• 제목/요약/키워드: Transcutaneous Electrical Nerve Stimulation

검색결과 143건 처리시간 0.022초

침형 경피신경 전기자극법과 전통적인 경피신경 전기자극법의 교차효과 비교 (The Comparison of the Acupuncture-Like Transcutaneous Electrical Nerve Stimulation and Conventional Transcutaneous Electrical Nerve Stimulation in Crossover Effect)

  • 권수현;배은영;신영주;이재호
    • 한국전문물리치료학회지
    • /
    • 제3권2호
    • /
    • pp.29-35
    • /
    • 1996
  • The purpose of this study was to compare acupuncture-like transcutaneous electrical nerve stimulation(ALTENS) with conventional transcutaneous electrical nerve stimulation(C-TENS) for crossover effect in healthy subjects. Forty subjects recieved ALTENS(20 persons), C-TENS(20 persons) to one upper extremity. Each technic was applied to the motor point of the wrist extensor muscle group for twenty-minutes. With the subject placed in supine the technics were applied at 80 Hz, 2-10 mA(ALTENS) and 10 Hz, 4-12 mA(C-TENS). Results revealed: (1) a significant difference between the pretreatment and posttreatment in each group(p<.05) (2) no significant difference between ALTENS and C-TENS(p>.05). In conclusion, there was no difference between ALTENS and C-TENS for crossover effect.

  • PDF

경피신경전기자극과 초음파가 전기생리학적 반응에 미치는 영향 (Effects on Electrophysiologic Responses to the Transcutaneous Electrical Nerve Stimulation and Ultra Sound)

  • 백수정;이미애;김진상;최진호
    • The Journal of Korean Physical Therapy
    • /
    • 제12권1호
    • /
    • pp.49-56
    • /
    • 2000
  • The purpose of this study was to investigate the influnce of afferent stimuli, transcutaneous electrical nerve stimulation and ultra sound, on the electrdiagnostic study of normal subjects. Electrodiagnostic study was performed before and after the application of afferent stimulation of the right popliteal fossa on 18 healthy female volunteers. After the transcutaneous electrical nerve stimulation, there is no significantly change of latencies and amplitudes of SEP, H-reflex, peroneal nerve F-wave, and sensory nerve conduction. After the ultra sound, there is no significantly change of latencies and amplitudes of SEP, H-reflex, peroneal nerve F-wave, and sensory nerve conduction. Tibial nope F-wave and motor nerve shows prolonged latency after TENS and US (p<0.01). Ultrasound may have a similar mechanism of action compared to transcutaneous electrical nerve stimulation by having localized inhibitory effects of the peripheral nerve. However, further investigation is needed to assess their mechanism of action and the precise relevance of stimulation modality.

  • PDF

미주신경 자극을 위한 새로운 방법 : 비침습적 TENS 적용에 대한 미주신경 자극의 치료적 효과 (New Methods of Vagus Nerve Stimulation : Therapeutic Effects of Non-Invasive Vagus Nerve Stimulation by TENS Application)

  • 권해연;문현주
    • 대한통합의학회지
    • /
    • 제4권4호
    • /
    • pp.77-82
    • /
    • 2016
  • Purpose: The purpose of this study was to investigate the therapeutic effect of non-invasive vagus nerve stimulation by transcutaneous electrical nerve stimulation application on the autonomic nervous system of human body. Methods: Participants were seventeen healthy adults. Standard deviation of all normal N-N intervals(SDNN), root mean square of successive differences(RMSSD), low frequency(LF), high frequency(HF) were compared in pre and post Mean values after intervention. Data were analyzed in Wilcoxon's signed-ranks test. Results: The results of this study is that sistolic blood pressure and pulse rate decreased mean value after non-invasive vagus nerve stimulation by transcutaneous electrical nerve stimulation. High frequency, low frequency, SDNN, RMSSD increased mean value in heart rate variability after intervention. But that is not significant except for SDNN. Conclusion: Non-invasive vagus stimulation by transcutaneous electrical nerve stimulation effect on parasympathetic nerve stimulation, and then it might be effective method for autonomic nerve balance control.

