• 제목/요약/키워드: Transient Input Power

검색결과 195건 처리시간 0.023초

Transient Performance of a Hybrid Electric Vehicle with Multiple Input DC-DC Converter

  • Nashed, Maged N.F.
    • Journal of Power Electronics
    • /
    • 제3권4호
    • /
    • pp.230-238
    • /
    • 2003
  • Electric vehicles (EV) demands for greater acceleration, performance and vehicle range in pure electric vehicles plus mandated requirements to further reduce emissions in hybrid electric vehicles (HEV) increase the appeal for combined on-board energy storage systems and generators. And the power electronics plays an important role in providing an interface between fuel cells (FC) and loads. This paper deals with a multiple input DC-DC power converter devoted to combine the power flowing of multi-source on energy systems. The multi-source is composed of (i) FC system as a prime power demands, (ii) super capacitor banks as energy storage devices for high and intense power demands, (iii) superconducting magnetic energy storage system (SMES), (iv) multiple input DC-DC power converter and (v) a three phase inverter-fed permanent magnet synchronous motor as a drive. In this system, It is used super capacitor banks and superconducting magnetic energy replaces from the battery system. The modeling and transient performance simulation is effective for reducing transient influence caused by sudden charge of effective load. The main purpose of power electronic converters is to convert the DC power output from the fuel cell and other to a suitable AC voltage, which can be connected to electric loads directly (PMSM). The fuel cell and other output is connected to the DC-DC converter, which regulates the DC link voltage.

Characteristics of a High Power Factor Boost Converter with Continuous Current Mode Control

  • Kim, Cherl-Jin;Jang, Jun-Young
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제4B권2호
    • /
    • pp.65-72
    • /
    • 2004
  • Switching power supply systems are widely used in many industrial fields. Power factor correction (PFC) circuits have a tendency to be applied in new power supply designs. The input active power factor correction (APFC) circuits can be implemented in either the two-stage approach or the single-stage approach. The two-stage approach can be classified into boost type PFC circuit and dc/dc converter. The power factor correction circuit with a boost converter used as an input power source is studied in this paper. In a boost power factor correction circuit there are two feedback control loops, which are a current feedback loop and a voltage feedback loop. In this paper, the regulation performance of output voltage and compensator to improve the transient response presented at the continuous conduction mode (CCM) of the boost PFC circuit is analyzed. The validity of designed boost PFC circuit is confirmed by MATLAB simulation and experimental results.

Experimental Identification of Input Power to the Plate Using the Transient Structural Intensity Map

  • Oey, Agustinus;Ih, Jeong-Guon
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 추계학술대회 논문집
    • /
    • pp.110-112
    • /
    • 2009
  • Transient acoustic pressure in the near field of an impacted plate carries information that can be utilized for recovering the impact force history. The inverse calculation approach using BEM-based NAH, which is conventionally used for time harmonic excitation, can be applied for reconstructing the transient waves using the principle of Fourier transform and spectral analysis. Then, using the recovered velocity in normal direction of the plate surface, the corresponding structural intensity can be obtained and the identification of input power can be performed. However, several manipulations should be given to overcome numerical artifacts, such as aliasing and erratic oscillation at discontinuity, and to suppress the effect of noise. Experiment using a simply supported plate is presented for demonstration purpose.

  • PDF

Verification of SARAX code system in the reactor core transient calculation based on the simplified EBR-II benchmark

  • Jia, Xiaoqian;Zheng, Youqi;Du, Xianna;Wang, Yongping;Chen, Jianda
    • Nuclear Engineering and Technology
    • /
    • 제54권5호
    • /
    • pp.1813-1824
    • /
    • 2022
  • This paper shows the verification work of SARAX code system in the reactor core transient calculation based on the simplified EBR-II Benchmark. The SARAX code system is an analysis package developed by Xi'an Jiaotong University and aims at the advanced reactor R&D. In this work, a neutron-photon coupled power calculation model and a spatial-dependent reactivity feedback model were introduced. To verify the models used in SARAX, the EBR-II SHRT-45R test was simplified to an ULOF transient with an input flowrate change curve by fitting from reference. With the neutron-photon coupled power calculation model, SARAX gave close results in both power fraction and peak power prediction to the reference results. The location of the hottest assembly from SARAX and reference are the same and the relative power deviation of the hottest assembly is 2.6%. As for transient analysis, compared with experimental results and other calculated results, SARAX presents coincident results both in trend and absolute value. The minimum value of core net reactivity during the transient agreed well with the reported results, which ranged from -0.3$ to -0.35$. The results verify the models in SARAX, which are correct and able to simulate the in-core transient with reliable accuracy.

Fast Transient Buck Converter Using a Hysteresis PWM Controller

  • Liu, Yong-Xiao;Zhao, Jin-Bin;Qu, Ke-Qing
    • Journal of Power Electronics
    • /
    • 제13권6호
    • /
    • pp.991-999
    • /
    • 2013
  • In this paper, a fast transient buck converter using hysteresis PWM control is presented. The proposed control method is based on hysteresis control of the capacitor C voltage. This offers a faster transient response to meet the challenges of the power supply requirements for fast dynamic input and load changes. It also provides better stability and solves the compensation problem of the error amplifier in conversional voltage PWM control. Finally, the steady-state and dynamic operation of the proposed control method are analyzed and verified by simulation and experimental results.

