• Title/Summary/Keyword: Transformer Noise

Search Result 204, Processing Time 0.028 seconds

HFPD Characteristic Analysis of Simulated Transformer According To Applied Voltage (인가전압에 따른 모의변압기의 HFPD 특성분석)

  • Kim, Duck-Keun;Im, Young-Sham;Lim, Jang-Seob;Moon, Chae-Joo;Lee, Jin
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1957-1959
    • /
    • 2000
  • The PD measurement method is very useful to detect insulation degradation. Recently, the HFPD(High Frequency Partial Discharge) measurement testing is widely used in partial discharge measurement of HV machines because HFPD measurement testing receives less influence of external noise and has a merit of good sensitivity. Therefore it is very useful method compare to previous conventional PD testing method and effective diagnosis method in power transformer that requires in-service diagnosis. But partial discharges have very complex characteristics of discharge pattern so it is required continuous research to development of precise analysis method. In this study, simulated transformer is manufactured and HFPD occurred from simulated transformer is measured with broad band antenna and active-line RF measurement system in real time, the degradation grade of transformer is analyzed through produced patterns in simulated transformer according to applied voltages. Also the PD pattern which was measured with EMC analyzer and RF measurement system is compared.

  • PDF

Spectrum Analysis of VHF/UHF PD in Simulated Transformer (모의 변압기의 VHF/UHF PD 스펙트럼 분석)

  • Kim, Duck-Keun;Kim, Jong-Seo;Lim, Yong-Bae;Lim, Jang-Seob;Moon, Chae-Ju
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.05a
    • /
    • pp.50-54
    • /
    • 2000
  • Recently, the HFPD measurement testing is widely used in partial discharge measurement of HV machines because HFPD measurement testing receives less influence of external noise and has a merit of good sensitivity. Also HFPD testing is able to offer the judgement standard of degradation level of HV machine and can detect discharge signals in live-line. Therefore it is very useful method compare to previous conventional PD testing method and effective diagnosis method in power transformer that requires live-line diagnosis. But partial discharges have very complex characteristics of discharge pattern so it is required continuous research to development of precise analysis method. In recent, the study of partial discharge is carrying out discover of initial defect of power equipment through condition diagnosis and system development of degradation diagnosis using HFPD(High Frequency Partial Discharge) detection. In this study, simulated transformer is manufactured and HFPD occurred from transformer is measured with broad band antenna in real time, the degradation grade of transformer is analyzed through produced patterns in simulated transformer according to applied voltages.

  • PDF

A Study on the Development of a Silencer and Noise Reduce for M.Tr Room (주변압기실의 소음저감 및 소음기 개발에 관한 연구)

  • Kim, Young-Dal
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.1
    • /
    • pp.111-118
    • /
    • 2006
  • Relatively high noise emitted from Transformers of in-door-substation in urban area has become the target of public complaints and the frequency is on the rise in these days due to an extension of transformer installations and new establishment of substations. The noise consist of harmonics of a specific frequency of the twice of the electricity frequency(60[Hz]), which is hard to control by using the general sound proofing techniques. In this work, several effective methods were discussed for reducing the noise from a transformer, which is transmitted through explosion preventing shutter and air tunnels. By applying to the actual site, the effects of the methods were verified.

A Study of Maglev Train Inverter and Converter Noise (자기부상열차용 인버터 및 컨버터 소음에 관한 연구)

  • Kim, Hyun-Sil;Kim, Jae-Seung;Kang, Hyun-Joo;Kim, Bong-Ki;Kim, Sang-Rul
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.346-351
    • /
    • 2002
  • Noise of the VVVF inverter and DC/DC converter, which are the most dominant noise sources of maglev train at low speed, is studied, The coils inside inverter and converter are excited by electro-magnetic forces, which results in core vibration and generations of the noise. It is found that the spectra of the noise show many harmonics, where there exist several different fundamental frequencies. Some noise reducing techniques are known for the transformer noise such as changing stiffness and using different core materials, which make less electrostatic responses, and consequently less noise. In this study, it is shown that the most effective and feasible noise reducing method is to increase the switching frequencies of the inverter and converter, where peaks in higher frequency are significantly reduced.

  • PDF

Measurement of Magnetostriction of 3phase Transformer for Design of the low noise transformer (저소음 변압기 설계를 위한 삼상 변압기의 자왜 특성 측정)

  • Um, Doo-Jong;Cho, Hyun-Jin;Lim, Jeong-Hyeok;Koh, Chang-Seop
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.770-771
    • /
    • 2015
  • 이번 연구에서는 변압기의 소음의 주원인 중 하나인 자왜를 실제 변압기의 시험 모델을 통하여 자왜를 측정하고, 이에 대하여 저소음 변압기 설계를 위해 어떻게 해야 할지를 생각해본다.

