• 제목/요약/키워드: Transformer Oils

검색결과 75건 처리시간 0.025초

염분에 따른 변압기유의 AC 철연파괴에 미치는 영향 (The Effect on AC Breakdown of Transformer Oils due to Sodium Chloride)

  • 이용우;신종열;송병기;김석환;홍진웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 추계학술대회 논문집 학회본부
    • /
    • pp.273-275
    • /
    • 1996
  • In order to investigate the electrical properties of naphthanic transformer oils for insulating and cooling, the characteristics for breakdown in temperature range of $20{\sim}100[^{\circ}C]$, that of AC breakdown in 1.0[mm] of gap length were made researches. As a result the characteristics for AC breakdown, it is confirm that the dielectric strength was increased to 6[ppm], 9[ppm] but decreased to 3[ppm].

  • PDF

열 열화에 따른 변압기 절연물의 절연특성 분석 (Analysis of Insulation Characteristics for Transformer Insulating Materials According to Thermal Degradation)

  • 이민구;심재명;임경범;이대동
    • 전기학회논문지
    • /
    • 제65권10호
    • /
    • pp.1688-1693
    • /
    • 2016
  • In this study shall investigate the influence upon the electrical property of transformer oil due to the heat among accelerated heat degradation experiment for a constant hour in the typical insulation oils of mineral base oil, silicon base oil and vegetable oil. In addition, the electric insulation performance of insulation materials in transformer shall be evaluated through the electric property analysis according to the heat degradation of epoxy insulation material, which has been used for electric facilities such as a molded transformer.

전기용량 센서를 이용한 가속 열 열화 변압기의 온라인 상태진단 (On-line Condition Monitoring of Thermal Accelerating Aged Transformer by Capacitive Sensor)

  • 김주한;한상옥;이세현;김한준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 전기설비
    • /
    • pp.82-84
    • /
    • 2005
  • In a transformer, thermal stress is the most influential parameter affecting the aging behavior of insulation system. The aging behavior of insulation system in transformer is determined mainly by the thermal conditions inside the transformer. The thermal stress on the insulation system may occur from operation in a high temperature caused by overloading or local overheating. Thus, this paper investigated the condition monitoring of insulation condition in thermally accelerated aged transformer oils by in-situ sensor. The condition of aged samples was investigated by measurements of relative permittivity i.e. capacitance change by capacitive sensor. Results from the experiments are presented in this paper.

  • PDF

윤활기유의 조성이 전기절연유의 성능 및 특성에 미치는 영향 (The Effect of Base Oil Composition on Electronic Insulating Oil's Performances)

  • 문우식;전정식
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 1998년도 제28회 추계학술대회
    • /
    • pp.181-189
    • /
    • 1998
  • In order to investigate the effect of base oil composition on the electronic insulating oil's performances, an experimental study has been conducted using different oils. Owing to their properties, like lower pour point and gas absorbing, naphthenic base oils are used more often than paraffmic base oils for the electronic insulating oil application. Naphthenic and paraffinic base oils are significantly different in their aromatic hydrocarbon content. In this paper, PXE(para xylyl ethane), LAB(linear alkylbenzene), C13 aromatic hydrocarbon mixture and C17 aromatic hydrocarbon mixture are investigated regarding their influence on insulating oil's performances. According to present study, breakdown voltage decreased with increasing aromatic lydrocarbon content in a deep dewaxed paraffmic base oil. However, any changing in the dissipation factor was not recognizable at small treated level. Furthermore, the volume resistance was not influenced by aromatic hydrocarbon content. The gassing tendency was found as a highly sensible property, changing with treating aromatic hydrocarbons. The higher benzene ring content in the hydrocarbon, the better gassing tendency.

  • PDF

전력분야의 바이오 기반 친환경 전기 절연유 적용에 관한 개발 동향 분석 (Analysis of Development Trends on Bio-based Environmental Transformers Oils in Power Sector)

  • 김재곤;민영제;김목연;곽병섭;박현주
    • Tribology and Lubricants
    • /
    • 제38권2호
    • /
    • pp.41-52
    • /
    • 2022
  • Mineral electrical insulating oil, which is widely used in transformers, exhibits excellent cooling performance and transformer efficiency. However, given that it is composed of petroleum-based components, it is weak in terms of biodegradability. This causes environmental problems in case of leakage and a low flash point, which is a factor that would cause great damage in the event of a fire in a substation. In this context, the use of eco-friendly electric insulating oil composed of bio-based vegetable oil and synthetic ester, which has excellent biodegradability and flame retardancy performance, has recently been expanded to the field of electric power, and various research and development (R&D) studies are in progress. According to different research results, vegetable oil and synthetic ester manufacturing technology, thermal stability, oxidation stability, property change, and quality control, which are characteristics of eco-friendly electrical insulating oils, are major factors affecting the maintenance of insulating oil properties. In addition, power companies have established and operated quality control standards according to the use of eco-friendly electrical insulating oil as they expand the exploitatoin of renewable energy in electricity production. In particular, deterioration and oxidation characteristics were jointly identified in R&D as an important influencing factor according to the content of saturated and unsaturated fatty acids present in vegetable oils and synthetic esters in power transformer applications.

