• Title/Summary/Keyword: Transformer Oil-paper

Search Result 235, Processing Time 0.023 seconds

Problem considerations and expectations in applying vegetable oil to power transformer (식물성 절연유의 전력용 변압기 적용에 따른 문제점 고찰 및 전망)

  • Park, Hyun-Soo;Kim, Ji-Ho;Lee, Hyang-Beom
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2009.08a
    • /
    • pp.184-186
    • /
    • 2009
  • In past, transformer connection study was concentrated on efficiency improvement and life time broadening. But environmental side began to become important recently. In existing, quick transaction of mineral oil used to insulation oil of transformer is possibility to be difficult and causes environmental pollution in case of was outpoured and there is worry of fire occurrence. Accordingly, nonflammable performance becomes many interest in excellent vegetable oil because ignition point is high than mineral oil and environment friendly material. But, vegetable oil is cooling of transformer and insulation problem of insulating paper for cause of insulation oil special quality. Therefore, in this paper, special quality of vegetable oil that there are being a lot of mineral oil and the latest interest examined about problem and consideration item to be solved to analyzed comparison and applies vegetable oil to transformer for electric power.

  • PDF

Diagnosis for the Transformer depend on Moisture and Furfural Detecting in Oil (절열유중의 수분 및 Furfural 검출을 이용한 유입변압기 상태진단)

  • Choi Gwang-beom;Eo Soo-young;Kweon Dong-jin;Lee Dong-joon
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.12
    • /
    • pp.546-552
    • /
    • 2005
  • In this paper, a present condition with gas-in-oil diagnosis which used to condition analysis for oil insulated transformer is investigated and reason why hydrogen used to basic diagnosis for the transformer is described. This paper gives an overview of background knowledge that should to consider as moisture detecting of oil immersed paper and how could we approach to life expectancy of oil insulated transformer through detecting furfural compound.

Analyses on Electrical-Mechanical Characteristics of Environment-friendly Transformer Insulating Material by Accelerated Thermal Aging (가속 열 열화에 따른 환경친화형 변압기 절연물의 전기적-기계적 특성 분석)

  • Shim, Myeong-Seop;An, Jung-Sik;Choi, Sun-Ho;Jeong, Jung-Il;Lee, Tae-Ho;Huh, Chang-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.10
    • /
    • pp.1832-1838
    • /
    • 2010
  • Aging of transformer insulating material in natural ester insulating oil is compared to that in conventional transformer oil. Aging of insulating paper and insulating oil have been studied by performing accelerated thermal aging test. Sealed aging test vessels containing cooper, laminated core, Kraft paper and insulating oil(natural oil or mineral oil) were aged at $140^{\circ}C$ for 500, 1000, 1500 and 2000 hours. Insulating oils after aging are investigated with total acid number, breakdown voltage and viscosity. Also, degradation of insulating paper after aging is determined using breakdown voltage and mechanical strength. Accelerated aging studies demonstrate a slower aging rate for natural ester insulating oil compared to the rate for conventional mineral oil.

Ageing Diagnostics in Oil Transformer for Large Capacity due to Test methods (시험방법에 의한 대용량 유입변압기의 열화진단)

  • Sim, Yoon-Tae;Kim, Wang-Gon;Hong, Jin-Woong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.96-99
    • /
    • 2003
  • In this paper, ageing diagnostics in the large capacity oil transformer are investigated. Following items are investigated for the ageing diagnostic in transformer oils (leakage current of sensor, power consumption and temperature of transformer oil). All temperature data are gathered from daily report in the substation. The power consumption of transformer are gathered output report of APIS(Airport Power Information System). Especially, data of sensor leakage current are accumulated from the online diagnostic system for transformer oil. The temperature of transformer oils major change factor was ambient temperature and capacity of power load. The leakage current are change by oil temperature. The leakage current ware not more than 2 [nA] in summer,

  • PDF

Effect of the Addition of Benzotriazole on the Streaming Electrification Properties in Transformer Oil

  • Shin, Jong-Yeol;Hong, Jin-Woong
    • Transactions on Electrical and Electronic Materials
    • /
    • v.11 no.6
    • /
    • pp.288-291
    • /
    • 2010
  • Accidents can occur as a result of streaming electrification when transformer oil is used as an insulating oil in large ultra-high voltage transformers. Methods for adding a streaming electrification inhibitor to reduce the streaming electrification has been studied extensively. In this paper, in order to develop a method for reducing streaming electrification effectively, 4 different specimens were prepared by the addition of benzotriazole (BTA) to a virgin specimen with constant stirring. The specimens were examined to determine the appropriate amount of BTA addition that would suppress the streaming electrification most effectively. The results showed that the streaming electrification characteristics of the specimen in the streaming transformer oil were best when the amount of BTA addition was about 10 ppm. The streaming electrification current was reduced by adding 30 ppm BTA until the temperature reached $65^{\circ}C$. The polarity of the streaming electrification current was negative when the temperature exceeded $65^{\circ}C$. Therefore, the streaming electrification current, which can be a cause of transformer accidents, can be suppressed in large ultra high voltage transformer oil. This paper reports on the optimal amount of BTA addition and the best conditions for controlling the streaming velocity of transformer oil.

