• 제목/요약/키워드: Transfer Duct

검색결과 215건 처리시간 0.02초

채널유동에서 거친벽면이 열전달에 미치는 효과 (Effects of Rough Surfaces on Heat Transfer in Channel Flow)

  • 안수환
    • 동력기계공학회지
    • /
    • 제5권2호
    • /
    • pp.30-35
    • /
    • 2001
  • A comparison of fully developed heat transfer and friction factor characteristics has been made in rectangular ducts with one wall roughened by five different shapes. The effects of rib shape geometries and Reynolds number are examined. The rib height-to-duct hydraulic diameter, pitch-to-height ratio, and aspect ratio of channel width to height are fixed at $e/D_e=0.0476$, P/e=8, and W/H=2.33, respectively. To understand the mechanisms of the heat transfer enhancements, the measurements of the friction factors are also conducted in the smooth and rough channels. The data indicate that the triangular type rib has a substantially higher efficiency index than any other ones in the range we studied.

  • PDF

짧은 못형핀의 형상 변화에 따른 열전달 및 마찰손실 특성 (Heat transfer and friction loss characteristics of shaped short pin-fin arrays)

  • 조형희
    • 설비공학논문집
    • /
    • 제9권3호
    • /
    • pp.259-267
    • /
    • 1997
  • Average heat transfer coefficients and friction coefficients have been measured from staggered short pin-fin arrays to investigate the effect of fin shapes. Flow entering into the test section is a fully developed duct flow and the Reynolds number ranges from 5,000 to 25,000 based on fin diameter and average approaching velocity. The fin has three different shapes; uniform-diameter circular fin, two stepped-diameter circular fins. Average heat transfer rates change slightly with the fin shapes. However, friction loss(pressure loss) for the stepped-diameter fins is significantly less than that for the uniform-diameter fin. This results indicate that the stepped-diameter fin arrays in duct flow enhance heat transfer rates largely based on unit pumping power.

  • PDF

덕트 잡음 제거를 위한 다중 모델 적응 능동 소음 제어 (Multiple Model Adaptive Active Control of Noise in a Duct)

  • 남현도;정종대
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1992년도 추계학술발표회논문집
    • /
    • pp.56-59
    • /
    • 1992
  • Adaptive active attenuation of noise in a duct is considered. A duct is modelled when the acoustic feedback exists. The secondary path transfer function is estimated using multiple model approaches. An IIR structure is assumed for the control filter, and the recursive least mean squares algorithm is used to adjust the filter coefficients.

  • PDF

초임계상태 이산화탄소의 정사각 단면 직덕트 내 난류유동 및 열전달의 전산해석 (Numerical Analysis of Turbulent Carbon Dioxide Flow and Heat Transfer under Supercritical State in a Straight Duct with a Square Cross-Section)

  • 최영돈;주광섭;김용찬;김민수
    • 설비공학논문집
    • /
    • 제14권12호
    • /
    • pp.1004-1013
    • /
    • 2002
  • Turbulent carbon dioxide flows and cooling heat transfers under supercritical state in a straight duct with a square cross-section are numerically analyzed employing low Reynolds number $\kappa-\varepsilon$ model and algebraic stress model. The flow is assumed to be (quasi-incompressible. Predicted Nusselt number and friction factor are compared with the experimental data, Blasius correlation for friction factor and Dittus-Boelter correlation for Nusselt number. Computational results for the Fanning's friction factor agree well with the all Rohsenow and Choi's correlation, Liou and Hwang's experimental data and Blasius correlation. The results obtained by algebraic stress model agree more with the Liou and Hwang's experimental data, while the results obtained by low Reynolds number $\kappa-\varepsilon$ model agree more with Blasius correlation. In the computation of Nusselt number, Dittus-Boelter correlation can not exactly fit the computational results. Therefore we propose the new correlation$Nu=0.053Re^{0.73}Pr^{0.4}$for the turbulent cooling heat transfer of carbon dioxide under supercritical state.

