• Title/Summary/Keyword: Transcatheter Aortic Valve Replacement

Search Result 20, Processing Time 0.02 seconds

Right anterior mini-thoracotomy aortic valve replacement versus transcatheter aortic valve implantation in octogenarians: a single-center retrospective study

  • Ji Eun Im;Eun Yeung Jung;Seok Soo Lee;Ho-Ki Min
    • Journal of Yeungnam Medical Science
    • /
    • v.41 no.2
    • /
    • pp.96-102
    • /
    • 2024
  • Background: The aim of this study was to compare the early outcomes of octogenarians undergoing minimally invasive right anterior mini-thoracotomy aortic valve replacement (RAT-AVR) with those undergoing transcatheter aortic valve implantation (TAVI) for aortic valve disease. Methods: In this single-center retrospective study, data were collected from octogenarians before and after RAT-AVR and TAVI between January 2021 and July 2022. Short-term outcomes, including the length of hospital stay, in-hospital mortality, all-cause mortality, and other major postoperative complications, were compared and analyzed. Results: There were no significant differences in in-hospital mortality, stroke, acute kidney dysfunction requiring renal replacement therapy, length of intensive care unit stay, or length of hospital stay. However, the TAVI group had a higher incidence of permanent pacemaker insertion (10% vs. 0%, p=0.54) and paravalvular leaks (75% vs. 0%, p<0.001). Conclusion: In the present study on octogenarians, both TAVI and RAT-AVR showed comparable short-term results. Although both procedures were considered safe and effective in the selected group, RAT-AVR had a lower incidence of complete atrioventricular block and paravalvular regurgitation.

Recent updates in transcatheter aortic valve implantation

  • Cho, Jeonghwan;Kim, Ung
    • Journal of Yeungnam Medical Science
    • /
    • v.35 no.1
    • /
    • pp.17-26
    • /
    • 2018
  • Transcatheter aortic valve implantation (TAVI) has evolved from a challenging intervention to a standardized, simple, and streamlined procedure with over 350,000 procedures performed in over 70 countries. It is now a novel alternative to surgical aortic valve replacement in patients with intermediate surgical risk and its indications have been expanded to cohorts with bicuspid aortic valves, low surgical risk, and younger age and fewer comorbidities. Attention should be paid to further reducing remaining complications, such as paravalvular aortic regurgitation, conduction abnormalities, cardiac tamponade, and stroke. The aim of this review is to provide an overview on the rapidly changing field of TAVI treatment and to explore past achievements, current issues, and future perspectives of this treatment modality.

Transcatheter Mitral Valve Implantation in Open Heart Surgery: An Off-Label Technique

  • Alfonsi, Jacopo;Murana, Giacomo;Corsini, Anna;Savini, Carlo;Di Bartolomeo, Roberto;Pacini, Davide
    • Journal of Chest Surgery
    • /
    • v.50 no.6
    • /
    • pp.467-470
    • /
    • 2017
  • Extensive mitral annulus calcifications are considered a contraindication for valve surgery. We describe the case of a 76-year-old female with severe mitral and aortic stenosis associated with extensive calcifications of the heart. The patient underwent an open mitroaortic valve replacement using transcatheter aortic valve implantation with an Edwards SAPIEN XT valve (Edwards Lifesciences Corp., Irvine, CA, USA) in the mitral position. The aortic valve was replaced using a stentless valve prosthesis (LivaNova S OLO; LivaNova PLC, London, UK). Postoperative echocardiography showed that the prosthetic valve was in the correct position and there were no paravalvular leaks. A bailout open transcatheter valve implantation can be considered a safe and effective option in selected cases with an extensively calcified mitral valve.

Design of Post-TAVR Digital Twin Navigating Platform for Predicting Patient Complications (환자의 합병증 예측을 위한 Post-TAVR디지털 트윈 추적 관리 플랫폼 설계)

  • Min Hyuk Jung;KangYoon Lee
    • Journal of Internet Computing and Services
    • /
    • v.25 no.5
    • /
    • pp.31-40
    • /
    • 2024
  • Aortic valve stenosis is disease caused by the calcification of the aortic valve, which is located between the left ventricle of the heart and the aorta, preventing the backflow of blood. Transcatheter Aortic Valve Replacement (TAVR) has become the standard non-surgical procedure for treating aortic stenosis. However, patients who undergo TAVR are still face the risk of complication, which calls for a systematic solution for complication prediction and management. In this study, we designed a platform that manages patient complication risks using various prediction models, and we utilized explainable AI to ensure reliable prediction models and solutions. For the implementation of this platform, digital twin technology was employed, allowing for complication prediction and monitoring based on a patient's digital twin model constructed from Real-World Data (RWD). The digital twin platform has been developed with a microservice architecture using Kubernetes, enhancing the flexibility and availability of the platform. Additionally, we propose a feedback system for continuous improvement of prediction model performance and TAVR procedures to ensure ongoing development.

