• Title/Summary/Keyword: Transfer rate

Search Result 4,702, Processing Time 0.041 seconds

Effects of Combined Chlorine Dioxide Gas Treatment Using Low-Concentration Generating Sticks on the Microbiological Safety and Quality of Paprika during Storage (저농도 서방형 이산화염소 가스 병합처리가 파프리카의 저장 중 미생물 성장과 품질에 미치는 영향)

  • Kang, Ji Hoon;Park, Shin Min;Kim, Hyun Gyu;Son, Hyun Jung;Song, Kyoung Ju;Cho, Miae;Kim, Jong Rak;Lee, Jeong Yong;Song, Kyung Bin
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.45 no.4
    • /
    • pp.619-624
    • /
    • 2016
  • Chlorine dioxide ($ClO_2$) gas treatment (75 ppmv, 30 min) has been suggested to improve the microbial safety of postharvest paprika in a previous study. Based on these results, in this study, an additional combined treatment using low-concentration $ClO_2$ gas-generating sticks (3 ppmv) in paprika samples during storage was carried out at $8^{\circ}C$ and 90% relative humidity to further enhance the quality and reduce the decay rate of paprika for the purpose of lengthy storage. After the combined treatment, the initial populations of total aerobic bacteria as well as yeast and molds in the paprika samples decreased by 3.04 and 2.70 log CFU/g, respectively, compared with those of the control samples, and this microbial inactivation was maintained by the low-concentration $ClO_2$ gas-generating sticks during storage. In particular, the decay rate of samples with combined treatment was significantly lower than that of the control. Vitamin C content, hardness, and color quality parameters of paprika samples were not altered by treatment, while weight loss of the samples treated with the combined $ClO_2$ gas was lower than that of the control during storage. These results indicate that the combination of two different $ClO_2$ gas treatments is effective for retaining the quality of paprika during prolonged storage.

Safety and Efficacy of Peripherally Inserted Central Catheters in Terminally Ill Cancer Patients: Single Institute Experience

  • Park, Kwonoh;Lim, Hyoung Gun;Hong, Ji Yeon;Song, Hunho
    • Journal of Hospice and Palliative Care
    • /
    • v.17 no.3
    • /
    • pp.179-184
    • /
    • 2014
  • Purpose: We investigated the safety and efficacy of peripherally inserted central catheters (PICCs) in terminally ill cancer patients. Methods: A retrospective review was conducted on patients who underwent PICC at the hospice-palliative division of KEPCO (Korea Electric Power Corporation) Medical Center between January 2013 and December 2013. All PICCs were inserted by an interventional radiologist. Results: A total of 30 terminally ill cancer patients received the PICC procedure during the study period. Including one patient who had had two PICC insertions during the period, we analyzed a total of 31 episodes of catheterization and 571 PICC days. The median catheter life span was 14.0 days (range, 1~90 days). In 25 cases, catheters were maintained until the intended time (discharge, transfer, or death), while they were removed prematurely in six other cases (19%; 10.5/1000 PICC days). Thus, the catheter maintenance success rate was 81%. Of those six premature PICC removal cases, self-removal due to delirium occurred in four cases (13%; 7.0/1000 PICC days), and catheter-related blood stream infection and thrombosis were reported in one case, each (3%; 1.8/1000 PICC days). Complication cases totaled eight (26%; 14.1/1000 PICC days). The time to complication development ranged from two to 14 days and the median was seven days. There was no PICC complication-related death. Conclusion: Considering characteristics of terminally ill cancer patients, such as a poor general condition, vulnerability to trivial damage, and a limited period of survival, PICC could be a safe intravenous procedure.

One-stage Repair of Aortic Arch Anomalies and Intracardiac Defects through Median Sternotomy (정중 흉골절개를 통한 대동맥궁 기형과 심기형의 일차교정술)

