• 제목/요약/키워드: Transfer mode

검색결과 1,097건 처리시간 0.027초

$L_1-B_4$모드와 $L_1-B_8$모드 초음파 선형 전동기의 특성 비교 (Comparison of Characteristics between $L_1-B_4$ mode and $L_1-B_8$ mode Ultrasonic Motors)

  • 우상호;김동연;김진수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1518-1520
    • /
    • 2002
  • Purpose of this research compares best transfer speed about applied frequency and voltage using characteristic of $L_1-B_4$ mode and $L_1-B_8$ mode linear ultrasonic motor that use piezoelectric effect. By method of study, analyzed best transfer speed measuring and comparison load status that use actuality telephone card in $L_1-B_4$ mode linear ultrasonic motor and no-load status of $L_1-B_8$ mode linear ultrasonic motor. Experiment result is applied frequency(58.4Hz) in $L_1-B_4$ mode linear ultrasonic motor (load state) and the best transfer speed by 19.8[cm/s] at applied voltage(56V) point. Also, $L_1-B_8$ mode linear ultrasonic motor (no-load state) is best transfer speed by applied frequency(27.9kHz) and 32.96[cm/s] at applied voltage (50V) point.

  • PDF

Cost-Effective APF/UPS System with Seamless Mode Transfer

  • Lee, Woo-Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권1호
    • /
    • pp.195-204
    • /
    • 2015
  • In this paper, the development of a cost-effective active power filter/uninterruptible power supply (APF/UPS) system with seamless mode transfer is described. The proposed scheme employs a pulse-width-modulation (PWM) voltage-source inverter and has two operational modes. First, when the source voltage is normal, the system operates as an APF, which compensates for the harmonics and power factor while boosting the DC-link voltage to be ready for the disturbance, without an additional DC charging circuit. A simple algorithm to detect the load current harmonics is also proposed. Second, when the source voltage is out of the normal range (owing to sag, swell, or outage), it operates a UPS, which controls the output voltage constantly by discharging the DC-link capacitor. Furthermore, a seamless transfer method for the single-phase inverter between the APF mode and the UPS mode is also proposed, in which an IGBT switch with diodes is used as a static bypass switch. Dissimilar to a conventional SCR switch, the IGBT switch can implement a seamless mode transfer. During the UPS operation, when the source voltage returns to the normal range, the system operates as an APF. The proposed system has good transient and steady-state response characteristics. The APF, charging circuit, and UPS systems are implemented in one inverter system. Finally, the validity of the proposed scheme is investigated with simulated and experimental results for a prototype APF/UPS system rated at 3 kVA.

Magnetic Resonant Coupling Based Wireless Power Transfer System with In-Band Communication

  • Kim, Sun-Hee;Lim, Yong-Seok;Lee, Seung-Jun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제13권6호
    • /
    • pp.562-568
    • /
    • 2013
  • This paper presents a design of a wireless power transfer system based on magnetic resonant coupling technology with in-band wireless communication. To increase the transmission distance and compensate for the change in the effective capacitance due to the varying distance, the proposed system used a loop antenna with a selectable capacitor array. Because the increased transmission distance enables multiple charging, we added a communication protocol operated at the same frequency band to manage a network and control power circuits. In order to achieve the efficient bandwidth in both power transfer mode and communication mode, the S-parameters of the loop antennas are adjusted by switching a series resistor. Our test results showed that the loop antenna achieved a high Q factor in power transfer mode and enough passband in communication mode.

자유공간 광학과 출력 버퍼 메모리를 이용한 광 Asynchronous Transfer Mode(ATM) 교환방식 (An Optical Asynchronous Transfer Mode(ATM) Switching System Using Free Space Optics and an Output Buffer Memory)

  • 지윤규;이상신
    • 한국통신학회논문지
    • /
    • 제16권4호
    • /
    • pp.326-334
    • /
    • 1991
  • 자유공간 광학과 출력 버퍼 메모리를 이용한 Optical Asynchronous Transfer Mode(ATM) 스위칭 시스템을 제안하고, Huygens-Fresnel 원리와 렌즈 변환을 이용하여 이 스위칭 구조에 있는 분배 시스템을 분석했다. 단색관 조명의 경우, 입력 분포의푸리에 변환과 유사한 패턴이 출력평면에서 관측되었다. 부분적으로 코히런트(coherent)한 유사 단색광으로 시스템을 조명할 \ulcorner\ulcorner는, 출력평면에서 단색광 때보다 공간적으로 넓어진 빛의 세기 분포가 나타났다. 100fs 정도의 코히런트(coherent)한 단펄스는 심한 공간적 확장 없이 분배기를 전파할 수 있음을 알 수 있었다.

