• 제목/요약/키워드: Transfer mode

검색결과 1,101건 처리시간 0.027초

Enhancement of Wireless Power Transfer Efficiency Using Higher Order Spherical Modes

  • Kim, Yoon Goo;Park, Jongmin;Nam, Sangwook
    • Journal of electromagnetic engineering and science
    • /
    • 제13권1호
    • /
    • pp.38-43
    • /
    • 2013
  • We derive the Z-parameters for the two coupled antennas used for wireless power transfer under the assumption that the antennas are canonical minimum scattering antennas. Using the Z-parameter and the maximum power transfer efficiency formula, we determine the maximum power transfer efficiency of wireless power transfer systems. The results showed that the maximum power transfer efficiency increases as the mode number or the radiation efficiency increases. To verify the theory, we fabricate and measure two different power transfer systems: one comprises two antennas generating $TM_{01}$ mode; the other comprises two antennas generating $TM_{02}$ mode. When the distance between the centers of the antennas was 30 cm, the maximum power transfer efficiency of the antennas generating the $TM_{02}$ mode increased by 62 % compared to that of the antennas generating the $TM_{01}$ mode.

간접전류제어방식 병렬형 계통연계 인버터의 무순단 모드절환 (Seamless Mode Transfer of Indirect Current Controlled Parallel Grid-Connected Inverters)

  • 송인종;최준수;임경배;최재호
    • 전력전자학회논문지
    • /
    • 제24권5호
    • /
    • pp.334-341
    • /
    • 2019
  • This study proposes the control strategy for the seamless mode transfer of indirect current controlled parallel grid-connected inverters. Under the abnormal grid condition, the grid-connected inverter can convert the operation mode from grid-connected to stand-alone mode to supply power to the local load. For a seamless mode transfer, the time delay problems caused by the accumulated control variable error must be solved, and the indirect current control method has been applied as one of the solutions. In this study, the design of control parameters for the proportional-resonant-based triple-loop indirect current controller and the control strategy for the seamless mode transfer of parallel grid-connected inverters are described and analyzed. The validity of the proposed mode transfer method is verified by the PSiM simulation results.

$CO_2$ 용접의 스패터 발생에 미치는 용적이행 모드의 영향 (Effect of Metal Transfer Mode on Spatter Generation of $CO_2$ Welding)

  • 강봉용;김희진
    • Journal of Welding and Joining
    • /
    • 제15권2호
    • /
    • pp.72-80
    • /
    • 1997
  • The spatter generation rate of GMA welding with $CO_2$ gas shielding was measured with the change of welding conditions such as wire feeding rate and welding voltage and then the results were analized with the accompanying changes in metal transfer mode and in bead geometry. The spatter generation rate (SGR) was relatively low not only wit the short circuit transfer but with the truely globular transfer mode. However, the SGR resulted with the mixed mode were consistantly high. The resultant wave pattern of mixed mode was due to the coexistance of short-circuit and globular transfer and characterized by the frequent appearance of instantaneous short circuit. Considering the result of SGR and that of bead geometry, it could be concluded that when the wire feeding rate (or welding current) was either low or high, the optimum bead shape could be obtained along with the low spatter generation. However, in the middle range of wire feeding rate, the optimum bead shape was only obtained in the mixed mode condition resulting in the high spatter generation.

  • PDF

Strategy for the Seamless Mode Transfer of an Inverter in a Master-Slave Control Independent Microgrid

  • Wang, Yi;Jiang, Hanhong;Xing, Pengxiang
    • Journal of Power Electronics
    • /
    • 제18권1호
    • /
    • pp.251-265
    • /
    • 2018
  • To enable a master-slave control independent microgrid system (MSCIMGS) to supply electricity continuously, the microgrid inverter should perform mode transfer between grid-connected and islanding operations. Transient oscillations should be reduced during transfer to effectively conduct a seamless mode transfer. This study uses a typical MSCIMGS as an example and improves the mode transfer strategy in three aspects: (1) adopts a status-tracking algorithm to improve the switching strategy of the outer loop, (2) uses the voltage magnitude and phase pre-synchronization algorithm to reduce transient shock at the time of grid connection, and (3) applies the hybrid-sensitivity $H_{\infty}$ robust controller instead of the current inner loop to improve the robustness of the controller. Simulations and experiments show that the proposed strategy is more practical than the traditional proportional-derivative control mode transfer and effective in reducing voltage and current oscillations during the transfer period.

마이크로그리드에서 계통연계 인버터의 자율적이며 끊김없는 모드전환 기법 (A Seamless and Autonomous Mode Transfer Method of Grid-connected Inverter in Microgrid)

  • 박성열;권민호;최세완
    • 전력전자학회논문지
    • /
    • 제24권5호
    • /
    • pp.349-355
    • /
    • 2019
  • A grid-connected inverter with critical loads should be able to supply a stable voltage to critical loads at mode change and during clearing time while detecting unintentional islanding. This study proposes a mode transfer method for a grid-connected inverter with critical loads. The proposed method, which integrates the grid-connected and islanded mode control loops into one control block, provides an autonomous and seamless mode transfer from the current control to the voltage control. Therefore, the proposed scheme can supply a stable voltage to critical loads at mode change and during clearing time. Experimental results are provided to validate the proposed method.

