• Title/Summary/Keyword: Transcutaneous measurement

Search Result 20, Processing Time 0.028 seconds

Effects of Transcutaneous Electrical Nerve Stimulation on Delayed Onset Muscle Soreness (지연성 근육통(delayed onset muscle soreness)에 대한 경피선경자극(transcutaneous electrical nerve stimulation)의 효과)

  • Nam, Ki-Seok;Lee, Yun-Ju;Kim, Jong-Man
    • Physical Therapy Korea
    • /
    • v.4 no.3
    • /
    • pp.70-83
    • /
    • 1997
  • The purpose of this study was to determine the effects of transcutaneous electrical nerve stimulation(TENS) on delayed onset muscle soreness(DOMS). Twenty males performed eccentric exercise of the elbow flexor. Subjects were randomly assigned to one of three groups: 1) a group ($n_1$=7) that received low frequency TENS (7 Hz), 2) a group ($n_2$=7) that received high frequency TENS (500 Hz), 3) a control group ($n_3$=6) that received no treatment. DOMS was induced in a standardised fashion in the non-dominant elbow flexor of all subjects by repeated eccentric exercise. Treatments were applied immediately following exercise and again at 24 hours and at 48 hours after. Subjects attended on three consecutive days for treatment and measurement of elbow flexion, extension and resting angle(universal goniometer), and pain(Visual Analogue Scale; VAS) on a daily basis. Measurements were taken after treatment. Analysis of results using repeated measures analysis of variance(ANOVA) and post hoc tests were as follows: 1) there were between groups differences in pain value at 48 hours after (p<0.05), 2) one-way ANOVA with repeated measurement for pain, resting angle, flexion angle and extension angle revealed significant differences within low frequency TENS group, 3) one-way ANOVA with repeated measurement for flexion angle revealed significant difference within high frequency TENS group.

  • PDF

Development of a transcutaneous system for implantable bio-signal measurement (생체신호계측을 위한 체내 이식형 무선송수신 시스템 개발)

  • Lee, Seung-Ha
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.23-28
    • /
    • 2008
  • In order to measure bio-signals, it is desirable to build a fully implantable system which connects directly to neural pathways or body tissue. A design scheme for fully implementable measurement system is proposed in this paper. Consisting of an implanted module and an external system, the proposed scheme delivers power and data between the two modules. The external module sends power via inductive link using a simple H-bridge type oscillator. Also, the implanted module sends measured data to the external system utilizing R/F communication technique at a frequency of ISM band. A stable communication and operation is achieved as the two types of channels are separated. Implemented in a compact size enough to be implanted in human body, the system exhibits good performance in experimental studies.

Measurement and Control of the Resonance Frequency for the Transcutaneous Energy Transmission System (TET) Using the Phase Locked Loop Circuit (PLL) (PLL을 이용한 무선 전력전송 장치의 공진 주파수의 계측 및 주파수 제어)

  • Choi, S.W.;Shim, E.B.
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1613-1616
    • /
    • 2008
  • A Transcutaneous Energy Transmission System (TET) has been developed for the wireless energy transmission with two magnetically coupled coils. A resonance circuit is used to raise the induced voltage and current of the secondary coil. Its resonance frequency depends on the internal resistance of circuit and the transferred energy. Because the transferred energy usually changes in wide range, the output voltage is unstable and the energy transferring efficiency decrease. A push-pull class E amplifier is usedto generate high frequency AC voltage. To maintain proper resonance frequency, the voltage output of the amplifier was continuously monitored and adjusted to the optimized resonance frequency. Because of its high frequency (370 kHz), a phase lockedloop circuit and a comparator are used to monitor the output waveform. The results of experimentaldata show that the PLL circuit can increase the transmission efficiency and stabilize the output voltage of TET.

  • PDF

The Effect of Transcutaneous Electrical Nerve Stimulation on Sympathetic Tone (경피신경 전기자극법이 교감신경 긴장성에 미치는 영향)

  • An, Soo-Gyung;Yoo, Hwan-Suk;Lee, Ji-Hyun;Kim, Young-Rok
    • Physical Therapy Korea
    • /
    • v.3 no.2
    • /
    • pp.77-83
    • /
    • 1996
  • The purpose of this study was to determine the effect of transcutaneous electrical nerve stimulation(TENS) on sympathetic tone in healthy subjects. Stimulation in the conventional and burst modes was applied to the skin of the forearm overlying the median nerve. TENS was applied for 20 minutes at an intensity sufficient to produce a perceptible though not uncomfortable sensation and no muscle contracion of the forearm musculature. The change in sympathetic tone was measured with skin temperature. Skin temperature was measured at the index finger and on the volar surface of the forearm in the stimulated limb. The conventional and burst modes did not change the skin temperature at any of the two measurement sites. We conclude that TENS, as applied in this study, does not influence sympathetic tone. Further research is needed to assess the sympathetic effects of TENS on patient groups, long term treatment and other modalities.

