• Title/Summary/Keyword: Transient Modelling

Search Result 89, Processing Time 0.021 seconds

Modeling and Analysis of Control Scheme for Voltage Source Inverter Based Grid-connection of Wind Turbine (전압원인버터를 이용한 계통연계형 풍력발전의 출력제어 모의 및 해석)

  • 김슬기;김응상
    • Journal of Energy Engineering
    • /
    • v.12 no.2
    • /
    • pp.154-163
    • /
    • 2003
  • Grid connection essentially requires a wind energy conversion system (WECS) to not only supply adequate power responding to constantly varying wind speed but also provide a specified level of voltage magnitude and frequency that is acceptable in the electric power network. To satisfy such requirements, appropriate control schemes of a wind turbine to be connected to the power grid should be employed. This paper presents an output control strategy of a grid-connected wind power generation, which consists of a fixed-pitch wind turbine, a synchronous generator and a AC-DC-AC component with a voltage source inverter built in, and performs modelling and analysis of the strategy using PSCAD/EMTDC, an electromagnetic transient analysis software. Real power output control of the voltage source inverter is implemented to extract the maximum energy from wind speed inputted through wind blades and reactive power control, to keep the terminal voltage of WECS at a specific level. SPWM switching method is used to reduce the harmonics and maintain 60 ㎐ of the output frequency. The wind turbine performance and output corresponding to wind variation and the terminal load change is simulated and analysed.

Multiscale Modeling and Simulation of Water Gas Shift Reactor (Water Gas Shift Reactor의 Multiscale 모델링 및 모사)

  • Lee, Ukjune;Kim, Kihyun;Oh, Min
    • Korean Chemical Engineering Research
    • /
    • v.45 no.6
    • /
    • pp.582-590
    • /
    • 2007
  • In view of the analysis of the phenomena and the prediction of the performance, mathematical modelling and simulation of a high temperature pilot reactor for water gas shift reaction (WGSR) has been carried out. Multiscale simulation incorporated computational fluid dynamics (CFD) technique, which has the capability to deal with the reactor shape, fluid and energy transport with extensive degree of accuracy, and process modeling technique, which, in turn is responsible for reaction kinetics and mass transport. This research employed multiscale simulation and the results were compared with those from process simulation. From multiscale simulation, the maximum conversion of was predicted approximately 0.85 and the maximum temperature at the reactor was calculated 720 K, resulting from the heat of reaction. Dynamic simulation was also performed for the time transient profile of temperature, conversion, etc. Considering the results, it is concluded that multiscale simulation is a safe and accurate technique to predict reactor behaviors, and consequently will be available for the design of commercial size chemical reactors as well as other commercial unit operations.

Impact of predicted climate change on groundwater resources of small islands : Case study of a small Pacific Island

  • Babu, Roshina;Park, Namsik
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.145-145
    • /
    • 2018
  • Small islands rely heavily on groundwater resources in addition to rainwater as the source of freshwater since surface water bodies are often absent. The groundwater resources are vulnerable to sea level rise, coastal flooding, saltwater intrusion, irregular pattern of precipitation resulting in long droughts and flash floods. Increase in population increases the demand for the limited groundwater resources, thus aggravating the problem. In this study, the effects of climate change on Tongatapu Island, Kingdom of Tonga, a small island in Pacific Ocean, are investigated using a sharp interface transient groundwater flow model. Twenty nine downscaled General Circulation Model(GCM) predictions are input to a water balance model to estimate the groundwater recharge. The temporal variation in recharge is predicted over the period of 2010 to 2099. A set of GCM models are selected to represent the ensemble of 29 models based on cumulative recharge at the end of the century. This set of GCM model predictions are then used to simulate a total of six climate scenarios, three each (2010-2039, 2040-2069, and 2070-2099) under RCP 4.5 and RCP 8.5. The impacts of predicted climate change on groundwater resources is evaluated in terms of freshwater volume changes and saltwater ratios in pumping wells compared to present conditions. Though the cumulative recharge at the end of the century indicates a wetter climate compared to the present conditions the large variability in rainfall pattern results in frequent periods of groundwater drought leading to saltwater intrusion in pumping wells. Thus for sustaining the limited groundwater resources in small islands, implementation of timely assessment and management practices are of utmost importance.

