• 제목/요약/키워드: Transformer insulating oil

검색결과 113건 처리시간 0.04초

변압기용 가스켓의 오존 열화특성 평가 기술 (Assessment of Ozone Degradation of Gasket Using Transformer)

  • 소진중;심대섭;김범진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.84-86
    • /
    • 2001
  • Acrylonitrile Butadiene Rubber (NBR) has been used as a transformer gasket material because the transformer gaskets should have high resistivity to oil and should not swell and deform when it contact to insulating oils. Serious cracks were observed in the gaskets being used and ozone test was performed on new, specimens. Cracks were also observed on specimens. So we have performed the following tests on the anti-oxidants containing new gaskets according in accordance with KEPCO purchase specifications; ozone resistance, oil resistance, mechanical properties before and after aging.

  • PDF

변압기의 화재확산 방지를 위한 부싱 방화구조체 적용에 관한 연구 (A Study on the Application of Bushings Fire Prevent Structure to Prevent Fire Spread of Transformer)

  • 김도현;조남욱;윤충호;박필용;박근성
    • 한국화재소방학회논문지
    • /
    • 제31권5호
    • /
    • pp.53-62
    • /
    • 2017
  • 경제 및 산업의 원천 에너지원인 전력은 생산과 소비의 지역적 상이함으로 장거리 수송을 필수로 하며, 다중환상망(Multi-loop) 형식의 송배전계통으로 전력을 공급한다. 실질적 사용에 앞서, 변전소내 변압기를 통해 변전과정을 거쳐 각 사용처의 특성을 고려하여 전력공급이 이루어지고 있으며 변압기는 본체, 권선, 절연유, 부싱등의 구조로 결합되어 있다. 변전소에서 발생하는 변압기화재는 가구와 상업시설등에 전기공급을 중단시키고 각종 안전사고를 발생시키는 1차 손실뿐만 아니라 2차적으로 경제 손실을 야기한다. 화재의 원인은 부싱 하부파손에 따른 절연유 유출과 약 1초 이내 발화점에 도달하는 절연유에 의한 화재의 연쇄반응으로 파악된다. 화재피해의 최소화를 위해 연기감지기, 자동소화설비 등이 구축되어있으나 감지기의 동작 및 소화가스 방출지연 등으로 화재진화를 위한 골든타임 확보의 부재가 문제되고 있다. 이에 본 연구는 초기 화재진화에 따른 골든타임 확보의 중요성에 따라 화재확산을 방지하고 절연유 누출을 차단하는 능동적 메커니즘의 필요에 따라 수행되었다. 따라서 화염에 의해 팽창하는 고온형상 유지물질과 기계적 화염차단장치를 적용한 부싱방화구조체를 개발하였다. 실제 부싱 및 프렌지규격을 적용하여 제작된 변압기모형에 부싱방화구조체를 설치하여 실규모 화재실험을 수행하였다. 초기화염으로부터 3초내에 정확한 위치와 높이에 부싱방화구조체가 작동함을 확인하였으며 이는 실제 변압기화재 시 화염 확대를 효과적으로 차단할 수 있을 것으로 사료된다.

배전용 변압기 절연유의 특성 비교 평가 (The Evaluation of Characteristics for Insulating Oil Using the Distribution Transformer)

  • 이병성;박영근;김동명;김필환;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기설비전문위원
    • /
    • pp.97-99
    • /
    • 2004
  • Liquid-immersed pole transformers have utilized an insulation system consisting of natural cellulose-based materials and mineral oil for many years. If the transformers are installed with the abruptly changing load over limitation, its insulation materials are apt to unexpected aging with high temperature. Therefore we have been conscious of developing a transformer that is more thermally stable then conventional types. To measure temperature distribution in the winding of conventional and newly designed transformers, temperature sensors were installed fordirect reading of oil and conductor temperatures at transformers. And we conducted accelerating aging test for these transformers. The measuring data had made use of the design to hybrid insulation system. Also we could find the possibility of this insulation system to apply in pole mounted transformers.

  • PDF

154kV급 가스절연 변압기 개발 (Development of 154kV Gas Insulated Transformer)

  • 우재희;최예림;김경민;이준엽;석복렬
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권12호
    • /
    • pp.532-539
    • /
    • 2005
  • The demand of Gas Insulated Transformer(GIT) using $SF_6$ gas as insulating and cooling medium is being increased dramatically in the underground substation of urban area because it has the advantages of non-flammable and non-explosive, etc. This paper describes the structural features and advantages of the gas insulated transformer compare to an oil immersed transformer, and presents a brief overview of the consideration and technology which apply to $SF_6$ gas insulated transformer.

DSP를 이용한 주상변압기 유전정접 측정기법 연구 (Research of Tan$\delta$ Measurement on Pole Transformers using DSP)

  • 김재철;이보호;김언석;최도혁;이수길
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제11권2호
    • /
    • pp.110-118
    • /
    • 1997
  • 본 논문은 DSP를 이용한 주상변압기 유전정접($tan\;delta$) 활선 측정기법을 제안하였다. 변압기 내부에 콘덴서를 삽입한 후 센서에 전압을 인가하고, 인가된 전압과 콘덴서에 흐르는 전류를 측정하여 본 논문에서 제안한 상호 상관 함수 기법을 이용하여 유전정접을 구하였다. 측정의 성능 향상을 위해 TMS320C31 DSP 보드를 사용하였으며 상호 상관 함수 기법을 사용하였다. 또한 노이즈 영향을 검토하기 위해 컴퓨터 시뮬레이션을 수행하였다. 본 연구의 검증을 위해 본 논문에서 구현한 측정장치와 Schering bridge을 사용하여 비고 실험을 하였다. 실험 결과 주상 변압기 절연진단에 충분히 활용할 수 있음을 알 수 있었다.