  • PDF

Assessment of Neonatal Hyperbilirubinemia Using a Transcutas Bilirubinometry (신생아에 있어 TcB[transcutaneous bilirubinometry]를 이용한 고빌리루빈혈증의 사정)

  • 안영미;김미란;이상미;전용훈
    • Journal of Korean Academy of Nursing
    • /
    • v.33 no.1
    • /
    • pp.51-59
    • /
    • 2003
  • Purpose: The purpose of the study is to investigate the relationship between total serum bilirubin(TSB) and transcutaneous bilirubinometry(TcB) in neonates with jaundice. Method: TcB from various sites(forehead, sternum, abdomen, buttock, hand, dorsalis-pedia) was measured using a JM-102 in a total of 102 neonate, 42 female and 60 male, with the mean 37.5 gestational week and the mean 2,903 gram of birth weight, as well as TSB from capillary punctures. Result: The mean bilirubin was 11.73 in serum, 20.55 on the forehead, 17.23 on the sternum, 16.19 on the abdomen, 18.22 on the buttock, 15.83 on the hand and 15.49 on the dorsalis-pedia. The relationship between TSB and TcBs were formulated by simple regression with 0.406 < r < 0.668(p < .000). A higher relationship was revealed between TSB and TCB at the forehead in infants of full-term, ABO incompatibility, and Hb greater than 16 mg/dl(r =0.725, 0.790, and 0.717, retrospectively). Phototherapy altered the measurement of TcB per site. Conclusion: TcB on the forehead is a reliable, noninvasive and convenient measurement of TSB in normal infants(Institutions need to establish quantitative equations representing the specific relationship between TSB and TCB according to the hemodynamic problems of infants such as ABO incompatibility, or low Hb).

THE MEASUREMENT OF THE EFFECT IN THE FIELD OF ORAL REGION ESPECIALLY UPPER AND LOWER ANTEROR REGION USING THE TRANSCUTANEOUS ELECTRICAL NERVE STIMULATION (Transcutaneous electrical nerve stimulation이론의 상하악 전치부 영역별 적용효과에 대한 측정)

  • Cho, Sung-Am;Yun, Min-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.3
    • /
    • pp.431-437
    • /
    • 1996
  • To evaluate the clinical usefulness of TENS theory, 12 dental studensts of KyungPook National University and 18 prosthodontic patients were applied by 3M DENTAL ELECTRONIC ANESTHESIA and the follwing results were obtained: 1. Using the TENS theory to 12students, and EPT test was conducted and 6 students among total 12 students showed the anesthetic effects to the pain(p<0.05). 2. 15 prosthetically preparated patients show the anesthetic effects to the pain among total 18 patients.

  • PDF

Effects of Transcutaneous Electrical Nerve Stimulation and Microcurrent Electrical Neuromuscular Stimulation on Delayed Onset Muscle Soreness (지연성 근육통에 대한 경피신경 전기자극과 미세전류 신경근 자극의 효과 비교)

  • Jung, Young-Jong;Gho, Su-Jeong;You, Hye-Young;Jung, Do-Young
    • Physical Therapy Korea
    • /
    • v.7 no.2
    • /
    • pp.76-87
    • /
    • 2000
  • Delayed onset muscle soreness (DOMS) is a common problem that can interfere with rehabilitation as well as activities of daily living. The purpose of this study was to determine the effects of both transcutaneous electrical nerve stimulation (TENS) and microcurrent electrical neuromuscular stimulation (MENS) on DOMS, Twenty-seven untrained and male volunteer subjects were randomly assigned to one of three treatment groups: 1) a group that received TENS (7 Hz), 2) MENS (60 ${\mu}A$, .3 pps) or 3) a control group that received no treatment. Subjects performed repeated eccentric exercise of the non-dominant forearm flexor muscle with submaximal intensity by the simply designed eccentric exercise devices. Treatments were applied after 24 hours and 48 hours. Subjects attended on two consecutive days for treatment and measurement of elbow flexion, extension, resting angle (universal goniometer), and pain (visual analogue scale: VAS) on a daily basis. Measurements were taken after treatment. Analysis of results were as follows; 1) There were no significant differences between TENS and MENS by one-way repeated ANOVA, 2) The t-test for pain, resting, flexion and extension angle revealed significant differences within TENS group, 3) The t-test for resting angle revealed significant differences within MENS group.

