• 제목/요약/키워드: Transformer type

검색결과 666건 처리시간 0.035초

형태의 변화에 따른 강압용 압전변압기의 유한요소해석 (Finite Element Analysis of Step-down Piezoelectric Transformer with Various Shape)

  • 정현호;박태곤;권오영
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.2
    • /
    • pp.697-700
    • /
    • 2003
  • This paper presents design and analysis of step-down piezoelectric transformer for application to AC-adapters. These transformers are consist of rectangular type and disk type multilayered piezoelectric ceramic plate. This piezoelectric transformer operated in third thickness resonance vibration mode. Finite element methode(FEM) was used for analysing transformer. Vibration mode and electric field of piezoelectric transformer were simulated at resonance frequency. As results, rectangular type transformer's output voltage was higher than the disk type. But disk type transformer's current was lagger than rectangular type. These results are assumed that disk type transformer's mixed vibration mode influence transformer's output characteristics. From these results, we expect that disk type piezoelectric transformer is more adoptable than rectangular plate type piezoelectric transformer for AC adapters.

  • PDF

Yg-Yg 3상 내철형 변압기의 영상분 임피던스 분석 (Zero Sequence Impedance of Yg-Yg Three Phase Core Type Transformer)

  • 조현식;조성우;신창훈;차한주
    • 전기학회논문지
    • /
    • 제65권6호
    • /
    • pp.940-945
    • /
    • 2016
  • In this paper, zero sequence equivalent circuit of Yg-Yg three phase core-type transformer is analyzed. Many problems by iron core structure of the three phase transformer due to asymmetric three phase lines, which includes line disconnection, ground fault, COS OFF, and unbalanced load are reported in the distribution system. To verify a feasibility of zero sequence impedance of Yg-Yg type three phase transformer, fault current generation in the three phase core and shell-type Yg-Yg transformer is compared by PSCAD/EMTDC when single line ground fault is occurred. As a result, shell-type transformer does not affect the flow of fault current, but core-type transformer generate an adverse effect by the zero sequence impedance. The adverse effect is explained by the zero sequence equivalent circuit of core-type transformer and Yg-Yg type three phase core-type transformer supplies a zero sequence fault current to the distribution system.

3kW 멀티스트링 태양광 인버터 설계 및 시뮬레이션 (3kW multi-string photovoltaic inverter design and simulation)

  • 이종인;유병규;유권종;김흥근
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.371-376
    • /
    • 2009
  • The Power Conditioning System is Power Transfer System which make array DC current to the Grid sinusoidal current. These are Low Frequency Transformer Inverter Type, High Frequency Transformer Inverter Type and Transformer-less Type. Low Frequency Transformer Type has a Excellent Isolation property, but doesn't have competitiveness in Size and Cost. Also High Frequency Transformer Type has a good Isolation property but there are many steps in Power transfer Switching. Nowadays, Transformer-less Type inverter change a transformer to DC/DC Converter which is small and cost effective. In this paper shown the DC/DC Converter Transformer-less Type multi-string inverter design and simulation. The Control Algorithm will be introduced and Simulation was accomplished.

  • PDF

평면 동판 권선을 이용한 Flyback 변압기 설계에 관한 연구 (A Study on the Design of Flyback Transformer using Flat copper winding)

  • 김종해
    • 전기전자학회논문지
    • /
    • 제26권3호
    • /
    • pp.445-455
    • /
    • 2022
  • 본 논문에서는 90W급 LED-TV용 DC-DC Flyback 컨버터에 사용되고 있는 소형화 및 권선 자동화에 적합한 사출형 평면 동판 권선 방식의 Flyback 변압기 최적화 설계에 대해서 나타낸다. 또한 본 논문에서는 수동권선방식의 기존 양산 Flyback 변압기에 비해 권선 자동화, Trans 체적 저감 및 전기적 특성 동질성 향상이 가능한 사출형 평면 동판 권선 방식의 Flyback 변압기를 제안한다. 특히 본 논문에서 제안한 사출형 평면 동판 권선 변압기는 권선 자동화를 위하여 수직형 권선 방식으로 구성한다. 본 논문 제안한 사출형 평면 동판 권선 방식의 Flyback 변압기의 1차측과 2차측 권선은 각각 기존 권선, 3중 절연 권선 및 사출형 평면 동판권선을 사용하였다. 최종적으로 Maxwell 2D 및 3D Tool을 이용한 시뮬레이션 결과를 토대로 본 논문에서 제안한 소형화 및 권선 자동화에 적합한 사출형 평면 동판 권선 방식의 Flyback 변압기 최적화 설계를 수행하였다.

2차 권선의 연결방법에 따른 변압기형 초전도 한류기의 특성 (Characteristics of Transformer-Type SFCL according to the Connecting Methods of Secondary Coils)

  • 조용선;박형민;정수복;최효상
    • 전기학회논문지
    • /
    • 제56권12호
    • /
    • pp.2078-2083
    • /
    • 2007
  • We have analyzed operating characteristics of transformer-type superconducting fault current limiter (SFCL) according to the serial or parallel connections of secondary coils with $YBa_2Cu_3O_7$ (YBCO) thin films. The turn ratio between the primary and secondary coils was 63:21. Transformer-type SFCL using a transformer with secondary winding of serial or parallel coils could reduce the unbalanced quench caused by differences of the critical current density between YBCO thin films. We found that transformer-type SFCL having serial or parallel connections induced simultaneous quench between the superconducting units. The limiting current in the transformer-type SFCL with a parallel connection was lowered to 30 % compared to the SFCL with a serial connection. In the meantime, when the currents generated in the superconducting units were similar, the voltage value in the parallel connection was 60 % as low as that in the serial connection. However, the voltage generated in the primary winding was some higher. In conclusion, we found that transformer-type SFCL with parallel connection of secondary coils was more effective in fault current limiting characteristics and in the reduction of the consumption power for superconducting units compared to those of the transformer-type SFCL with serial connection of secondary coils.