  • PDF

가속열화 방법에 의한 주상변압기 절연물의 열열화 특성 평가 (The Evaluation of Thermal Aging Characteristics in Insulating Paper for the Use of the Pole Transformers)

  • 이병성;송일근;이재봉;박동배;한상옥
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.1
    • /
    • pp.100-103
    • /
    • 2003
  • The primary insulation system used in an oil-filled transformer is kraft paper, wood, porcelain and oil. Modern transformers use paper that is chemically treated to improve its tensile strength properties and resistance to aging caused by immersion in oil. But these insulation papers are mainly aged to thermal stress. Over the course of the insulation paper and oil's life it is exposed to high temperatures, oxygen and water. Its interaction with the steel of the tank and core plus the copper and aluminium of the windings will eventually cause the chemical properties of the oil to decay. High temperature have an effect on mechanical strength of cellulous paper using the layer insulation. We made two aging cell in which thermal aging tests of insulation papers and mineral oil are conducted. It is measured dielectric strength, number of acid, moisture, etc. of insulation paper and oil aged in the aging cells.

  • PDF

이온성 및 양성 계면 활성제가 변압기유의 화학적 특성 및 유동대전에 미치는 영향 (Influence of Interface Active substances(Ionic and Amphoteric) on Chemical property and Streaming Electrification of Transformer Oil)

  • 김용운;이덕출
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제10권7호
    • /
    • pp.719-726
    • /
    • 1997
  • This research was conducted to analyze the change of surface tension, viscosity, streaming current and conductivity of transformer oil when it were injected with the interface active substances.(anionic:S-111, cationic:S-121, amphoteric:S-131) The changes properties of the surface tension and viscosity of the oil which were injected with the interface active substances were divided into the changes area and the minimum reduction area. The surface tension and viscosity of the oil which were injected with three different kinds of interface active substances showed remarkable change at the point where the concentration of the substance in anionic, in cationic and in amphoteric were 100[ppm], 10[ppm] and 1[ppm] respectively. The streaming current and conductivity of the same sample oil were also changed at the same densities of the surface tension and viscosity. For this factor, it was possibile for us to interpret the mechanism of the streaming current and conductivity. Therefore the interface active substances of the three kinds were injected into the oil within the limit of optimal volume, prevention effects of electrification were showed more excellence than unmixed insulating oil.

  • PDF

상태감시용 센서를 내장한 배전용 변압기 및 데이터 처리장치 개발 (Development of Distribution Transformer with Condition Monitoring Sensors and Data Processing Unit)

  • 정준홍;유남철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.201_202
    • /
    • 2009
  • This paper presents a design methodology of a distribution transformer with condition monitoring sensors and its data processing unit. The proposed distribution transformer includes various type of condition monitoring sensors such as load current/voltage, temperature and heat aging of insulating oil. The data processing unit is installed at the distribution transformer site. It integrates sensed data and transmits these to a central server system. The proposed distribution transformer and its data processing unit will help an on-line condition monitoring system for distribution transformers.

  • PDF

유동대전된 절연유의 제전방식중 침전극 삽입의 영향 (IV) (The Effect of Needle Electrode in the Static Charge Elimination Methodes for Streaming-Electrification Insulating Oil)

  • 정광현;임헌찬;김용운;황명환;백영채;이덕출
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1202-1204
    • /
    • 1995
  • In this paper, We investigated a charge elimination by using a needle electrode in order to prevent the electrification phenomena of insulating oil flowing by force at the internal transformer. In our experiment, We used Acryle and Teflon as the material of charge reducer and measured each of their streaming current and needle electrode current. As a result of experiment, We can explain that the current of needle electrode increase in proportion to insulation of charge reducer.

  • PDF

CO, $CO_2$ 가스와 Furan 함유량의 분석을 통한 셀룰로오스 절연지의 열 열화특성 (The Thermal Aging Characteristics of Cellulose Paper using Analysis for CO, $CO_2$ Gas and Furan Compounds)

  • 김재훈;한상옥
    • 전기학회논문지P
    • /
    • 제58권4호
    • /
    • pp.499-504
    • /
    • 2009
  • The analysis for furan compound has provided a complementary technique to dissolved gas analysis(DGA) for monitoring transformers when total concentration of CO and $CO_2$ dissolved in oil only has been evaluated the aging of insulating paper. But, the analysis of furanic compounds by high performance liquid chromatography(HPLC) has been important more than DGA recently. Because it has been known that furanic components in transformer oil have come only from the decomposition of insulating paper. Therefore we have manufactured accelerating aging cell which was aged during 60 hours at 100, 150, 180 and $200^{\circ}C$, respectively, for investigating the characteristics of cellulose paper by thermal using analysis for CO, $CO_2$ and furan compound.