  • PDF

Basic Research of Non-Invasive Optical Transcutaneous pCo2 Gas Sensor & Analytic Equipment (비침습적 방법에 의한 광학식 Transcutaneous pCo2 가스센서 및 분석장치 개발을 위한 기초연구)

  • Kim, Do-Eok;Lee, Seung-Ha;Cho, Eun-Jong;Kang, Shin-Won
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.4
    • /
    • pp.258-263
    • /
    • 2004
  • In this study, we carried out a basic study for the development of optical transcutaneous $pCO_{2}$ gas sensor and analyzer using non-invasive method. The basic principle of $pCO_{2}$ measurement is adapted Beer lambert's law and embodied the system using NDIR method. This measuring system was composed of a IR lamp, a optical filter, a optical reaction chamber, pyroelectric sensor and a signal process. We measured $EtCO_{2}'s$ concentration in basis step instead of $pCO_{2}$ gas that can collect by inflicting heat in outer skin. We minimize the size of optical reaction chamber which takes up the largest volume, to make the portable sensor. We made optical reaction chamber in Si wafer using MEMS technology and the optical reaction chamber was shortened to 2 mm and we carried out an experiment. When we injected the $EtCO_{2}$ to the inside of the optical reaction chamber, we could confirm change of 4.6 mV. The system response time was within 2 second that is fairly fast.

Effect of Conventional Transcutaneous Electrical Nerve Stimulation on Plasma $\beta-endorphin$ Level (고빈도-저강도 경피신경전기자극이 혈장 $\beta-endorphin$ 농도에 미치는 영향)

  • Lee Jae-Hyoung;Pack Chun-Seo;Kang Jung-Koo
    • The Journal of Korean Physical Therapy
    • /
    • v.5 no.1
    • /
    • pp.39-46
    • /
    • 1993
  • The purpose of this study was to examine the effect and $\beta-endorphin$ level as conventional transcutaneous electrical nerve stimulation (TENS) application on acupuncture paints. Twelve healthy adult male volunteers were participated in this study. The subjects were assigned to TENS group (n=6) and naloxone group (n=6). The LI 3 and M 10 meridian points of dominant arm were stimulated comfortably with 100 pps, $75{\mu}s$ conventional TENS for 30 minutes. Experimental pain threshold measurement and plasma $\beta-endorphin$ level were detected before and after conventional TENS application. Experimental pain threshold increased significantly (p<.01) but plasma $\beta-endorphin$ level was not change in TENS group. Experimental pain threshold increased significantly (p<.01) but plasma $\beta-endorphin$ level was not change in naloxone group. In this study, the conventional TENS induced analgesic effect, and plama $\beta-endorphin$ level was not increase concomitantly with analgesia. These results suggest that the $\beta-endorphin$ did not involved in conventional TENS analgesia.

  • PDF

Usefulness of the transcutaneous bilirubinometer during phototherapy in neonatal jaundice (신생아 황달에서 광선치료 동안에 경피적 빌리루빈 측정기의 유용성)

  • Lee, Yung Kwun;Kim, Kyung Ah;Ko, Sun Young;Lee, Yeon Kyung;Shin, Son Moon
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.12
    • /
    • pp.1296-1300
    • /
    • 2006
  • Purpose : We studied the usefulness of transcutaneous bilirubinometers in follow-up of bilirubin levels during phototherapy in neonatal jaundice patients. Methods : Transcutaneous bilirubin (TcB) was measured twice per day on 90 neonatal jaundice patients without risk factors of jaundice by transcutaneous bilirubinometer JM-103(Minolta/Hill-Rom Air-shields, Japan). TcB was measured simultaneously on the patched-forehead (TcB-PF), patchedchest(TcB-PC), unpatched-forehead (TcB-UF) and unpatched-chest (TcB-UC) of infants with neonatal jaundice. Plasma bilirubin (PB) was measured by American Optical bilirubinometer (American Optical Co, Buffalo, USA) within 30 minutes after transcutaneous bilirubinometer measurement. Each TcB was compared with PB. Results : In the study group, the mean gestational age was $38.6{\pm}1.3wk$, the mean birthweight was $3,207.0{\pm}472.1g$, the mean age at start of phototherapy was $4.9{\pm}0.9days$ and the mean duration of phototherapy was $1.3{\pm}0.6days$. The correlation between TcB and PB level was observed. The correlation between TcB of the patched part (TcB-PF, TcB-PC) and PB was more significant than that of the unpatched part (TcB-UF, TcB-UC) and PB. The most significant correlation was between PB and TcB-PC. Conclusion : TcB was useful in the follow-up of jaundice during phototherapy as well the screening of jaundice in neonatal jaundice patients. TcB of patched-chest area was the most reliable site in transcutaneous bilirubinometer examination in neonatal jaundice patients.