3차 권선에 저항을 사용한 변압기형 전류제한기의 동작 특성 (Operating Characteristics of Transformer Type SFCL with Resistor in Tertiary Winding)

  • 최병환;한병성
    • 한국전기전자재료학회논문지
    • /
    • 제21권12호
    • /
    • pp.1111-1117
    • /
    • 2008
  • A transformer type superconducting fault current limiter (SFCL) is one of the fault current limiters which have been proposed to reduce the fault current in the transmission lines. This paper proposes the new circuit configuration of a transformer type SFCL and also investigates the operating characteristics of the transformer type SFCL containig the resistor in the tertiary winding. The proposed SFCL contains the resistor in the tertiary winding. The newly inserted resistor can divert the power which the High-Tc superconducting has to bear. Because the resistor in the tertiary winding relieves the power of the High-Tc superconducting, it is possible that the proposed transformer type SFCL can decrease the more larger fault current than the conventional SFCL with the same High-Tc superconducting. And the cost of the proposed transformer type SFCL can be reduced.

비대칭 3상 선로에서 변압기의 철심구조별 문제점 분석 및 방지대책 (Problem Analysis by Iron Core Structure of the Transformer on Asymmetric three Phase lines and Prevention Measures)

  • 신동열;윤동현;차한주
    • 전기학회논문지
    • /
    • 제61권10호
    • /
    • pp.1536-1541
    • /
    • 2012
  • The study analyzed problems by iron core structure of the three phased transformer on asymmetric three phase lines, which included line disconnections, ground faults, COS OFF, and unbalanced loads on the power distribution system. In particular, by analyzing PT combustion cases within the MOF, the study was able to analyze the combustion cause of the core-type transformer and its effect on the system, conduct simulations and practice demonstrations on the characteristics for each iron core structure of the three phase transformer using PSCAD/EMTDC, and suggest measures to prevent the combustion of the core-type transformer.

3개의 초전도 소자를 갖는 자속구속형 SFCL과 변압기형 SFCL의 특성 비교 (Comparison of Characteristics on the Flux-Lock and the Transformer Type SFCLs with Three Superconducting Units)

  • 이주형;최효상
    • 전기학회논문지P
    • /
    • 제58권1호
    • /
    • pp.79-84
    • /
    • 2009
  • In order to increase the capacity of the superconducting fault current limiter(SFCL), the current and voltage grades of the SFCL must be increased. As a method for the increase of the current and voltage grades of the SFCL, we compared the various characteristics between the flux-lock type SFCL "With three superconducting units connected in series and the transformer type SFCL using the transformer with three secondary circuits. One of three superconducting units had not quenched in the flux-lock type SFCL. Therefore, the unbalanced power burden happened because of the voltage difference generated by unbalanced quenching between the superconducting units. In the meantime, the three superconducting units were all quenched in the transformer type SFCL using the transformer, and the voltage difference generated between the superconducting units was decreased. Therefore, the difference of critical characteristics was complemented by distribution of fault current in accordance with the turn's ratio between primary and secondary windings. The unbalanced power burden of the superconducting units was reduced due to flux-share between the superconducting units in the transformer. In conclusion, the capacity increment of the SFCL using a transformer was easier due to equal distribution of voltages generated by simultaneous quench of the superconducting units. We think that the characteristics is improved more because of the decrease of saturation in the iron core if the secondary winding is increased in the SFCL using the transformer.

변압기 권선을 이용한 자속구속형 초전도 전류제한기의 전류제한 특성 분석 (Analysis on Current Limiting Characteristics of Flux-Lock Type SFCL Using a Transformer Winding)

  • 한태희;임성훈
    • 한국전기전자재료학회논문지
    • /
    • 제24권2호
    • /
    • pp.136-140
    • /
    • 2011
  • The fault current limiting characteristics of the flux-lock type superconducting fault current limiter (SFCL) using a transformer winding were investigated. The suggested flux-lock type SFCL consists of two parallel connected coils on an iron core and the transformer winding connected in series with one of two coils. In this SFCL, the high-TC superconducting (HTSC) element was connected with the secondary side of the transformer. The short-circuit experimental devices to analyze the fault current limiting characteristics of the flux-lock type SFCL using the transformer winding were constructed. Through the short-circuit tests, the flux-lock type SFCL using transformer winding was shown to perform more effective fault current limiting operation compared to the previous flux-lock type SFCL without the transformer winding from the viewpoint of the quench occurrence and the recovery time of the HTSC element.

Analysis on Current Limiting Characteristics of Transformer Type SFCL with Additionally Coupled Circuit

  • Lim, Seung-Taek;Ko, Seok-Cheol;Lim, Sung-Hun
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권2호
    • /
    • pp.533-539
    • /
    • 2018
  • In this paper, the transformer type superconducting fault current limiter (SFCL) with additionally coupled circuit was suggested and its peak fault current limiting characteristics due to the fault condition to affect the fault current were analyzed through the fault current limiting tests. The suggested transformer type SFCL is basically identical to the previous transformer type SFCL except for the additional coupled circuit. The additional coupled circuit, which consists of the magnetically coupled winding to the primary and the secondary windings together with another superconducting element and is connected in parallel with the secondary winding of the transformer type SFCL, is contributed to the peak fault current limiting operation for the larger transient fault current directly after the fault occurrence. To confirm the fault current limiting operation of the suggested SFCL, the fault current limiting tests of the suggested SFCL were performed and its effective peak fault current limiting characteristics were analyzed through the analysis on the electrical equivalent circuit.