• 제목/요약/키워드: Transfer rate

검색결과 4,698건 처리시간 0.027초

자동차용 에어컨의 고밀도 응축기(SCC)에서 배플의 위치 변화에 따른 성능향상에 관한 연구 (Effects of Baffle Location on the Performance of a Super Compact Condenser in an Automotive Air Conditioning System)

  • 이명재;박복춘;백병준;염동석;한창섭
    • 한국자동차공학회논문집
    • /
    • 제5권6호
    • /
    • pp.128-140
    • /
    • 1997
  • A new super compact condenser(SCC), which has been developed recently is especially suitable for an alternative refrigerant HFC-134a due to its high performance and compactness. The SCC is composed of two pipe headers, baffles, narrow multi-rectangular channels, and louvered fin arrays. Alternating inlet and outlet by the inserted baffles in pipe headers guide refrigerant to and from the narrow multi-rectangular channels. Since the flow rate and its lengh are changed depending on the number and location of baffles, the corresponding pressure drop and heat transfer rate are changed. The present study aims to theoretically and experimentally investigate the effects of baffle location and its number on the pressure drop and thermal performance of the SCC with 40 multi-rectangular channels. The results show that the present method provides an acceptable prediction of pressure drop and heat transfer rate for a 4 pass SCC. However, the model significantly under predicts the performance of a 3 pass SCC, which may be attributed to the phase separation of refrigerant flowing through header pipes. Pressure drop is more signifi- cantly influenced than heat transfer rate by the baffle location.

  • PDF

냉동시스템의 운전조건에 따른 열교환기 내장형 어큐뮬레이터의 성능 특성 (Performance Characteristics of Accumulator Heat Exchangers with Operating Conditions of a Refrigeration System)

  • 강훈;박차식;전종욱;김용찬
    • 설비공학논문집
    • /
    • 제18권12호
    • /
    • pp.984-991
    • /
    • 2006
  • The applications of multi air-conditioners into multiplex and high-rise buildings have been increased by replacing central air-conditioning systems. The pipe length and altitude difference between the indoor and outdoor units can be increased based on installation conditions, which may increase the possibility of flash gas generation at the expansion device inlet. The flash gas generation causes rapid reduction of refrigerant flow rate passing through the expansion device, yielding lower system efficiency. Accumulator heat exchangers have been widely used in multi air-conditioners in order to minimize flash gas generation and obtain system reliability. However, the studies on the heat transfer characteristics and pressure drops of accumulator heat exchangers are very limited in open literature. In this study, the heat transfer rates and pressure drops of accumulator heat exchangers were measured with refrigerant flow rate and operating conditions by using R-22. The heat transfer rate increased with the increase of refrigerant flow rate, while subcooling decreased. The heat transfer rate enhanced with the reduction of inlet superheat and subcooling due to the increased temperature difference between the accumulator and inner heat exchanger.

공공연구기관의 기술이전모형연구와 그 정책적 함의 발표분야 : 기술경제, 기술정책분야(기술이전)

  • 류태규;박종복;이정동;김태유
    • 기술경영경제학회:학술대회논문집
    • /
    • 기술경영경제학회 2002년도 제21회 하계학술발표회 논문집
    • /
    • pp.203-223
    • /
    • 2002
  • In Korea, Public Research Institutes(PRIs) are today faced with the challenges of creating values by transferring technologies in store within themselves to private commercial sector. Recently, It has been increasingly pointed out that PRIs have the poor capability to valuate prospective technologies of their own, and don't run the reasonable technology transfer mechanism in terms of establishing royalty rate and initial payment, designing remuneration to inventor, screening qualified licensee, and controlling the moral hazard. This paper develops an enhanced mathematical model of technology transfer from a PRI to a private industrial firm with including the inventor as an important player. The model is made up of the main part which derives the optimal royalty rate by maximizing the social welfare and sharing risk fairly between players and some sub-parts. The one sub-part is a principal-agent model which makes it possible to control the moral hazard of inventors, and the other part provides the criteria for screening appropriate licensees. Moreover, the moral hazard between inventor and licensee is addressed by introducing the cost reduction function of efforts exerted by them. The model is able to relate the optimal royalty rate to the parameters that represent the environments under which the concerned parties operate. Especially, the ratio of initial payment over the value of transferred technology is calculated from the binding relation with the royalty rate. The paper shows that the model suggested here is more enhanced by comparing with the existing technology transfer mechanism. Finally, the paper allows us to find better strategies for effective technology transfer and further develop more sophisticated technology transfer model.

