• Title/Summary/Keyword: Transient response method

Search Result 594, Processing Time 0.025 seconds

Geometrically nonlinear thermo-mechanical analysis of graphene-reinforced moving polymer nanoplates

  • Esmaeilzadeh, Mostafa;Golmakani, Mohammad Esmaeil;Kadkhodayan, Mehran;Amoozgar, Mohammadreza;Bodaghi, Mahdi
    • Advances in nano research
    • /
    • v.10 no.2
    • /
    • pp.151-163
    • /
    • 2021
  • The main target of this study is to investigate nonlinear transient responses of moving polymer nano-size plates fortified by means of Graphene Platelets (GPLs) and resting on a Winkler-Pasternak foundation under a transverse pressure force and a temperature variation. Two graphene spreading forms dispersed through the plate thickness are studied, and the Halpin-Tsai micro-mechanics model is used to obtain the effective Young's modulus. Furthermore, the rule of mixture is employed to calculate the effective mass density and Poisson's ratio. In accordance with the first order shear deformation and von Karman theory for nonlinear systems, the kinematic equations are derived, and then nonlocal strain gradient scheme is used to reflect the effects of nonlocal and strain gradient parameters on small-size objects. Afterwards, a combined approach, kinetic dynamic relaxation method accompanied by Newmark technique, is hired for solving the time-varying equation sets, and Fortran program is developed to generate the numerical results. The accuracy of the current model is verified by comparative studies with available results in the literature. Finally, a parametric study is carried out to explore the effects of GPL's weight fractions and dispersion patterns, edge conditions, softening and hardening factors, the temperature change, the velocity of moving nanoplate and elastic foundation stiffness on the dynamic response of the structure. The result illustrates that the effects of nonlocality and strain gradient parameters are more remarkable in the higher magnitudes of the nanoplate speed.

Aneurysms Presenting with Neural Compression : Response to Treatment with Guglielmi Detachable Coils Embolization (뇌동맥류에 의한 신경 압박의 GDC 색전 치료 반응)

  • Park, Jin Young;Ahn, Jung Yong;Huh, Ryoong;Choi, Hun Kyu;Lee, Byung Hee;Shin, Moon Soo;Chung, Bong Sub
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.11
    • /
    • pp.1491-1498
    • /
    • 2000
  • Objectives : Embolization of intracranial aneurysms by using Guglielmi detachable coils(GDC) is proving to be a safe method of protecting aneurysms from rupture. Occasionally, patients with unruptured intracranial aneurysms present with symptoms related to the aneurysm's mass effect on either the brain parenchyma or cranial nerves. In the present study, the authors conducted a retrospective review to evaluate the response to GDC embolization in a series of 6 patients presenting with cranial nerve dysfunction due to mass effect. Patients and Methods : Aneurysms were classified by size, shape, and amount of intraluminal thrombus. Patients were classified by duration of symptoms prior to GDC treatment(range<1 month to>4 years). Clinical assessment was performed within days of the GDC procedure and at later follow-up appointments(range 5-16 months, mean 9 months). Results : In the immediate post-GDC embolization period, one of the five patients had transient worsening of third nerve palsy, which later improved to better than baseline status. Two patients who presented with third nerve deficit from a internal carotid artery-posterior communicating artery junction aneurysm had complete recovery. One patient who presented with hemiparesis and dysarthria from a giant mid-basilar aneurysm showed improvement of these symptoms. One patient who presented with sixth cranial nerve deficit from a cavernous aneurysm showed no change at the 8-months follow-up examination. Conclusion : The endovascular treatment of intracranial aneurysms by using GDC is suggested as an alternative therapeutic method for improving or alleviating neurological deficits produced by mass effect.

  • PDF

Leukocyte-Endothelial Cell Adhesion Induced by Ischemia and Reperfusion Observed with in vivo Videomicroscopy (허혈-재관류에 의해 유도된 백혈구-혈관내피세포 유착에 대한 Videomicroscopy 영상소견)

  • Lee, Young Bae;Kang, Han Sug;Park, Shin Byung
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.10
    • /
    • pp.1289-1295
    • /
    • 2000
  • Purpose : Recent evidence suggests a possible role for leukocytes in brain injury following ischemia and reperfusion. This study examined the temporal profile of ischemic tissue damage and leukocyte response after transient middle cerebral artery occlusion(MCAO) with reperfusion in the mouse. Methods : Focal cerebral ischemia was made by temporary occluding of the stem of the proximal MCA. Two groups of the mouse were investigated : (1) sham operation(n=10), and (2)those having the arterial occlusion released after 90 minute(n=20). By 4 hours(n=10) and 24 hours(n=10) after the onset of ischemia-reperfusion, fluorescein videoimages were under-taken in the pial venules of the mouse using a closed cranial window technique. Rhodamine 6G was administered as a $80-100{\mu}l/min$ i.v. loading dose and a $30-40{\mu}l/min$ i.v. maintenance dose in saline to selectively label circulating leukocytes. Neuropathologic evaluation for brain injury was accomplished using the histochemical stain 2,3,5-triphen-yltetrazolium chloride(TTC) and hematoxylin and eosin(H & E) stain. Results : The mean number of adherent leukocytes to cerebral venules in the 90 minutes MCAO and 24 hours reperfusion group were $306{\pm}24$ compared with $72{\pm}8$ in the sham operation group. In the TTC staining method, the cortical infarct affecting 34.8% of hemispheric volume were created in all of animals (n=10) undergoing 90 minute MCAO with 24 hours reperfusion, but the infarcted area were not found in the other(sham operation and 90 minute MCAO with 4 hours reperfusion)groups. In the H & E stain, the brain tissue following 90 minute MCAO with 4 hours reperfusion revealed only a pyknosis of the nuclei with shrunken cytoplasm, but infiltrated leukocytes were not observed. After 24 hours of reperfusion, a many leukocytes were infiltrated within parenchyma and blood vessles. Conclusions : These findings demonstrate the feasiblity of continous in vivo monitoring of leukocyte adherence in cerebral venules and suggest that reperfusion induced leukocyte adherence to venular endothelium may contribute to tissue injury following focal cerebral ischemia.