Carrageenan으로 유도된 염증성 근통증 흰쥐 모델에서 경피신경전기자극과 냉치료에 의한 비복근의 cyclooxygenase-2의 감소 (Reduction of muscle cyclooxygenase-2 with transcutaneous electrical nerve stimulation and cold therapy in rats of carrageenan-induced inflammatory muscle pain)

  • 백윤웅;채윤원
    • 대한물리치료과학회지
    • /
    • 제9권1호
    • /
    • pp.89-94
    • /
    • 2002
  • Prostaglandins are generated through two isoforms of the enzyme cyclooxygenase, constitutively expressed cyclooxygenase(COX)-1 and COX-2, which is induced at sites of inflammation. Inhibition of COX-2 is desirable as this may avoid side effects seen with NSAIDs. We examined the effects of transcutaneous electrical nerve stimulation and cold therapy on the levels of muscle cycloooxygenase-2 mRNA in rats of carrageenan-induced inflammatory. The method of behavioral assessment were paw withdrawal latency(PWL) and tail flick test(TFT). The COX-2 mRNA levels were quantified by reverse transcription-polymerase chain reaction (RT-PCR). Following the transcutaneous electrical nerve stimulation and cold therapy, PWL and TFT were increased and COX-2 mRNA expression in gastrocnemius muscles were decreased. These results suggest that a transcutaneous electrical nerve stimulation and cold therapy were good therapy for a muscle pain.

  • PDF

Basic Understanding of Transcutaneous Electrical Nerve Stimulation

  • Jung, Jae-Kwang;Byun, Jin-Seok;Choi, Jae-Kap
    • Journal of Oral Medicine and Pain
    • /
    • 제41권4호
    • /
    • pp.145-154
    • /
    • 2016
  • Transcutaneous electrical nerve stimulation (TENS) is one of the representative physiotherapical modalities used for the treatment of various musculoskeletal disorders by the application of electrical stimuli. In dental practice, it has long been used in the treatment of acute and chronic orofacial pain conditions including temporomandibular disorders. TENS is the delivery of therapeutic electrical stimuli with a variety of electrical intensity, frequency and duration to stimulate peripheral nerve through surface electrodes with various form and placement. While controversy still remains over the clinical effectiveness and application of TENS, basic understanding of its electrical properties and the expected biological reactions is important to increase the therapeutic effect and decrease the risk of possible side effects. This review, therefore, focuses on basic understanding of TENS including its underlying mechanisms and stimulation parameters.

경피신경전기자극이 지연성근육통의 교감신경활동에 미치는 영향 (The Effects of Transcutaneous Electrical Nerve Stimulation on Sympathetic Nerve Activity in Delayed Onset Muscle Soreness)

  • 박장성
    • The Journal of Korean Physical Therapy
    • /
    • 제14권1호
    • /
    • pp.109-115
    • /
    • 2002
  • This study conducts eccentric exercise ti non-dominant elbow flexor of 20 persons in order to examine the effects of transcutaneous electric nerve stimulation on sympathetic nerve activity in delayed onset muscle soreness, induces delayed onset muscle soreness, divides them into 10 persons respectively as experimental and control groups. And a stimulation for 2 min. with 100 pps is given to elbow flexor after repeated three times of 10 minutes rest, temperature, blood pressure and pulse are measured and as a result of two-way ANOVA, change of temperature didn't show a significant difference according to the elapse of times(p>0.05) and systolic pressure and pulses in showed a significant difference between experimental and control groups(p<0.05). These results suggest that transcutaneous electrical nerve stimulation has a direct or indirect influence on sympathetic nerve activity in delayed onset muscle soreness under a restricted condition of electrical stimulation.

  • PDF

Effects of Transcutaneous Electrical Nerve Stimulation(TENS), Self-Stretching and Functional Massage on the Muscle Fatigue by Maximum Muscular Strength

  • Yoon, Jung Gyu;Ryu, Je Ju;Roh, Hye Won;Yang, Hyun Ah;Lee, Sang Bin
    • 국제물리치료학회지
    • /
    • 제3권2호
    • /
    • pp.422-428
    • /
    • 2012
  • The present study purposed to examine the effects of transcutaneous electrical nerve stimulation, self-stretching and functional massage on the recovery of muscle contraction force for muscle fatigue caused by sustained isotonic contraction. The subjects of this study were 45 healthy students. They were divided into transcutaneous electrical nerve stimulation group(n=15), self-stretching group(n=15) and functional massage group(n=15), and using Primus RS. We observed the pattern of changes in maximal voluntary isometric contraction force(MVIC) after causing muscle fatigue in quadriceps femoris muscle through sustained isotonic contraction. Maximal voluntary isometric contraction force(MVIC) were greatly increased after transcutaneous electrical nerve stimulation, self-stretching and functional massage. In the comparison of recovery rate of muscle contraction force for muscle fatigue caused by sustained isotonic contraction among the treatment groups, it did not show any significant differences. However, it showed that each treatment may be effective in recovery of muscle fatigue caused by sustained isotonic contraction.

