• Title/Summary/Keyword: Transformer design

Search Result 903, Processing Time 0.029 seconds

A Transformer Design and Magnetic Analysis Model for the High-Speed EMU (동력분산형 고속철도용 변압기 설계 및 자계해석 모델)

  • Park, Byoung-Gun;Hyun, Dong-Seok
    • Proceedings of the KSR Conference
    • /
    • 2009.05b
    • /
    • pp.517-524
    • /
    • 2009
  • This paper proposes a magnetic analysis model and design method of transformer for the high-speed EMU. It has a many part of the consideration in design because the transformer in high-speed train has the multiple output. Also the output characteristic, weight, and size of transformer is an important factor. This research proposes a design method of transformer in high-speed EMU. And it is easy to design by using the analysis model in design the transformer through the establishment of the magnetic analysis model.

  • PDF

The Characteristic Analysis and Design of Transformer for LCD Backlight Inverter (LCD 구동 Backlight Inverter용 변압기의 설계 방법과 특성 분석)

  • Kim, Youn-Hyun
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.7
    • /
    • pp.353-361
    • /
    • 2006
  • This paper presents the design scheme of transformer for backlight inverter and discuss the characteristics related to its design, including driving inverter. A few studies have so far been made at design and characteristics analysis of transformer. Therefore, this paper manages the presentation of the advisable design methodology of transformer for backlight inverter supplying CCFL. To verify the proposed method, this paper accomplishes the analysis by FEM coupled with circuit and finally shows that the proposed design method is very useful.

Conceptual Design of Single Phase 10MVA HTS Transformer (단상 10MVA 고온초전도 변압기 개념설계)

  • 석복렬;최명준
    • Progress in Superconductivity and Cryogenics
    • /
    • v.4 no.2
    • /
    • pp.42-46
    • /
    • 2002
  • This research is conducted with the object of Piling up the foundation of design technologies for high temperature superconducting (HTS) power transformer which is thought to be as a powerful power transformer of next generation. In this study, not only the theoretical design of high temperature superconducting (HTS) transformer but also the arrangements of superconducting tape and the cooling method have been conducted. Moreover, electromagnetic analyses using finite element method (FEM) were conducted to confirm the efficiency of the designed transformer.

Analytic Design of a Ferroresonant Transformer for Microwave Heating System (초고주파 가열장치에 사용하는 철공진 변압기의 해석적 설계)

  • 나정웅;김원수
    • 전기의세계
    • /
    • v.28 no.1
    • /
    • pp.53-58
    • /
    • 1979
  • In the microwave heating system, a ferroresonant transformer is used to regulate the magnetron power fluctuation. For the simplification, nonlinear characteristics of the transformer and the magnetron are idealized to be piecewise linear. Dipped peak shape of the magnetron current is explained qualitatively by considering the fundamental and third harmonic frequency components in the circuit. Design equations providing the values of the leakage inductance, turn ratio of the transformer and the capacitance are derived analytically by cosnidering the fundamental frequency component only. The ferroresonant transformer is designed to obtain a required regulation and high input power factor from the derived design equations, and analytical calculations are compared with experimental measurements.

  • PDF

3kW multi-string photovoltaic inverter design and simulation (3kW 멀티스트링 태양광 인버터 설계 및 시뮬레이션)

  • Lee, Jong-In;Yu, Beyng-Gyu;Yu, Gwen-Jong;Kim, Heung-Geun
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.371-376
    • /
    • 2009
  • The Power Conditioning System is Power Transfer System which make array DC current to the Grid sinusoidal current. These are Low Frequency Transformer Inverter Type, High Frequency Transformer Inverter Type and Transformer-less Type. Low Frequency Transformer Type has a Excellent Isolation property, but doesn't have competitiveness in Size and Cost. Also High Frequency Transformer Type has a good Isolation property but there are many steps in Power transfer Switching. Nowadays, Transformer-less Type inverter change a transformer to DC/DC Converter which is small and cost effective. In this paper shown the DC/DC Converter Transformer-less Type multi-string inverter design and simulation. The Control Algorithm will be introduced and Simulation was accomplished.