  • PDF

이중루프 구조를 갖는 다중모드 무선전력전송 시스템 (Multi-Mode Wireless Power Transfer System with Dual Loop Structure)

  • 한민석
    • 한국정보전자통신기술학회논문지
    • /
    • 제9권6호
    • /
    • pp.578-583
    • /
    • 2016
  • 본 논문에서는 이중루프 구조를 갖는 다중모드 무선전력전송 시스템을 제안하였다. 본 논문에서 제안한 다중모드 무선전력전송 시스템은 두 개의 서로 다른 주파수 6.78 MHz 자기공진 무선전력전송 모드와 13.56 MHz NFC 모드로 동작하는 외부 루프 모듈과 두 개의 서로 다른 주파수에서 동작하는 자기유도 표준인 WPC 모드와 PMA 모드로 동작하는 외부 루프와 연결된 내부 루프 모듈로 구성된다. 실제 상용 스마트폰 배터리 커버에 장착하기 위해 페라이트 시트를 포함한 $45{\times}90{\times}0.35mm3$ 크기에 맞춰 설계 및 최적화 되었다. 제안된 다중모드 무선전력전송 시스템은 기존의 자기유도방식 표준에 해당하는 WPC와 PMA를 지원할 뿐만 아니라 6.78 MHz 및 13.56 MHz에서 20 dB 이상의 반사손실 특성을 나타내었고 6.78 MHz 자기공진 무선충전 환경에서는 공진코일 간 70% 이상의 효율 특성을 갖는다.

MIG 용접 시 외부 전자기력이 미치는 영향에 관한 연구 (A Study on the Effect of External Electromagnetic force in MIG Welding)

  • 김재성;김용;류덕희;이보영
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2004년도 추계학술발표대회 개요집
    • /
    • pp.171-173
    • /
    • 2004
  • Electromagnetic force is one of the most important factor that effect on metal transfer mode, short-circuit rate, spatter generation rate and mechanical properties of weld metal etc. Also, shielding gas and welding current have influence on metal transfer mode in GMAW. In this paper, different ways for external electromagnetic forces are applied by attaching cylindrically rounded conducting wire solenoid on touch tip holding. With the applied electromagnetic field, the arc transfer mode changes from normal mode to rotating mode and spatter generation decreased in electromagnetic fields(N-pole). In MIG welding, the influences of electromagnetic force on the spatter generation showed different tendency as in the $CO_2$ welding. It is possible reasons were discussed.

  • PDF

변환행렬법을 이용한 케이블 권선형 배전용 변압기 귄선의 진동모드 해석 (A Vibration Mode Analysis of Cable-type Winding for Distribution Power Transformer by using Transfer Matrix Method)

  • 신판석;정현구;윤구영
    • 조명전기설비학회논문지
    • /
    • 제23권1호
    • /
    • pp.85-91
    • /
    • 2009
  • 본 논문에서는 배전계통에 사용되는 케이블 권선형 변압기에 전력계통에서 발생되는 서지나 고장전류에 의해서 변압기의 고압측 코일에 유도되는 전자력의 크기를 유한요소 전자계해석 프로그램(FLUX2D)을 이용하여 해석하고, 기계진동방정식을 이용하여 케이블형 권선의 고유진동주파수를 분석하였다. 변압기모델로서 1(MVA), 22,900/220([V]) 단상 외철형 Cable형을 선정하여, 권선의 각방향의 전자력을 분석하고, 고유진동 mode를 Transfer Matrix Method를 이용하여 계산하고 상용 프로그램(ANSYS)을 이용하여 분석한 결과와 비교하였다. 진동모드의 분석한 결과 제시한 수치해석 방법은 공학적인 오차범위 안에서 충분히 수용할 정도의 정확도를 보여주었다. 변압기 권선의 전자력과 진동모드 분석결과는 변압기의 절연설계 및 단락기계력에 의한 절연 구조 설계를 위한 유용한 자료로 활용될 수 있다.

