• Title/Summary/Keyword: Transfer l.s.c.

Search Result 203, Processing Time 0.021 seconds

A Stereochemical Aspect of Pyridoxal 5' -Phosphate Dependent Enzyme Reactions and Molecular Evolution

  • Jhee, Kwang-Hwan;Tohru, Yoshimura;Yoichi, Kurokawa;Nobuyoshi, Esaki;Kenji, Soda
    • Journal of Microbiology and Biotechnology
    • /
    • v.9 no.6
    • /
    • pp.695-703
    • /
    • 1999
  • We have studied the stereospecificities of various pyridoxal 5'-phosphate (PLP) dependent enzymes for the hydrogen transfer between the C-4' of a bound coenzyme and the C-2 of a substrate in the transamination catalyzed by the enzymes. Stereospecificities reflect the structures of enzyme active-sites, in particular the geometrical relationship between the coenzyme-substrate Schiff base and the active site base participating in an $\alpha$-hydrogen abstraction. The PLP enzymes studied so far catalyze only a si-face specific (pro-S) hydrogen transfer. This stereochemical finding suggests that the PLP enzymes have the same topological active-site structures, and that the PLP enzymes have evolved divergently from a common ancestral protein. However, we found that o-amino acid aminotransferase, branched chain L-amino acid aminotransferase, and 4-amino-4-deoxychorismate lyase, which have significant sequence homology with one another, catalyze a re-face specific (pro-R) hydrogen transfer. We also showed that PLP-dependent amino acid racemases, which have no sequence homology with any aminotransferases, catalyze a non-stereospecific hydrogen transfer: the hydrogen transfer occurs on both faces of the planar intermediate. Crystallographical studies have shown that the catalytic base is situated on the re-face of the C-4' of the bound coenzyme in o-amino acid aminotransferase and branched chain L-amino acid aminotransferase, whereas the catalytic base is situated on the si-face in other aminotransferases (such as L-aspartate aminotransferase) catalyzing the si-face hydrogen transfer. Thus, we have clarified the stereospecificities of PLP enzymes in relation with the primary structures and three-dimensional structures of the enzymes. The characteristic stereospecificities of these enzymes for the hydrogen transfer suggest the convergent evolution of PLP enzymes.

  • PDF

Comparative Study of Mass Transfer and Bubble Hydrodynamic Parameters in Bubble Column Reactor: Physical Configurations and Operating Conditions

  • Sastaravet, Prajak;Chuenchaem, Chomthisa;Thaphet, Nawaporn;Chawaloesphonsiya, Nattawin;Painmanakul, Pisut
    • Environmental Engineering Research
    • /
    • v.19 no.4
    • /
    • pp.345-354
    • /
    • 2014
  • In this paper, effects of physical configurations and operating conditions on bubble column performance were analyzed in terms of bubble hydrodynamic and mass transfer parameters. Bubble column with 3 different dimensions and 7 gas diffusers (single / multiple orifice and rigid / flexible orifice) were applied. High speed camera and image analysis program were used for analyzing the bubble hydrodynamic parameters. The local liquid-side mass transfer coefficient ($k_L$) was estimated from the volumetric mass transfer coefficient ($k_La$) and the interfacial area (a), which was deduced from the bubble diameter ($D_B$) and the terminal bubble rising velocity ($U_B$). The result showed that the values of kLa and a increased with the superficial gas velocity (Vg) and the size of bubble column. Influences of gas diffuser physical property (orifice size, thickness and orifice number) can be proven on the generated bubble size and the mass transfer performance in bubble column. Concerning the variation of $k_L$ coefficients with bubble size, 3 zones (Zone A, B and C) can be observed. For Zone A and Zone C, a good agreement between the experimental and the predicted $K_L$ coefficients was obtained (average difference of ${\pm}15%$), whereas the inaccuracy result (of ${\pm}40%$) was found in Zone B. To enhance the high $k_La$ coefficient and absorption efficiency in bubble column, it was unnecessary to generate numerous fine bubbles at high superficial gas velocity since it causes high power consumption with the great decrease of $k_L$ coefficients.

