• Title/Summary/Keyword: Transient Input Power

Search Result 195, Processing Time 0.021 seconds

Transient Performance of a Hybrid Electric Vehicle with Multiple Input DC-DC Converter

  • Nashed, Maged N.F.
    • Journal of Power Electronics
    • /
    • v.3 no.4
    • /
    • pp.230-238
    • /
    • 2003
  • Electric vehicles (EV) demands for greater acceleration, performance and vehicle range in pure electric vehicles plus mandated requirements to further reduce emissions in hybrid electric vehicles (HEV) increase the appeal for combined on-board energy storage systems and generators. And the power electronics plays an important role in providing an interface between fuel cells (FC) and loads. This paper deals with a multiple input DC-DC power converter devoted to combine the power flowing of multi-source on energy systems. The multi-source is composed of (i) FC system as a prime power demands, (ii) super capacitor banks as energy storage devices for high and intense power demands, (iii) superconducting magnetic energy storage system (SMES), (iv) multiple input DC-DC power converter and (v) a three phase inverter-fed permanent magnet synchronous motor as a drive. In this system, It is used super capacitor banks and superconducting magnetic energy replaces from the battery system. The modeling and transient performance simulation is effective for reducing transient influence caused by sudden charge of effective load. The main purpose of power electronic converters is to convert the DC power output from the fuel cell and other to a suitable AC voltage, which can be connected to electric loads directly (PMSM). The fuel cell and other output is connected to the DC-DC converter, which regulates the DC link voltage.

Characteristics of a High Power Factor Boost Converter with Continuous Current Mode Control

  • Kim, Cherl-Jin;Jang, Jun-Young
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.4B no.2
    • /
    • pp.65-72
    • /
    • 2004
  • Switching power supply systems are widely used in many industrial fields. Power factor correction (PFC) circuits have a tendency to be applied in new power supply designs. The input active power factor correction (APFC) circuits can be implemented in either the two-stage approach or the single-stage approach. The two-stage approach can be classified into boost type PFC circuit and dc/dc converter. The power factor correction circuit with a boost converter used as an input power source is studied in this paper. In a boost power factor correction circuit there are two feedback control loops, which are a current feedback loop and a voltage feedback loop. In this paper, the regulation performance of output voltage and compensator to improve the transient response presented at the continuous conduction mode (CCM) of the boost PFC circuit is analyzed. The validity of designed boost PFC circuit is confirmed by MATLAB simulation and experimental results.

Experimental Identification of Input Power to the Plate Using the Transient Structural Intensity Map

  • Oey, Agustinus;Ih, Jeong-Guon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.10a
    • /
    • pp.110-112
    • /
    • 2009
  • Transient acoustic pressure in the near field of an impacted plate carries information that can be utilized for recovering the impact force history. The inverse calculation approach using BEM-based NAH, which is conventionally used for time harmonic excitation, can be applied for reconstructing the transient waves using the principle of Fourier transform and spectral analysis. Then, using the recovered velocity in normal direction of the plate surface, the corresponding structural intensity can be obtained and the identification of input power can be performed. However, several manipulations should be given to overcome numerical artifacts, such as aliasing and erratic oscillation at discontinuity, and to suppress the effect of noise. Experiment using a simply supported plate is presented for demonstration purpose.

  • PDF

Verification of SARAX code system in the reactor core transient calculation based on the simplified EBR-II benchmark

  • Jia, Xiaoqian;Zheng, Youqi;Du, Xianna;Wang, Yongping;Chen, Jianda
    • Nuclear Engineering and Technology
    • /
    • v.54 no.5
    • /
    • pp.1813-1824
    • /
    • 2022
  • This paper shows the verification work of SARAX code system in the reactor core transient calculation based on the simplified EBR-II Benchmark. The SARAX code system is an analysis package developed by Xi'an Jiaotong University and aims at the advanced reactor R&D. In this work, a neutron-photon coupled power calculation model and a spatial-dependent reactivity feedback model were introduced. To verify the models used in SARAX, the EBR-II SHRT-45R test was simplified to an ULOF transient with an input flowrate change curve by fitting from reference. With the neutron-photon coupled power calculation model, SARAX gave close results in both power fraction and peak power prediction to the reference results. The location of the hottest assembly from SARAX and reference are the same and the relative power deviation of the hottest assembly is 2.6%. As for transient analysis, compared with experimental results and other calculated results, SARAX presents coincident results both in trend and absolute value. The minimum value of core net reactivity during the transient agreed well with the reported results, which ranged from -0.3$ to -0.35$. The results verify the models in SARAX, which are correct and able to simulate the in-core transient with reliable accuracy.

