• Title/Summary/Keyword: Transient data acquisition system

Search Result 21, Processing Time 0.027 seconds

H/W Design for Fault Location System on Underground Power Cable System (고장점 탐색 장치를 위한 H/W 설계)

  • Lee, Jae-Duck;Ryoo, Hee-Suk;Jung, Dong-Hak;Choi, Sang-Bong;Nam, Kee-Young;Jeong, Seong-Hwan;Kim, Dae-Kyeong
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.709-711
    • /
    • 2005
  • Developing fault location system for underground power cable which can detect its fault location exactly require very high speed data acquisition and signal processing capability. We are developing fault location system which is different from conventional fault locator. This fault location system monitor underground power cable by using on-line speed current sensor and if there are an accident, it record its transient signal and calculate fault location by analyzing it. Signals which acquired when power cable fault arise, showed transient characteristics and its frequency band is very hish. So, to develop fault location system, we designed special high speed data acquisition and signal processing board. In this thesis, we describe on data acquisition and signal processing H/W design for fault location system on underground power cable.

  • PDF

Development of Conversion Program by EMS Data Acquisition (EMS 실계통 데이터 활용을 위한 자동변환 프로그램 개발)

  • Oh, Sung-Kyun;Shin, Man-Cheol;Kim, Kern-Joong;Choi, Young-Min;Kang, Boo-Il;Han, Hei-Cheon
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.410-411
    • /
    • 2007
  • In this paper describe for development of conversion program by EMS data acquisition. Currently EMS output data has a arbitrary bus number and incorrect bus name. It is need to delvelop converting program for using this data to analysis real power system. Conversion consist of bus number and bus name convert, machine's MBASE, X''d, Machine ID, Area, Zone Code, adding tie-line and remove small genererator that was not consider in transient stability analysis. As result of this work, the efficiency of power system analysis is increase and the result input data is used for many analysis applications.

  • PDF

Application of Transient and Frequency Analysis for Detecting Leakage of a Simple Pipeline (누수탐지를 위한 천이류와 주착수분석 적용 연구)

  • Kim, Hyung-Geun;Kim, Hyun-Soo;Lee, Mi-Hyun;Kim, Sang-Hyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.10
    • /
    • pp.1065-1071
    • /
    • 2005
  • Many techniques of leak detection in pipeline systems have developed based on the propagation wave speeds and wave attenuation. In this paper, the transient analysis methodology is used for calculating the wave speed in the plastic pipe and a frequency analysis methodology is developed for leakage detection in water pipe networks. Data acquisition system for pressurized pipeline system were designed md fabricated to obtain high frequency pressure data. The methodology properly handles the unavoidable uncertainties in measurement and modeling error. Based on information from head pressure test data, it provides leak prediction capability from the transient events with leakage.

A Study on Unsteady Flow measurement using Laser Doppler Velocimeter in Curved Duct (곡관에서 laser유속계를 이용한 비정상유동 계측에 대한 연구)

  • 조병기
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.20 no.4
    • /
    • pp.81-89
    • /
    • 1996
  • In the present study, the unsteady in a square-selctional 180.deg. curved duct are experimentally investigated. The experimental study using air in a square-sectional 180.deg. curved duct is carried out to measure axial velocity distributions with data acquisition and processing system. In this system, Rotating Machinery Resolver(RMR) and PHASE Software are used to obtain the results of unsteady flows. In conclusion, the exact measurement of unsteady flow using LDV system depends upon uniformity of metreials, duct thickness, and scattered particles.

  • PDF

Design and development of enhanced criticality alarm system for nuclear applications

  • Srinivas Reddy, Padi;Kumar, R. Amudhu Ramesh;Mathews, M. Geo;Amarendra, G.
    • Nuclear Engineering and Technology
    • /
    • v.50 no.5
    • /
    • pp.690-697
    • /
    • 2018
  • Criticality alarm systems (CASs) are mandatory in nuclear plants for prompt alarm in the event of any criticality incident. False criticality alarms are not desirable as they create a panic environment for radiation workers. The present article describes the design enhancement of the CAS at each stage and provides maximum availability, preventing false criticality alarms. The failure mode and effect analysis are carried out on each element of a CAS. Based on the analysis, additional hardware circuits are developed for early fault detection. Two different methods are developed, one method for channel loop functionality test and another method for dose alarm test using electronic transient pulse. The design enhancement made for the external systems that are integrated with a CAS includes the power supply, criticality evacuation hooter circuit, radiation data acquisition system along with selection of different soft alarm set points, and centralized electronic test facility. The CAS incorporating all improvements are assembled, installed, tested, and validated along with rigorous surveillance procedures in a nuclear plant for a period of 18,000 h.