Two Dimensional Transfer Modes in $CH_2$ Spin System

  • NamGoong Hyun
    • 한국자기공명학회논문지
    • /
    • 제10권1호
    • /
    • pp.59-73
    • /
    • 2006
  • Spin-lattice relaxation pathway of $CH_2$ spin system by two dimensional NOESY sequence has been discussed. Two-dimensional spectra governed by dipolar relaxation mechanism were simulated in term of transfer mode, the generalization of conventionally used magnetization mode in one dimension. The transfer matrix directly related to the Redfield relaxation matrix can be constructed by the multiplet of transfer mode. The observable relaxation transfer modes causes to variation of the off-diagonal signal intensity of phase sensitive NOESY spectra from which variable spectral density can be extracted with simple group theoretical calculation. The variation of the J-coupling peak intensity as a function of the mixing time in 2-D spectra for $n-Undecane-5-^{13}C$ and Bromoacetic $2-^{13}C$ acid has been theoretically traced.

  • PDF

Natural frequencies and mode shapes of thin-walled members with shell type cross section

  • Ohga, M.;Shigematsu, T.;Hara, T.
    • Steel and Composite Structures
    • /
    • 제2권3호
    • /
    • pp.223-236
    • /
    • 2002
  • An analytical procedure based on the transfer matrix method to estimate not only the natural frequencies but also vibration mode shapes of the thin-walled members composed of interconnected cylindrical shell panels is presented. The transfer matrix is derived from the differential equations for the cylindrical shell panels. The point matrix relating the state vectors between consecutive shell panels are used to allow the transfer procedures over the cross section of the members. As a result, the interactions between the shell panels of the cross sections of the members can be considered. Although the transfer matrix method is naturally a solution procedure for the one-dimensional problems, this method is well applied to thin-walled members by introducing the trigonometric series into the governing equations of the problem. The natural frequencies and vibration mode shapes of the thin-walled members composed of number of interconnected cylindrical shell panels are observed in this analysis. In addition, the effects of the number of shell panels on the natural frequencies and vibration mode shapes are also examined.

고용착 GMA 용접의 Arc 안정성 및 용적이행 현상에 미치는 보호gas의 영향 (Effect of Shielding gas Composition on Arc Stability and Transfer mode of High deposition GMA Welding)

  • 경규담;천홍정;이정헌;강봉용;김희진
    • Journal of Welding and Joining
    • /
    • 제15권1호
    • /
    • pp.109-115
    • /
    • 1997
  • The arc stability and the metal transfer mode of high deposition GMA welding were investigated using various compositions of shielding gas with two types of filler, ie solid wire and metal cored wire. As for a solid wire, the transfer mode changed from axial spray to rotational spray with increasing wire feed rate (welding current) and the transition current was different with the gas composition. The gas composition also affected the apparent stability of rotating arc. As for a metal cored wire, on the other hand, no transition occurred and thus spray transfer mode could be applied with the welding current over 500A (deposition rate over 300g/min). Looking for the development of high deposition GMA welding process, above results were discussed in two different ways, one is to elevate the transition current, the other is to stabilize the rotational transfer mode.

  • PDF

환승센터의 두 수단간 환승거리의 상대적 적정성 평가 (A model of a relative evaluation of the transfer distance between two modes)

  • 차동득;오재학;박완용;박선복
    • 대한교통학회지
    • /
    • 제27권1호
    • /
    • pp.35-42
    • /
    • 2009
  • 환승센터의 계획이나 개선시 제일 먼저 부딧히는 문제의 하나는 어느 수단을 얼마나 가깝게 위치시켜야 하는가 하는 것이다. 이때의 목표는 중심 수단을 이용하는 승객이 가능한 한 최단거리를 걸어서 다른 수단으로 연결될 수 있게 하는 것이다. 이 문제가 결정되고 난 후에 라야 연결 통로에 대한 서비스 수준을 향상시키는 문제를 제기할 수 있다. 물리적인 접근 거리가 너무 긴 경우 개별 통로의 서비스수준을 아무리 높여도 전체적인 환승만족도가 일정수준이상 향상되기 어렵기 때문이다. 본 연구에서는 한 수단의 도착지에서 다른 수단의 출발지까지의 전 과정 (환승패스)을 외부보도구간, 계단구간, 실내통로구간으로 나누어 이용자 설문조사를 통하여 상대적인 저항감을 구하여 합산된 환승저항을 계산하고, 이를 전반적인 환승만족도와 연결시켜 환승효용함수를 구하고 이를 토대로 환승패스의 개선 방향을 결정하는 방법을 논하였다.

3상 인버터의 계통연계 및 독립운전모드 전환 연구 (Seamless Transfer Operation Between Grid-connected and Stand-Alone Mode in the Three-phase Inverter)

  • 이우종;조현식;이학주;차한주
    • 전기학회논문지
    • /
    • 제62권2호
    • /
    • pp.201-207
    • /
    • 2013
  • This paper propose seamless transfer operation between grid-connected and stand-alone mode in the three-phase inverter for microgrid. The inverter operates grid-connected mode and stand-alone mode. Grid-connected mode is the inverter connected to grid and stand-alone mode is to deliver energy to the load from inverter at grid fault. When conversion from gird-connected to stand-alone mode, the inverter changes current control to voltage control. When grid restored, the inverter system is conversion from stand-alone to grid-connected mode. In this case, load phase and grid phase are different. Therefore, synchronization is essential. Thus Seamless transfer operation stand-alone to grid-connected mode. In this paper, propose sealmless transfer operation between grid-connceted and stand-alome mode, and this method is verified through simulation and experiment.