• 제목/요약/키워드: Transient effects

검색결과 1,115건 처리시간 0.031초

Neuroprotective Effect of Citri Pericarpium On Transient Global Ischemia in Gerbils

  • Kim Jiae;Jung Hyuk-Sang;Won Ran;Park Ji-Ho;Kang Chul hun;Sohn Nak-Won
    • 동의생리병리학회지
    • /
    • 제16권3호
    • /
    • pp.594-601
    • /
    • 2002
  • The current study was carried out to evaluate neuroprotective effects of Citri Pericarpium after transient global ischemia in gerbils. Male Mongolian gerbils weighing 60-80g were anesthetized with 2% isoflurane mixed with 30% oxygen and 70 % nitrogen. Bilateral common carotid arteries were occluded for 5 minute with microaneurysm dips. On 3 or 7 days after ischemic surgery, the gerbils were sacrificed. The brain were removed, embedded in paraffin and sectioned at 8㎛-thickness. Gerbils that received ischemic insult for 5 min showed extensive neuronal damage in the hippocampal CA1 region, and the number of viable neuronal cell was 51.0±2.5/mm, 32.2% of normal group at 7 days after ischemic surgery. In animals that underwent the extract of Citri Pericarpium treatment, the number of viable neuronal cell were significantly better preserved at 110.58±3.58/mm, 72.0% of normal group than those of ischemic group (P<0.01). In the immunohistochemistry of Bax and Bcl-2, the Citri Pericarpium treated group down-regulated the expression of Bax protein at 72hr after transient global ischemia. In contrast, Bcl-2 protein level was not changed. The appearance in TUNEL assay is similar to the pattern of Bax protein. The water extract of Citri Pericarpium significantly reduced the number of TUNEL-positive CA1 pyramidal neurons at 72hr. The results suggest that Citri Pericarpium has potential neuroprotective effects in the transient global ischemia and the increase in the ratio of Bcl-2 to Bax may contribute to the anti-apoptotic effect of Citri Pericarpium.

Wave propagation in a concrete filled steel tubular column due to transient impact load

  • Ding, Xuanming;Fan, Yuming;Kong, Gangqiang;Zheng, Changjie
    • Steel and Composite Structures
    • /
    • 제17권6호
    • /
    • pp.891-906
    • /
    • 2014
  • This study aims to present a three dimensional finite element model to investigate the wave propagation in a concrete filled steel tubular column (CFSC) due to transient impact load. Both the concrete and steel are regarded as linear elastic material. The impact load is simulated by a semi sinusoidal impulse. Besides the CFSC models, a concrete column (CC) model is established for comparing under the same loading condition. The propagation characteristics of the transient waves in CFSC are analyzed in detail. The results show that at the intial stage of the wave propagation, the velocity waves in CFSC are almost the same as those in CC before they arrive at the steel tube. When the waves reach the column side, the velocity responses of CFSC are different from those of CC and the difference is more and more obvious as the waves travel down along the column shaft. The travel distance of the wave front in CFSC is farther than that in CC at the same time. For different wave speeds in steel and concrete material, the wave front in CFSC presents an arch shape, the apex of which locates at the center of the column. Differently, the wave front in CC presents a plane surface. Three dimensional effects on top of CFSC are obvious, therefore, the peak value and arrival time of incident wave crests have great difference at different locations in the radial direction. High-frequency waves on the waveforms are observed. The time difference between incident and reflected wave peaks decreases significantly with r/R when r/R < 0.6, however, it almost keeps constant when $r/R{\geq}0.6$. The time duration between incident and reflected waves calculated by 3D FEM is approximately equal to that calculated by 1D wave theory when r/R is about 2/3.

압입시험의 천이 크리프 해석 (Transient Creep Analysis in Indentation Tests)

  • 이진행;이형일
    • 대한기계학회논문집A
    • /
    • 제36권1호
    • /
    • pp.81-90
    • /
    • 2012
  • 재료시험기법 중 하나인 압입시험은 크리프 특성 분석에 이용될 수 있다. 그러나 많은 기존 연구들이 정상상태의 크리프 특성만을 이용하고 있기 때문에, 단축시험과 압입시험 사이에는 상당한 차이가 발생한다. 따라서 정확한 크리프 평가를 위해서는 천이 크리프 특성을 고려하여야 한다. 본 연구에서는 Ogbonna 등(14)의 구형 압입자를 이용한 천이 크리프 해석을 확장, 자기 유사성을 갖는 원뿔형 압입자에 적용했다. 천이 크리프 특성을 유한요소해석을 통해 분석하여 정리하였으며, 구형 및 원뿔형 압입시험의 천이 특성을 비교했다. 또한 재료의 탄성변형률, 압입자 형상, 압입접촉면적, 대표 변형률 등 기존 평가법들에서 정량적으로 잘 고려되지 못하고 있는 부분들을 살펴보고 그 해결방안을 제시했다.

