• Title/Summary/Keyword: Transient Liquid Crystal Method

Search Result 35, Processing Time 0.026 seconds

Heat Transfer Measurement Using a Transient Liquid Crystal Technique and Numerical Anlysis (과도액정기법을 이용한 열전달 측정 및 수치해석)

  • Hong Cheol-Hyun;Lee Ki-Baik;Yang Jang-Sik
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.1
    • /
    • pp.68-77
    • /
    • 2005
  • A transient liquid crystal technique has become one of the most effective ways in measuring the local heat transfer coefficients on the entire surface. The key Point of this technique is to convert the inlet flow temperature into an exponential temperature profile using a mesh heater. In order to verify the validity of this technique. the heat transfer characteristics on the wall surface by a pair of longitudinal vortices is investigated experimently and numerically. A standard ${\kappa}-{\varepsilon}$ is used for the numerical analysis of turbulent flow field. It is found from experiment and numerical analysis that two peak values exist over the whole domain. as the longitudinal vortices move to the farther downstream. these peak values decrease and the dimensionless averaged Nusselt number with the lapse of time is maintained nearly at constant values. The experiment results obtained from the present experiment in terms of the transient liquid crystal technique are in good agreement with the numerical results. Therefore, the transient liquid crystal technique developed for the measurement of heat transfer coefficient is proved to be a valid method.

Detailed Measurement of Flow and Heat Transfer Downstream of Rectanglar Vortex Generators Using a Transient Liquid Crystal Technique (과도 액정 기법을 이용한 와동발생기 하류의 유동장 및 열전달 측정)

  • Hong, Cheol-Hyun;Yang, Jang-Sik;Lee, Ki-Baik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.11
    • /
    • pp.1618-1629
    • /
    • 2003
  • The effects of the interaction between flow field and heat transfer caused by the longitudinal vortices are experimentally investigated using a five hole probe and a transient liquid crystal technique. The test facility consists of a wind tunnel with vortex generators protruding from a bottom surface and a mesh heater. In order to control the strength of the longitudinal vortices, the angle of attack of vortex generators used in the present experiment is 20$^{\circ}$, and the spacing between the vortex generators is 25mm. The height and cord length of the vortex generator is 20mm and 50mm, respectively. Three-component mean velocity measurements are made using a f-hole probe system, and the surface temperature distribution is measured by the hue capturing method using a transient liquid crystal technique. The transient liquid crystal technique in measuring heat transfer has become one of the most effective ways in determining the full surface distributions of heat transfer coefficients. The key point of this technique is to convert the inlet flow temperature into an exponential temperature profile using the mesh heater set up in the wind tunnel. The conclusions obtained in the present experiment are as follows: The two maximum heat transfer values exist over the whole domain, and as the longitudinal vortices move to the farther downstream region, these peak values show the decreasing trends. These trends are also observed in the experimental results of other researchers to have used the uniform heat flux method.

A Study on the Heat Transfer Characteristics of Turbulent Round Jet Impinge on the Inclined Concave Surface Using Transient Liquid Crystal Method (과도액정 기법을 이용한 오목표면 경사각도에 따른 난류 충돌 제트의 열전달 특성에 관한 연구)

  • Lim Kyoung-Bin;Lee Chang-Hee;Lee Sang-Hoon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.7 s.250
    • /
    • pp.656-662
    • /
    • 2006
  • The effects of concave hemispherical surface with inclined angle on the local heat transfer from a turbulent round jet impinging were experimentally investigated using transient liquid crystal method. This method suddenly exposes a preheated wall to an impinging jet and then the video system records the response of liquid crystals for the measurement of the surface temperature. The Reynolds numbers were used 11000, 23000 and 50000, nozzle-to-surface distance ratio from 2 to 10 and the surface angles $\alpha=0^{\circ},\;15^{\circ},\;30^{\circ}\;and\;40^{\circ}$. Correlations of the stagnation point Nusselt number according to Reynolds number, jet-to-surface distance ratio and dimensionless surface angle are investigated. In the stagnation point, in term of $Re^n$, n ranges from 0.43 in case of $2{\leq}L/d\leq6$ to 0.45 in case of $6. The maximum Nusselt number occurs in the direction of upstream. The displacement of the maximum Nusselt number from the stagnation point increases with increasing surface angle or decreasing nozzle-to-surface distance. The maximum displacement is about 0.7 times of the jet nozzle diameter.