Realization of a virtual Instrumentation system for On-Line LIM Performance Monitoring (유도형 리니어모터 성능의 온$\cdot$라인 모니터링을 위한 가상계측시스템 구현)

  • Jang, Seok-Myeong;Lee, Sung-Ho;Chang, Kun-Woo;Jeong, Sang-Sub
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.5
    • /
    • pp.205-213
    • /
    • 2001
  • This paper presents a virtual instrumentation(VI) system for LIMs performance on-line monitoring. The VI is designed using the graphical programming language LabVIEW and is capable of performing on-line measurement functions, including data acquisition, display, and analyses in the time and frequency domains, as well as data archiving. To monitor in real time the steady-state and transient electromagnetic thrust of LIMs, the search coil is used for the determination of the flux linkage components, which is then multiplied by the appropriate current components to yield a signal proportional to the electromagnetic thrust. This paper reports the LIM's dynamics measured by the proposed on-line monitoring system.

  • PDF

A Study of Current Transformer for High Power Testing Facility (대전력 시험설비용 변류기 특성에 관한 연구)

  • Jung, Heung-Soo;La, Dae-Ryeol;Kim, Sun-Koo;Roh, Chang-Il;Kim, Won-Man;Lee, Dong-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.735-737
    • /
    • 2002
  • A current transformer for measuring current in high power testing laboratory is exactly proportional to the current including D.C component due to electrical transient. But, current transformer isn't designed to consider D.C component, therefore when data acquisition system measure that current. the error is increased because of saturation of core. This paper describe the concept of transient factor and how to design the current transformer.

  • PDF

PILLAR: Integral test facility for LBE-cooled passive small modular reactor research and computational code benchmark

  • Shin, Yong-Hoon;Park, Jaeyeong;Hur, Jungho;Jeong, Seongjin;Hwang, Il Soon
    • Nuclear Engineering and Technology
    • /
    • v.53 no.11
    • /
    • pp.3580-3596
    • /
    • 2021
  • An integral test facility, PILLAR, was commissioned, aiming to provide valuable experimental results which can be referenced by system and component designers and used for the performance demonstration of liquid-metal-cooled, passive small modular reactors (SMRs) toward their licensing. The setup was conceptualized by a scaling analysis which allows the vertical arrangements to be conserved from its prototypic reactor, scaled uniformly in the radial direction achieving a flow area reduction of 1/200. Its final design includes several heater rods which simulate the reactor core, and a single heat exchanger representing the steam generators in the prototype. The system behaviors were characterized by its data acquisition system implementing various instruments. In this paper, we present not only a detailed description of the facility components, but also selected experimental results of both steady-state and transient cases. The obtained steady-state test results were utilized for the benchmark of a system code, achieving a capability of accurate simulations with ±3% of maximum deviations. It was followed by qualitative comparisons on the transient test results which indicate that the integral system behaviors in passive LBE-cooled systems are able to be predicted by the code.

Development of the Linear Piston Pump Driven by the Hydraulic Power for the Solid Transferring (고형물 이송을 위한 유압구동 선형 피스톤 펌프의 개발)

  • Kim, Bong-Hwan;Ahn, Kook-Chan;Chung, Sung-Won;Kim, Young-Hoon
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.8 no.3
    • /
    • pp.82-89
    • /
    • 2009
  • The purpose of this study is to investigate the actual field application of the linear piston pump for the solid transferring driven by the hydraulic power unit. In this paper, the numerical analysis and performance evaluating experiments were performed. CFX program has been used to obtain the solutions for the problems of three-dimensional, turbulent water flow in the linear piston pump. The velocity and the pressure distributions are obtained using the turbulent $k-\varepsilon$ model. To evaluate the performance of the linear piston pump, the performance test stand and data acquisition system were manufactured. The numerical predictions agree favorably with experimental results within 7% error. Speed of the piston which is satisfied the flow rate 3,000l/min which considers from basic design became 0.33m/s. This paper could be applied to the design of the linear piston pump for the fish transferring.

  • PDF

Automation of Governor Performance Test System (조속기 시험 시스템의 자동화)

  • Lee, I.Y.;Kim, J.W.;Kang, M.G.
    • Journal of Power System Engineering
    • /
    • v.9 no.4
    • /
    • pp.155-161
    • /
    • 2005
  • Governors control the revolution speed of heat engines such as diesel engines, steam turbines and gas turbines. Precise and prompt tests for the control performances of governors are essential both in governors' manufacturing processes and in governors' maintenance processes. In the conventional governor test systems controlled by analog type electronic controllers, the incorporation of heat engine's dynamics to the test system have been considered very difficult to realize. This study suggests a new governor test system controlled by a digital controller using a personal computer. The application of the digital controller to the test system instead of the analog type electronic controller have brought about the following advancements; (1) heat engine's dynamics could be implemented easily in the test system, (2) automatic test data acquisition both in steady state and in transient state enables us to save test time and to enhance the reliability of the tests.

  • PDF