Comparison of Early Clinical Results of Transcatheter versus Surgical Aortic Valve Replacement in Symptomatic High Risk Severe Aortic Stenosis Patients

  • Yu, Woo Sik;Chang, Byung-Chul;Joo, Hyun Chel;Ko, Young-Guk;Lee, Sak
    • Journal of Chest Surgery
    • /
    • v.46 no.5
    • /
    • pp.346-352
    • /
    • 2013
  • Background: Transcatheter aortic valve implantation (TAVI) has been an alternative to conventional aortic valve replacement (AVR) in old and high risk patients. The goal of this study is to compare the early outcomes of conventional AVR vs. TAVI in high risk severe AS patients. Methods: From January 2008 to July 2012, 44 high risk severe aortic stenosis patients underwent conventional AVR, and 15 patients underwent TAVI. We compared echocardiographic data, periprocedural complication, and survival. The mean follow-up duration was $14.5{\pm}10$ months (AVR), and $6.8{\pm}3.5$ months (TAVI), respectively. Results: AVR group was younger ($78.2{\pm}2.4$ years vs. $82.2{\pm}3.0$ years, p<0.001) and had lower operative risk (Euroscore: $9.4{\pm}2.7$ vs. $11.0{\pm}2.0$, p=0.044) than TAVI group. There was no significant difference in early mortality (11.4% vs. 13.3%, p=0.839), and 1 year survival ($87.4%{\pm}5.3%$ vs. $83.1%{\pm}1.1%$, p=0.805). There was no significant difference in postoperative functional class. There was no significant difference in periprocedural complication except vascular complication (0% [AVR] vs. 13.3% [TAVI], p=0.014). TAVI group had more moderate and severe paravalvular leakage. Conclusion: In this study, both groups had similar periprocedural morbidity, and mortality. However, TAVI group had more greater than moderate paravalvular leakage, which can influence long-term outcome. Since more patients are treated with TAVI even in moderate risk, careful selection of the patients and appropriate guideline need to be established.

Aortic Valve Replacement for Aortic Stenosis in Elderly Patients (75 Years or Older)

  • Sohn, Bongyeon;Choi, Jae Woong;Hwang, Ho Young;Kim, Kyung Hwan;Kim, Ki-Bong
    • Journal of Chest Surgery
    • /
    • v.51 no.5
    • /
    • pp.322-327
    • /
    • 2018
  • Background: This study evaluated the early and long-term outcomes of surgical aortic valve replacement (AVR) in elderly patients in the era of transcatheter aortic valve implantation. Methods: Between 2001 and 2018, 94 patients aged ${\geq}75years$ underwent isolated AVR with stented bioprosthetic valves for aortic valve stenosis (AS). The main etiologies of AS were degenerative (n=63) and bicuspid (n=21). The median follow-up duration was 40.7 months (range, 0.6-174 months). Results: Operative mortality occurred in 2 patients (2.1%) and paravalvular leak occurred in 1 patient. No patients required permanent pacemaker insertion after surgery. Late death occurred in 11 patients. The overall survival rates at 5 and 10 years were 87.2% and 65.1%, respectively. The rates of freedom from valve-related events at 5 and 10 years were 94.5% and 88.6%, respectively. The Society of Thoracic Surgeons (STS) score (p=0.013) and chronic kidney disease (p=0.030) were significant factors affecting long-term survival. The minimal p-value approach demonstrated that an STS score of 3.5% was the most suitable cut-off value for predicting long-term survival. Conclusion: Surgical AVR for elderly AS patients may be feasible in terms of early mortality and postoperative complications, particularly paravalvular leak and permanent pacemaker insertion. The STS score and chronic kidney disease were associated with long-term outcomes after AVR in the elderly.

Aortic Stenosis: New Insights in Diagnosis, Treatment, and Prevention

  • Saki Ito;Jae K. Oh
    • Korean Circulation Journal
    • /
    • v.52 no.10
    • /
    • pp.721-736
    • /
    • 2022
  • Aortic stenosis (AS) is one of the most common valvular heart diseases and the number of patients with AS is expected to increase globally as the older population is growing fast. Since the majority of patients are elderly, AS is no longer a simple valvular heart disease of left ventricular outflow obstruction but is accompanied by other cardiac and comorbid conditions. Because of the significant variations of the disease, identifying patients at high risk and even earlier detection of patients with AS before developing symptomatic severe AS is becoming increasingly important. With the proven of efficacy and safety of transcatheter aortic valve replacement (TAVR) in the severe AS population, there is a growing interest in applying TAVR in those with less than severe AS. A medical therapy to reduce or prevent the progression in AS is actively investigated by several randomized control trials. In this review, we will summarize the most recent findings in AS and discuss potential future management strategies of patients with AS.

