• 제목/요약/키워드: Transcatheter aortic valve replacement

검색결과 18건 처리시간 0.026초

Diagnostic Efficacy and Safety of Low-Contrast-Dose Dual-Energy CT in Patients With Renal Impairment Undergoing Transcatheter Aortic Valve Replacement

  • Suyon Chang;Jung Im Jung;Kyongmin Sarah Beck;Kiyuk Chang;Yaeni Kim;Kyunghwa Han
    • Korean Journal of Radiology
    • /
    • 제25권7호
    • /
    • pp.634-643
    • /
    • 2024
  • Objective: This study aimed to evaluate the diagnostic efficacy and safety of low-contrast-dose, dual-source dual-energy CT before transcatheter aortic valve replacement (TAVR) in patients with compromised renal function. Materials and Methods: A total of 54 consecutive patients (female:male, 26:38; 81.9 ± 7.3 years) with reduced renal function underwent pre-TAVR dual-energy CT with a 30-mL contrast agent between June 2022 and March 2023. Monochromatic (40- and 50-keV) and conventional (120-kVp) images were reconstructed and analyzed. The subjective quality score, vascular attenuation, contrast-to-noise ratio (CNR), and signal-to-noise ratio (SNR) were compared among the imaging techniques using the Friedman test and post-hoc analysis. Interobserver reliability for aortic annular measurement was assessed using the intraclass correlation coefficient (ICC) and Bland-Altman analysis. The procedural outcomes and incidence of post-contrast acute kidney injury (AKI) were assessed. Results: Monochromatic images achieved diagnostic quality in all patients. The 50-keV images achieved superior vascular attenuation and CNR (P < 0.001 in all) while maintaining a similar SNR compared to conventional CT. For aortic annular measurement, the 50-keV images showed higher interobserver reliability compared to conventional CT: ICC, 0.98 vs. 0.90 for area and 0.97 vs. 0.95 for perimeter; 95% limits of agreement width, 0.63 cm2 vs. 0.92 cm2 for area and 5.78 mm vs. 8.50 mm for perimeter. The size of the implanted device matched CT-measured values in all patients, achieving a procedural success rate of 92.6%. No patient experienced a serum creatinine increase of ≥ 1.5 times baseline in the 48-72 hours following CT. However, one patient had a procedural delay due to gradual renal function deterioration. Conclusion: Low-contrast-dose imaging with 50-keV reconstruction enables precise pre-TAVR evaluation with improved image quality and minimal risk of post-contrast AKI. This approach may be an effective and safe option for pre-TAVR evaluation in patients with compromised renal function.

Comparison of Intracardiac Echocardiography Versus Transesophageal Echocardiography for Guidance During Transcatheter Aortic Valve Replacement

  • Sang-Hyup Lee;Seunguk Oh;Young-Guk Ko;Yong-Joon Lee;Seung-Jun Lee;Sung-Jin Hong;Chul-Min Ahn;Jung-Sun Kim;Byeong-Keuk Kim;Kyu-Yong Ko;Iksung Cho;Chi Young Shim;Geu-Ru Hong;Donghoon Choi;Myeong-Ki Hong
    • Korean Circulation Journal
    • /
    • 제54권2호
    • /
    • pp.63-75
    • /
    • 2024
  • Background and Objectives: Evidence regarding the efficacy and safety of intracardiac echocardiography (ICE) for guidance during transcatheter aortic valve replacement (TAVR) is limited. This study aimed to compare the clinical efficacy and safety of ICE versus transesophageal echocardiography (TEE) for guiding TAVR. Methods: This prospective cohort study included patients who underwent TAVR from August 18, 2015, to June 31, 2021. Eligible patients were stratified by echocardiographic modality (ICE or TEE) and anesthesia mode (monitored anesthesia care [MAC] or general anesthesia [GA]). Primary outcome was the 1-year composite of all-cause mortality, rehospitalization for cardiovascular cause, or stroke, according to the Valve Academic Research Consortium-3 (VARC-3) definition. Propensity score matching was performed, and study outcomes were analyzed for the matched cohorts. Results: Of the 359 eligible patients, 120 patients were matched for the ICE-MAC and TEEGA groups, respectively. The incidence of primary outcome was similar between matched groups (18.3% vs. 20.0%; adjusted hazard ratio, 0.94; 95% confidence interval [CI], 0.53-1.68; p=0.843). ICE-MAC and TEE-GA also had similar incidences of moderate-to-severe paravalvular regurgitation (PVR) (4.2% vs. 5.0%; adjusted odds ratio, 0.83; 95% CI, 0.23-2.82; p=0.758), new permanent pacemaker implantation, and VARC-3 types 2-4 bleeding. Conclusions: ICE was comparable to TEE for guidance during TAVR for the composite clinical efficacy outcome, with similar incidences of moderate-to-severe PVR, new permanent pacemaker implantation, and major bleeding. These results suggest that ICE could be a safe and effective alternative echocardiographic modality to TEE for guiding TAVR.