Reductive Degradation of hexachloroethane by using Iron Minerals: Kinetics studies (철 광물에 의한 헥사클로에탄의 환원적 분해: 반응 속도 연구)

  • Kim, Sung-Kuk;Park, Sang-Won
    • Journal of Soil and Groundwater Environment
    • /
    • v.9 no.2
    • /
    • pp.20-27
    • /
    • 2004
  • Kinetic characteristics dependent on several factors such as iron mineral and organic solvents were investigated. When F $e^{0}$ , FeS and Fe $S_2$ were used as mediators, minerals affecting reaction rate were in the following order : $Fe_{0}$ 0/ > FeS > $FeS_2$ when in contact $C_2$C $l_{6}$ . The more chloride substituted, the higher reaction rate were observed. The reaction rates were dependent on pH, shaking rate, temperature and specific surface area. 1, 10-phenanthroline and EDTA degradation rates were fast, indicating that they adsorbed on the surface of the iron which makes the electron transfer reaction easy. Nitrate which has $\pi$* orbital of molecular can increase electron transfer rate because it is delocalized in its entity. The reaction rates were not affected by hydroquinone. Degradation rates were much enhanced with naturally occurring kaolinite because of the surface corrosion of Fe mineral. However, The reaction rate was not affected by F $e^{2+}$ or S $O_4$$^{2-}$ presented in solution.n.

Effects of Temperatures and Basal Media on Primary Culture of the Blastomeres Derived from the Embryos at Blastula Stage in Marine Medaka Oryzias Dancena

  • Choi, Jae Hoon;Gong, Seung Pyo
    • Journal of Embryo Transfer
    • /
    • v.33 no.4
    • /
    • pp.343-348
    • /
    • 2018
  • Although the efforts to establish fish embryonic stem cells (ESCs) have been made for a long time, derivation of authentic ESCs that possess pluripotency is still difficult suggesting a need for the stepwise optimization of the methods to establish fish ESCs. Primary culture of the blastomeres from the embryos at blastula stage is a critical step for establishing continuous ESC lines. Here, we evaluated the effects of temperatures and basal media on primary culture of blastula embryo-derived blastomeres in marine medaka (Oryzias dancena). The blastomeres were isolated from the blastula embryos and cultured in various conditions designed by the combination of 4 temperatures including $28^{\circ}C$, $31^{\circ}C$, $34^{\circ}C$, and $37^{\circ}C$ and 2 basal media including Dulbecco's modified eagle's medium (DMEM) and Leibovitz's L-15 medium (L15). With the exception of a case cultured in L15 at $31^{\circ}C$, the rate of primary cell adherence reached 100% when the blastomeres were cultured over $31^{\circ}C$. The period for primary adherence was significantly shorter in the groups cultured in $34^{\circ}C$ and $37^{\circ}C$ than in the ones in $28^{\circ}C$ and $31^{\circ}C$. The proportion of subculture was significantly high in the group cultured in DMEM at $31^{\circ}C$ compared to the other groups. Collectively, we demonstrated that the culture in DMEM at $31^{\circ}C$ was effective to primary culture of the blastomeres derived from blastula embryos.

Natural Convection Heat Transfer from a Conducting Tube with Two Vertical Axial Fins (2개(個)의 수직(垂直) 평판(平板)핀을 가진 전도관(傳導管)으로 부터의 자연대류(自然對流) 열전달(熱傳達))

  • Chung, H.S.;Lee, C.J.;Kwon, S.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.3 no.4
    • /
    • pp.222-230
    • /
    • 1991
  • Conjugate heat transfer by steady laminar natural convection from a conducting tube with two vertical axial fins has been studied by a finite difference numerical procedure under basic conditions; $Ra=10_6$, Pr = 5 and $L_F=0.15$. The maximum local tube Nusselt number appears at ${\theta}=140^{\circ}$ for $L_F=0.06$, at ${\theta}=130^{\circ}$ for $L_F=0.30$ and at ${\theta}=120^{\circ}$ for $L_F=0.30$, $L_F=0.06$, respectively. The maximum mean Nusselt number shows at $L_F=0.18$ for the downward fin and at $L_F=0.12$ for the upward fin. Therefore the optimized fin length is $L_F{\approx}0.15$ under these conditions. At $L_F=0.15$, the mean Nusselt number by increasing Rayleigh number is remarkably increased for downward fin and then is slowly increased except for downward fin, it by increasing Prandtl number is apparently increased at $Pr{\leq}2$, and slightly increased at Pr>2.