  • Chang Yun Hee;Lee Sang Kwon;Lee Hyung Doo;Kim Siho;Yie Kilsoo;Woo Jong Soo;Lee Young Seok;Sung Si Chan
    • Journal of Chest Surgery
    • /
    • v.38 no.4 s.249
    • /
    • pp.291-300
    • /
    • 2005
  • One-stage repair of aortic arch anomalies and intracardiac defects through median sternotomy has been recently adopted by many institutions since it is known to be safer than the staged repair. The early and midterm results of the one-stage repair of aortic arch anomalies and intracardiac defects were retrospectively evaluated. Material and Method: 45 patients who underwent one-stage repair of aortic arch anomalies and intracardiac defects performed by one surgeon from January 1996 to July 2003 were included in this retrospective study. The median age of repair was 16 days (range, 3 days$\~$23.7 months) and the mean weight was $3.62\;\pm\;1.30 kg$. Thirty one $(68.9\%)$ had coarctation and 14 $(31.1\%)$ had interrupted aortic arch. Associated intracardiac anomalies were VSD in 31 patients (VSD group), TGA or Taussig-Bing anomaly in 10 (TGA group), and others in 4 (ASD in 1, aortopulmonary window 1, truncus arteriosus 1, aortic and mitral stenoses 1, miscellaneous group). The arch obstruction was repaired with end-to-side anastomosis in 23 patients and end-to-end anastomosis in 22. Result: Overall postoperative hospital mortality was $22.2\%\;(10/45);\;16.1\%$ (5/31) in VSD group, $40\%$ (4/10) in TGA group, and$25\%$ (1/4) in miscellaneous group. There was no mortality in VSD group since 1998, and the mortality in TGA group has remarkably reduced since technical modification for coronary transfer was adopted $(75\%\;vs\;16.7\%)$. There was no postoperative seizure or other neurological complications. Postoperative aortic restenosis occurred in 5 patients $(5/35,\;14.3\%)$. Two patients underwent balloon aortoplasty with successful results. There was no reoperation. There was one late death caused by pneumonia 5 months after the operation. Two-year actuarial survival rate including operative death was $72.9\%$. Conclusion: The operative mortality of one-stage repair has been reduced with time and aortic restenosis rate was also acceptable. We concluded that this procedure is a reproducible procedure for aortic arch anomalies associated with intracardiac defects.

Monitoring of Pesticide Residues in Leafy Vegetables Collected from Wholesale and Traditional Markets in Cheongju (청주지역 도매 및 재래시장 유통 엽채류 중 잔류농약 모니터링)

  • Noh, Hyun-Ho;Park, Young-Soon;Kang, Kyung-Won;Paik, Hyo-Kyung;Lee, Kwang-Hun;Lee, Jae-Yun;Yeop, Kyung-Won;Choi, Song-Rim;Kyung, Kee-Sung
    • The Korean Journal of Pesticide Science
    • /
    • v.14 no.4
    • /
    • pp.381-393
    • /
    • 2010
  • In order to monitor the residual characteristics of the pesticides in leafy vegetables selling at wholesale markets and traditional markets in Cheongju, a total of 180 samples of 15 leafy vegetables, such as broccoli, celery, chard, chicory, Chinese vegetable, Chwinamul, crown daisy, Korean cabbage, leek, lettuce, perilla leaves, Shinsuncho, spinach, welsh onion and young radish, were purchased from the wholesale markets and traditional markets in June and August in 2010 and the pesticide residues in them were analyzed by multiresidue analysis method using GLC, HPLC and GC-MSD. Seven pesticides were detected from 12 samples out of total 180 samples collected, representing detection rate was 6.7%. In case of the samples collected from markets in June, four pesticides including tefluthrin were detected from six samples and in case of the samples collected from markets in August, three pesticides including pendimethalin were detected from three samples. The MRL-exceeding rate of pesticides detected from leafy vegetables was 0.6%. The pesticide exceeded its MRL was azoxystrobin detected from crown daisy and many pesticides were not registered to the crops, excepting that azoxystrobin detected from Chwinamul and tefluthrin from leek. Estimated daily intakes (EDIs) of the pesticides detected from leafy vegetables were less than 7% of their acceptable daily intakes (ADIs), representing that residue levels of the pesticides detected were evaluated as safe.

