노후하수관 워터젯분사장치의 분사조건에 따른 열전달특성에 관한 연구 (A Study on the Heat Transfer Characteristics of Water-Jet-Impingement)

  • 노홍구;임경빈;노종호;이영기;이성철;고준빈
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.1190-1194
    • /
    • 2008
  • The study aims to analyzed and identify the heat transfer characteristics of water-jet-impingement with use of 3-D numerical-analysis in order to design the old water duct. The temperature comparison processes were done with various duct flows. In addition, the optimal conditions of water-jet-impingement were proposed as jet-pressure, the temperature on the beat plane, and so on.

  • PDF

원형 실린더 후류 영역의 국소 열전달 특성 (Local Heat Transfer Characteristics in the Wake Region of a Circular Cylinder)

  • 장병훈
    • 에너지공학
    • /
    • 제14권1호
    • /
    • pp.30-36
    • /
    • 2005
  • 본 논문에서는 실린더 후류 영역의 열전달 특성에 대한 실험결과를 보고하였다. 정체점(θ=0°)로부터 실린더 뒷면(θ=180°)까지 국소 열전달을 측정하였으며, 축 방향에 대한 누셀트 수의 변화도 조사하였다. 덕트 중앙에 비하여 덕트 벽면근처의 후류영역 열전달계수는 58% 정도 높게 측정되었으며, 종횡비와 열전달 경계조건의 영향도 조사하였다.

기울어진 덕트 내 헬리컬 코일의 자연대류 열전달 (Natural Convection Heat Transfer of an Inclined Helical Coil in a Duct)

  • 박주현;정범진
    • 에너지공학
    • /
    • 제23권2호
    • /
    • pp.13-20
    • /
    • 2014
  • 헬리컬 코일이 덕트 내부에 있을 때, 기울기에 따른 자연대류 열전달을 실험적으로 측정하였다. 고부력 조건을 구현하기 위하여 유사성에 기초하여 열전달 실험을 대신하여 물질전달 실험을 수행하였다. RaD 수 $4.55{\times}10^6$에서, 턴(Turn) 수를 1~10, P/D를 1.3~5, 헬리컬 코일의 기울기를 $0^{\circ}{\sim}90^{\circ}$까지 변화시켰다. 헬리컬 코일의 턴 수가 1일 때, 측정된 $Nu_D$ 수는 McAdams의 수평관 자연대류 열전달 상관식과 거의 일치하였다. 기울어진 덕트 내 헬리컬 코일의 자연대류 열전달은 피치, 턴 수, 덕트 높이에 따라 복합적으로 변화하였고 이는 속도 효과, 굴뚝 효과, 예열 효과로 분석되었다. 본 연구의 결과는 Compact heat exchanger에서의 자연대류 열전달에 대한 현상학적 분석에 기여한다.

열교환기 내부 유로 꺾임각 변화에 따른 국소 열/물질전달 특성 고찰 (Effects of Corrugation Angle on Local Heat/mass Transfer in Wavy Duct.)

  • 장인혁;황상동;조형희
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.97-102
    • /
    • 2003
  • An experimental study is conducted to investigate the effects of duct corrugation angle on heat/mass transfer characteristics in wavy ducts by using a naphthalene sublimation technique. The corrugation angles of the wavy ducts are $145^{\circ}$ , $130^{\circ}$ and $115^{\circ}$ . and the Reynolds numbers based on the duct hydraulic diameter vary from 300 to 3,000. At the low $Re(Re{\leq}1000)$, high heat/mass transfer regions are formed by the secondary vortex flows called Taylor-Gortler vortices on both pressure-side and suction-side walls. At the high $Re(Re{\geq}1000)$, the effects of these secondary flows are vanished. As corrugation angle decreases, the local peak Sh induced by Taylor-Gertler vortices are increased and average Sh also enhanced. More pumping power (pressure loss) is required with the smaller corrugation angle due to the stronger secondary vortex flows.

  • PDF

정사각덕트의 코너부에서 이차유동 특성 (A Characteristics of a Secondary flow in a Corner Section of Square Duct)

  • 정정무;김지환;유영태
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.753-758
    • /
    • 2000
  • Heat engine and fluid machinery in the plant have to linked with various ducts network and the corresponding design have to be concerned about effectiveness and stability of system of plant. To optimum control and design system concerning stability, economization, operating effectiveness we have to exact analysis flow properties of a duct applying to fluid machinery, heat exchanger, cooling machine, air conditioning equipment. therefore, it is necessary to research the duct, heat transfer equipment, for increasing overall effectiveness of air conditioning system by suggesting basic data of the duct resulting from organic research. So we can contribute to technical development of the duct. In case of speeding up the flow rate of the duct, lots of wave velocity components are occurred the value of boundary layer resulting from developing the boundary layer at both walls of duct.