  • PDF

Natural Convection Heat Transfer from a Conducting Tube with Two Axial Fins to a Surrounding Cylinder (2개의 축방향핀을 가진 전도관과 원통사이의 자연대류 열전달)

  • Chung, H.S.;Lee, S.H.;Kim, C.W.;Kwon, S.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.1 no.3
    • /
    • pp.244-251
    • /
    • 1989
  • A numerical study has been performed on the natural convection heat transfer from a conducting tube with two axial fins to a surrounding cylinder. As increasing dimensionless fin length ($L_F$), the center of flow moves to the bottom of annulus and the recirculating flow rate is decreased. The maximum local Nusselt number of conducting tube appears at ${\theta}=180^{\circ}$ for $L_F=0.0$, but at ${\theta}=130^{\circ}$ for $L_F{\geq}0.3$ and that of outer cylinder appears at ${\theta}=13^{\circ}$ for $L_F{\leq}0.6$ but at ${\theta}=33^{\circ}$ for $L_F=1.0$. The fin temperature is decreased by increasing radial distance and the temperature distribution of the downward fin is generally less than that of the upward fin. By increasing fin length, the local Nusselt number of the upward fin appears negative values for $L_F=1.0$, but appears positive values for $L_F<0.8$, and that of the downward fin appears positive values.

  • PDF

Numerical study on the thermal performance characteristics of the stack system for FCEV (연료전지 자동차용 스택 시스템의 열적 성능 특성에 관한 수치적 연구)

  • Lee, Ho-Seong;Lee, Moo-Yeon;Won, Jong-Phil
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.6
    • /
    • pp.3708-3713
    • /
    • 2015
  • The objective of this study is to numerically investigate the heat transfer rate for evaluating the thermal performances of the stack thermal system using the commercial software. In order to perform this, the cooling performances of the stack system for fuel cell electric vehicle were tested under both driving road conditions including the general driving road and uphill driving road and operating conditions with and without of the air conditioning system. The heat transfer rate of the stack radiator for the stack system was increased with the increase of the inlet air flow velocity. The heat transfer rate of the stack radiator increased by 105.3% at the coolant flow rate of 20 l/min and 221.3% at the coolant flow rate of 120 l/min with the increase of the air flow velocity from 2 m/s to 10 m/s. $9.45^{\circ}C$ of inlet coolant temperature of the stack radiator at the severe driving condition of the slope of 8% and velocity of 50 km/h showed higher 85.3% than $5.1^{\circ}C$ of inlet coolant temperature at the general driving condition of the slope of 0% and velocity of 120 km/h. In addition, as the fuel cell electric vehicle with the air conditioning system operation was driving under severe uphill driving condition, the radiator coolant temperature for a stable stack operation could be exceeded over $70^{\circ}C$.

A study on the characteristics of heat transfer and pressure drop in plate type evaporator with U-turn for automotive air conditioner (유턴 흐름을 갖는 차량공조용 플레이트형 증발기의 전열특성에 관한 연구)

  • 강정길;김종수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.4
    • /
    • pp.472-483
    • /
    • 1999
  • The evaporation heat transfer and pressure drop characteristics for HFC-l34a in flat plate type heat exchangers with enhanced beads were experimentally investigated. Three plate type evaporators with different geometric condition of U-turn area were tested. Mass fluxes were tested over the range of 83kg/$m^2$s to 166kg/$m^2$s, and heat fluxes were varied from 4㎾/$m^2$ to 12㎾/$m^2$. Evaporation temperature was 5$^{\circ}C$ with inlet qualities of 0.1 to 1.0. There was no notable difference in the heat transfer coefficient by geometric variation of U-turn area, but the third plate with cross-ribbed channel at U-turn area was better than others in the evaluation using volume goodness factor comparison. Also, the mixtures of HFC-l34a and PAG oil was tested to determine oil effects on heat transfer and pressure drop. As oil concentration was increased, heat transfer coefficient was increased by 22~48% up to the 3wt.%, but decreased by 14~22% at the 4wt.%. The pressure drop was increased by the maximum of 100% as oil concentration was increased.

