• Title/Summary/Keyword: Transformer failure

Search Result 116, Processing Time 0.026 seconds

Diagnosis of Power Transformer Using Modified Self Organizing Map (변형된 SOM을 이용한 유입변압기 열화진단)

  • Lee Jong Pil;Ji Pyeong Shik;Lim Jae Yoon;Kim Sung Soo
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.578-580
    • /
    • 2004
  • Substation facilities have become large and complex in the electric power systems. Development of condition monitoring and diagnosis techniques have been very important to improve the security of substation transformers. This paper presents a method to analyze the cause and the degree of aging of power transformers by Self organizing map(SOM). Dissolved gas data were non-linearly transformed by sigmoid function to make determination of SOM close to that of human. Potential of a failure and the degree of aging of a normal transformer are identified by using the proposed quantitative criterion. Furthermore, transformer aging is monitored by the proposed criterion for a set of transformers. To demonstrate the validity of the proposed method, a case study is performed and its results are presented.

  • PDF

Research on Dielectric Characteristics of Environmental-Friendly Vegetable Insulation Oil for the Pole Transformer (주상변압기 적용을 위한 친환경 식물성절연유의 절연특성 연구)

  • Kwag, Dong-Soon
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.6
    • /
    • pp.81-85
    • /
    • 2010
  • In recent years, environmental concerns have been raised on the use of poorly biodegradable fluids in electrical apparatus in regions where spills from leaks and equipment failure could contaminate the surroundings. The vegetable insulation oils are highly biodegradable, have negligible effect on the environment, human health and ecosystem. Therefore, to assure their safe use in electrical power systems, it may require some processing and modification to improve some of their physical, chemical, thermal and electrical properties. This paper provides a comparative results of the electrical breakdown properties of several vegetable insulation oils and mineral oil to use as dielectric fluid in environmental-friendly pole transformer. Also, the electrical breakdown property of the Nomex and kraft insulation papers in vegetable insulation oil is examined.

Developement of On-Line System for Vibration Signal Analysis (진동신호 분석을 위한 On-Line 시스템 개발)

  • Kim, O.S.;Rim, S.J.;Kim, Y.S.;Lee, Y.G.;Kim, J.C.;Chung, C.S.;Chung, S.J.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07b
    • /
    • pp.616-619
    • /
    • 1995
  • This paper describes developement of on-line system for vibration signal analysis. In the power system, the main reason of transformer fault is due to a large amount of current by a short-circuit and a ground-fault. The electromagnetic force caused by fault-current deforms transformer windings and results in vibration pattern change. Therefore if the continuous on-line vibration monitoring on transformer is performed, an incipient failure can be detected. The developed system is composed of data acquisition devices, user interface program, signal processing program, diagnosis and trend analysis program, self diagnosis program and communication program.

  • PDF

Power Transformer Diagnosis Using a Modified Self Organizing Map

  • Lee J. P.;Ji P. S.;Lim J. Y.;Kim S. S.
    • KIEE International Transactions on Power Engineering
    • /
    • v.5A no.1
    • /
    • pp.40-45
    • /
    • 2005
  • Substation facilities have become extremely large and complex parts of electric power systems. The development of condition monitoring and diagnosis techniques has been a very significant factor in the improvement of substation transformer security. This paper presents a method to analyze the cause, the degree, and the aging process power transformers by the Self Organizing Map (SOM) method. Dissolved gas data were non-linearly transformed by the sigmoid function in SOM that works much the same way as the human decision making process. The potential for failure and the degree of aging of normal transformers are identified by using the proposed quantitative criterion. Furthermore, transformer aging is monitored by the proposed criterion for a set of transformers. To demonstrate the validity of the proposed method, a case study is performed and its results are presented.

Seismic response evaluation of 154 kV transformer porcelain bushing by shaking table tests

  • Chun, Nakhyun;Jeon, Bubgyu;Kim, Sungwan;Chang, Sungjin;Son, Suwon
    • Structural Engineering and Mechanics
    • /
    • v.84 no.2
    • /
    • pp.155-165
    • /
    • 2022
  • The use of electricity and communication between electronic devices is increasing daily, which makes the stability of electrical power supply vital. Since the 1990s, large earthquakes have occurred frequently causing considerable direct damage to electrical power facilities as well as secondary damage, such as difficulty in restoring functions due to the interruption of electric power supply. Therefore, it is very important to establish measures to protect electrical power facilities, such as transformers and switchboards, from earthquakes. In this study, a 154 kV transformer whose service life had expired was installed on the base fabricated by simulating the field conditions and conducting the shaking table tests. The dynamic characteristics and seismic behavior of the 154 kV transformer were analyzed through the resonance frequency search test and seismic simulation test that considers the front, rear, left, and right directions. Since the purpose of this study is to analyze the acceleration amplification in the bushing due to the acceleration amplification, the experimental results were analyzed focusing on the acceleration response and the converted acceleration amplification ratio rather than the failure due to the displacement response of the transformer. The seismic force amplification at the transformer bushing was evaluated by simulating the characteristics of electrical power facilities in South Korea, and compared with the IEC TS 61463 acceleration amplification factor. Finally, the amplification factor at zero period acceleration (ZPA) modified for each return period was summarized. The results of this study can be used as data to define the amplification factor at ZPA of the transformer bushing, simulating the characteristics of electrical power facilities in Korea.

