, Jinshan
    • Structural Engineering and Mechanics
    • /
    • 제75권4호
    • /
    • pp.425-434
    • /
    • 2020
  • Practical non-synoptic fluctuating wind often exhibits nonstationary features and should be modeled as nonstationary random processes. Generally, the coherence function of the fluctuating wind field has time-varying characteristics. Some studies have shown that there is a big difference between the fluctuating wind field of the coherent function model with and without time variability. Therefore, it is of significance to simulate nonstationary fluctuating wind field with time-varying coherent function. However, current studies on the numerical simulation of nonstationary fluctuating wind field with time-varying coherence are very limited, and the proposed approaches are usually based on the traditional spectral representation method with low simulation efficiency. Especially, for the simulation of multi-variable wind field of large span structures such as transmission tower-line, not only the simulation is inefficient but also the matrix decomposition may have singularity problem. In this paper, it is proposed to conduct the numerical simulation of nonstationary fluctuating wind field in one-spatial dimension with time-varying coherence based on the wavenumber-frequency spectrum. The simulated multivariable nonstationary wind field with time-varying coherence is transformed into one-dimensional nonstationary random waves in the simulated spatial domain, and the simulation by wavenumber frequency spectrum is derived. So, the proposed simulation method can avoid the complicated Cholesky decomposition. Then, the proper orthogonal decomposition is employed to decompose the time-space dependent evolutionary power spectral density and the Fourier transform of time-varying coherent function, simultaneously, so that the two-dimensional Fast Fourier transform can be applied to further improve the simulation efficiency. Finally, the proposed method is applied to simulate the longitudinal nonstationary fluctuating wind velocity field along the transmission line to illustrate its performances.

765kV급 송전선로 공기절연거리 설정을 위한 시험전극의 섬락전압 특성 (The Flashover Characteristics of Test Electrodes against Clearance of Air Insulation for 765kV Transmission Line)

  • 김윤택;김영배;이형호;김정문;김정부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1337-1340
    • /
    • 1995
  • For the purpose of rational design of air insulation, it is need to experiment with similar to real shape test object and conform the characterisics. But basic distances of air insulation of transmission line, tower, etc. can be acquired from flashover characteristic of rod-rod, rod-plane electrodes. In this paper, before field test of 765kV transmission line for determination of distances of phase to ground insulation, we execute lightning, switching impulse test with test electrod(rod-rod, rod-plane) against clearances of air insulation. Each tests use up-down method and consist of 30 times flashover test. Flashover data treatment program and air correction program following IEC 60-1(1987) standard were completely builted.

  • PDF

ANSYS를 이용한 송전용 자기재 애자의 장력에 따른 특성 변화 (A Variation of Maximum Stress with Axial Loading in Porcelain Insulators for Transmission Line using ANSYS)

  • 우병철;한세원;조한구
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 유기절연재료 방전 플라즈마연구회
    • /
    • pp.104-107
    • /
    • 2003
  • The ageing cause in many porcelain suspension insulators which occur on transmission and distribution line with dead-end stings is mechanical stress in interface between porcelain and cement materials. It is known that the principal mechanical stress which give electrical failure is the results of the displacement is due to cement growth. We studied an analysing method to find out a deformation of brittle porcelain with a thermal expansion of cement for suspension insulator. These simulation analysis and experimental results show that cement volume growths affect severely to be mechanical failure ageing. These simulation analysis and experimental results show that axial loading affects of Porcelain insulators severely to be mechanical failure ageing.

  • PDF

혼합송전선로에서 고저항 지락사고시 케이블 과도현상 해석 및 전력케이블 시스 접지저항에 따른 CCPU 과도특성 모의 (Modeling and Transient Analysis of Cable in Combined Transmission Line with HIF and Analysis of Transient Characterstic in CCPU of Uderground Cable)

  • 정채균;이종범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.446-448
    • /
    • 2000
  • This paper discribes the modeling and transient analysis of cable in combined transmission line under high impedance fault(HIF). And also, transient characterstic analyzed on cable covering protection unit(CCPU) is presented. Modeling of the combined transmission line is established in PSCAD/EMTDC V3. The required data to analyze the transient phenomena is given from the actual system. The results show the HIF modeling in cable, fault current according to the value of fault resistance. And also when the value and method of grounding resistance is changed in CCPU, simulation results are presented.

  • PDF

Data Transmission over Power Line with Lightning Protection Devices

  • Kim, Sungeon;Jeon, Taehyun
    • International journal of advanced smart convergence
    • /
    • 제2권1호
    • /
    • pp.27-29
    • /
    • 2013
  • This paper discusses comparative analysis of the effects of surge protection devices (SPD) upon the power line communication channels. The quality of the data transmission channel is measured based on the data rate for the various channel parameters which include channel length and application method of the lightning protection device. The performance measurements are also carried out for various lengths of the communication channel. Experiment results show that specific combination of SPDs applied in the network causes severe degradation of the channel quality which is associated with the combination of grade levels and channel lengths.

Transformer Winding Modeling based on Multi-Conductor Transmission Line Model for Partial Discharge Study

  • Hosseini, Seyed Mohammad Hassan;Baravati, Peyman Rezaei
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권1호
    • /
    • pp.154-161
    • /
    • 2014
  • To study and locate partial discharge(PD) and analyze the transient state of power transformer, there is a need for a high frequency model of transformer winding and calculation of its parameters. Due to the high frequency nature of partial discharge phenomenon, there is a need for an accurate model for this frequency range. To attain this goal, a Multi-Conductor Transmission Line (MTL) model is used in this paper for modeling this transformer winding. In order that the MTL model can properly simulate the transformer behavior within a frequency range it is required that its parameters be accurately calculated. In this paper, all the basic parameters of this model are calculated by the use of Finite Element Method (FEM) for a 20kV winding of a distribution transformer. The comparison of the results obtained from this model with the obtained shape of the waves by the application of PD pulse to the winding in laboratory environment shows the validity and accuracy of this model.

전송선로를 가진 Chua 회로에서의 카오스 현상 해석 (Analysis of Chaotic Phenomena with Transmission line of Chua's Circuit)

  • 고재호;배영철;임화영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 B
    • /
    • pp.533-535
    • /
    • 1997
  • Chua's circuit is a simple electronic network which exhibits a variety of bifurcation and attractors. The circuit consists of two capacitors, an inductor, a linear resistor, and a nonlinear resistor. In this paper we analyze a circuit obtained by replacing the parallel LC resonator in the Chua's circuit by lossless transmission line. By using the method of characteristics of this circuit we show that various periodic motions and chaotic motions can the attained according to parameter variations. From Chua's circuit with a lossless transmission line, a variety of chaotic attractors which are similar to those of the normal Chua's circuit are observed.

  • PDF