Measurement-based Estimation of the Composite Load Model Parameters

  • Kim, Byoung-Ho;Kim, Hong-Rae
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.6
    • /
    • pp.845-851
    • /
    • 2012
  • Power system loads have a significant impact on a system. Although it is difficult to precisely describe loads in a mathematical model, accurately modeling them is important for a system analysis. The traditional load modeling method is based on the load components of a bus. Recently, the load modeling method based on measurements from a system has been introduced and developed by researchers. The two major components of a load modeling problem are determining the mathematical model for the target system and estimating the parameters of the determined model. We use the composite load model, which has both static and dynamic load characteristics. The ZIP model and the induction motor model are used for the static and dynamic load models, respectively. In this work, we propose the measurement-based parameter estimation method for the composite load model. The test system and related measurements are obtained using transient security assessment tool(TSAT) simulation program and PSS/E. The parameter estimation is then verified using these measurements. Cases are tested and verified using the sample system and its related measurements.

A Study on Under-Frequency Load Shedding Scheme of Korea Electric Power System using TSAT (TSAT을 이용한 우리나라 계통의 저주파수 부하차단 방식 검토)

  • Lee, Kang-Wan;Bae, Joo-Cheon;Cho, Burm-Sup;Oh, Hwa-Jin
    • Proceedings of the KIEE Conference
    • /
    • /
    • pp.34-37
    • /
    • 2003
  • The frequency of power system will change when the load-generation equilibrium is disturbed. Insufficiency of generation from the imbalance between load and generation decreases the power system frequency. In case of the severe emergency, the under frequency load shedding scheme is applied for the power system defense plan. In this paper, we analyzed the dynamic characteristics of under frequency load shedding using new Transient Security Assessment Tool ; TSAT. We applied the actual UFLS scheme to these studies and considered the possible contingency.

  • PDF

Damping Analysis using IEEEST PSS and PSS2A PSS

  • Lee Sang-Seung;Kang Sang-Hee;Jang Gwang-Soo;Li Shan-Ying;Park Jong-Keun;Moon Seung-Il;Yoon Yong-Tae
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.3
    • /
    • pp.271-278
    • /
    • 2006
  • This paper scrutinized the damping effects of installing the prototype PSSs by a transient analysis for eight buses of faults in the South Korean power system. The PSSs used have the co-PSS blocks for IEEEST model with a single input and the co+power PSS blocks for PSS2A model with dual inputs. The simulation tool was a TSAT(Transient Security Assessment Tool) developed by Powertech Labs Inc. The voltages of the transmission line for simulations were 765kV and 345kV, and the faults for eight cases were sequenced by considering the open state and the close state of the lines. In the simulations, the three-phase line to ground (L-G) fault generated different points for each region. The simulations were compared to the cases of no PSS, partial IEEEST and PSS2A, absolute IEEEST, and absolute PSS2A to show that the power system oscillation can be effectively damped by PSS modules. Simulations were conducted to confirm the effectiveness for the KEPCO (Korea Electric Power Corporation) power system.