Scapular Free Flap (유리 견갑 피판 이식술)

  • Chung, Duke-Whan;Han, Chung-Soo;Yim, Chang-Moo
    • Archives of Reconstructive Microsurgery
    • /
    • v.5 no.1
    • /
    • pp.24-34
    • /
    • 1996
  • There are many kinds of free flaps for management of extensive soft tissue defect of extremities in orthopaedic field. Free vascularized scapular flap is one of the most useful and relatively easy to application. This flap has been utilize clinically from early eighties by many microsurgical pioneers. Authors performed 102 cases of this flap from 1984 to 1995. We have to consider about the surgical anatomy of the flap, technique of the donor harvesting procedures, vascular varieties and anatomical abnormalities and success rate and the weak points of the procedure. This flap nourished by cutaneous branches from circumflex scapular vessels emerges from the lateral aspect of the subscapular artery 2.5-5cm from its lateral origin passing through the triangular space(bounded by subscapularis, teres minor, teres major, long head of triceps). The terminal cutaneous branch runs posteriorly around the lateral border of the scapular and divided into two major branches, those transeverse horizontally and obliquely to the fascial plane of overlying skin of the scapular body. We can utilize these arteries for scapular and parascapular flap. The vascular pedicle ranged from 5 to 10 cm long depends on the dissection, usually two venae comitantes accompanied circumflex scapular artery and its major branches. The diameter of the circumflex scapular artery is more than 1mm in adult, rare vascular variation. Surgical techniques : The scapular flap can be dissected conveniently with prone or lateral decubitus position, prone position is more easier in my experience. There are two kinds of surgical approaches, most of the surgeon prefer elevation of the flap from its outer border towards its base which known easier and quicker, but I prefer elevation of the flap from its outer border because of the lowering the possibilities of damage to vasculature in the flap itself which runs just underneath the subcutaneous tissue of the flap and provide more quicker elevation of the flap with blunt finger dissection after secure pedicle dissection and confirmed the course from the base of the pedicle. There are minimal donor site morbidity with direct skin closure if the flap size is not so larger than 10cm width. This flap has versatility in the design of the flap shape and size, if we need more longer and larger one, we can use parascapular flap or both. Even more, the flap can be used with latissimus dorsi musculocutaneous flap and serratus anterior flap which have common vascular pedicle from subscapular artery, some instance can combined with osteocutaneous flap if we include the lateral border of the scapular bone or parts of the ribs with serratus anterior. The most important shortcoming of the scapular free flap is non sensating, there are no reasonable sensory nerves to the flap to anastomose with recipient site nerve. Results : Among our 102 cases, overall success rate was 89%, most of the causes of the failure was recipient site vascular problems such as damaged recipient arterial conditions, and there were two cases of vascular anomalies in our series. Patients ages from 3 years old to 62 years old. Six cases of combined flap with latissimus dorsi, 4 cases of osteocutaneous flap for bone reconstruction, 62 parascapular flap was performed - we prefer parascapular flap to scapular. Statistical analysis of the size of the flap has less meaningful because of the flap has great versatility in size. In the length of the pedicle depends on the recipient site condition, we can adjust the pedicle length. The longest vascular pedicle was 14 cm in length from the axillary artery to the enter point cutaneous tissue. In conclusion, scapular free flap is one of the most useful modalities to manage the large intractable soft tissue defect. It has almost constant vascular pedicle with rare anatomical variation, easy to dissect great versatility in size and shape, low donor morbidity, thin and hairless skin.

  • PDF

Inferring the Transit Trip Destination Zone of Smart Card User Using Trip Chain Structure (통행사슬 구조를 이용한 교통카드 이용자의 대중교통 통행종점 추정)

  • SHIN, Kangwon
    • Journal of Korean Society of Transportation
    • /
    • v.34 no.5
    • /
    • pp.437-448
    • /
    • 2016
  • Some previous researches suggested a transit trip destination inference method by constructing trip chains with incomplete(missing destination) smart card dataset obtained on the entry fare control systems. To explore the feasibility of the transit trip destination inference method, the transit trip chains are constructed from the pre-paid smart card tagging data collected in Busan on October 2014 weekdays by tracing the card IDs, tagging times(boarding, alighting, transfer), and the trip linking distances between two consecutive transit trips in a daily sequences. Assuming that most trips in the transit trip chains are linked successively, the individual transit trip destination zones are inferred as the consecutive linking trip's origin zones. Applying the model to the complete trips with observed OD reveals that about 82% of the inferred trip destinations are the same as those of the observed trip destinations and the inference error defined as the difference in distance between the inferred and observed alighting stops is minimized when the trip linking distance is less than or equal to 0.5km. When applying the model to the incomplete trips with missing destinations, the overall destination missing rate decreases from 71.40% to 21.74% and approximately 77% of the destination missing trips are the single transit trips for which the destinations can not be inferable. In addition, the model remarkably reduces the destination missing rate of the multiple incomplete transit trips from 69.56% to 6.27%. Spearman's rank correlation and Chi-squared goodness-of-fit tests showed that the ranks for transit trips of each zone are not significantly affected by the inferred trips, but the transit trip distributions only using small complete trips are significantly different from those using complete and inferred trips. Therefore, it is concluded that the model should be applicable to derive a realistic transit trip patterns in cities with the incomplete smart card data.