  • PDF

Development of Wireless Smart Sensing Framework for Structural Health Monitoring of High-speed Railway Bridges (고속 철도 교량의 구조 건전성 모니터링을 위한 스마트 무선 센서 프레임워크 개발)

  • Kim, Eunju;Park, Jong-Woong;Sim, Sung-Han
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.5
    • /
    • pp.1-9
    • /
    • 2016
  • Railroad bridges account for 25% of the entire high-speed rail network. Railway bridges are subject to gradual structural degradation or fatigue accumulation due to consistent and repeating excitation by fast moving trains. Wireless sensing technology has opened up a new avenue for bridge health monitoring owing to its low-cost, high fidelity, and multiple sensing capability. On the other hand, measuring the transient response during train passage is quite challenging that the current wireless sensor system cannot be applied due to the intrinsic time delay of the sensor network. Therefore, this paper presents a framework for monitoring such transient responses with wireless sensing systems using 1) real-time excessive vibration monitoring through ultra-low-power MEMS accelerometers, and 2) post-event time synchronization scheme. The ultra-low power accelerometer continuously monitors the vibration and trigger network when excessive vibrations are detected. The entire network of wireless smart sensors starts sensing through triggering and the post-event time synchronization is conducted to compensate for the time error on the measured responses. The results of this study highlight the potential of detecting the impact load and triggering the entire network, as well as the effectiveness of the post-event time synchronized scheme for compensating for the time error. A numerical and experimental study was carried out to validate the proposed sensing hardware and time synchronization method.

DYNAMIC 3-DIMENSIONAL FINITE ELEMENT ANALYSIS OF MANDIBULAR FRACTURE MECHANISM (충격하중(衝擊荷重)과 하악골(下顎骨) 골절발생(骨折發生) 기전(機轉)의 유한요소법적(有限要素法的) 연구(硏究))

  • Oh, Seung-Hwan;Kim, Yeo-Gab
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.18 no.3
    • /
    • pp.470-487
    • /
    • 1996
  • The purpose of this study was to investigate the dynamic response of the mandible to impact and provide insight into the fracture mechanism of the mandible, by 3-dimensional finite element method. The finite element model of the mandible was developed and calculated using NASTRAN/XL (MSC co. U.S.A.) and the linear dynamic transient analysis was performed according to the impulsive force direction, force type and impulse time to the mandible. At first, the load was applied on the mandibular symphysis, body, angle and subcondylar area in the horizontal mandibular plane and the computed stress-time histories at 14 locations of the mandible were obtained. Secondly, the impulsive force was directed to the symphyseal area with changing the force magnitude and impulse time, and calculated the node displacement at 8 locations of mandible. The conclusions from from this study were as follows. 1. The appearance of impulsive energy transmission was different to the direction of impulse to the mandible. 2. The impulsive stress and deformation were larger in lingual or medial side than buccal or lateral in the mandible. 3. The velocity, appearance of energy transmission and the fracture pattern in mandible were affected rather impulse time than force. 4. The horizontal impact to the one side of mandible did not have effect on the stress and displacement of contralateral mandible. From the above results, fracture pattern in symphysis can be showed as simple or comminuted, multiple or associated in body and angle and solitary in subcondyle area.

  • PDF

Design of Controller for Rapid Thermal Process Using Evolutionary Computation Algorithm and Fuzzy Logic (진화 연산 알고리즘과 퍼지 논리를 이용한 고속 열처리 공정기의 제어기 설계)

  • Hwang, Min-Woong;Do, Hyun-Min;Choi, Jin-Young
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.8 no.6
    • /
    • pp.37-47
    • /
    • 1998
  • This paper proposes a controller design method using the evolutionary computation algorithm and the fuzzy logic to control the wafer temperature in rapid thermal processing. First, we design the feedforward static controller to provide the control powers of the lamps for the given steady state temperature. Second, the feedforward dynamic controller is designed for the additional control powers to achieve a given transient response. These feedforward controllers are implemented by using the fuzzy logic to act as a global nonlinear controller over a wide range of operating points. The parameters of these controllers are optimized by using the evolutionary computation algorithm so that it can be used when the mathematical model is not available. In addition, the feedback error controller is introduced to compensate the feedforward controllers when there exist disturbances and modeling errors. The gain of feedback error controller is also obtained by the evolutionary computation algorithm. Through simulations, we verify the proposed control system can give a satisfactory performance.