Fast Transient Buck Converter Using a Hysteresis PWM Controller

  • Liu, Yong-Xiao;Zhao, Jin-Bin;Qu, Ke-Qing
    • Journal of Power Electronics
    • /
    • v.13 no.6
    • /
    • pp.991-999
    • /
    • 2013
  • In this paper, a fast transient buck converter using hysteresis PWM control is presented. The proposed control method is based on hysteresis control of the capacitor C voltage. This offers a faster transient response to meet the challenges of the power supply requirements for fast dynamic input and load changes. It also provides better stability and solves the compensation problem of the error amplifier in conversional voltage PWM control. Finally, the steady-state and dynamic operation of the proposed control method are analyzed and verified by simulation and experimental results.

Improvement of Naval Combat System UPS under Abnormal Transients (비정상 과도상태에서의 해군 전투체계 UPS 개선)

  • Kim, Sung-Who;Choi, Han-Go
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.19 no.3
    • /
    • pp.97-103
    • /
    • 2018
  • This paper addresses an improved naval combat UPS(Uninterruptable Power Supply) system under abnormal transients. Previously, thermistor and varistor elements were used to cope with transient overvoltage and overcurrent, however the UPS was frequently unavailable because it was vulnerable to abnormal transient voltage generated during system operation. In order to overcome this problem and protect UPS system, this paper proposes an input power cut-off circuit that detects the initial input power and abnormal transient voltage generated during operation, improvement of power control sequence, and a method to prevent malfunction of an inverter and CPU. The UPS system implementing the proposed method was simulated by input power variable test using programmable AC/DC generator, and finally validated its reliability and stability through field tests by mounting on multifunctional console of naval combat system.

The Improvement of Transient State Characteristics with Voltage Type PWM Conbverter Control (전압형 PWM 컨버터 제어에의한 과도상태의 특성 개선)

  • 이상일;이진섭;백형래
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.3
    • /
    • pp.268-274
    • /
    • 1999
  • The problem of power factor and hmmonics are occurred in convelter system which used to SCRs and diodes as p power semiconductor devices. IGBT power device with selh:ommutation type was solved that problem. maintain the l input line current with sinusoidal wave CUlTent of input power source voltage. It was estimated that improvement of t transient state characteristics with feedfolward compensator added in the diode rectifier with single phase voltage type i inverter was used to simulation load. As a results it was verified that the transient state characteristics with voltage t type PWM convelter control was improved.

  • PDF

Design of an Adaptive Fuzzy Controller for Power System Stabilization

  • Park, Young-Hwan;Park, Jang-Hyun;Yoon, Tae-Woong;Park, Gwi-Tae
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1998.06a
    • /
    • pp.432-437
    • /
    • 1998
  • Power systems have uncertain dynamics due to a variety of effects such as lightning, severe storms and equipment failures. The variation of the effective reactance of a transmission line due to a fault is an example of uncertainty in power system dynamics. Hence, a robust controller to cope with these uncertainties is needed. Recently fuzzy controllers have become quite popular for robust control due to its capability of dealing with unstructured uncertainty. Thus in this paper we design an adaptive fuzzy controller using an input-output linearization approach for the transient stabilization and voltage regulation of a power system under a sudden fault. Simulation results show that satisfactory performance is achieved by the proposed controller.

  • PDF

Characteristic of Power Consumption in Agitated Vessel Using Wire Gauge Impeller (금망임펠러를 이용한 교반조에서의 교반소요동력 특성)

  • Kim, Moon-Gab;Lee, Young-Sei
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.14 no.2
    • /
    • pp.73-78
    • /
    • 2011
  • Power consumption for wire gauge impeller in cylindrical agitated vessel was measured over a wide range of Reynolds number from laminar to turbulent flow regions. The power correlation were obtained agitation power input of WM4 at gassing condition in turbulent region, at gassing condition in transient region and at gassing condition in laminar region. Also the compared with effect of impeller diameter and blade width on agitation power input at gassing condition in turbulent region, at gassing condition in transient region and at gassing condition in laminar region.

The Effect of input signals for improving Power System Stabilizer(PSS) efficiency (전력계통 안정화장치(PSS)의 성능향상을 위한 입력신호 영향)

  • Hur, Jin;Kim, Dong-Joon;Kim, Tae-Kyun;Shin, Jeong-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.144-146
    • /
    • 1999
  • This paper provides an analysis of the effect of input signals, such as acceleration power and generator shaft speed for improving Power System Stabilizer(PSS) efficiency. We consider a single machine and infinite bus system which is modeled by PSCAD/EMTDC. We choose an optimum stabilizer gain with respect to eigenvalue analysis and transient stability analysis to each input signal.

  • PDF