• Title/Summary/Keyword: Transient Hot-wire Technique

Search Result 6, Processing Time 0.024 seconds

Development of a New Sensor with Divided Multiple Long and Short Wires in Transient Hot-wire Technique (다수의 분할된 긴 열선과 짧은 열선을 갖는 새로운 비정상열선법 센서개발)

  • Lee, Shin-Pyo;Lee, Myung-Hoon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.5
    • /
    • pp.510-517
    • /
    • 2004
  • A fine hot-wire is used both as a heating element and a temperature sensor in transient hot-wire method. The traditional sensor system is unnecessarily big so that it takes large fluid volume to measure the thermal conductivity. To dramatically reduce this fluid volume, a new sensor fabrication and a data processing method are proposed in this article. Contrast to the conventional and most popular two wire sensor, the new sensor system is made up of divided multiple long and short wires. Through validation experiments, it is found that the measured thermal conductivities of the glycerin are exactly same each other between the conventional and proposed new method. Also some technical considerations in arranging the multiple wires are briefly discussed.

Development of a New Sensor and Data Processing Method in Transient Hot-wire Technique for Nanofluid (나노유체의 열전도율 측정을 위한 새로운 비정상열선법 센서설계와 자료처리방법)

  • Lee, Shin-Pyo;Lee, Myung-Hoon;Kim, Min-Tae;Oh, Je-Myung
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.210-215
    • /
    • 2003
  • A fine hot-wire is used both as a heating element and a temperature sensor in transient hot-wire method. The traditional sensor system is unnecessarily big so that it takes large fluid volume to measure the thermal conductivity. To dramatically reduce this fluid volume, a new sensor fabrication and a data processing method are proposed in this article. Contrast to the conventional and most popular two wire sensor, the new sensor system is made up of divided multiple long and short wires. Through validation experiments, it is found that the measured thermal conductivities of the glycerin are exactly same each other between the conventional and proposed new method. Also some technical considerations in arranging the multiple wires are briefly discussed.

  • PDF

Simultaneous Measurments of Thermal Conductivity and Diffusivity of Liquids with a Transient Short-Hot-Method (짧은 세선에 의한 액체의 열전도율과 열확산율의 동시측정법)

  • 정태용;박수천
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.4
    • /
    • pp.219-224
    • /
    • 1997
  • A transient short-hot-wire technique has been presented for simultaneous measurements of the thermal conductivity and diffusivity of fluids under the microgravity condition. Two-dimensional heat conduction equations for concentric cylinders with various radius ration and length-diameter ratio have been solved numerically by taking account of the heat capacity of the inner cylinder. A unique relation between the non-dimensional temperature of inner cylinder and Fourier number is obtained for a wide range of thermal properties of the fluids, because the relation if found to be almost independent of these properties. Then the characteristic could be utilized as a masterplot to evaluate both the thermal conductivity and diffusivity. In principle, this method is proved to have an error within 1% for both of these properties.

  • PDF

Measurement of thermal conductivity of fluid by unsteady hot wire method (非定常 熱線法 에 의한 流體 의 熱傳達率 測定)

  • 고상근;양상식;노승탁
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.8 no.2
    • /
    • pp.154-161
    • /
    • 1984
  • A modified technique of the transient hot wire method to measure the thermal conductivity of fluid has been described in this paper. The thermal conductivity of fluid can be obtained by acquiring wire temperature as a function of time. Multiplication of the inverse slope of the temperature versus logarithm of time by an instrumental constant gives the thermal conductivity. The constant voltage was applied to Wheatstone bridge circuit. The wire temperature can be measured as a function of time precisely with the aid of the data acquisition system composed of a microprocessor and an analog-digital converter. The thermal conductivity of the electrically conducting fluid has been measured with the insulated hot wire coated by electrically non-conducting material. The effect of the coated insulation layer on the thermal conductivity has been examined, in which it is confirmed that the thermal conductivity of electrically conducting liquid can be determined by the transient coated hot wire method. Thermal conductivities of methanol, carbontetrachrolide, Freon-22 and glycerin have been measured at room temperature in the pressure from 0.1MPa to 35.1MPa. The experiment has been performed to compare the data from the bare and the coated wires, and the results are satisfactory.

An Experimental Study of Transient Hot-wire Sensor Module for Measuring Thermal Diffusivity of Nanofluids (나노유체의 열확산율 측정을 위한 비정상열선법 센서모듈 실험)

  • Lee, Shin-Pyo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.2
    • /
    • pp.113-120
    • /
    • 2011
  • A technique for measuring the thermal diffusivity of nanofluids is proposed in this study. In theory, it has been well known that the transient hot-wire method can be used to measure the thermal conductivity and diffusivity of fluids simultaneously. However, when traditional methods were employed, the accuracy of the calculated thermal conductivity was considerably higher than that of diffusivity. The proposed method has two advantages for practical use: it only needs a simple data-conversion process for calculating the diffusivity, and it can skip the tedious calibration process involved in the case of a wire sensor. A validation experiment for the new system has been performed with the basic fluids, and the comparison experiment to compare the change in diffusivity of the base oil and the change in diffusivity of the nano oil has been carried out. It is expected that the present system will provide numerous methods for investigating the variation in the thermal properties other than thermal conductivity.

Effect of Dispersion Technique on Heat Transfer Properties of Transformer Oil with Nanoparticles (변압기 나노절연유의 열전달특성에 미치는 분산기술의 영향)

  • Song, Hyun-Woo;Choi, Cheol;Oh, Je-Myung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.151-152
    • /
    • 2005
  • Both $Al_2O_3$ and AlN nanopowders with diameters from ${\mu}m$ to mm were bead-milled and surface-modified by stabilizing agent. The size of bead-milled nanoparticles compared with the primary powder was effectively decreased and was dependent on milling time and bead size. The results of dispersion stability analysis indicated that chemical bonding between nanoparticles and surfactant is more effective than chemical adsorption to prepare the stable transformer oils containing nanoparticles. In this study, the thermal conductivity of the transformer oils containing nanoparticles was measured by transient hot-wire and laser flash methods.

  • PDF