  • PDF

Economic Evaluation of Glass Greenhouse Heating Solar Thermal System Applied with Seasonal Borehole Thermal Energy Storage System (BTES 방식의 계간축열 시스템을 적용한 유리온실의 난방용 태양열시스템의 경제성 평가)

  • Park, Sang-Mi;Seo, Tae-Beom
    • Journal of the Korean Solar Energy Society
    • /
    • v.38 no.5
    • /
    • pp.63-74
    • /
    • 2018
  • The heating performance of a solar thermal seasonal storage system applied to a 1,320 m2 glass greenhouse was analyzed numerically, and the economic feasibility depending upon the number of boreholes was evaluated. For this study, the gardening 16th and 19th zucchini greenhouse of Jeollanam-do agricultural research & extension services was selected. And the heating load of the glass greenhouse selected was 1,147 GJ. BTES(Borehole Thermal Energy Storage) was considered as a seasonal storage, which is relatively economical. The number of boreholes was selected from 25 to 150. The TRNSYS was used to predict and analyze the dynamic performance of the solar thermal system. Numerical simulation was performed by modelling the solar thermal seasonal storage system consisting of flat plate solar collector, BTES system, short-term storage tank, boiler, heat exchanger, pump and controller. As a result of the analysis, when the number of boreholes was from 25 to 50, the thermal efficiency of BTES system and the solar fraction was the highest. When the number of boreholes was from 25 to 50, it was analyzed that the payback period was from 5.2 years to 6.2 years. Therefore it was judged to be the number of boreholes of the proposed system was from 25 to 50, which is the most efficient and economical.

Preliminary numerical study on hydrogen distribution characteristics in the process that flow regime transits from jet to buoyancy plume in time and space

  • Wang, Di;Tong, Lili;Liu, Luguo;Cao, Xuewu;Zou, Zhiqiang;Wu, Lingjun;Jiang, Xiaowei
    • Nuclear Engineering and Technology
    • /
    • v.51 no.6
    • /
    • pp.1514-1524
    • /
    • 2019
  • Hydrogen-steam gas mixture may be injected into containment with flow regime varying both spatially and transiently due to wall effect and pressure difference between primary loop and containment in severe accidents induced by loss of coolant accident. Preliminary CFD analysis is conducted to gain information about the helium flow regime transition process from jet to buoyancy plume for forthcoming experimental study. Physical models of impinging jet and wall condensation are validated using separated effect experimental data, firstly. Then helium transportation is analyzed with the effect of jet momentum, buoyancy and wall cooling discussed. Result shows that helium distribution is totally dominated by impinging jet in the beginning, high concentration appears near gas source and wall where jet momentum is strong. With the jet weakening, stable light gas layer without recirculating eddy is established by buoyancy. Transient reversed helium distribution appears due to natural convection resulted from wall cooling, which delays the stratification. It is necessary to concern about hydrogen accumulation in lower space under the containment external cooling strategy. From the perspective of experiment design, measurement point should be set at the height of connecting pipe and near the wall for stratification stability criterion and impinging jet modelling validation.

Aerodynamic behavior of supertall buildings with three-fold rotational symmetric plan shapes: A case study

  • Rafizadeh, Hamidreza;Alaghmandan, Matin;Tabasi, Saba Fattahi;Banihashemi, Saeed
    • Wind and Structures
    • /
    • v.34 no.5
    • /
    • pp.407-419
    • /
    • 2022
  • Many factors should be considered by architects and designers for designing a tall building. Wind load is one of these important factors that govern the design of tall building structures and can become a serious challenge when buildings tend to be built very tall and slender. On the other hand, through the initial stages of a design process, choosing the design geometry greatly affects the wind-induced forces on a tall building. With this respect, geometric shapes with 3-fold rotational symmetry are one of the applied plan shapes in tall buildings. This study, therefore, aims to investigate the aerodynamic characteristics of 8 different geometrical shapes using Computational Fluid Dynamics (CFD) by measuring the drag and lift forces. A case study approach was conducted in which different building shape models have the same total gross area and the same height of 300 meters. The simulation was an incompressible transient flow that ran 1700 timesteps (85 seconds on the real-time scale). The results show a great difference between wind-induced force performance of buildings with different plan shapes. Generally, it is stated that the shapes with the same area, but with smaller perimeters, are better choices for reducing the drag force on buildings. Applying the lift force, the results show that the buildings with plan shapes that have rounded corners act better in crosswind flow while, those with sharp corners induce larger forces in the same direction. This study delivers more analytical understanding of building shapes and their behavior against the wind force through the parametric modelling.