Transformer diagnosis using characteristics of corona in Oil (변압기의 고장검출을 위한 유중 코로나 특성 연구)

  • 권태원;곽희로;김재철;김응상;박민규
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1989.10a
    • /
    • pp.65-70
    • /
    • 1989
  • This paper presents resarch results on the use of a corona detector and a pulse counter in order to diagnose for oil transformers. Using these experimental apparatus, tests were carried out on a typical transformer oil containing different carbonized paper and various moisture contents to measure the picocoulomb val-ues and pulse count. Through the result of this study it was found that the picocoulomb values and pulse count of corona were depended on the getting stained in transformer oil. The amplitude of the partial discharge amount and the number of pulse were decreased up to 70 [。c] and then was increased as the oil temperature goes up. It was concluded that the determinati-on level for diagnosis of oil transform-er was taken into account the temperatu-er of transformer oil, The use of pulse counter method, which have been taken the same property of voltage and temperature variation for the corona measurement mothod, considera-bly increase insulator avilability.

  • PDF

A Study on the integrity assessment of the high voltage transformer with Dissolved Gas Analysis (특고압 변압기 건전성 평가에 관한 연구)

  • Lee, Il-Moo;You, Sang-Bong;Joung, Hea-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1463-1464
    • /
    • 2015
  • This paper describes for the diagnosis insulating oil for transformers integrity assessment. The high-capacity oil transformer has several insulators are entered for the purpose of insulation, such as insulating oil, insulating paper and press board. Irradiated with a gas component dissolved in the insulating oil can analyze the status of the transformer, and can prevent a sudden accident in advance.

  • PDF

A Study on Corona Inception Voltage and Dielectric Characteristics of Thermally Aged Mineral and Vegetable Insulation Oil in Medium Voltage Power Transformer (식물유 및 광유를 사용한 배전변압기의 열열화에 따른 절연유의 코로나 개시전압 및 전기적 특성에 대한 연구)

  • Jeong, Jung-Il;Huh, Chang-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.12
    • /
    • pp.1745-1750
    • /
    • 2017
  • Starting from the distribution transformer, the insulation oil for the oil immersed power transformer is being used to convert the vegetable oil from the existing mineral oil. Vegetable oil is better in temperature characteristics and insulation performance, is not toxic, and has better biodegradable characteristic than that of mineral oil. In order to investigate the corona inception voltage and dieclectic charateristics of the two insulating oils, three oil immersed transformers using mineral oil and vegetable oil were made and thermal cyclic aged. In this paper, the changes in the corona discharge inception voltage, chemical and electrical properties of the two sampled insulating oils from the transformers had been studied.

The Neural-Fuzzy Control of a Transformer Cooling System

  • Lee, Jong-Yong;Lee, Chul
    • International Journal of Advanced Culture Technology
    • /
    • v.4 no.2
    • /
    • pp.47-56
    • /
    • 2016
  • In transformer cooling systems, oil temperature is controlled through the use of a blower and oil pump. For this paper, set-point algorithms, a reset algorithm and control algorithms of the cooling system were developed by neural networks and fuzzy logics. The oil inlet temperature was set by a $2{\times}2{\times}1$ neural network, and the oil temperature difference was set by a $2{\times}3{\times}1$ neural network. Inputs used for these neural networks were the transformer operating ratio and the air inlet temperature. The inlet set temperature was reset by a fuzzy logic based on the transformer operating ratio and the oil outlet temperature. A blower was used to control the inlet oil temperature while the oil pump was used to control the oil temperature difference by fuzzy logics. In order to analysis the performance of these algorithms, the initial start-up test and the step change test were performed by using the dynamic model of a transformer cooling system. Test results showed that algorithms developed for this study were effective in controlling the oil temperature of a transformer cooling system.

A Study on the Health Evaluation Method of Oil-immersed Transformer through Analysis of Insulating Oil (활선중 절연유 분석을 통한 유입변압기 건전성 평가 방법에 관한 연구)

  • Youn-Jin Shin;Jae-Yong Lim
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.6
    • /
    • pp.1-8
    • /
    • 2023
  • The health state of the oil transformer is evaluated by the age of use and the state of internal defects. Mineral Oil, used as an insulator for oil transformers, creates specific gases and compounds through chemical reactions caused by heat, moisture, and partial discharge inside the transformer. It is possible to determine the aging and defect of the transformer through these gases and compounds. So, it is an important indicator to evaluate the health of a transformer. In this study, factors for assessing the health of transformers were hierarchically categorized, and key factors for each hierarchy were selected for design weighting. These weights were determined through surveys conducted with experts in the fields of transformer design, operation, and quality. For the health of a transformer, defect-related factors are approximately three times more important than factors related to aging. Additionally, defect-related factors showed a higher weighting for gases generated at high temperatures. Furthermore, Furan was determined to have a high weight, directly associated with insulating paper aging. Based on these findings, a health index was proposed, and a comparative analysis was conducted by categorizing 40 operational transformers into normal and comparison groups to evaluate and validate it.