$Pr^{3+}$이 도핑된 광섬유증폭기의 최적화 및 과도현상에 관한 연구 (A Study on the Optimization and the Transient Phenomena of the $Pr^{3+}$ doped Fiber Amplifier)

  • 이재명;지명훈;염진용;이영우
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2001년도 춘계종합학술대회
    • /
    • pp.333-336
    • /
    • 2001
  • 본 논문에서는 1.3$\mu\textrm{m}$ 대역에서 증폭특성을 갖는 PDFA의 과도응답 특성을 이론적으로 해석하였다. 수치모델은 밀도반전의 형성과정, 여기파워, 신호파워와 증폭기를 따라 변화하는 신호파워를 포함하고 광섬유 증폭기의 길이에 따른 각 에너지준위의 밀도, 여기파워, 이득의 해서과 시간의 변화에 따른 각 에너지준위의 밀도변화와 이득을 해석하였다. 이러한 수치해석의 결과는 광섬유증폭기의 이득 포화와 복구시간을 예측할 수 있게 해주고, 이득의 포화와 복각시간이 광 펄스의 증폭에 미치는 영향을 예측한 수 있게 한다. 시뮬레이션의 결과, 여기광의 파장 1.017$\mu\textrm{m}$, 파워 0.5W이고 광섬유증폭기의 Pr 이온의 도핑농도가 1000ppm일 경우 광섬유증폭기의 길이 약 5m 에서 이득의 포화가 이루어 졌으며 30dB의 이득을 얻었다. 또한 상준위의 이온밀도는 약 250$\mu\textrm{s}$의 시간이 지난후에 포화됨을 알 수 있었다.

  • PDF

Chrysosplenol C가 분리한 백서 심실 근세포 $Ca^{2+}$ Transient에 미치는 효과 (Effects of Chrysosplenol C on Intracellular $Ca^{2+}$ Transient in Isolated Rat Ventricular Myocytes)

  • 정석한;두 디 두 후옹;트란 반 성;뉘엔 만 콩;김영호;우선희
    • 약학회지
    • /
    • 제55권2호
    • /
    • pp.168-171
    • /
    • 2011
  • Chrysosplenol C [5,6-dihydroxy-2-(4-hydroxy-3-methoxyphenyl)-3,7-dimethoxychromen-4-one] is a flavonoid found in Miliusa balansae and Pterocaulon sphacelatum. We have recently shown that chrysosplenol C has positive inotropic effect in isolated rat ventricular myocytes. In the present study, we explored a possible mechanism for the positive inotropic effect of chrysosplenol C by examining intracellular $Ca^{2+}$ transients during action potentials. The intracellular $Ca^{2+}$ transients were measured by confocal $Ca^{2+}$ imaging in field-stimulated single rat ventricular myocytes. Chrysosplenol C (50 ${\mu}M$) significantly increased the magnitudes (${\Delta}F/F_0$) of $Ca^{2+}$ transients (control, $1.08{\pm}0.05$; chrysosplenol C, $1.25{\pm}0.03$; n=8, P<0.01). Half decay time of the action potential-induced $Ca^{2+}$ transient was not altered by chrysosplenol C (50 ${\mu}M$) (control, $154{\pm}6$ ms; chrysosplenol C, $167{\pm}11$ ms; n=21). The $Ca^{2+}$ content in the sarcoplasmic reticulum (SR), measured as caffeine (10 mM)-induced $Ca^{2+}$ transient, was significantly decreased by chrysosplenol C (50 ${\mu}M$). These results indicate that chrysosplenol C increases $Ca^{2+}$ transients without altering $Ca^{2+}$ removal kinetics in ventricular myocytes, providing a possible mechanism for its positive inotropic effect.

인하도선의 길이가 과도접지임피던스에 미치는 영항 (Effects of the Length of Down Conductors on Transient Ground Impedances)

  • 이복희;이수봉;정동철
    • 조명전기설비학회논문지
    • /
    • 제20권4호
    • /
    • pp.72-77
    • /
    • 2006
  • 본 논문은 인하도선의 설치에 따른 접지시스템의 임펄스전류에 대한 과도임피던스 특성을 다루었다. 임펄스전류를 심매설 봉상 접지전각과 그리드 접지전극에 인가하였을 때 임펄스전류의 상승시간과 인하도선의 길이에 따른 전위상승과 실효임펄스접지임피던스를 측정하고 분석하였다. 과도접지임피던스는 접지전극의 형상과 크기 및 임펄스전류의 파형과 인하도선의 길이에 강하게 의존하며, 인덕턴스가 최소화되도록 인하도선을 설치하는 기법이 과도접지 임피던스의 저감을 위한 중요한 요소이다.