Evaluation of Single and Stacked MFC Performances under Different Dissolved Oxygen Concentrations in Cathode Chamber (환원전극 DO 농도에 따른 단일 및 직렬연결 미생물연료전지 전기발생량 평가)

  • Yu, Jae-Cheul;Lee, Tae-Ho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.4
    • /
    • pp.249-255
    • /
    • 2009
  • The performance of microbial fuel cell (MFC) can be affected by many factors including the rate of organic matter oxidation, the electron transfer to electrode by electrochemical bacteria, proton diffusion, the concentration of electron acceptor, the rate of electron acceptor reduction and internal resistance. the performance of MFC using oxygen as electron acceptor can be influenced by oxygen concentration as limit factors in cathode compartment. Many studies have been performed to enhance electricity production from MFC. The series or parallel stacked MFC connected several MFC units can use to increase voltages and currents produced from MFCs. In this study, a single MFC (S-MFC) and a stacked MFC (ST-MFC) using acetate as electron donor and oxygen as electron acceptor were used to investigate the influence of dissolved oxygen (DO) concentrations in cathode compartment on MFC performance. The power density (W/$m^3$) of S-MFC was in order DO 5 > 3 > 7 > 9 mg/L, the maximum power density (W/$m^3$) of S-MFC was 42 W/$m^3$ at DO 5 mg/L. The power density (W/$m^3$) of ST-MFC was in order DO 5 > 7 > 9 > 3 mg/L and the maximum power density (W/$m^3$) of STMFC was 20 W/$m^3$ at DO 5 mg/L. These results suggest that the DO concentration of cathode chamber should be considered as important limit factor of MFC operation and design for stacked MFC as well as single MFC. The results of ST-MFC operation showed the voltage decrease of some MFC units by salt formation on the surface of anode, resulting in decrease total voltage of ST-MFC. Therefore, connecting MFC units in parallel might be more appropriate way than series connections to enhance power production of stacked MFC.

Use of Nitrate and Ferric Ion as Electron Acceptors in Cathodes to Improve Current Generation in Single-cathode and Dual-cathode Microbial Fuel Cells (Single-cathode와 Dual-cathode로 구성된 미생물연료전지에서 전류발생 향상을 위한 전자수용체로서의 Nitrate와 Ferric ion의 이용)

  • Jang, Jae Kyung;Ryou, Young Sun;Kim, Jong Goo;Kang, Youn Koo;Lee, Eun Young
    • Microbiology and Biotechnology Letters
    • /
    • v.40 no.4
    • /
    • pp.414-418
    • /
    • 2012
  • The quantity of research on microbial fuel cells has been rapidly increasing. Microbial fuel cells are unique in their ability to utilize microorganisms and to generate electricity from sewage, pig excrement, and other wastewaters which include organic matter. This system can directly produce electrical energy without an inefficient energy conversion step. However, with MFCs maximum power production is limited by several factors such as activation losses, ohmic losses, and mass transfer losses in cathodes. Therefore, electron acceptors such as nitrate and ferric ion in the cathodes were utilized to improve the cathode reaction rate because the cathode reaction is very important for electricity production. When 100 mM nitrate as an electron acceptor was fed into cathodes, the current in single-cathode and dual-cathode MFCs was noted as $3.24{\pm}0.06$ mA and $4.41{\pm}0.08$ mA, respectively. These values were similar to when air-saturated water was fed into the cathodes. One hundred mM nitrate as an electron acceptor in the cathode compartments did not affect an increase in current generation. However, when ferric ion was used as an electron acceptor the current increased by $6.90{\pm}0.36$ mA and $6.67{\pm}0.33$ mA, in the single-cathode and dual-cathode microbial fuel cells, respectively. These values, in single-cathode and dual-cathode microbial fuel cells, represent an increase of 67.1% and 17.6%, respectively. Furthermore, when supplied with ferric ion without air, the current was higher than that of only air-saturated water. In this study, we attempted to reveal an inexpensive and readily available electron acceptor which can replace platinum in cathodes to improve current generation by increasing the cathode reaction rate.