비정상 과도상태에서의 해군 전투체계 UPS 개선 (Improvement of Naval Combat System UPS under Abnormal Transients)

  • 김성후;최한고
    • 융합신호처리학회논문지
    • /
    • 제19권3호
    • /
    • pp.97-103
    • /
    • 2018
  • 본 논문에서는 비정상적인 과도상태에서의 개선된 해상 전투체계 UPS(Uninterruptable Power Supply) 시스템을 다룬다. 기존에는 일시적인 과전압 및 과전류에 대응하기 위하여 서미스터와 바리스터 소자를 사용하고 있지만 시스템 운용 중에 발생하는 비정상 과도전압에는 취약하므로 UPS가 비가용 상태로 되는 경우가 빈번히 발생하였다. 이를 극복하고 UPS 시스템을 보호하기 위하여 본 논문에서는 초기 입력전원 및 운용 중에 발생되는 비정상 과도전압을 감지한 입력 전원 차단회로, 전원제어 시퀀스 개선, 그리고 인버터 및 CPU 오동작 방지 방법 등을 제안한다. 제안된 방법으로 UPS 구현된 시스템은 Programmable AC/DC 발생기를 이용하여 입력전원 가변 시험을 통하여 시뮬레이션을 수행하였으며, 최종적으로 해상 전투체계의 다기능콘솔에 장착하여 현장시험을 통하여 신뢰성과 안정성을 검증하였다.

전압형 PWM 컨버터 제어에의한 과도상태의 특성 개선 (The Improvement of Transient State Characteristics with Voltage Type PWM Conbverter Control)

  • 이상일;이진섭;백형래
    • 전력전자학회논문지
    • /
    • 제4권3호
    • /
    • pp.268-274
    • /
    • 1999
  • 일반적으로 컨버터 장치로서 사용되고 있는 전력용 반도체 소자인 SCR이나 diode를 사용할 때 역률과 고조파의 문제를 야기 시킨다. 이러한 문제점을 해결하기 위해 자기소호형 소자인 IGBT등을 사용하여 입력측 선전류를 입력 전원전압과 동상인 정현파 전류로 유지함으로써 역률과 고조파에 대한 문제를 해결 하였다. 본 논문에서는 컨버터 출력측 직류전압 제어기에 부하전류 전향보상기(feedforward compensator)를 부가하여 출력측에 다이오드 정류기가 부가된 단상 전압형 인버터를 부하로 사용하여 보상기 부가에 따른 과도상태특성을 개선하였으며 전압형 PWM 컨버터 제어에 의한 특성을 시뮬레이션 및 실험 결과를 통하여 확인 하였다.

  • PDF

Design of an Adaptive Fuzzy Controller for Power System Stabilization

  • Park, Young-Hwan;Park, Jang-Hyun;Yoon, Tae-Woong;Park, Gwi-Tae
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 1998년도 The Third Asian Fuzzy Systems Symposium
    • /
    • pp.432-437
    • /
    • 1998
  • Power systems have uncertain dynamics due to a variety of effects such as lightning, severe storms and equipment failures. The variation of the effective reactance of a transmission line due to a fault is an example of uncertainty in power system dynamics. Hence, a robust controller to cope with these uncertainties is needed. Recently fuzzy controllers have become quite popular for robust control due to its capability of dealing with unstructured uncertainty. Thus in this paper we design an adaptive fuzzy controller using an input-output linearization approach for the transient stabilization and voltage regulation of a power system under a sudden fault. Simulation results show that satisfactory performance is achieved by the proposed controller.

  • PDF

금망임펠러를 이용한 교반조에서의 교반소요동력 특성 (Characteristic of Power Consumption in Agitated Vessel Using Wire Gauge Impeller)

  • 김문갑;이영세
    • 한국산업융합학회 논문집
    • /
    • 제14권2호
    • /
    • pp.73-78
    • /
    • 2011
  • Power consumption for wire gauge impeller in cylindrical agitated vessel was measured over a wide range of Reynolds number from laminar to turbulent flow regions. The power correlation were obtained agitation power input of WM4 at gassing condition in turbulent region, at gassing condition in transient region and at gassing condition in laminar region. Also the compared with effect of impeller diameter and blade width on agitation power input at gassing condition in turbulent region, at gassing condition in transient region and at gassing condition in laminar region.

전력계통 안정화장치(PSS)의 성능향상을 위한 입력신호 영향 (The Effect of input signals for improving Power System Stabilizer(PSS) efficiency)

  • 허진;김동준;김태균;신정훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.144-146
    • /
    • 1999
  • This paper provides an analysis of the effect of input signals, such as acceleration power and generator shaft speed for improving Power System Stabilizer(PSS) efficiency. We consider a single machine and infinite bus system which is modeled by PSCAD/EMTDC. We choose an optimum stabilizer gain with respect to eigenvalue analysis and transient stability analysis to each input signal.

  • PDF