Successful emergency transcatheter aortic valve implantation

  • Lee, Jung-Hee;Ji, Ah-Young;Kim, Young Ju;Song, Changho;Jin, Moo-Nyun;Kim, Sun Wook;Hong, Myeong-Ki;Hong, Geu-Ru
    • Journal of Yeungnam Medical Science
    • /
    • 제31권2호
    • /
    • pp.144-147
    • /
    • 2014
  • Despite the necessity of surgical aortic valve replacement, many patients with symptomatic severe aortic stenosis (AS) cannot undergo surgery because of their severe comorbidities. In these high-risk patients, percutaneous transcatheter aortic valve implantation (TAVI) can be safely accomplished. However, no study has shown that TAVI can be performed for patients with severe AS accompanied by acute decompensated heart failure. In this case report, 1 patient presented a case of severe pulmonary hypertension with decompensated heart failure after diagnosis with severe AS, and was successfully treated via emergency TAVI. Without any invasive treatment, acute decompensated heart failure with severe pulmonary hypertension is common in patients with severe AS, and it can increase mortality rates. In conclusion, TAVI can be considered one of the treatment options for severe as presented as acute decompensated heart failure patients with pulmonary hypertension.

Niclosamide Inhibits Aortic Valve Interstitial Cell Calcification by Interfering with the GSK-3β/β-Catenin Signaling Pathway

  • Radhika Adhikari;Saugat Shiwakoti;Eunmin Kim;Ik Jun Choi;Sin-Hee Park;Ju-Young Ko;Kiyuk Chang;Min-Ho Oak
    • Biomolecules & Therapeutics
    • /
    • 제31권5호
    • /
    • pp.515-525
    • /
    • 2023
  • The most common heart valve disorder is calcific aortic valve stenosis (CAVS), which is characterized by a narrowing of the aortic valve. Treatment with the drug molecule, in addition to surgical and transcatheter valve replacement, is the primary focus of researchers in this field. The purpose of this study is to determine whether niclosamide can reduce calcification in aortic valve interstitial cells (VICs). To induce calcification, cells were treated with a pro-calcifying medium (PCM). Different concentrations of niclosamide were added to the PCM-treated cells, and the level of calcification, mRNA, and protein expression of calcification markers was measured. Niclosamide inhibited aortic valve calcification as observed from reduced alizarin red s staining in niclosamide treated VICs and also decreased the mRNA and protein expressions of calcification-specific markers: runt-related transcription factor 2 and osteopontin. Niclosamide also reduced the formation of reactive oxygen species, NADPH oxidase activity and the expression of Nox2 and p22phox. Furthermore, in calcified VICs, niclosamide inhibited the expression of β-catenin and phosphorylated glycogen synthase kinase (GSK-3β), as well as the phosphorylation of AKT and ERK. Taken together, our findings suggest that niclosamide may alleviate PCM-induced calcification, at least in part, by targeting oxidative stress mediated GSK-3β/β-catenin signaling pathway via inhibiting activation of AKT and ERK, and may be a potential treatment for CAVS.

Early Aortic Valve Replacement in Symptomatic Normal-Flow, Low-Gradient Severe Aortic Stenosis: A Propensity Score-Matched Retrospective Cohort Study

  • Kyu Kim;Iksung Cho;Kyu-Yong Ko;Seung-Hyun Lee;Sak Lee;Geu-Ru Hong;Jong-Won Ha;Chi Young Shim
    • Korean Circulation Journal
    • /
    • 제53권11호
    • /
    • pp.744-755
    • /
    • 2023
  • Background and Objectives: Aortic valve replacement (AVR) is considered a class I indication for symptomatic severe aortic stenosis (AS). However, there is little evidence regarding the potential benefits of early AVR in symptomatic patients diagnosed with normal-flow, low-gradient (NFLG) severe AS. Methods: Two-hundred eighty-one patients diagnosed with symptomatic NFLG severe AS (stroke volume index ≥35 mL/m2, mean transaortic pressure gradient <40 mmHg, peak transaortic velocity <4 m/s, and aortic valve area <1.0 cm2) between January 2010 and December 2020 were included in this retrospective study. After performing 1:1 propensity score matching, 121 patients aged 75.1±9.8 years (including 63 women) who underwent early AVR within 3 months after index echocardiography, were compared with 121 patients who received conservative care. The primary outcome was a composite of all-cause death and heart failure (HF) hospitalization. Results: During a median follow-up of 21.9 months, 48 primary outcomes (18 in the early AVR group and 30 in the conservative care group) occurred. The early AVR group demonstrated a significantly lower incidence of primary outcomes (hazard ratio [HR], 0.52; 95% confidence interval [CI], 0.29-0.93; p=0.028); specifically, there was no significant difference in all-cause death (HR, 0.51; 95% CI, 0.23-1.16; p=0.110), although the early AVR group showed a significantly lower incidence of hospitalization for HF (HR, 0.43; 95% CI, 0.19-0.95, p=0.037). Subgroup analyses supported the main findings. Conclusions: An early AVR strategy may be beneficial in reducing the risk of a composite outcome of death or hospitalization for HF in symptomatic patients with NFLG severe AS. Future randomized studies are required to validate and confirm our findings.