수정점도 모델을 이용한 직사각형 덕트에서의 부력을 고려한 점탄성 유체의 열전달 특성 (Heat Transfer Behavior of Viscoelastic Fluid including buoyancy effect with Modified Temperature Dependent Viscosity Model in a Rectangular Duct)

  • 손창현;장재환
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 1999년도 춘계 학술대회논문집
    • /
    • pp.192-198
    • /
    • 1999
  • The present study proposes modified temperature-dependent non-Newtonian viscosity model and investigates flow characters and heat transfer enhancement of the viscoelastic non-Newtonian fluid in a 2:1 rectangular duct. The proposed modified temperature dependent viscosity model has non-zero value near the high temperature and high shear rate region while on the existing viscosity models have zero value. Two versions of thermal boundary conditions involving difference combination of heated walls and adiabatic walls are analyzed in this study. The combined effect of temperature dependent viscosity, buoyancy, and secondary flow caused by second normal stress difference are ail considered. The Reiner-Rivlin model is adopted as a viscoelastic fluid model to simulate the secondary flow caused by second normal stress difference. Calculated Nusselt numbers by the modified temperature-dependent viscosity model gives under prediction than the existing temperature-dependent viscosity model in the regions of thermally developed with same secondary normal stress difference coefficients with experimental results in the regions of thermally developed. The heat transfer enhancement of the viscoelastic fluid in a 2:1 rectangular duct is highly dependent on the secondary flow caused by the magnitude of second normal stress difference.

  • PDF

석유 팬 히터의 연소실 주변 열전달 특성 (Heat transfer characteristics around a circular combustion chamber of kerosene fan heater)

  • 김장권
    • 대한기계학회논문집B
    • /
    • 제22권4호
    • /
    • pp.551-561
    • /
    • 1998
  • This paper was studied to understand the characteristics of heat transfer coefficients and surface temperature distributions around a circular combustion chamber within the heat-intercept duct of kerosene fan heater. The experiment was carried out in the heat-intercept duct of kerosene fan heater attached to the blow-down-type subsonic wind tunnel with a test section of 240 mm * 240 mm * 1200 mm. The purpose of this paper was to obtain the basic data related with normal combustion for new design from conventional kerosene fan heater, and to investigate the effect of surface temperature, local and mean heat transfer coefficients versus flow-rate of convection axial fan according to the variations of heat release conditions from kerosene fan heater during normal combustion. Consequently it was found that (i) the revolution of convection axial fan during combustion had a smaller value than that of non-combustion because of the thermal resistance due to the high temperature in the heat-intercept duct, (ii) the pressure ratio P$_{2}$/P$_{1}$ had a comparatively constant value of 0.844 according to the revolution increase of turbo fan and the heating performance of kerosene fan heater had a range of 1,494 ~ 3,852 kcal/hr, (iii) the local heat transfer coefficient around a circular combustion chamber had a comparatively larger scale in the range of 315 deg. < .theta. < 45 deg. than that in the range of 90 deg. < .theta. < 270 deg. as a result of heat transfer difference between front and back of a circular combustion chamber, and (iv) the mean heat transfer coefficient around a circular combustion chamber increased linearly like a H$_{m}$=95.196Q+104.019 in condition of high heat release according to the increase of flow-rate of axial fan.n.

공기유동에 대한 고온상태의 비원형 도과내에서의 열전달 및 압력강하의 측정 (Measurement of Heat Transfer and Friction Coefficients for Flow of Air in Noncircular Ducts At High Surface Temperatures.)

  • 이동렬
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제25권3호
    • /
    • pp.552-562
    • /
    • 2001
  • Measurement of average of heat transfer and friction coefficients were obtained with air flowing through electrically heated ducts having square, rectangular(aspect ration, 5), and triangular cross section for range of surface temperature from $540^{\circ}$to $1780^{\circ}$ R and Reynolds number from 1000 to 330,000. The results indicates that the effect of heat flux on correlations of the average heat transfer and friction coefficients is similar to that obtained for circular tubes in previous investigation and was nearly eliminated by evaluating the physical properties and density of the air a film temperature halfway between the average surface and fluid bulk temperatures, With the Nusselt and Reynolds numbers on the hydraulic diameter of the ducts, the data for the noncircular ducts could be represented by the same equations obtained in the previous investigation for circular tubes. Correlation of the average difference between the surface corner and midwall temperatures for the square duct was in agreement with predicted values from a previous analysis. However, for the rectangular and triangular ducts, the measured corner temperature was greater by approximately 20 and 35 percent, respectively, than the values predicted by analysis.

