• Title/Summary/Keyword: Transient period

Search Result 438, Processing Time 0.026 seconds

Tribology of Si incorporated Diamond-like Carbon Films

  • Kim, Myoung-Geun;Lee, Kwang-Rveol;Eun, Kwang-Yong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1998.02a
    • /
    • pp.44-44
    • /
    • 1998
  • It was observed that the friction coefficient decreased with increasing Si concentration in the l ilms. Furthermore, the friction behavior became more s때ble even when very small amount of S Si of less than 0.5 at. % was incorporatA:회 By analyzing the composition of the debris f formed, we could show that the low and stabilized friction coefficient is in마nately relatA:었 w with the formation of the Si rich oxide debris. These result supports the mechanism that the h hydrated silica debris is the reason for low friction coefficient in humid environment. Second e evidence of the role of Si rich oxide debris could be found in the triOO-chemical reactions d during initial stage of triho-test. When the Si concen$\sigma$ation was less than 5 at.%, initial t transient period of high friction coefficient was commonly observed. Mter the transient period, m the friction coefficient becomes lower with increasing contact cycles. The initial $\sigma$ansient p peri여 becomes shorter and the starting and maximum friction coefficients in $\sigma$ansient 야,riod d decreased with increasing Si concentration. Composition of the debris on the wear scar s surface was analyzed by Auger spe따'Oscopy at v뼈ous stages in the initial transient period. W We observed that when the friction coefficient increased in earlier stage of the $\sigma$'ansient p period, iron and oxygen was observed in the debris. However, decrease in the 당iction c coefficient in the later stage of the transient period was associated with the formation of s silicon rich oxide debris. This result also supports the friction mechanism of Si-DLC films t that the formation of Si rich oxide debris results in low friction coefficient in ambient a atmosphere. atmosphere.

  • PDF

A Numerical Study on the Thermopneumatic and Flow Characteristics of Diffuser-Nozzle Based Thermopneumatic Micropumps (디퓨져와 노즐을 이용한 열공압형 마이크로 펌프의 열공압 및 유동특성에 관한 수치해석적 연구)

  • Jeong Jin;Kim Chang Nyung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.7
    • /
    • pp.642-648
    • /
    • 2005
  • This study has been conducted to investigate the thermopneumatic and flow characteristics of diffuser/nozzle based thermopneumatic micropumps. In this study, a transient three-dimensional numerical analysis using FSI (Fluid-Structure Interaction) model has been employed to analyze the effects of the interaction between the membrane and two fluids (air and water) in the thermopneumtic micropump. The transient temperature and pressure in the cavity, the transient displacements of the membrane and the net flow rate of the micropump have been closely calculated for the frequency of 1 Hz. It has been found that the difference of the flow rates at the inlet and outlet is larger in the cooling period than in the heating period and that the duty ratio is very important in association with pump performance because the temperature in the cavity ascends drastically in the heating period and descends slowly in the cooling period. This study can be regarded as fundamental understandings for the design and analysis of thermopneumatic micropumps.

Unstable Operation of Francis Pump-Turbine at Runaway: Rigid and Elastic Water Column Oscillation Modes

  • Nicolet, Christophe;Alligne, Sebastien;Kawkabani, Basile;Simond, Jean-Jacques;Avellan, Francois
    • International Journal of Fluid Machinery and Systems
    • /
    • v.2 no.4
    • /
    • pp.324-333
    • /
    • 2009
  • This paper presents a numerical simulation study of the transient behavior of a $2{\times}340MW$ pump-turbine power plant, where the results show an unstable behavior at runaway. First, the modeling of hydraulic components based on equivalent schemes is presented. Then, the 2 pump-turbine test case is presented. The transient behavior of the power plant is simulated for a case of emergency shutdown with servomotor failure on Unit 1. Unstable operation at runaway with a period of 15 seconds is properly simulated using a 1-dimensional approach. The simulation results points out a switch after 200 seconds of the unstable behavior between a period of oscillations initially of 15 seconds to a period of oscillation of 2.16 seconds corresponding to the hydraulic circuit first natural period. The pressure fluctuations related to both the rigid and elastic water column mode are presented for oscillation mode characterization. This phenomenon is described as a switch between a rigid and an elastic water column oscillation mode. The influence of the rotating inertia on the switch phenomenon is investigated through a parametric study.

Improvement of Synchronous Motor Transient Stability by Phase Slipping (상변위에 의한 동기전동기의 과도안정도 개선)

  • Song Yop Hahn
    • 전기의세계
    • /
    • v.21 no.2
    • /
    • pp.20-24
    • /
    • 1972
  • The transient stability of the synchronous motor is generally improved by damper winding or flywheel. However the synchronous motor at full load will be pulled out from normal operation state when the period of power failure exceeds approximately ten cycle per second. This paper studies the method of improving the stability of synchronous motor by equipping the phase slipping switch between the motor and power source. This paper shows the motor does not pull out, which results from the decrease of power angle to about 30 electrical degrees by means of the switch even when the relatively long period of power failure brings the power angle to some 150 electrical degrees.