  • PDF

Transfer Force Characteristics of Seedling Bed Transfer Equipment Using Pneumatic Cylinder for Automation of Plant Factory (식물공장 자동화를 위한 공압 실린더를 이용한 육묘베드 이송장치의 이송력 특성)

  • Min, Young-Bong;Park, Sang-Min;Lee, Gong-In;Kim, Dong-Ouk;Kang, Dong-Hyun;Moon, Sung-Dong
    • Journal of Biosystems Engineering
    • /
    • v.37 no.3
    • /
    • pp.155-165
    • /
    • 2012
  • This study was performed to offer the data for design of the seedling bed transfer equipment to make the automation of working process in a plant factory. The seedling bed transfer equipment pushing the seedling bed with bearing wheels on the rail for interconnecting each working process by a pneumatic cylinder was made and examined. The examined transfer force to push the seedling bed with a weight of 178.9 N by the pneumatic cylinder with length of 60 cm and section area of 5 $cm^2$ was measured by experiments. The examined transfer forces was compared with theoretical ones calculated by the theoretical formula derived from dynamic system analysis according to the number of the seedling bed and pushing speed of the pneumatic cylinder head at no load. The transfer function of the equipment with the input variable as the pushing speed $V_{h0}$(m/s) and the output variable as the transfer force f(t)(N) was represented as $F(s)=(V_{h0}/k)(s+B/M)/(s(s^2+Bs/M+1/(kM))$ where M(kg), k(m/N) and B(Ns/m) are the mass of the bed, the compression coefficient of the pneumatic cylinder and the dynamic friction coefficient between the seedling bed and the rail, respectively. The examined transfer force curves and the theoretical ones were represented similar wave forms as to use the theoretical formular to design the device for the seedling bed transfer. The condition of no vibration of the transfer force curve was $kB^2>4M$. The condition of transferring the bed by the repeatable impact and vibration force according to difference of transfer distance of the pneumatic cylinder head from that of the bed was as $Ce^{-\frac{3{\pi}D}{2\omega}}<-1$, where ${\omega}=\sqrt{\frac{1}{kM}-\frac{B^2}{4M^2}}$, $C=\{\frac{\frac{B}{2M}-\frac{1}{kB}}{\omega}\}$, $D=\frac{B}{2M}$. The examined mean peak transfer force represented 4 times of the stead state transfer force. Therefore it seemed that the transfer force of the pneumatic cylinder required for design of the push device was 4Bv where v is the pushing speed.

Condensation Heat Transfer for Pure HFC Refrigerants and a Ternary Refrigerant Mixture Inside a Horizontal Tube (HFC 순수냉매 및 3성분 혼합냉매의 수평관내 응축열전달)

  • Oh, Jong-Taek;Hihara, Eiji
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.2
    • /
    • pp.233-240
    • /
    • 2000
  • An experimental study of condensation heat transfer was performed for pure refrigerants HFC32, HFCI25, and HFC134a, and a ternary refrigerant mixture of HFC32/125/134a (23/25/52wt%). The heat transfer coefficients were measured inside a horizontal smooth tube 5.8 mm I.D. and 8.0 m long. The refrigerant temperature at inlet was 40 $^{\circ}C$, and the mass flux was varied from 150 to 400 $kg/m^2s$. As for the pure refrigerants, the heat transfer coefficient of HFC32/125/l34a decreased as the quality decreased. In addition, the heat transfer coefficient of HFC32/l25/134a was about 20 % lower than HFC 134a at a low mass flux but showed no reduction at a high mass flux. The heat transfer coefficient of ternary refrigerant mixtures was 30% lower on the average than that of the pure refrigerant.