  • PDF

Duct 잡음 제거를 위한 적응 능동 소음 제거법 (Adaptive active control for duct noise attenuation)

  • 남현도;이철희;정찬수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 A
    • /
    • pp.299-301
    • /
    • 1992
  • The adaptive active noise control algorithm for duct noise attenuation is considered. A new algorithm to estimate the secondary path transfer function using multiple models is presented. The computational burden of the proposed algorithm is much smaller than the existing methods, so it could be applied to the multi-channel cases. Computer simulations were done to show the effectiveness of the proposed algorithm in a duct case.

  • PDF

복합각도 요철을 가지는 사각 덕트 내의 열전달 및 압력강하 특성 (Characteristics of Heat/Mass Transfer and Pressure Drop in a Square Duct with Compound-Angled Rib Turbulaters)

  • 최청;이동호;조형희
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2001년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.325-333
    • /
    • 2001
  • The present study investigates convective heat/mass transfer and flow characteristics inside the cooling passage of the gas-turbine blades. It is important to increase not only the heat transfer rates but also the uniformity of heat transfer in the cooling passage. The square duct has compound-angled ribs with $60^{\circ},\;70^{\circ}$ and $90^{\circ}$ attack angles, which are installed on the test plate surfaces. a naphthalene sublimation technique is employed to determine the detailed local heat transfer coefficients using the heat and mass transfer analogy. The ribs disturb the main flow resulting in the recirculation and secondary flows near the ribbed wall and the vertices near the side-wall. The local heat transfer and the secondary flow in the duct are changed largely according to the rib orientation. Therefore, geometry and arrangement of the ribs are important fur the advantageous cooling performance. The angled ribs increase the heat transfer discrepancy between the wall and center regions because of the interaction of the secondary flows. The average heat/mass transfer coefficient and pressure drop of the ribs with the $60^{\circ}$ $-90^{\circ}$ compound-angle are higher than those with the $60^{\circ}$ attack angle. Also, the thermal efficiency of the compound-angled rib is higher than that with the $60^{\circ}$ attack angle. The uniformity of heat/mass transfer coefficient on the cross ribs may is higher than that on the parallel ribs array.

  • PDF

안내덕트 내부 난류유동구조에 따른 열전달 특성변화 수치해석 (Numerical Study on Heat Transfer Characteristics of Turbulent Flow in Transition Duct)

  • 유근종;최훈기;최기림
    • 대한기계학회논문집B
    • /
    • 제35권9호
    • /
    • pp.923-932
    • /
    • 2011
  • 본 연구에서는 복합화력발전소 가스터빈 출구가스 안내덕트 내부의 가스유동장이 배열회수보일러 전열기구에 미치는 영향을 CFD기법을 이용하여 분석하였다. 안내덕트 내부 난류흐름의 경우, 유속의 편차가 크고 선회 효과 및 상승류 현상이 심한 특징을 가지고 있음으로 이와 같은 유동의 수치해석을 위해 2개 방정식 난류점성 모델 중 RNG k-${\epsilon}$ 모델을 사용하였으며 유동장의 영향을 가장 많이 받는 배열 회수보일러 최종과열기관의 열전달특성변화를 파악하기 위하여 NTU 방식을 이용한 수치해석결과와, 산업계에서 적용하는 설계기법에 의한 결과를 비교하였다.

사각덕트 내에서 원형 실린더 주위의 강제대류 열전달에 대한 실험과 수치계산에 관한 연구 (Study on the Experiment and Numerical Computation of Forced Convection Heat Transfer around Circular Cylinder in a Rectangular Duct)

  • 윤영환;김경환
    • 설비공학논문집
    • /
    • 제16권5호
    • /
    • pp.490-498
    • /
    • 2004
  • This paper measures the forced convective heat transfer from heated cylinder to air flow in a rectangular duct at Re$_{D}$ =2,337, 4,589, 6,621 and 7,944 through experiments. And the heat transfer is computed by 3-D numerical computation in which various turbulent models are applied. It is shown through the comparison of experimental and computed data that numerical computation with standard k-$\varepsilon$ model predicts the experimental data most accurately. Furthermore, the correlation from the computed heat transfer is almost similar to that from the experiment when Re$_{D}$ is greater than 4,589. In addition, the correlation of McAdams is the closest to that from experimental data among various correlations from literature in the range of Reynolds number.ber.

직사각형 덕트에서 전단율에 의존적인 열전도율을 갖는 비뉴턴 유체의 열전달 향사아에 관한 수치적 연구 (Numerical heat transfer in a rectangular duct with a non-newtonian fluid with shear-rate dependent thermal conductivity)

  • 김병석;신세현;손창현
    • 대한기계학회논문집B
    • /
    • 제21권6호
    • /
    • pp.773-778
    • /
    • 1997
  • The present study investigates the effect of the shear rate-dependent thermal conductivity of non-newtonian fluids on the heat transfer enhancement in a 2:1 rectangular duct flow. An axially-constant heat flux and a peripherally-constant temperature boundary conditions(H1) was adopted for a top-wall-heated configuration. The present numerical results of Nusselt numbers for SRDC(Separan) show heat transfer enhancement over those of SRIC. The Nusselt numbers increased linearly as Reynolds numbers increased. The heat transfer enhancement is due to an increased thermal conductivity near the wall, which is attributed to the shear rate-dependence.