광학적으로 제어된 섬유를 가진 비균일 불안정성의 과도 응답의 특성 (Characteristic of Transient Response in Nonuniform Instability with Optically Controlled Fiber)

  • 판린한;박광채
    • 한국정보전자통신기술학회논문지
    • /
    • 제9권5호
    • /
    • pp.445-450
    • /
    • 2016
  • In this paper we study the effect of chaos in nonuniform instability with optical fiber based IoT networks. The transient response of optically controlled fiber has also described. Nonlinear optical fiber effects especially fiber scattering in networks has emerged as the essential means active optical devices. The paradigm instability in fiber Internet serves as a test for fundamental study of chaos and its suppression and exploitation in practical application in optical communication. This paper attempts to present a survey and some of our research findings on the nature of chaotic effect on Internet based optical communication. The transient response in optical fiber has been evaluated theoretically by calculating the variation of the scattering function. The lines has used under open ended termination containing optically induced region. The scattered optical waves in a fiber used in optic communications are temporally unstable above certain threshold intensity.

과도방사선 검출을 위한 핵폭발 검출기 제작 및 검증 (A Nuclear Event Detectors Fabrication and Verification for Detection of a Transient Radiation)

  • 정상훈;이승민;이남호;김하철;조성익
    • 전기학회논문지
    • /
    • 제62권5호
    • /
    • pp.639-642
    • /
    • 2013
  • In this paper, proposed NED(nuclear event detectors) for detection of a transient radiation. Nuclear event detector was blocked of power temporary for defence of critical damage at a electric device when a induced transient radiation. Conventional NED consist of BJT, resistors and capacitors. The NED supply voltage of 5V and MCM(Multi Chip Module) structures. The proposed NED were designed for low supply voltage using 0.18um CMOS process. The response time of proposed NED was 34.8ns. In addition, pulse radiation experiments using a electron beam accelerator, the output signal has occurred.

터보펌프+가스발생기 연계시험 결과를 이용한 액체로켓엔진 시동 과정에 대한 해석 방법의 개선 (Improvement of the Startup Transient Analysis on the Liquid Rocket Engine Using the TP+GG Coupled Test Result)

  • 박순영;조원국;문윤완
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2011년도 제37회 추계학술대회논문집
    • /
    • pp.821-826
    • /
    • 2011
  • 액체로켓 엔진의 개발을 위한 터보펌프+가스발생기(TP+GG) 연계시험을 수행하였으며, 본 시험결과와 Flowmaster를 이용한 엔진 시동해석 결과를 비교함으로써 시동해석 방법의 검증을 수행하였다. 이로부터 엔진 시동해석에 있어서, 초기 터빈의 압력비를 계산하는 방법을 개선하였으며, 특히 시동 초기의 터빈 출구 온도가 시동 해석의 오차에 미치는 영향을 확인하였다.

  • PDF

가스터빈 엔진 천이 성능 시험에 의한 정상상태 성능 예측

  • 양인영;전용민;김춘택;양수석
    • 항공우주기술
    • /
    • 제2권1호
    • /
    • pp.1-10
    • /
    • 2003
  • 항공기용 가스터빈엔진에 대한 경제적인 시험 기법 개발을 위해 천이상태 성능 시험 결과로부터 정상상태 성능을 예측할 수 있는 방안을 모색했다. 천이상태 성능과 정상상태 성능이 서로 달라지는 현상의 원인을 동역학적 천이 효과, 열적 천이 효과, 공기역학적 천이 효과로 구분하고, 각각을 모델링해서 엔진의 천이상태 성능을 통해 정상상태 성능을 계산하는 보정 인자를 정량화했다. 먼저 천이상태 성능시험 시 나타나는 엔진 입ㆍ출구의 온도 변화가 엔진 성능에 미치는 영향을 보정했고, 그 후 도입된 보정 인자를 사용해 정상상태 성능을 예측했다. 이렇게 예측된 결과와 실제 정상상태 성능시험 결과를 비교한 결과, 연료 소모량의 차이 3.68% 이내로 정상상태 성능을 예측할 수 있었다.

  • PDF