Transcutaneous Electrical Nerve Stimulation System for Treating Tinnitus based on the Cortex-M4 Microcontroller

  • Lee, Jaeung;Yeom, Hojun
    • International journal of advanced smart convergence
    • /
    • 제5권4호
    • /
    • pp.10-14
    • /
    • 2016
  • Among the methods of treating tinnitus, the transcutaneous clectrical nerve stimulation (TENS) method of treating by electrical stimulation is common. However, there is a problem that surgical operation is required to stimulate the vagus nerve (VN) main trunk near most of the bronchus. Alternatively, we found that the same effect could be achieved by electrically stimulating the vagus nerve VN branch (Arnold's nerve) distributed in the outer ear. The TENS system for stimulation of vagus nerve has been developed, but it has not been able to implement to stimulate as a parameter optimized for the patient by simultaneously playing the sound of eliminating the tinnitus frequency. Therefore, in this paper, it is important to develop a safe and practical TENS device for tinnitus treatment based on a 32-bit microprocessor that simultaneously applies non-invasive and notched sounds and to develop optimal treatment methods for treating tinnitus.

휴대폰 내장을 위한 경피신경 자극치료기의 설계 및 구현 (Design and Implementation of Transcutaneous Electrical Nerve Stimulation System for the Integration with Mobile Phone)

  • 우상효;윤기원;이정현;박희준;원철호;조진호
    • 한국멀티미디어학회논문지
    • /
    • 제9권3호
    • /
    • pp.360-368
    • /
    • 2006
  • 최근 휴대폰의 성능이 향상되면서 다양한 부가기능을 내장한 멀티미디어 폰이 등장했다. 특히 웰빙에 대한 관심이 증가하여 바이오 기능을 휴대폰에 내장 하기위한 다양한 시도가 있어 왔다. 여러 가지 바이오 기능 중 경피 신경 전기치료기는 혈액 순환의 개선과 통증 억제의 기능이 있으므로 이를 휴대폰에 내장시키면 언제 어디서나 쉽게 전기 자극을 통해 혈액 순환을 개선하고 통증 억제를 할 수 있는 장점이 있다. 경피 신경 전기치료기를 휴대폰에 내장시키기 위해서는 소형 및 저전력의 자극모듈이 필요하며, 모듈이 오동작할 경우에도 사용자의 안전을 보장할 수 있어야 한다. 본 논문에서는 소형의 승압기를 이용하여 휴대폰에 내장가능 한 전기자극기를 설계 및 제작하였으며, 사용자의 안전을 위해 자극기의 출력단에 충전된 전체 에너지가 한꺼번에 출력되어도 인체에 무해하도록 설계하였다. 구현한 자극기 모듈의 검증을 위하여 소형의 마이크로 프로세서를 이용하여 테스트 시스템을 구현하여 성능을 검증하였다.

  • PDF

고빈도 경피신경전기자극의 자극강도에 따른 정상 성인여성 교감신경성 반응의 변화 (Changes in Sympathetic Nervous System Responses of Healthy Adult Women with Changes in the Stimulus Intensity of High Frequency Transcutaneous Electrical Nerve Stimulation)

  • 최유림;이정우
    • The Journal of Korean Physical Therapy
    • /
    • 제22권1호
    • /
    • pp.61-66
    • /
    • 2010
  • Purpose: The purpose of this study was to investigate the change in sympathetic nervous system responses of healthy adult women with changes in stimulus intensity of high frequency transcutaneous electrical nerve stimulation. Methods: Twenty-four healthy subjects (women) received high frequency electrical stimulation of the forearm. The subjects were randomly assigned to one of two groups; a low intensity stimulation group (n=12) and a high intensity stimulation group (n=12). The electrode attachment was arranged on the forearm of the dominant arm and the electricity stimulus time was 20 minutes. Measured items included skin conductance, pulse rate, skin temperature, and respiration rate. Each was measured at 4 times. Results: Skin conductance and skin temperature showed significant group by time interactions, though there were no significant group and time effects. There were no significant differences according to time, group effect, and a group by time interaction in pulse and respiration rates. Conclusion: High frequency and high intensity electrical stimulation may be helpful for the improvement of sudomotor function through the activation of the sympathetic nervous system. Also, high frequency and low intensity electrical stimulation may be helpful for the reduction of sudomotor function via inhibition of the sympathetic nervous system.