• 제목/요약/키워드: Translucency parameter

검색결과 31건 처리시간 0.023초

Effect of immersion into solutions at various pH on the color stability of composite resins with different shades

  • Moon, Ji-Deok;Seon, Eun-Mi;Son, Sung-Ae;Jung, Kyoung-Hwa;Kwon, Yong-Hoon;Park, Jeong-Kil
    • Restorative Dentistry and Endodontics
    • /
    • 제40권4호
    • /
    • pp.270-275
    • /
    • 2015
  • Objectives: This study examined the color changes of a resin composite with different shades upon exposure to water with different pH. Materials and Methods: Nanohybrid resin composites (Filtek Z350XT, 3M ESPE) with four different shades (A2, A3, B1, and B2) were immersed in water with three different pH (pH 3, 6, and 9) for 14 day. The CIE $L^*a^*b^*$ color coordinates of the specimens were evaluated before and after immersion in the solutions. The color difference (${\Delta}E^*$) and the translucency parameter (TP) were calculated using the color coordinates. Results: ${\Delta}E^*$ ranged from 0.33 to 1.58, and the values were affected significantly by the pH. The specimens immersed in a pH 6 solution showed the highest ${\Delta}E^*$ values (0.87 - 1.58). The specimens with a B1 shade showed the lowest ${\Delta}E^*$ change compared to the other shades. TP ranged from 7.01 to 9.46 depending on the pH and resin shade. The TP difference between before and after immersion in the pH solutions was less than 1.0. Conclusions: The resulting change of color of the tested specimens did not appear to be clinically problematic because the color difference was < 1.6 in the acidic, neutral, and alkaline solutions regardless of the resin shade, i.e., the color change was imperceptible.

광중합 전후 복합레진의 광학적 특성 (Optical characteristics of resin composite before and after polymerization)

  • 엄아향;김덕수;이수희;변창원;박노훈;최경규
    • Restorative Dentistry and Endodontics
    • /
    • 제36권3호
    • /
    • pp.219-230
    • /
    • 2011
  • 연구목적: 복합레진의 광중합 전후에 일어나는 색과 투명도 변화를 측정하고, CQ의 함량을 정량하였으며, 광중합 전후 복합 레진의 굴절률을 측정해 이들의 상관 관계를 알아보고자 하였다. 연구 재료 및 방법: Esthet-X, Filtek supreme, Gradia Direct, Clearfil Majesty, Beautifil II에 대하여 Colorimeter NF999를 이용하여 광중합 전후의 색과 투명도를 각각 측정하고, GC-MS를 이용해 각 복합레진의 CQ 함량을 측정하였으며, spectroscopic ellipsometer를 이용해 광중합 전후의 굴절률을 측정하였다. 결과: 투명도는 광중합 후에 증가하였고, body shade에서 opaque shade보다 투명도 차이가 크게 나타났다. 모든 레진에서 body shade의 CQ 함량이 opaque shade의 CQ 함량보다 높았다. 굴절률은 광중합 후에 모든 레진에서 증가하였으며, body shade와 opaque shade간에 굴절률의 변화는 유의한 차이가 있었다. 결론: 광중합 후에는 복합레진의 색과 투명도가 상당한 차이를 나타낸다. 따라서 임상에서 direct shade matching을 시행할 때는 중합된 레진을 사용하여야 한다.