복합환승센터 접근교통수단의 승하차 시설배치기준 (Layout Criteria of an Access Mode's on and off Facility at Multiple Transfer Centers)

  • 김시곤
    • 대한토목학회논문집
    • /
    • 제32권2D호
    • /
    • pp.95-101
    • /
    • 2012
  • 본 연구에서는 복합환승센터 접근교통수단의 정류장시설 배치기준을 개발하였다. 복합환승센터의 시설배치기준은 접근교통수단(Access Mode)의 승하차시설의 상대적인 위치선정에 관한 것으로 접근교통수단 하차 후 주교통수단(Main Mode)의 승하차 시설까지 이동거리를 최소화하도록 기준을 제시하였다. 이동거리 중 계단은 평면거리 보다 큰 가중치를 적용하였고 에스컬레이터는 평면거리 보다 적은 가중치를 적용하였다. 효과척도로서 접근교통수단별 이용자 가중평면환산거리를 채택하였다. 최종적으로는 본 연구에서 제시된 기준을 기존 김포공항에 적용하여 접근교통수단의 승하차 시설의 위치와 접근시설의 개선방안을 제시하였다.

Seamless Mode Transfer of Utility Interactive Inverters Based on Indirect Current Control

  • Lim, Kyungbae;Song, Injong;Choi, Jaeho;Yoo, Hyeong-Jun;Kim, Hak-Man
    • Journal of Power Electronics
    • /
    • 제19권1호
    • /
    • pp.254-264
    • /
    • 2019
  • This paper proposes an indirect current control technique based on a proportional resonant (PR) approach for the seamless mode transfer of utility interactive inverters. Direct-current and voltage hybrid control methods have been used for inverter control under grid-connected and islanded modes. A large bandwidth can be selected due to the structure of single-loop control. However, this results in poor dynamic transients due to sudden changes of the controller during mode changes. Therefore, inverter control based on indirect current is proposed to improve the dynamic transients by consistently controlling the output voltage under all of the operation modes. A PR-based indirect current control topology is used in this study to maintain the load voltage quality under all of the modes. The design processes of the PR-based triple loop are analyzed in detail while considering the system stability and dynamic transients. The mode transfer techniques are described in detail for both sudden unintentional islanding and islanded mode voltage quality improvements. In addition, they are described using the proposed indirect control structure. The proposed method is verified by the PSiM simulations and laboratory-scale VDER-HILS experiments.

강섬유 보강 초고성능 콘크리트의 전단 전달 모델 (Shear Transfer Strength Evaluation for Ultra-High Performance Fiber Reinforced Concrete)

  • 이지형;홍성걸
    • 한국공간구조학회논문집
    • /
    • 제15권2호
    • /
    • pp.69-77
    • /
    • 2015
  • Ultra High Performance Fiber Reinforced Concrete (UHPFRC) has a outstanding tensile hardening behaviour after a crack develops, which gives ductility to structures. Existing shear strength model for fiber reinforced concrete is entirely based on crack opening behavior(mode I) which comes from flexural-shear failure, not considering shear-slip behavior(mode II). To find out the mode I and mode II behavior on a crack in UHPFRC simultaneously, maximum shear strength of cracked UHPFRC is investigated from twenty-four push-off test results. The shear stress on a crack is derived as variable of initial crack width and fiber volume ratio. Test results show that shear slippage is proportional to crack opening, which leads to relationship between shear transfer strength and crack width. Based on the test results a hypothesis is proposed for the physical mechanics of shear transfer in UHPFRC by tensile hardening behavior in stead of aggregate interlocking in reinforced concrete. Shear transfer strength based on tensile hardening behavior in UHPFRC is suggested and this suggestion was verified by comparing direct tensile test results and push-off test results.