Comparison of the Outcomes between Surgical Aortic Valve Replacement and Transcatheter Aortic Valve Replacement in Patients Aged above 80

  • Lee, Jeong-Woo;Kim, Jihoon;Jung, Sung-Ho;Chung, Cheol Hyun;Lee, Jae Won
    • Journal of Chest Surgery
    • /
    • v.50 no.4
    • /
    • pp.255-262
    • /
    • 2017
  • Background: Transcatheter aortic valve replacement (TAVR) has been suggested as a less invasive treatment for high-risk patients with aortic valve disease. I n this study, we compared the outcomes of conventional surgical aortic valve replacement (AVR) and TAVR in elderly patients aged over 80. Methods: A total of 108 patients aged 80 years or older who underwent isolated AVR (n=35) or TAVR (n=73) from 2010 through 2015 at Asan Medical Center were identified. Early and late clinical outcomes, including echocardiographic findings, were evaluated in both groups. The mean follow-up duration was $766.4{\pm}528.7days$ in the AVR group and $755.2{\pm}546.6days$ in the TAVR group, and the average timing of the last follow-up echocardiography was at $492.6{\pm}512.5days$ in the AVR group and $515.7{\pm}526.8days$ in the TAVR group. Results: The overall early mortality was 2.8% (0 of 35, 0% in the AVR group vs. 3 of 73, 4.1% in the TAVR group). Permanent pacemaker insertion was significantly more common in the TAVR group (p=0.010). Renal failure requiring dialysis and new-onset atrial fibrillation was more frequent and the length of hospital stay was longer in the AVR group; however, this difference did not reach statistical significance. In the TAVR group, 14 patients (19.2%) were rehospitalized due to cardiac problems, and 13 patients (17.8%) had developed significant paravalvular leakage by the time of the last follow-up echocardiography. Conclusion: TAVR could be a good alternative to conventional surgical AVR in elderly patients. However, TAVR has several shortcomings, such as frequent significant paravalvular leakage or readmission, which should be considered in decision-making.

Guidelines for Transcatheter Aortic Valve Replacement in Korea: Past Obstacles and Future Perspectives

  • Choo, Suk Jung;Shinn, Sung Ho;Kim, Kyung Hwan;Kim, Wook Sung;Oh, Sam-Sae;Lee, Sak
    • Journal of Chest Surgery
    • /
    • v.51 no.4
    • /
    • pp.231-240
    • /
    • 2018
  • Background: Analyses of the efficacy and safety of transcatheter aortic valve replacement (TAVR) in most countries have been based on outcomes obtained in accordance with national practice guidelines and monitoring protocols. The purpose of this study is to share our experience regarding the process for establishing guidelines and monitoring protocols for the use of TAVR in Korea, in the hopes that it may be helpful to others undergoing a similar process in their own country. Methods: The Korean guidelines for TAVR were established on June 1, 2015 in through a tri-party agreement involving the Department of Health and Welfare, the Korean Society of Thoracic and Cardiovascular Surgery and the Korean Society of Cardiology. We agreed to monitor the guidelines transparently and to exchange opinions regarding amendments or continuation of its contents after 3 years of monitoring. Results: The monitoring meetings were not held as regularly as agreed, and monitoring was also made difficult by insufficient and incomplete data. Nevertheless, during the meetings, measures to improve the monitoring process were discussed, and accordingly, an agreement was made to continue the monitoring process, with the aim of completing data collection by 2018. Conclusion: Compliance with guidelines is critical for assessing the efficacy and safety of TAVR. Moreover, the TAVR monitoring process must be properly conducted for an accurate evaluation to be made. Any country planning to introduce TAVR may encounter difficulties with regards to the optimal initiation strategy and subsequent monitoring. Nevertheless, continued efforts should be made to persuade the government and the corresponding medical societies to facilitate the optimal application of TAVR.

Low Contrast and Low kV CTA Before Transcatheter Aortic Valve Replacement: A Systematic Review

  • Spencer C. Lacy;Mina M. Benjamin;Mohammed Osman;Mushabbar A. Syed;Menhel Kinno
    • Journal of Cardiovascular Imaging
    • /
    • v.31 no.2
    • /
    • pp.108-115
    • /
    • 2023
  • BACKGROUND: Minimizing contrast dose and radiation exposure while maintaining image quality during computed tomography angiography (CTA) for transcatheter aortic valve replacement (TAVR) is desirable, but not well established. This systematic review compares image quality for low contrast and low kV CTA versus conventional CTA in patients with aortic stenosis undergoing TAVR planning. METHODS: We performed a systematic literature review to identify clinical studies comparing imaging strategies for patients with aortic stenosis undergoing TAVR planning. The primary outcomes of image quality as assessed by the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were reported as random effects mean difference with 95% confidence interval (CI). RESULTS: We included 6 studies reporting on 353 patients. There was no difference in cardiac SNR (mean difference, -1.42; 95% CI, -5.71 to 2.88; p = 0.52), cardiac CNR (mean difference, -3.83; 95% CI, -9.98 to 2.32; p = 0.22), aortic SNR (mean difference, -0.23; 95% CI, -7.83 to 7.37; p = 0.95), aortic CNR (mean difference, -3.95; 95% CI, -12.03 to 4.13; p = 0.34), and ileofemoral SNR (mean difference, -6.09; 95% CI, -13.80 to 1.62; p = 0.12) between the low dose and conventional protocols. There was a difference in ileofemoral CNR between the low dose and conventional protocols with a mean difference of -9.26 (95% CI, -15.06 to -3.46; p = 0.002). Overall, subjective image quality was similar between the 2 protocols. CONCLUSIONS: This systematic review suggests that low contrast and low kV CTA for TAVR planning provides similar image quality to conventional CTA.