Influences of luting cement shade on the color of various translucent monolithic zirconia and lithium disilicate ceramics for veneer restorations

  • Ghada Alrabeah;Nawaf Alamro;Atif Alghamdi;Ahmed Almslam;Meshari Azaaqi
    • The Journal of Advanced Prosthodontics
    • /
    • 제15권5호
    • /
    • pp.238-247
    • /
    • 2023
  • PURPOSE. The purpose of this study was to assess the effect of resin cement shade on the color of different novel ultratranslucent monolithic zirconia and lithium disilicate veneer materials. MATERIALS AND METHODS. For a total of 40 specimens, flat cylindrical discs with a 9-mm diameter and 0.5-mm thickness were created using CAD/CAM technology. The specimens were divided into five groups according to their material (n = 8) (e.max, Prettau, Aidite, Shofu and Dima) using A1 shade. Resin discs with the same diameter and shade as the specimens served as tooth-colored substructures. Three shades (neutral, light and warm) of resin cement try-in pastes (Variolink Esthetic LC) were used as the luting cement material. The color of each material group was measured before and after cementation using the three cement shades, and the CIE L*a*b* coordinates were obtained with a spectrophotometer. Values for the translucency parameter (TP) and color change delta E (E) before (baseline) and after cementation of each specimen were determined. To compare differences among the material groups within each shade of cement and among various shades of cement within each material, the data were analyzed using one-way ANOVA and post hoc testing. RESULTS. Color coordinates L*, a* and b* significantly changed after the application of try-in pastes relative to baseline values, with a noticeable decrease in lightness (L*) (P < .05). A significant color change (ΔE) was observed in all tested materials after cementation, with ΔE values exceeding 3.3 (P < .05). Although TP changed after cementation for most materials tested, these changes were not statistically significant (P > .05). Shofu and Dima ceramics showed the lowest TP values, while Aidite and Prettau showed the highest TP values. For e.max, translucency decreased after cementation with neutral and warm shades, and it significantly increased after cementation with a light shade. CONCLUSION. The shade of cement significantly altered the final color of the ceramic veneer material to a level above the threshold at which the clinical perception of color change occurred (> 3.3). The TP was not influenced by the cement shade. The translucency levels of the novel ultratranslucent multilayer monolithic zirconia ceramics Aidite and Prettau were higher than that of the lithium disilicate e.max material.

Physicochemical characterization of two bulk fill composites at different depths

  • Guillermo Grazioli ;Carlos Enrique Cuevas-Suarez ;Leina Nakanishi ;Alejandro Francia;Rafael Ratto de Moraes
    • Restorative Dentistry and Endodontics
    • /
    • 제46권3호
    • /
    • pp.39.1-39.12
    • /
    • 2021
  • Objectives: This study analyzed the physical-chemical behavior of 2 bulk fill resin composites (BFCs; Filtek Bulk Fill [FBF], and Tetric-N-Ceram Bulk Fill [TBF]) used in 2- and 4-mm increments and compared them with a conventional resin composite (Filtek Z250). Materials and Methods: Flexural strength and elastic modulus were evaluated by using a 3-point bending test. Knoop hardness was measured at depth areas 0-1, 1-2, 2-3, and 3-4 mm. The translucency parameter was measured using an optical spectrophotometer. Real-time polymerization kinetics was analyzed using Fourier transform infrared spectroscopy. Results: Flexural strength was similar among the materials, while TBF showed lower elastic modulus (Z250: 6.6 ± 1.3, FBF: 6.4 ± 0.9, TBF: 4.3 ± 1.3). The hardness of Z250 was similar only between 0-1 mm and 1-2 mm. Both BFCs had similar hardness until 2-3 mm, and showed significant decreases at 3-4 mm (FBF: 33.45 ± 1.95 at 0-1 mm to 23.19 ± 4.32 at 3-4 mm, TBF: 23.17 ± 2.51 at 0-1 mm to 15.11 ± 1.94 at 3-4 mm). The BFCs showed higher translucency than Z250. The polymerization kinetics of all the materials were similar at 2-mm increments. At 4-mm, only TBF had a similar degree of conversion compared with 2 mm. Conclusions: The BFCs tested had similar performance compared to the conventional composite when used in up to 2-mm increments. When the increment was thicker, the BFCs were properly polymerized only up to 3 mm.