Experimental Study on the Measurement Method of Heat Transfer Coefficients Using a Transient Liquid Crystal Technique (과도 액정 기법을 이용한 열전달 계수 측정법에 관한 실험적 연구)

  • 홍철현;정준화;양장식;이기백
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.5
    • /
    • pp.581-588
    • /
    • 2003
  • Heat transfer characteristics of a pair of longitudinal vortices using a transient liquid crystal technique are studied experimentally. In order to control the strength of longitudinal vortices, angle of attack of the vortex generators is $20^{\circ}$and the length of space from the centerline the vortex generations is 25mm apart. The heat transfer measurements using a transfer coefficients. The following conclusions are obtained from the present experiment. When any vortex generators are not set up in wind tunnel test, heat transfer rate is low respectively. However, with the vortex generators of rectangular winglet, the heat transfer on the local surface can be enhanced.

Heat transfer coefficient measurement by a jet impinging on a rib-roughened convex surface (표면조도를 가지는 볼록한 면에 충돌하는 제트에 의한 열전달계수 측정)

  • Jeong, Yeong-Seok;Lee, Dae-Hui;Lee, Jun-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.3
    • /
    • pp.373-385
    • /
    • 1998
  • The local Nusselt numbers have been measured for a round turbulent jet impinging on the convex surface with and without rib. Liquid crystal/transient method was used to determine the Nusselt number distributions along the surface. The temperature on the surface was measured to within .+-.0.25 deg. C accuracy using liquid crystal and a digital color image processing system. The experiments were made for the jet Reynolds number (Re) 23,000, the dimensionless nozzle-to-surface distance (L/d) from 6 to 10, the dimensionless surface curvature (d/D) 0.056, and the various rib types (height(d$_{1}$) from 1 to 2 mm, pitch (p) from 6 to 32 mm). It was found that the average Nusselt numbers on the convex surface with rib are higher than those without rib, mainly due to an increase in the turbulent intensity caused by flow separation, recirculation and reattachment on the wall surface. In addition, we compared the results by the steady-state method using the gold-film Intrex with those by the transient method.

A Comparative Study on the Convective Heat Transfer Measurement Technique based on Liquid Crystal (액정을 이용한 대류 열전달 측정 방법의 비교 연구)

  • 정기호;송기범;고기탁;김귀순
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.6 no.3
    • /
    • pp.37-43
    • /
    • 2002
  • There have been numerous experimental studies for heat transfer measurement technique. This study investigates optical methods for measuring local heat transfer coefficient using thermochromic liquid crystal. Transient and steady methods have been utilized to measure local heat transfer coefficient on a cylinder with a cross flow. The steady method is based on the heat-coating technique and two transient methods adopt by-pass technique and insertion technique, respectively. Both techniques of transient method employ heating technique in which the flow is heated by using the electric heater and cooling technique which cools the preheated cylinder. Experimental results indicate that each methods have nearly similar results. Detailed discussions have been made for its own advantages and disadvantages.

An experimental study on the heat transfer augmentation by using the multiple orifice nozzle (다중 오리피스 노즐을 이용한 충돌분류의 열전달 향상에 관한 실험적 연구)

  • 김예용;정기호;김귀순;서태범
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.5
    • /
    • pp.647-657
    • /
    • 1999
  • An experimental study has been peformed to investigate the heat transfer characteristics of impinging jets with multiple orifice nozzles. Four different shapes of multiple orifice nozzle were tested to improve the heat transfer characteristics of impinging jet. Heat transfer coefficients were obtained by using transient and steady method based on the liquid crystal thermography, and both methods showed very similar results. The effects of multiple orifice nozzles on the heat transfer characteristics of impinging jets were discussed in detail. The results showed that multiple orifice nozzles improved the heat transfer characteristics of impinging jet. Especially, heat transfer coefficients around stagnation region of impinging jets were highly increased.