  • PDF

고부하 유기성 폐수처리를 위한 분리막 결합형 순산소 고효율 포기장치의 총괄 산소전달효율 평가 (Comparison of Overall Oxygen Transfer Coefficient in the Membrane Coupled High Performance Reactor for a High Organic Loading Wastewater Treatment)

  • 강범희;임경호;이상민
    • 한국물환경학회지
    • /
    • 제26권1호
    • /
    • pp.81-88
    • /
    • 2010
  • This study was conducted to find the capability of comparison of overall oxygen transfer coefficient in the membrane coupled high performance reactor (MPHCR) in treating high organic loading wastewater. Effluent quality had been analyzed while the influent organic loading rate was changed from 2 to $7kg\;COD/m^3{\cdot}day$. The oxygen transfer coefficients had been investigated using two-phase nozzle for operating variables which were internal circulation flowrate (5~8 L/min), air flow rate (0.0125~0.2 L/min), liquid temperature ($10{\sim}20^{\circ}C$), and pure-oxygen flow rate (0.0125~0.2 L/min). The overall oxygen transfer coefficient was increased with flowrate of internal circulation and air and high temperature. Especially, internal circulation flow rate showed distinct effect on overall oxygen transfer coefficient due to an increase of gas holdup and air-liquid contract area by two-phase nozzle. In the high range of organic loading rate from 4 to $7kg\;COD/m^3{\cdot}day$, the removable efficiency of COD was 91%. Conventional activated sludge process usually treat organic loading from 0.32 to $0.64kg\;COD/m^3{\cdot}day$ however, the MPHCR can treat 10 to 20 times higher if it would be compared to the conventional activated sludge process. Foaming problem often happened and caused biomass wash out of the reactor, therefore, the foaming should be controlled for the enhanced operation.

소식재배용 이앙기 모판 이송간격에 따른 이앙정확도 분석 (Analysis of Transplanting Accuracy of Rice Transplanter for Low density Planting According to Transfer Distance to Seedling Tray)

  • 김원경;이상희;최덕규;박석호;강연구;문석표;천창욱;장성혁
    • 드라이브 ㆍ 컨트롤
    • /
    • 제21권2호
    • /
    • pp.30-35
    • /
    • 2024
  • Domestic rice is more expensive than imported products, so it is necessary to reduce production costs to secure competitiveness. Low-density planting developed in Japan is a cultivation technology that reduces labor and production costs without yield loss. The area of low-density cultivation is continuously increasing. However, research on how rice transplanters adapt to low-density planting has not been conducted. Therefore, this study was carried out to determine the optimal working conditions of a rice transplanter for low-density planting. Three types of rice transplanters were used and treated based on 3 conveying distance levels. The number of picked seedlings, pick missing rate, the number of planted seedlings, and the mis-planted rate were investigated to evaluate planting accuracy according to the transfer distance to the seedling tray. The results showed that the number of planted seedlings was 4.31~4.95 EA with an L1 seedling tray transfer distance (horizontal 9 mm, vertical 8 mm), but the mis-planted rate was higher than in other conditions. At L2 (horizontal 9 mm, vertical 10 mm) and L3 (horizontal 11 mm, vertical 8 mm) transfer distance conditions, the number of planted seedlings were 4.89-5.68 EA and 4.69-5.66 EA, respectively, with a low mis-planted rate of less than 3%. The results showed that if the transfer distance is adjusted properly, a rice transplanter can be used for low-density planting with high planting accuracy.

한우 및 젖소에서 과배란 처리를 이용한 체내수정란 생산과 신선 및 동결 수정란 이식 결과 (Production of In-Vivo Embryos by Superovulation and Result of Transfer with Fresh or Frozen Embryos for Hanwoo and Holstein Cattle)

  • 김용준;송재웅;서세현;정구남;김용수;이해리;신동수;조성우;김수희
    • 한국수정란이식학회지
    • /
    • 제19권3호
    • /
    • pp.209-218
    • /
    • 2004
  • 가축에서 생산성을 높이기 위해 사용되는 수정란이식술의 실용성을 알아보기 위하여 한우 및 젖소 36두로부터 과배란 처리를 하여 신선수정란은 25두에, 동결수정란은 17두에, 쌍태 생산을 위한 수정란 두 개 이식은 13두 수란우에 이식되어 그 생산 결과를 조사하였다. 1 과배란을 위한 호르몬 처리후 반응을 나타낸 공란우는 75.0%이었다. 2. 황체수와 비교하여 채란된 수정란 율은 91.8% 이었다. 3. 비외과적으로 채란된 전체 난자 중 생존성이 있는 배반포는 66.4%이었고, 이식 가능한 배반포는 48.6%이었다. 4. 간이채란법으로 시도된 one-catheter method에 의한 양 자궁 관류성공률은 75.0%이었다. 5. 신선 수정란을 이식후 분만결과에 따른 수태율은 60.0%이었다. 6. 동결수정란을 융해하여 이식후 분만결과에 따른 수태율은 35.3%이었다. 7. 쌍태 생산을 위한 수정란 두 개 이식결과에서 신선수정란 사용시 28.6%, 동결수정란 사용시 16.7%의 쌍태분만을을 나타내었다. 8.수정란 이식 후 생산된 산자에서 수컷의 비율은 56.3%이었다. 9. 수정란 이식 계절에 따른 분만 결과에서 여름에 이식시 가장 낮은 수태율을 나타내었다.