The effects of repetitive firing processes on the optical, thermal, and phase formation changes of zirconia

  • Ozdogan, Alper;Ozdemir, Hatice
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권1호
    • /
    • pp.9-14
    • /
    • 2020
  • PURPOSE. The aim of this study was to investigate the effect of different numbers of heat treatments applied to superstructure porcelain on optical, thermal, and phase formation properties of zirconia. MATERIALS AND METHODS. Forty zirconia specimens were prepared in the form of rectangular prism. Specimens were divided into four groups (n = 10) according to the number of firing at heating values of porcelain. Color differences and translucency parameter were measured, and X-ray diffraction (XRD) analysis and differential scanning calorimetry (DSC) were performed. Data were analyzed with analysis of variance (ANOVA). RESULTS. There were no statistically significant differences in ∆E, TP, L, a, and b value changes of the zirconia specimens as a result of repetitive firing processes (P>.05). CONCLUSION. Although additional firing processes up to 4 increase peak density in thermal analysis, additional firing processes up to 4 times can be applied safely as they do not result in a change in color and phase character of zircon frameworks.

레진시멘트 색상이 상용 지르코니아 크라운의 색상에 미치는 영향 (Effect of resin cement color on the color of commercially available zirconia crown)

  • 하현승;임범순;이상훈
    • 대한치과재료학회지
    • /
    • 제45권4호
    • /
    • pp.233-242
    • /
    • 2018
  • 본 연구의 목적은 레진시멘트 색상이 상용 지르코니아 크라운의 색상에 미치는 영향을 평가하는 것이다. 연구에는 $NuSmile^{(R)}$ ZR Zirconia LT Shade (LT) 지르코니아와 $RelyX^{TM}$ U200 TR, A2, A3O (TR, A2, A3O) 레진시멘트를 사용했다. 이 때 지르코니아와 레진시멘트 시편은 직경 5 mm, 두께 1 mm의 디스크 형으로 각 조건 당 다섯 개씩 제작했다. CIE $L^*a^*b^*$값은 검은색과 흰색 배경에서 분광 광도계를 사용해 지르코니아와 레진시멘트 단독 조건과 겹친 조건에서 각각 측정했다. 레진시멘트 색상이 상용 지르코니아 크라운의 색상에 미치는 영향은 측정된 값을 이용해, 반투명도(TP, translucency parameter), 대조비(CR, contrast ratio), 색차(${\Delta}E{^*}_{ab}$)의 계산을 통해 평가했다. 각 변수에 대한 평균값과 표준편차는 동일한 실험군에서 CIE $L^*a^*^b^*$ 값을 3회씩 측정하여 구했다. 실험군의 통계적 유의성은 일원배치 분산분석(one-way ANOVA)과 Tukey-multiple comparisons test로 검증했다. 그 결과, 지르코니아 하방에 레진시멘트를 겹친 조건일 때는 지르코니아 단독 조건일 때에 비해 반투명도는 감소했고(p<0.05) 대조비는 증가했다. 검은색 배경에서 지르코니아와 지르코니아 하방에 레진시멘트를 겹쳤을 때의 색차는 모든 실험군에서 색의 변화를 인지할 수 없었고 LT/A3O 조합에서 최소값을 보였다. 한편, 흰색 배경에서 지르코니아와 지르코니아 하방에 레진시멘트를 겹쳤을 때의 색차는 LT/TR 조합에서 색변화를 임상적으로 허용할 수 있는 경계값을 보였다. LT/A2 조합에서는 색변화를 임상적으로 허용할 수 없었고, LT/A3O 조합에서는 색변화를 인지할 수 있었으나 임상적으로 허용할 수 있는 수준이었다. 이상의 결과와 같이 본 연구의 한계 내에서는, 흰색 배경의 LT/A2 조합 외에는 지르코니아 색상에 임상적으로 허용할 수 없는 색변화를 주는 레진시멘트는 없었다. 그 중 지르코니아 색상에 최소한의 영향을 미치는 레진시멘트 색상은 A3O였다. 따라서, 본 연구와 동일한 상용 지르코니아 크라운을 치아에 접착할 때 색변화를 최소화하기 위해서는 A3O 색상의 레진시멘트 사용이 추천된다.