  • PDF

Heat Transfer Measurements by a Round Impinging Jet on a Rib-Roughened Flat Plate (표면조도를 가진 평판에서 원형충돌제트에 의한 열전달 측정)

  • Lee, Dae-Hee;Kim, Yun-Taek;Chung, Seung-Hun;Chung, Young-Suk
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.87-92
    • /
    • 2000
  • This study is to investigate the heat transfer characteristics the for a round turbulent jet impinging on the flat plate with and without rib. Liquid crystal/transient method was used to determine the Nusselt number distributions along the surface. The temperature on the surface was measured using liquid crystal and a digital color image processing system. The experiments were made fur the jet Reynolds number (Re) 23,000, the dimensionless nozzle-to-surface distance (L/d) from 2 to 10, and the rib type [height ($d_1$) 2mm, pitch (p) from 12 to 36mm]. It was found that for $L/d{\ge}6$ the average Nusselt numbers on the flat plate with rib type C ($p/d_1=16$) are higher than those without rib, mainly due to an increase in the turbulent intensity caused by flow separation, recirculation and reattachment on the wall surface.

  • PDF

A Study on the director distribution of In-Plane Switching liquid crystal cell by finite element method (유한요소법을 이용한 IPS 모드의 액정 분자 거동 해석 연구)

  • Jeong, Ju-Sik;Yun, Sang-Ho;Lee, Cheol-Su;Won, Tae-Yeong
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.39 no.4
    • /
    • pp.10-18
    • /
    • 2002
  • This paper reports a methodology for calculating distribution of the director in an In-plane switching liquid crystal cell by a numerical technique. To calculate distribution of the director, we developed a three dimensional finite element method (FEM) and calculated the distribution of electric potential and electric field in the liquid crystal cell. We have considered the free-energy density composed of electric potential and strain energy in the bulk of liquid crystal cell and calculated the switching property of liquid crystal cell by the Ericksen-Leslie equation and the Laplace equation We generated 1,859 nodes and 8,640 elements for IPS mode cell with 24${\mu}{\textrm}{m}$$\times$12${\mu}{\textrm}{m}$$\times$4.5${\mu}{\textrm}{m}$ and performed transient analysis until 16ms. As a result, horizontal electric field occurred at cell region except liquid crystal region above electrodes and the disclination occured on electrodes.

Heat Transfer Measurement by a Round Jet Impinging on a Rib-Roughened Concave Surface (표면조도를 가지는 오목한 면에 충돌하는 원형제트에 의한 열전달 측정)

  • Lee, Dae Hee;Won, Se Youl;Lee, Joon Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.6
    • /
    • pp.734-743
    • /
    • 1999
  • The local Nusselt numbers have been measured for a round turbulent jet impinging on the concave surface with and without rib. Liquid crystal/transient method was used to determine the Nusselt number distributions along the surface. The temperature on the surface was measured using liquid crystal and a digital color image processing system. The experiments were made for the jet Reynolds number (Re) 23,000, the dimensionless nozzle-to-surface distance (L/d) from 4 to 10, the dimensionless surface curvature (d/D) 0.056, and the rib type (height ($d_1$) 0.2 cm, pitch (p) from 1.2 to 3.2 cm). It was founded that only when $L/d{\geq}6$, the average Nusselt numbers on the concave surface with rib are higher than those without rib, mainly due to an increase in the turbulent intensity caused by the effect of rib attached to the wall surface. It was realized that the rib attached to the concave surface may no longer enhance the heat transfer rate or even lowers it depending on the rib type and flow conditions. In addition, the results by the steady-state method using the gold-film Intrex were in good agreement with those by the transient shroud method.