Fault Pattern Analysis and Restoration Prediction Model Construction of Pole Transformer Using Data Mining Technique (데이터마이닝 기법을 이용한 주상변압기 고장유형 분석 및 복구 예측모델 구축에 관한 연구)

  • Hwang, Woo-Hyun;Kim, Ja-Hee;Jang, Wan-Sung;Hong, Jung-Sik;Han, Deuk-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.9
    • /
    • pp.1507-1515
    • /
    • 2008
  • It is essential for electric power companies to have a quick restoration system of the faulted pole transformers which occupy most of transformers to supply stable electricity. However, it takes too much time to restore it when a transformer is out of order suddenly because we now count on operator in investigating causes of failure and making decision of recovery methods. This paper presents the concept of 'Fault pattern analysis and Restoration prediction model using Data mining techniques’, which is based on accumulated fault record of pole transformers in the past. For this, it also suggests external and internal causes of fault which influence the fault pattern of pole transformers. It is expected that we can reduce not only defects in manufacturing procedure by upgrading quality but also the time of predicting fault patterns and recovering when faults occur by using the result.

A Study on the Condition Diagnosis for A Gas-insulated Transformer using Decomposition Gas Analysis (가스분해 분석기법을 활용한 가스 전열 변압기의 상태 진단 연구)

  • Ah-Reum, Kim;Byeong Sub, Kwak;Tae-Hyun, Jun;Hyun-joo, Park
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.8 no.2
    • /
    • pp.119-126
    • /
    • 2022
  • A growing number of gas-insulated transformers in underground power substations in urban areas are approaching 20 years of operation, the time when failures begin to occur. It is thus essential to prevent failure through accurate condition diagnosis of the given facility. Various solid insulation materials exist inside of the transformers, and the generated decomposition gas may differ for each gas-insulated equipment. In this study, a simulation system was designed to analyze the deterioration characteristics of SF6 decomposition gas and insulation materials under the conditions of partial discharge and thermal fault for diagnosis of gas-insulated transformers. Degradation characteristics of the insulation materials was determined using an automatic viscometer and FT-IR. The analysis results showed that the pattern of decomposition gas generation under partial discharge and thermal fault was different. In particular, acetaldehyde was detected under a thermal fault in all types of insulation, but not under partial discharge or an arc condition. In addition, in the case of insulation materials, deterioration of the insulation itself rapidly progressed as the experimental temperature increased. It was confirmed that it was possible to diagnose the internal discharge or thermal fault occurrence of the transformer through the ratio and type of decomposition gas generated in the gas-insulated transformer.

Analysis of the Data Reliability for the Preventive Diagnostic System (예방진단시스템의 데이터 신뢰성 분석)

  • Kweon, Dong-Jin;Chin, Sang-Bum;Kwak, Joo-Sik;Woo, Jung-Wook;Choo, Jin-Boo
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.54 no.2
    • /
    • pp.94-100
    • /
    • 2005
  • Abnormal symptoms on operating conditions of power transformer are monitored by a preventive diagnostic system which prevents the sudden power failure in case of quick progress of abnormal situation. The preventive diagnostic system helps plan the proper maintenance method according to the transformer conditions via accumulated data. KEPCO has adopted the preventive diagnostic system at nine of 345kV substations since 1997. Application techniques of the diagnostic sensors were settled, but diagnostic algorithm and practical use of accumulated data are not yet established. To build up the diagnostic algorithm and effective use of the preventive diagnostic system, the reliability of the data which were accumulated in a server computer is very important. This paper describes the data analysis in the server in order to advance the reliability of the accumulated data of the preventive diagnostic system. The principles and data flows of the diagnostic sensors were analyzed, and the data discrepancy between sensors and server were calibrated.

A Study on the Reliability Evaluation of Power Distribution System with Distributed Generations using Power Supplied Probability (전력공급확률을 이용한 분산형 전원을 고려한 배전계통 신뢰도 평가에 관한 연구)

  • Lee, Hee-Tae;Moon, Jong-Fil;Kim, Jae-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.12
    • /
    • pp.2119-2124
    • /
    • 2010
  • Reliability evaluation of power distribution system is the evaluation for all customers supplied from one power source as main transformer located in substation. However, power sources include not only the main transformer but distributed generations. Typical reliability evaluation has focused on configuration of power system with one source including failure rates of equipment. In this paper, we focus on not only configuration but power sources as distributed generations. New reliability evaluation method using power supplied probability (PSP) is proposed. The proposed evaluation method are proved through case studies.

Inspection On Sensors of Online Preventive diagnostic system Sensors for Power Transformer (변압기 온라인 예방진단 센서의 점검현황)

  • Koo, Kyo-Sun;Kweon, Dong-Jin;Chin, Sang-Bum;Kwak, Joo-Sik;Kang, Yeon-Woog
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.455-460
    • /
    • 2005
  • Preventive diagnostic system for power transformer prevents the sudden power failure through monitoring of abnormal symptoms. KEPCO has adopted the preventive diagnostic system at nine 345kV substations since 1997. Application techniques of the diagnostic sensors were settled, but diagnostic algorithm and practical use of accumulated data are not yet established. To build up the diagnostic algorithm and effective use of the preventive diagnostic system, the reliability of the data accumulated in a server computer is very important. Therefore, this paper describes problem when apply system to substation and solution way to improve reliability of the system

  • PDF