다운증후군위험도 예측에서 통합선별검사를 이용한 파라미터의 유의성 (Guideliness of the Parameters Using Integrated Test in Down Syndrome Risk Prediction)

  • 이진원;고성진;강세식;김창수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권4호
    • /
    • pp.549-555
    • /
    • 2016
  • 본 연구는 다운증후군 위험도의 예측을 위해 통합선별검사를 실시한 산모를 대상으로, 각 표지자의 유의성에 대한 평가를 하였다. 초음파로 측정한 NT 영상, 산모혈청 PAPP-A, AFP, uE3, hCG, 인히빈 A의 상관성을 후향적으로 분석하였다. 그 결과 NT, uE3, hCG, 인히빈 A와 유의한 상관관계를 보였다(p<.001). ROC분석에서 인히빈 A의 AUC가 0.851로 다운증후군의 가장 큰 예측인자로 분석되었으며. cut-off value 1.33 MoM(민감도 87.5%, 특이도 71.5%)으로 결정되었다. 결론적으로 통합선별검사에서 인히빈 A가 다운증후군을 예측하는 가장 유용한 인자로 나타났다. 이에 각 표지자(parameter)들의 cut-off value를 바탕으로 통합선별검사의 단점을 보완한다면 다운증후군 선별의 독립적인 지표로 사용될 수 있을 것으로 사료된다.

Discoloration of various CAD/CAM blocks after immersion in coffee

  • Lauvahutanon, Sasipin;Shiozawa, Maho;Takahashi, Hidekazu;Iwasaki, Naohiko;Oki, Meiko;Finger, Werner J.;Arksornnukit, Mansuang
    • Restorative Dentistry and Endodontics
    • /
    • 제42권1호
    • /
    • pp.9-18
    • /
    • 2017
  • Objectives: This study evaluated color differences (${\Delta}Es$) and translucency parameter changes (${\Delta}TPs$) of various computer-aided design/computer-aided manufacturing (CAD/CAM) blocks after immersion in coffee. Materials and Methods: Eight CAD/CAM blocks and four restorative composite resins were evaluated. The CIE $L^{\ast}a^{\ast}b^{\ast}$ values of 2.0 mm thick disk-shaped specimens were measured using the spectrophotometer on white and black backgrounds (n = 6). The ${\Delta}Es$ and ${\Delta}TPs$ of one day, one week, and one month immersion in coffee or water were calculated. The values of each material were analyzed by two-way ANOVA and Tukey's multiple comparisons (${\alpha}=0.05$). The ${\Delta}Es$ after prophylaxis paste polishing of 1 month coffee immersion specimens, water sorption and solubility were also evaluated. Results: After one month in coffee, ${\Delta}Es$ of CAD/CAM composite resin blocks and restorative composites ranged from 1.6 to 3.7 and from 2.1 to 7.9, respectively, and ${\Delta}TPs$ decreased. The ANOVA of ${\Delta}Es$ and ${\Delta}TPs$ revealed significant differences in two main factors, immersion periods and media, and their interaction except for ${\Delta}Es$ of TEL (Telio CAD, Ivoclar Vivadent). The ${\Delta}Es$ significantly decreased after prophylaxis polishing except GRA (Gradia Block, GC). There was no significant correlation between ${\Delta}Es$ and water sorption or solubility in water. Conclusions: The ${\Delta}Es$ of CAD/CAM blocks after immersion in coffee varied among products and were comparable to those of restorative composite resins. The discoloration of CAD/CAM composite resin blocks could be effectively removed with prophylaxis paste polishing, while that of some restorative composites could not be removed.