A Survey of Staphylococcus aureus Contamination and Antibiotic Susceptibility in Retail Meat (국내유통 축산물에서의 Staphylococcus aureus 오염도 및 항생제 감수성 조사)

  • Yang, Jung-Im;Lee, Sun-Min;Lee, Gil;Lee, Hwan-Ju;Kim, Min-Kyu;Jeong, Eun-Jeong;Cha, Yong-Jun
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.37 no.4
    • /
    • pp.528-533
    • /
    • 2008
  • Staphylococcus aureus is a pathogene of major concern in livestock products. This study was conducted to test imported and domestic meat sold by retail stores for the presence S. aureus. In addition, the antibiotic susceptibility of any S. aureus found was also evaluated. The overall isolation rate of S. aureus was 20.2% (13.9% in pork and 33.8% in beef) in retail meats. The percentage of imported meats found to contain S. aureus (33.3% in pork and 40.4% in beef) was higher than that of domestic meat (13.0% in pork and 14.7% in beef). In addition, the detection rate of S. aureus was higher in raw material meat than in ready to cook packaged meat. When the antibiotic susceptibility of S. aureus isolated from the meat products was evaluated, ampicillin was found to be the highest (76.5%), followed by penicillin (75.3%), tetracycline (27.1%) and erythromycin (21.2%). Penicillin and tetracycline resistant were detected in 55.6% and 13.3% of the beef isolates, respectively, and 97.5% and 42.5% of the pork isolates, respectively. The tetracycline and erythromycin resistant plasmids of the isolated strain were transferred into S. aureus DPRMM2429 by the filter mating method and the frequencies of transfer was found to be $1.1{\times}10^{-5}{\sim}1.9{\times}10^{-9}$ and $1.2{\times}10^{-5}{\sim}4.0{\times}10^{-8}$ respectively.

Optimization of Separation Process of Bioflavonoids and Dietary Fibers from Tangerine Peels using Hollow Fiber Membrane (중공사 막을 이용한 감귤 과피 bioflavonoids 분리 및 식이 섬유 회수 공정 최적화)

  • Lee, Eun-Young;Woo, Gun-Jo
    • Korean Journal of Food Science and Technology
    • /
    • v.30 no.1
    • /
    • pp.151-160
    • /
    • 1998
  • Tangerine peel is mostly discarded as waste in citrus processing. However, tangerine peel contains besides dietary fibers bioflavonoids such as naringin and hesperidin which act as antimicrobials and blood pressure depressants, respectively. A continuous membrane separation process was optimized for the production of bioflavonoids relative to feed flow rate, transmembrane pressure, temperature, and pH. The tangerine peel was blended with 7.5 times water volume and the extract was prefiltered through a prefiltration system. The prefiltered extract was ultrafiltered in a hollow fiber membrane system. The flux and feed flow rate didn't show any apparent correlation, but we could observe a mass-transfer controlled region of over 8 psi. When temperature increased from $9^{\circ}C\;to\;25^{\circ}C$, the flux increased about $10\;liters/m^2/min\;(LMH)$ but between $25^{\circ}C\;and\;33^{\circ}C$, the flux increased only 2 LMH. At every transmembrane pressure, the flux of pH 4.8 was the most highest and the flux at pH 3.0 was lower than that of pH 6.0, 7.0, or 9.0. Therefore, the optimum operating conditions were 49.3 L/hr. 10 psi, $25^{\circ}C$, and pH 4.8. Under the optimum conditions, the flux gradually decreased and finally reached a steady-state after 1 hr 50 min. The amount of dietary fibers in 1.0 g retentate in each separation step was analyzed and bioflavonoids concentration in each permeate was measured. The contents of total dietary fiber in the 170 mesh retentate and soluble dietary fiber in the prefiltered retentate were the highest. Naringin and hesperidin concentration in the permeate were $0.45{\sim}0.65\;mg/g\;and\;5.15{\sim}6.86\;mg/g$ respectively, being $15{\sim}22$ times and $79{\sim}93$ times higher than those in the tangerine peel. Therefore, it can be said that PM 10 hollow fiber membrane separation system may be a very effective method for the recovery of bioflavonoids from tangerine peel.

  • PDF