  • PDF

Self-tuning control with improved transient state (초기과도 상태를 개선한 자기 동조 제어 방식)

  • 김운성;배한경;허경무
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1992.10a
    • /
    • pp.376-381
    • /
    • 1992
  • In this thesis, a self-tuning control method based on Variable Structure System technique for tracking control of Direct-Drive motor is presented. The self-tuning control could not make the tracking error zero in the transient period. This tracking error may be due to disturbances or the error in parameter identification. To overcome this problem, a self-tuning control method based on discrete time VSS technique is presented. The STC based on VSS technique gives good tracking performance of the reference signal in the transient period. The proposed controller is robust to parameter errors and disturbances. The performance of the proposed controller is compared with that of simple STC through digital computer simulation.

  • PDF

Unsteady Performance Analysis of a Simple Shaft Gas Turbine Cycle (단순 가스터빈 사이클 과도 성능해석)

  • Kim, Soo-Yong;Soudarev, B.
    • 연구논문집
    • /
    • s.30
    • /
    • pp.5-13
    • /
    • 2000
  • The computation scheme of simulating gas turbine transient behavior was developed. The basic principles of this scheme and main input data required are described. Calculation results are presented in terms of whole operating regime of the cycle. The influence of main initial parameters such as starting engine power, moment of inertia of the rotor, fuel supplying schedule etc. on performance characteristics of has turbine during transient operation is studied In addition, bleeding air influence on transient behavior was also considered For validation of the developed code, comparison of present calculation with that of measurement data of the experimental data for the range of operating period studied.

  • PDF

Groundwater Flow Analysis Using a Transient Three-dimensional Model in an Upland Area (삼차원(三次元) 비정상(非定常) 지하수모형(地下水模型)에 의한 홍적대지의 지하수(地下水) 유동해석(流動解析))

  • Bae, Sang Keun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.10 no.2
    • /
    • pp.59-65
    • /
    • 1990
  • This study investigates the effects of human impact and precipitation on groundwater flow conditions at a small area in Dejima Upland using a transient three-dimensional simulation. To show the utility of the transient three-dimensional model, the results of the numerical model are compared with those of Theis problem for which analytical solution is available. It appears that over the time period studied, the results of the model agree well with the analytical solution. Simulation is undertaken for a period of 30days starting from May 1st, when irrigation starts. Groundwater flow patterns determined by a numerical model are presented in the form of plotted potential lines and discussed. Results of simulation clearly indicate that the groundwater flow system should be analysed using a transient three-dimensional model, especially for the region which is effected by human impact.

  • PDF

NUMERICAL STUDY OF UNSTEADY HEAT TRANSFER ON MICRO HEATER UNDER HALF-CYCLE SINUSOIDAL HEAT LOAD (마이크로히터에서 반주기 정현곡선의 열부하에 의한 비정상 열전달 연구)

  • Kim, M.J.;Lee, H.J.
    • Journal of computational fluids engineering
    • /
    • v.19 no.4
    • /
    • pp.1-7
    • /
    • 2014
  • A numerical study of transient conjugate heat transfer on micro heater in a micro-channel substrate under a sinusoidal heat load was conducted. It was found that the time constant is not affected by the maximum heating magnitude of the sinusoidal heat load. However, the time constant increases with low duration of the sinusoidal heating period and low Reynolds number. Moreover, there is a threshold where a heater temperature do not reach to time constant at low thermal diffusivity, low flow rate, and low pulse duration of the sinusoidal heating. The time constant should be considered for transient convective heat transfer under transient sinusoidal heat load in a micro heat sink.

Analysis of transient Characteristics of Load Sharing Algorithms In Distributed Systems (분산시스템에서 부하공유 알고리즘의 천이특성 해석)

  • 박세명
    • Journal of the Korea Society for Simulation
    • /
    • v.2 no.1
    • /
    • pp.91-106
    • /
    • 1993
  • Load sharing in distributed systems improves systems performance. Research in the field has been focused on steady state performance for load sharing algorithms. However, transient characteristics of such algorithms may be important in a distributed system in which workload for some node is changing. Simulation is the only means to analyze such characteristics. This paper presents a simulation-based analysis of the transient characteristics of four load sharing algorithms ; forward probing, reverse probing, symmetric probing, and multi-threshold symmetric probing algorithms. Discrete event system models for execution of the algorithms in a distributed system has been developed in a SIMSCRIOT II.5 environment. Simulation results indicate that the MSYM algorithm shows the shortest response time in the transient period.

  • PDF

Numerical Simulation on Startup Transient Performance of a Centrifugal Pump

  • Chen, Gang;Shao, Jie;Wu, Yulin;Liu, Shuhong;Cao, Guangjun
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.03a
    • /
    • pp.751-755
    • /
    • 2008
  • During the rapid startup transient of a centrifugal pump, in order to investigate its transient characteristics, the torque equations are deduced. Based on these equations, numerical simulation is carried out with the Large Eddy Simulation(LES) method and UDFs(User Defined Functions) are applied during the simulation. Comparison between simulation and experiment results of pump heads and rotational speed shows that they are in good agreement, indicating that the dynamic characteristics of this pump can be predicted accurate comparatively through simulation with LES method during its startup process.

  • PDF