항생물질발효에서의 산소전달 및 흡수속도에 관한 연구 (The Oxygen Transfer and Oxygen Uptake in Antibiotic Fermentation using Streptomyces kanamyceticus)

  • Lee, Kye-Joon;Moo Bae
    • 한국미생물·생명공학회지
    • /
    • 제10권3호
    • /
    • pp.223-226
    • /
    • 1982
  • 통기발효에서 중요한 통기 및 진탕효과를 측정함에 있어 공기로부터 물속으로 용존해 가는 산소의 전달속도와, 용존된 산소가 미생물에 의해 흡수되는 속도를 산출하였다. 항생물질발효에서 통기효과는 현저하였으며, 배양시간에 따른 산소흡수 속도와 비산소흡수 속도가 변화하는 것을 알았다. 이러한 변화는 대사이차 산물인 항생물질생합성의 생화학적인 전환에 기인하는 것으로 판단된다.

  • PDF

폐열회수형 환기장치 개발에 관한 연구 (Study on the Development of Heat Recovery Ventilator)

  • 조동현;임태우
    • 수산해양교육연구
    • /
    • 제19권3호
    • /
    • pp.383-389
    • /
    • 2007
  • To evaluate the performance of heat exchanger with rotating porous plates, the experimental investigation was carried out under various conditions. With an equal interval of 18 mm inside the heat exchanger, the rotating porous plates are mounted. The hot and cold airs enter at opposite ends of heat exchanger and exchange heat each other. In order to measure the temperature distribution of the hot air side inside heat exchanger, the thermocouples are inserted between the plates. The first location of thermocouple is 10 mm downstream from the inlet of heat exchanger, and succeeding ten locations are aligned at an equal interval of 18 mm. As a result of the measurement, the temperature distribution inside heat exchanger was constant as the hot air temperature of inlet is low. It was found that the heat transfer rate does not depend on the variation of RPM at the lower temperature of inlet. The heat transfer rate at the higher temperature of inlet increased a little with the increase in RPM.

A Study on the Effects of System Pressure on Heat and Mass Transfer Rates of an Air Cooler

  • Jung, Hyung-Ho
    • Journal of Mechanical Science and Technology
    • /
    • 제16권5호
    • /
    • pp.696-702
    • /
    • 2002
  • In the present paper, the effects of inlet pressure on the heat and mass transfer rates of an air cooler are numerically predicted by a local analysis method. The pressures of the moist air vary from 2 to 4 bars. The psychrometric properties such as dew point temperature, relative humidity and humidity ratio are employed to treat the condensing water vapor in the moist air when the surface temperatures are dropped below the dew point. The effects of the inlet pressures on the heat transfer rate, the dew point temperature, the rate of condensed water, the outlet temperature of air and cooling water are calculated. The condensation process of water vapor is discussed in detail. The results of present calculations are compared with the test data and shows good agreements.

R410A 냉매를 사용한 열펌프용 열교환기의 형상에 따른 성능특성 연구 (A Study on Performance Characteristics of Heat Exchanger for Heat Pump with R410A Refrigerant)

  • 정규하;박윤철;오상경
    • 설비공학논문집
    • /
    • 제16권4호
    • /
    • pp.340-348
    • /
    • 2004
  • The air and refrigerant side heat transfer performances are key parameters to improve heat transfer efficiency of the heat exchanger including the fan performance. Design of the fins, treatment of the tube inside, tube diameter and tube array effect heat transfer performance of the heat exchanger. The heat exchanger is used as a condenser at cooling mode and used as an evaporator at heating mode in the heat pump system. The heat pump system uses R410A as the refrigerant. The heat exchangers are consisted with 7 mm diameter tubes with slit-type fins. The study was conducted with variation of arrangement of the refrigerant path and air flow rate and refrigerant pressure drop and heat transfer rate were measured with a code tester. The capacity of the 3 path heat exchanger is more efficient than 2 or 4 path heat exchangers in heating or cooling modes.