• 제목/요약/키워드: Train Station

검색결과 379건 처리시간 0.026초

Calibration of Timetable Parameters for Rail-Guided Systems

  • Zhao, Weiting;Martin, Ullrich;Cui, Yong;Kosters, Maureen
    • International Journal of Railway
    • /
    • 제9권1호
    • /
    • pp.1-9
    • /
    • 2016
  • In order to achieve a comprehensive utilization of railway networks, it is necessary to accurately assess the timetable indicators that effect the train operation. This paper describes the parameter calibration for two timetable indicators: scheduled running time and scheduled dwell time. For the scheduled running time, an existing model is employed and the single timetable parameter (percentage of minimum running time) in that model is optimized. For the scheduled dwell time, two intrinsic characteristics: the significance of stations and the average headway at each station are proposed firstly to form a new model, and the corresponding timetable parameters (the weight of the significance and the weight of the average headway) are calibrated subsequently. The Floyd Algorithm is used to obtain the connectivity among stations, which represents the significance of the stations. A case study is conducted in a light rail transportation system with 17 underground stations. The results of this research show that the optimal value of the scheduled running time parameter can be automatically determined, and the proposed model for the scheduled dwell time works well with a high coefficient of determination and low relative root mean square error through the leave-one-out validation.

블루투스를 이용한 데이터 처리 프레임워크 설계 (Data Processing Framework Design by Bluetooth)

  • 남용수;김태용
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2009년도 춘계학술대회
    • /
    • pp.455-458
    • /
    • 2009
  • 블루투스 기술은 이동 단말, 개인용 컴퓨터 및 주변기기, 정보가전 등에 다양하게 적용되어 왔다. 이러한 적용 영역들 중에서도 원래 블루투스 기술의 최대 관심인 휴대폰에의 적용이 가장 비약적으로 이루어져, 현재는 무선 헤드셋 및 전화접속 네트워킹 등의 응용에 사용되고 있다. 하지만 현재의 블루투스 기술은 무선 헤드셋 영역에 집중되어 있고 다양한 소프트웨어 응용 및 적용 사례가 미약하다. 본 논문에서는 블루투스 노드와 블루투스 AP(Access Point)를 이용하여 영화관, 기차역, 은행, 관공서 등의 다양한 장소의 키오스크 서버(Kiosk Server)에 원격으로 접속하여 모바일 단말기기는 사용자의 입력과 출력만을 담당하여 키오스크 서버에 전달되고 키오스크 서버는 전달된 데이터를 처리하여 사용자에게 전달하는 Profile의 프레임워크를 설계하여 차후 구현을 목표로 한다.

  • PDF

Teaching-learning-based strategy to retrofit neural computing toward pan evaporation analysis

  • Rana Muhammad Adnan Ikram;Imran Khan;Hossein Moayedi;Loke Kok Foong;Binh Nguyen Le
    • Smart Structures and Systems
    • /
    • 제32권1호
    • /
    • pp.37-47
    • /
    • 2023
  • Indirect determination of pan evaporation (PE) has been highly regarded, due to the advantages of intelligent models employed for this objective. This work pursues improving the reliability of a popular intelligent model, namely multi-layer perceptron (MLP) through surmounting its computational knots. Available climatic data of Fresno weather station (California, USA) is used for this study. In the first step, testing several most common trainers of the MLP revealed the superiority of the Levenberg-Marquardt (LM) algorithm. It, therefore, is considered as the classical training approach. Next, the optimum configurations of two metaheuristic algorithms, namely cuttlefish optimization algorithm (CFOA) and teaching-learning-based optimization (TLBO) are incorporated to optimally train the MLP. In these two models, the LM is replaced with metaheuristic strategies. Overall, the results demonstrated the high competency of the MLP (correlations above 0.997) in the presence of all three strategies. It was also observed that the TLBO enhances the learning and prediction accuracy of the classical MLP (by nearly 7.7% and 9.2%, respectively), while the CFOA performed weaker than LM. Moreover, a comparison between the efficiency of the used metaheuristic optimizers showed that the TLBO is a more time-effective technique for predicting the PE. Hence, it can serve as a promising approach for indirect PE analysis.