  • PDF

A Study on the Optimal Design of the Transformer in the PSFB Converter (PSFB 컨버터에서 변압기 최적 설계에 관한 연구)

  • Lee, Il-Oun
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.9
    • /
    • pp.869-876
    • /
    • 2016
  • In the Phase Shifted Full Bridge(: PSFB) converter, there are several design factors including power switches, power switches' driving circuits, transformer and inductor, and rectifier stage, etc. Among them, a key factor influencing an optimal performance of the PSFB converter is the design of transformer. Especially, its effect becomes more important in low voltage and high power applications. In this paper, a study on an optimal design of transformer in the PSFB converter is presented. The design equations for the transformer are derived and analyzed in details, and an example design of the transformer for a 12V, 1200W server power supply application is showed as the result of analysis.

The Temperature Distribution and Thermal Stress Analysis of Mold transformer (주상용 몰드변압기의 온도분포와 열응력 해석)

  • 조한구;이운용;한세원
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.387-390
    • /
    • 2000
  • The life of transformer is significantly dependent on the thermal behavior in windings. To analyse winding temperature rise, many transformer designer have calculated temperature distribution and hot spot point by finite element method(FEM). Recently, numerical analyses of transformer are studied for optimum design, that is electric field analysis, magnetic field, potential vibration, thermal distribution and thermal stress. Therefore design time and design cost are decreased by numerical analysis. In this paper, the temperature distribution and thermal stress analysis of 50kVA pole cast resin transformer for power distribution are investigated by FEM program. The temperature change according to load rates of transformer also have been investigated. We have carried out temperature rise test and test results are compared with simulation data.

  • PDF

Conceptual Design of a Single Phase 33 MVA HTS Transformer with a Tertiary Winding (3차 권선을 고려한 단상 33MVA 고온초전도 변압기의 개념설계)

  • Lee, S.W.;Kim, W.S.;Hahn, S.Y.;Hwang, Y.I.;Choi, K.D.
    • Progress in Superconductivity
    • /
    • v.7 no.2
    • /
    • pp.162-166
    • /
    • 2006
  • We have proposed a 3 phase, 100 MVA, 154 kV class HTS transformer substituting for a 60 MVA conventional transformer. The power transformer of 154 kV class has a tertiary winding besides primary and secondary windings. So the HTS transformer should have the 3rd superconducting winding. In this paper, we designed conceptually the structure of the superconducting windings of a single phase 33 MVA transformer. The electrical characteristics of the HTS transformer such as % impedance and AC loss vary with the arrangement of the windings and gaps between windings. We analyzed the effects of the winding parameters, evaluated the cost of each design, and proposed a suitable HTS transformer model for future power distribution system.

  • PDF

Optimal Design of a Transformer Core Using DEAS (DEAS를 이용한 변압기 코아의 최적설계)

  • Kim, Tae-Gyu;Kim, Jong-Wook
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.6
    • /
    • pp.1055-1063
    • /
    • 2007
  • This paper introduces an optimal design technique for a 250-watt isolation transformer using an optimization method, dynamic encoding algorithm for searches (DEAS). Although the optimal design technique for transformers dates back to 1970s and various optimization methods have been developed so far, literature concerning global optimization for transformer core design is rarely found against its importance. In this paper, core configuration of the isolation transformer whose performance is computed by complex mathematical steps is optimized with DEAS. The optimization result confirms that DEAS can be successfully employed to transformer core design for various performance specifications only by adjusting weight factors in cost function.

A Study of Insulation Design of a Gas Transformer Using Extra Turns.) (여유턴 방식에 의한 가스변압기의 절연 설계에 관한 연구)

  • Heo, Woo-Heng;Ha, Young-Sik;Hong, Jung-Pyo;Kim, Gyu-Tak
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.3
    • /
    • pp.115-121
    • /
    • 2001
  • This paper deals with the electrical insulation design of a gas insulated power transformer based on extra turns method satisfying the impulse test performed in the worst condition. The calculation of electrical strength in insulation structure was done by 2D finite element method. The gas insulated power transformer was manufactured by selecting the optimum arrangement among design results. the validity of the design result is verified by the impulse test of manufactured machine.

  • PDF