  • PDF

왕복운동을 하는 사각채널에서 파형테이퍼가 열전달에 미치는 효과 (Effects of Wavy Tapers on Heat Transfer in the Reciprocating Rectangular Channel)

  • 안수환;배성택
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제27권5호
    • /
    • pp.600-608
    • /
    • 2003
  • This Paper describes a detailed experimental investigation of heat transfer in a reciprocating smooth rectangular duct having only the bottom wall heated with reference to the design of a piston for a marine propulsive diesel engine The Parametric test matrix involves Reynolds number and reciprocating radius, respectively, in the range of 1.280∼4.100, and 7∼15 cm with five different reciprocating frequency tested. namely. 1.7, 2.2, and 2.6 Hz. The effects of three different hemi-triangular wavy type tapers on the heat transfer in the reciprocating rectangular channel using the air as a working fluid were check out. The present work confirms that the Nusselt number in the channel with the triangular wavy type taper is lower than without the triangular wavy type taper.

삼각형 단면 덕트 내의 Shear-Thinning 유체에 대한 열전달 촉진에 관한 연구 (A Study on Heat Transfer Enhancement for a Shear-Thinning Fluid in Triangular Ducts)

  • 이동렬
    • 한국산학기술학회논문지
    • /
    • 제12권9호
    • /
    • pp.3808-3814
    • /
    • 2011
  • 본 연구는 열교환기의 효율적인 설계를 위하여 열교환기 내의 삼각형 단면 덕트의 비뉴톤 유체의 압력강하 및 대류 열전달률 수치해석적으로 수행하였다. 비뉴톤 유체의 구성방정식은 기존의 비뉴톤 유체 멱법칙을 보완한 수정 멱법칙 모델을 채택하였다. 덕트 내의 압력강하를 의미하는 마찰계수와 수정 레이놀즈 수의 곱은 기존 연구의 문헌치와 비교할 때 뉴톤 유체 영역과 비뉴톤 멱법칙 영역에서 각각 0.13% 및 2.85% 내에서 일치함을 보였고 비뉴톤 수정멱법칙 유체 모델의 형태를 띠는 Shear-Thinning 유체를 열교환기 내의 삼각형 단면 덕트 내에서 사용하면 뉴톤 유체보다 62%의 압력강하를 감소시켰고 12%의 대류 열전달 향상을 발생시킬 수 있었다.

덕트 버너 추가에 따른 수직형 HRSG 내 화염 복사 열전달의 영향에 관한 연구 (Effect of Flame Radiative Heat Transfer in Horizontal-Type HRSG with Duct Burner)

  • 김대희;김승진;최상민;이봉재;김진일
    • 대한기계학회논문집B
    • /
    • 제37권2호
    • /
    • pp.197-204
    • /
    • 2013
  • 본 연구에서는 덕트 버너를 추가적으로 사용하는 수직형 배열회수 보일러(HRSG)에서 발생하게 되는 화염에 의한 전열면으로의 화염 복사 열전달에 의한 영향을 살펴보기 위한 해석 기법을 마련하였다. 덕트 버너 화염과 전열면은 가상의 평면으로 가정하였고, 화염 온도, 면적 및 방사율 입력정보는 간략화 하였다. 덕트버너 설치 위치 및 연료를 달리한 3 가지 해석 case 가 고려되었으며 계산된 화염 복사 열전달률과 열유속은 삼원자 가스 복사 및 대류 열전달과 비교되었다. 모든 해석 case 에서 삼원자 가스복사 열전달에 의한 영향은 미미하였고, 전열면에서 대류 열전달 대비 화염 복사 열전달률은 8~41%인 것으로 나타났다. 이 연구에서 얻은 중요한 사실은 화염 복사가 집중되는 전열면의 중앙부분에서 국부적인 열유속은 화염 복사에 의해 완전히 지배된다는 것이다.