  • PDF

The Distribution of TrkA in the Olfactory Bulb and Basal Nucleus of the Mongolian Gerbil after Birth (출생 후 몽골리안 저빌의 후각망울과 기저핵에서 TrkA의 분포)

  • Hou, Xilin;Park, Il-kwon;Lee, Kyung-youl;Park, Mi-sun;Kim, Sang-keun;Lee, Kang-yi;Lee, Geun-jwa;Kim, Moo-kang
    • Korean Journal of Veterinary Research
    • /
    • v.43 no.3
    • /
    • pp.317-322
    • /
    • 2003
  • TrkA is an essential component of the high affinity NGF receptor necessary to the mediate biological effects of the neurotrophins NGF. Here we report on the expression of TrkA in the olfactory bulb and basal nucleus of Mongolian gerbil brain during the postnatal development. The expressions of TrkA were identified in a immunohistochemical method. Higher levels of TrkA immunoreactivity were detected in septum than that in olfactory bulb and caudate putamen (CPu). But TrkA was not observed before postnatal days (PND6) in olfactory bulb and PND9 in CPu. No TrkA-positive cell was detectable in the olfactory fiber layer. Several regions, such as olfactory bulb and CPu, showed weak labeling. These data show that expression of TrkA is developmentally regulated during postnatal Mongolian gerbil brain development and suggest that high affinity neurotrophinreceptors mediate a transient response to neurotrophins in many regions during the brain ontogeny.

A Study on Excitation System for Synchronous Generator Using Two State Three Phase PWM AC/DC Converter (2단 3상 PWM AC/DC 컨버터를 이용한 동기발전기 여자제어시스템)

  • Lee, Sang-Hun;Lee, Dong-Hee;Ahn, Jin-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.3
    • /
    • pp.96-106
    • /
    • 2007
  • The terminal voltage of a synchronous generator is maintained by the field current control of excitation system. Generally AC/DC converter which is component of AVR(Automatic Voltage Regulator) system for excitation current control is connected to diode rectifier and DC/DC converter system. In the case of diode rectifier system of phase controlled converter as AC/DC converter have low power factor and harmonics of lower order in the line current. In this paper, two stage three phase PWM AC/DC converter is studied to solve these problems. The characteristics of a proposed converter reduces the harmonics and reactive power of the distribution line and has fast dynamic response in transient period using boost converter and current control mode buck converts. The proposed method is verified by the computer simulation and experimental results in prototype generation system.

A Study on Correlation Between Skid Distance and Pre-Braking Speed (활주거리와 제동전 속도간의 상관관계에 관한 연구)

  • Jeong, U-Taek;O, Yeong-Tae;Park, Yeong-Su;Ryu, Tae-Seon
    • Journal of Korean Society of Transportation
    • /
    • v.29 no.3
    • /
    • pp.115-122
    • /
    • 2011
  • This paper investigates the accuracy of the vehicle pre-braking speed estimated based upon measured skidding distance. Driver ordinarily takes sudden braking when urgent situation is developed in the front or when the driver is involved in an unexpected situation, and the driver may be inflicted upon an accident depending on the required stopping distance. Among factors influencing the stopping distance of vehicle such as recognition response time of driver, performance of vehicle's braking device, and state of road surface etc, pre-braking speed is seemingly the most important influencing factor. Currently, in the investigating section of traffic accidents, the state of overspeed is determined by the pre-skidding speed calculated based on the length of skid mark. In order to identify the accurate cause of the accident, it is strongly recommended that estimation of pre-braking speed should be estimated taking into account speed reduction during transient time. In this study, we propose a method for estimating more accurate exact speed information of vehicle at the time of traffic accident. The outcomes from this study potentially help better understanding of the characteristics of vehicle for traffic safety in the future.

Frequency Dependence of Impedance of the Grounding Grid (접지그리드의 접지임피던스의 주파수 의존성)

  • 이복희;이동문;엄주홍;김교운
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.5
    • /
    • pp.22-28
    • /
    • 2003
  • This paper describes the frequency dependence of the grounding impedance. In order to propose the evaluation method of the transient response of powered grounding systems, the grounding impedances were measured with varying the frequency of incoming currents by way of the variable frequency inverter and band pass filter. The magnitude and phase of the grounding impedance were analyzed in the frequency range of 20 [Hz]∼2.1[kHz]. The grounding impedance were increased with increasing the frequency of the test current. The grounding impedance at the frequency of 2[kHz] in the actual 22.9[kV] substation grounding system was approximately 3 times as large as the 60[Hz] grounding impedance. It was found that the frequency dependence of the grounding impedance is mainly subject to the inductive reactance of the grounding conductors. As a result, it is critical to determine the shape and size of grounding grid reducing the resultant inductance in grounding systems for lightning surge protection.