Simulation of Past 6000-Year Climate by Using the Earth System Model of Intermediate Complexity LOVECLIM (중간복잡도 지구시스템모델 LOVECLIM을 이용한 과거 6천년 기후 변화 모의)

  • Jun, Sang-Yoon
    • Atmosphere
    • /
    • v.29 no.1
    • /
    • pp.87-103
    • /
    • 2019
  • This study introduces the overall characteristics of LOVECLIM version 1.3, the earth system model of intermediate complexity (EMIC), including the installation and operation processes by conducting two kinds of past climate simulation. First climate simulation is the equilibrium experiment during the mid-Holocene (6,000 BP), when orbital parameters were different compared to those at present. The overall accuracy of simulated global atmospheric fields by LOVECLIM is relatively lower than that in Coupled Model Intercomparison Project phase 5 (CMIP5) and Paleoclimate modelling Intercomparison Project phase 3 (PMIP3) simulations. However, surface temperature over the globe, the 800 hPa meridional wind over the mid-latitude coastal region, and the 200 hPa zonal wind from LOVECLIM show similar spatial distribution to those multi-model mean of CMIP5/PMIP3 climate models. Second one is the transient climate experiment from mid-Holocene to present. LOVECLIM well captures the major differences in surface temperature between preindustrial and mid-Holocene simulations by CMIP5/PMIP3 multi-model mean, even though it was performed with short integration time (i.e., about four days in a single CPU environment). In this way, although the earth system model of intermediate complexity has a limit due to its relatively low accuracy, it can be a very useful tool in the specific research area such as paleoclimate.

Experimental assessment of thermal radiation effects on containment atmospheres with varying steam content

  • R. Kapulla;S. Paranjape;U. Doll;E. Kirkby;D. Paladino
    • Nuclear Engineering and Technology
    • /
    • v.54 no.11
    • /
    • pp.4348-4358
    • /
    • 2022
  • The thermal-hydraulics phenomena in a containment during an accident will necessarily include radiative heat transfer (i) within the gas mixture due to the high radiative absorption and emission of steam and (ii) between the gas mixture and the surrounding structures. The analysis of some previous PANDA experiments (PSI, Switzerland) demonstrated the importance of the proper modelling of radiation for the benefit of numerical simulations. These results together with dedicated scoping calculations conducted for the present experiments indicated that the radiative heat transfer is considerable, even for a very low amount of steam (≈2%). The H2P2 series conducted in the large-scale PANDA facility at the Paul-Scherrer-Institut (PSI) in the framework of the OECD/NEA HYMERES-2 project is intended to enhance the understanding of thermal radiation phenomena and to provide a benchmark for corresponding numerical simulations. Thus, the test matrix was tailored around the two opposite extremes: either gas compositions with small steam content such that radiative heat transfer phenomena can be neglected. Or gas mixtures containing larger amounts of steam, so that radiative heat transfer is expected to play a dominant role. The H2P2 series consists of 5 experiments designed to isolate the radiation phenomena from convective and diffusive effects as much as possible. One vessel with a diameter of 4 m and a height of 8 m was preconditioned with different mixtures of air / steam at room and elevated temperatures. This was followed by the build-up of a stable helium stratification at constant pressure in the upper part of the vessel. After that, helium was injected from the top into the vessel which leads to an increase of the vessel pressure and a corresponding elevation-dependent and transient rise of the gas temperature. It is shown that even the addition of small amounts of steam in the initial gas atmosphere considerably impacts the radiative heat transport throughout all phases of the experiments and markedly influences i) the monitored gas peak temperature, ii) the temperature history during the compression and iii) the following relaxation phase after the compression was stopped. These PANDA experiments are the first of its kind conducted in a large scale thermal-hydraulic facility.

A Review of Quantitative Landslide Susceptibility Analysis Methods Using Physically Based Modelling (물리사면모델을 활용한 정량적 산사태 취약성 분석기법 리뷰)

  • Park, Hyuck-Jin;Lee, Jung-Hyun
    • The Journal of Engineering Geology
    • /
    • v.32 no.1
    • /
    • pp.27-40
    • /
    • 2022
  • Every year landslides cause serious casualties and property damages around the world. As the accurate prediction of landslides is important to reduce the fatalities and economic losses, various approaches have been developed to predict them. Prediction methods can be divided into landslide susceptibility analysis, landslide hazard analysis and landslide risk analysis according to the type of the conditioning factors, the predicted level of the landslide dangers, and whether the expected consequence cased by landslides were considered. Landslide susceptibility analyses are mainly based on the available landslide data and consequently, they predict the likelihood of landslide occurrence by considering factors that can induce landslides and analyzing the spatial distribution of these factors. Various qualitative and quantitative analysis techniques have been applied to landslide susceptibility analysis. Recently, quantitative susceptibility analyses have predominantly employed the physically based model due to high predictive capacity. This is because the physically based approaches use physical slope model to analyze slope stability regardless of prior landslide occurrence. This approach can also reproduce the physical processes governing landslide occurrence. This review examines physically based landslide susceptibility analysis approaches.