  • PDF

A Study on PD Detection Methods for Cast-resin Dry-type Transformers (몰드변압기의 부분방전 검출기술에 관한 연구)

  • Park, Chan-Yong;Park, Dae-Won;Choi, Jae-Sung;Kil, Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.9
    • /
    • pp.786-791
    • /
    • 2009
  • Transformer failures are mostly due to partial discharges (PDs) caused by the deteriorated insulation. It is, therefore, important to monitor PD occurrence in insulation system and prevent their deterioration. The presented paper deals with a PD detection method by a capacitive probe, which easily apply to cast - resin dry - type transformers. The PD detection system consists of a capacitive probe and a low noise amplifier having the frequency bandwidth of 500 $Hz{\sim}30$ MHz. In the experimental set-up, sensitivity of the system is 7.16 mV/pC.

Development of Diagnostic Algorithm Using Location of PD at Transformer (변압기 부분방전 위치검출을 통한 진단알고리즘 개발)

  • Lee, Seung-Whan;Oh, Hak-Joon;Shin, Seung-Shik;Yun, Man-Soo;Jung, Chan-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.2178-2180
    • /
    • 2001
  • This paper is the study for the separating noise signal that is the greatest problem in ultrasonic signal measurement which is one of the method of estimation of partial discharge signals location. Because we can measure the number and location of signal, it is possible to distinguish between the signal of partial discharge and the external noise. Therefore, we can develop the credibility of detecting of insulating deterioration in transformer.

  • PDF

A Study on Energy-Saving High-Frequency Inverter Welding Machine with Noise Cut Transformer (노이즈 차폐 트랜스로 구성한 에너지 절감형 고주파 인버터 용접기 개발에 대한 연구)

  • Kang, Yun-Ki;Chae, Young-Min;Choe, Gyu-Ha;Ro, Chung-Yun
    • Proceedings of the KIEE Conference
    • /
    • 1995.07a
    • /
    • pp.420-423
    • /
    • 1995
  • The electric arc welding machine with high-frequency inverter is studied in this paper which could make more saving in energy than conventional ones with inherent low efficiency. The inverter circuit has been already adopted to special welding machines such as MIG and TIG for improving operating performances so much. But this adoption has not be applied to conventional ac arc welding machine until now. The proposed technology for higher efficiency is to apply the high frequency inverter, together with noise-cut transformer. Overall output characteristics are investigated in aspect of cost and circuit performance. The proposed system is conducted practical experiments using PWM controller.

  • PDF

The Analysis of VHF/UHF PD and 3d-PD Pattern (3d-PD 패턴과 VHF/UHF PD 신호의 고찰)

  • Lim, Jang-Seob;Park, Yong-Sik;Park, Byoung-Ha;Han, Sok-Kyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05b
    • /
    • pp.75-78
    • /
    • 2001
  • Recently, the HFPD measurement testing is widely used in partial discharge measurement of HV machines because HFPD measurement testing receives less influence of external noise and has a merit of good sensitivity. Also HFPD testing is able to offer the judgement standard of degradation level of HV machine and can detect discharge signals in live-line. Therefore it is very useful method compare to previous conventional PD testing method and effective diagnosis method in power transformer that requires live-line diagnosis. But partial discharges have very complex characteristics of discharge pattern so it is required continuous research to development of precise analysis method. In recent, the study of partial discharge is carrying out discover of initial defect of power equipment through condition diagnosis and system development of degradation diagnosis using HFPD(High Frequency Partial Discharge) detection. In this study, simulated transformer is manufactured and HFPD occurred from transformer is measured with broad band antenna in real time, the degradation grade of transformer is analyzed through produced patterns in simulated transformer according to applied voltages.

  • PDF

The Effect Analysis in case of the Countermeasure and Trouble-Examples for the Noise of Control Equipment System (제어설비 계통에서의 노이즈장해 사례 및 대책별 효과 분석)

  • Kim, Hong-Ju;Yoo, Sang-Bong;Lee, Ho-Sung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.6
    • /
    • pp.75-81
    • /
    • 2005
  • Recently an increase of sensor and power trandusers in control equipment system has caused many kinds of noise the mis-operation equipment and demage program memories of control circuits. In this paper, the noise character of the various control equipment system has been measured and analyzed. Additionally, the countermeasure to reduce noise like as Noise Cut Transformer, Equipotential Bonding, Power Noise Rejector, Noise Filter has been applied and confirmed the effective results to solve the trouble of noise.