Distribution of Aortic Root Calcium in Relation to Frame Expansion and Paravalvular Leakage After Transcatheter Aortic Valve Implantation (TAVI): An Observational Study Using a Patient-specific Contrast Attenuation Coefficient for Calcium Definition and Independent Core Lab Analysis of Paravalvular Leakage

  • Nahid El Faquir;Quinten Wolff;Rafi Sakhi;Ben Ren;Zouhair Rahhab;Sander van Weenen;Patrick Geeve;Ricardo P J Budde;Eric Boersma;Joost Daemen;Nicolas M van Mieghem;Peter P de Jaegere
    • Journal of Cardiovascular Imaging
    • /
    • 제30권4호
    • /
    • pp.292-304
    • /
    • 2022
  • BACKGROUND: Calcium is a determinant of paravalvular leakage (PVL) after transcatheter aortic valve implantation (TAVI). This is based on a fixed contrast attenuation value while X-ray attenuation is patient-dependent and without considering frame expansion and PVL location. We examined the role of calcium in (site-specific) PVL after TAVI using a patient-specific contrast attenuation coefficient combined with frame expansion. METHODS: 57 patients were included with baseline CT, post-TAVI transthoracic echocardiography and rotational angiography (R-angio). Calcium load was assessed using a patient-specific contrast attenuation coefficient. Baseline CT and post-TAVI R-angio were fused to assess frame expansion. PVL was assessed by a core lab. RESULTS: Overall, the highest calcium load was at the non-coronary-cusp-region (NCR, 436 mm3) vs. the right-coronary-cusp-region (RCR, 233 mm3) and the left-coronary-cusp-region (LCR, 244 mm3), p < 0.001. Calcium load was higher in patients with vs. without PVL (1,137 vs. 742 mm3, p = 0.012) and was an independent predictor of PVL (odds ratio, 4.83, p = 0.004). PVL was seen most often in the LCR (39% vs. 21% [RCR] and 19% [NCR]). The degree of frame expansion was 71% at the NCR, 70% at the RCR and 74% at the LCR without difference between patients with or without PVL. CONCLUSIONS: Calcium load was higher in patients with PVL and was an independent predictor of PVL. While calcium was predominantly seen at the NCR, PVL was most often at the LCR. These findings indicate that in addition to calcium, specific anatomic features play a role in PVL after TAVI.

POST-TAVR ECG 기반의 PPI 예측 모델 연구 (Research of PPI prediction model based on POST-TAVR ECG)

  • 송인서;양세모;이강윤
    • 인터넷정보학회논문지
    • /
    • 제25권2호
    • /
    • pp.29-38
    • /
    • 2024
  • 경피적 대동맥 판막 치환술(TAVR) 후에는 인공 심박동기 삽입술(PPI)을 비롯한 TAVR 이후 합병증에 대한 철저한 관리가 필요하며 그에 따라 정확한 예측 모델에 대한 필요성이 점점 증가하고 있다. 본 연구는 기존의 이미지 의존적 방법론에서 벗어나 ECG 정보를 중심으로 예측하는 XGBoost 기반의 최적의 PPI 예측 모델을 개발했다. 이 모델은 심전도상의 특정 신호들인 DeltaPR, DeltaQRS 등을 주요 지표로 삼아, 환자의 전도 장애 및 PPI와의 연관성을 파악하며, 기존의 이미지와 ECG 데이터를 결합한 모델과 ECG 기반의 모델 보다 뛰어난 AUC 0.91 성능을 달성하였다. 본 연구에서 제안하는 모델은 두 병원의 데이터를 기반으로 최적의 PPI 예측 모델을 구현 및 검증하였으며, 검증 결과 ECG 데이터의 특성이 PPI 예측에 큰 영향을 미치며 95.28%의 높은 유사도를 보였다. 이로써 본 연구의 예측 모델이 다양한 병원 데이터에도 효과적으로 적용될 수 있음을 확인하였다. 최적의 머신러닝 알고리즘을 사용하여 PPI와 각 특성 간의 상관관계를 명확히 했으며, 고비용의 의료 이미지에 의존하지 않고 ECG 데이터를 사용하여 높은 정확도로 PPI를 예측할 수 있음을 입증하였다. 이는 의료 결정 과정에서 인간 개입의 의존도를 줄이며, 신뢰할 수 있고 실용적인 PPI 예측 모델 개발로의 중요한 진전을 의미한다.