PD Signal Time-Frequency Map and PRPD Pattern Analysis of Nano SiO2 Modified Palm Oil for Transformer Insulation Applications

  • Arvind Shriram, R.K.;Chandrasekar, S.;Karthik, B.
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권2호
    • /
    • pp.902-910
    • /
    • 2018
  • In recent times, development of nanofluid insulation for power transformers is a hot research topic. Many researchers reported the enhancement in dielectric characteristics of nano modified mineral oils. Considering the drawbacks of petroleum based mineral oil, it is necessary to understand the dielectric characteristics of nanofluids developed with natural ester based oils. Palm oil has better insulation characteristics comparable to mineral oil. However very few research reports is available in the area of nanofluids based on palm oil. Partial discharge (PD) is one of the major sources of insulation performance degradation of transformer oil. It is essential to understand the partial discharge(PD) characteristics by collecting huge data base of PD performance of nano modified palm oil which will increase its confidence level for power transformer application. Knowing these facts, in the present work, certain laboratory experiments have been performed on PD characteristics of nano $SiO_2$ modified palm oil at different electrode configurations. Influence of concentration of nano filler material on the PD characteristics is also studied. Partial discharge inception voltage, Phase resolved partial discharge (PRPD) pattern, PD signal time-frequency domain characteristics, PD signal equivalent timelength-bandwidth mapping, Weibull distribution statistical parameters of PRPD pattern, skewness, repetition rate and phase angle variations are evaluated at different test conditions. From the results of the experiments conducted, we came to understand that PD performance of palm oil is considerably enhanced with the addition of $nano-SiO_2$ filler at 0.01%wt and 0.05%wt concentration. Significant reduction in PD inception voltage, repetition rate, Weibull shape parameter and PD magnitude are noticed with addition of $SiO_2$ nanofillers in palm oil. These results will be useful for recommending nano modified palm oil for power transformer applications.

Quantitative Immunoassay for Polychlorinated Biphenyl Compounds in Electrical Insulating Oils

  • Kim In Soo
    • 한국미생물학회:학술대회논문집
    • /
    • 한국미생물학회 2000년도 추계학술발표대회
    • /
    • pp.119-127
    • /
    • 2000
  • The development and performance of a competitive indirect immunoassay for the quantitative measurement of polychlorinated biphenyl compounds in insulating oils is presented. Reagent preparation and the assay characterisation, optimisation and validation steps are described. The dynamic range of the assay for Aroclors 1254 and 1260 in methanol was $50-800 {\mu}g\;ml^{-1}$ with $50\%$ signal inhibition values of 217 and $ 212 {\mu}g\;ml^{-1}$ respectively. Impending legislation in the UK is likely to decree that oils containing $ >50 {\mu}g\;ml^{-1}$ PCB be considered contaminated. Assay sensitivity increased with the degree of PCB chlorination. The assay of structurally related compounds of environmental concern yielded cross-reactivity values of under $0.6\%$. The immunoassay proved reliable for the analysis of transformer oils containing $>70{\mu}g\;ml^{-1}$ PCB, but over-estimated PCB levels in oils containing $<20{\mu}g\;ml^{-1}$ of the analyte with the oils requiring pre-treatment using either solid-phase extraction techniques or washing with KOH-ethanol/sulphuric acid to remove matrix interferents. The analytical performance of the assay was compared against a commercially available semi-quantitative immunoassay kit for PCBs in soil and water.

  • PDF

가속 열 열화에 따른 환경친화형 변압기 절연물의 전기적-기계적 특성 분석 (Analyses on Electrical-Mechanical Characteristics of Environment-friendly Transformer Insulating Material by Accelerated Thermal Aging)

  • 심명섭;안정식;최순호;정중일;이태호;허창수
    • 전기학회논문지
    • /
    • 제59권10호
    • /
    • pp.1832-1838
    • /
    • 2010
  • Aging of transformer insulating material in natural ester insulating oil is compared to that in conventional transformer oil. Aging of insulating paper and insulating oil have been studied by performing accelerated thermal aging test. Sealed aging test vessels containing cooper, laminated core, Kraft paper and insulating oil(natural oil or mineral oil) were aged at $140^{\circ}C$ for 500, 1000, 1500 and 2000 hours. Insulating oils after aging are investigated with total acid number, breakdown voltage and viscosity. Also, degradation of insulating paper after aging is determined using breakdown voltage and mechanical strength. Accelerated aging studies demonstrate a slower aging rate for natural ester insulating oil compared to the rate for conventional mineral oil.

식물성 절연유 변압기의 냉각특성 변화에 따른 최고점온도 특성 해석 (Characteristic Analysis of Hot Spot Temperature according to Cooling Performance Variation of Natural Ester Transformer)

  • 김지호;이향범
    • 전기학회논문지P
    • /
    • 제64권4호
    • /
    • pp.236-240
    • /
    • 2015
  • Natural ester has a higher biodegradability, flash and fire points, and a greater permittivity compared to conventional mineral oils. However, natural ester also has a higher pour point, viscosity, and water content. These characteristics hamper circulation and the electrical properties of oil-filled transformer. Thus, this paper applied electromagnetic-thermal-flow coupled analysis method to predict temperature distribution inside 154kV single phase power transformer using natural ester. It modeled in the actual appearance for the tank and winding of the power transformer to improve the accuracy of analysis and applied heat flow analysis that considered hydromechanics and heat transfer at the same time. It calculated the power loss, the main cause of temperature rise, from winding and core with electromagnetic analysis then used for the heat source for the heat flow analysis. It then compared the reasonability of result of measurement analysis based on the result acquired from temperature rise test using FBG sensor on the power transformer.