치과용 지르코니아의 광학적 성질에 영향을 미치는 요소에 대한 문헌고찰 (Review on factors affecting the optical properties of dental zirconia)

  • 박찬호;고경호;박찬진;조리라;허윤혁
    • 구강회복응용과학지
    • /
    • 제37권4호
    • /
    • pp.177-185
    • /
    • 2021
  • 기존의 3 mol%의 이트라아(Y2O3)로 안정화된 정방정 지르코니아(3 mol% yttria stabilized tetragonal zirconia polycrystal, 3Y-TZP) 뿐만 아니라 이트리아 함량이 증가된 반투명 지르코니아(translucent zirconia)를 이용한 단일구조 지르코니아 보철물의 사용이 증가하면서 치과용 지르코니아의 광학적 성질에 영향을 미치는 요소에 대한 연구가 지속적으로 이루어지고 있다. 이트리아 함량, 보철물 두께, 소결과정, 연마 및 광택소성 그리고 치과용 시멘트 등과 같은 치과기공실 및 진료실 과정의 처리 방법에 따라 치과용 지르코니아의 광학적 효과가 다르게 나타난다. 이트리아 농도의 증가는 반투명도의 개선과 동시에 차폐효과의 감소를 유발할 수 있으며 수복물 두께가 증가할수록 반투명도는 감소하지만 지르코니아 블록의 물성에 따라 요구되는 두께가 다르므로 주의해야 한다. 고속소결 방식은 제작시간을 단축시키나 경우에 따라 보철물의 반투명도가 감소할 수 있다. 지르코니아의 표면거칠기 및 광택소성 처리에 따라 광학적 결과도 영향을 받을 수 있다. 적절한 유색 시멘트의 사용은 지르코니아의 차폐효과에 도움이 되어 보다 자연스러운 보철치료가 가능하다.

고반투명 유색 지르코니아의 굽힘강도와 신뢰도에 대한 연구 (Flexural strength and reliability of highly translucent colored zirconia)

  • 공현준
    • 구강회복응용과학지
    • /
    • 제36권1호
    • /
    • pp.41-47
    • /
    • 2020
  • 목적: 본 연구의 목적은 전부도재 수복물을 위해 단일체로 사용되는 고반투명 유색 지르코니아의 굽힘강도 및 신뢰도를 평가하기 위함이다. 연구 재료 및 방법: 전부도재 수복물을 위해 사용되는 무색(A0) 및 유색(A1, A3)의 고반투명 지르코니아 블록을 사용하여 바 형태의 시편(25 × 4 × 2.5 mm)을 제작하였다. 지르코니아 블록의 색조에 따라 3개의 실험군을 설정하였고, 한 군당 20개의 시편을 제작하였다. 굽힘강도는 3점 굽힘시험을 통해 측정하였으며, 일원배치 분산분석을 이용하여 색조에 따른 통계적 유의성을 검증하였다. 다음으로 세라믹 재료 특성상 신뢰도를 평가하기 위해 와이블 분석을 시행하였으며, X선 회절분석으로 시편의 결정특성을 분석하였다. 결과: 무색 고반투명 지르코니아의 굽힘강도(1127.10 MPa)가 색조 A1 (995.71 MPa)과 A3 (1016.42 MPa)에 비해 통계학적으로 유의하게 높은 값을 보였다(P < 0.05). 색조 A1과 A3 사이에는 유의한 차이가 없었다(P > 0.05). 와이블 분석을 시행한 결과, 무색 고반투명 지르코니아가 유색에 비해 높은 신뢰도를 나타냈다. X선 회절분석 결과 모든 그룹에서 지르코니아 정방정상의 특징적인 피크를 보였다. 결론: 본 제한된 연구의 결과를 근거로 단일체로 사용되는 고반투명 지르코니아에 색조를 가미하는 것이 굽힘강도와 신뢰도를 저하시킬 수 있으며, 도재 파절을 방지하고 심미 증진을 위해 고반투명 지르코니아를 사용할 경우 색조 선택에 주의를 기울여야 할 것이다.