지하철 역사내 기능실에 대한 무선 센서 네트워크 성능 분석 (Performance Evaluation of Wireless Sensor Networks in the Subway Station of Workroom)

  • 안태기;신정렬;김갑영;양세현;최갑봉;심보석
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.1701-1708
    • /
    • 2011
  • 지하철은 대표적인 교통수단으로 하루에도 수십만 명이 이용하고 있어 안전에 대한 관심이 높으며 지하철의 각종 기능실에서의 화재 등으로 이하여 지하철 이용자들에게까지 피해를 입을 수 있는 가능이 제기되고 있는 실정이다. 실제로 2010년에는 환기실에서의 화재로 환기구를 통해 연기 및 유해가스로 인해 인명 피해 및 열차 운행 중단사고 등의 사례까지 보도되기도 하고 있다. 이러한 사고에 대응하기 위해 지하철 역사의 경우에도 최신의 IT기술인 무선센서네트워크기술 및 지능형영상감시기술 등과 접목하여 화재 및 역사 건전성 등을 종합적으로 감시하는 도시철도지능형종합감시시스템 개발 및 연구 중에 있다. 이를 위하여 본 연구에서는 개발 중인 도시철도 지능형 종합 감시시스템의 현장 역사 적용에 앞서 ZigBee 기반의 무선센서네트워크 성능 시험을 서울지하철 충무로 역사에서 수행하였고, 본 논문에 충무로역사 내부 통신기계실과 환기실, 전기실에서의 ZigBee기반 무선통신환경 시험결과를 정리, 분석하였다. (주)휴텍21에서 개발한 ZigBee 센서노드와 게이트웨이를 이용한 무선데이터 전송 시험 결과, 데이터 전송은 기능실 내의 각종 전자 및 기계설비로 인한 멀티패스 페이딩(multi-path fading)의 영향을 받는 것으로 나타났으며 통신기계실과 같이 여러 개의 작은 공간으로 구분되어진 곳에 대한 게이트웨이의 안테나 및 센서노드 설치 지점 선정 시 이를 고려하여야 할 것으로 판단된다.

  • PDF

서울시 지하철 승강장의 스크린도어 설치 전·후 PM10 오염원의 기여도 비교 연구 (A Comparative Study on PM10 Source Contributions in a Seoul Metropolitan Subway Station Before/After Installing Platform Screen Doors)

  • 이태정;전재식;김신도;김동술
    • 한국대기환경학회지
    • /
    • 제26권5호
    • /
    • pp.543-553
    • /
    • 2010
  • Almost five million citizens a day are using subways as a means of traffic communication in the Seoul metropolitan. As the subway system is typically a closed environment, indoor air pollution problems frequently occurs and passengers complain of mal-health impact. Especially $PM_{10}$ is well known as one of the major pollutants in subway indoor environments. The purpose of this study was to compare the indoor air quality in terms of $PM_{10}$ and to quantitatively compare its source contributions in a Seoul subway platform before and after installing platform screen doors (PSD). $PM_{10}$ samples were collected on the J station platform of Subway Line 7 in Seoul metropolitan area from Jun. 12, 2008 to Jan. 12, 2009. The samples collected on membrane filters using $PM_{10}$ mini-volume portable samplers were then analyzed for trace metals and soluble ions. A total of 18 chemical species (Ba, Mn, Cr, Cd, Si, Fe, Ni, Al, Cu, Pb, Ti, $Na^+$, $NH_4^+$, $K^+$, $Mg^{2+}$, $Ca^{2+}$, $Cl^-$, and ${SO_4}^{2-}$) were analyzed by using an ICP-AES and an IC after performing proper pre-treatments of each sample filter. Based on the chemical information, positive matrix factorization (PMF) model was applied to identify the source of particulate matters. $PM_{10}$ for the station was characterized by three sources such as ferrous related source, soil and road dust related source, and fine secondary aerosol source. After installing PSD, the average $PM_{10}$ concentration was decreased by 20.5% during the study periods. Especially the contribution of the ferrous related source emitted during train service in a tunnel route was decreased from 59.1% to 43.8% since both platform and tunnel areas were completely blocked by screen doors. However, the contribution of the fine secondary aerosol source emitted from various outside combustion activities was increased from 14.8% to 29.9% presumably due to ill-managed ventilation system and confined platform space.

해저터널 구난역 플랫폼 화재연기확산 방지를 위한 에어커튼 시스템 차연성능 시뮬레이션 연구 (Simulation study of smoke spread prevention using air curtain system in rescue station platform of undersea tunnel)

  • 박상헌;안승주;한상주;유용호
    • 한국터널지하공간학회 논문집
    • /
    • 제17권3호
    • /
    • pp.257-266
    • /
    • 2015
  • 본 연구는 국내에서 계획하고 있는 호남-제주간 초장대 해저터널에서 철도차량의 화재 발생시 구난역 (Rescue Station)에 정차후 대피자의 안전한 대피경로를 확보하고 플랫폼 내부에 연기가 유입되는 것을 방지하기 위해 구난역 플랫폼과 화재열차 사이에 에어커튼 시스템(Air curtain system)을 설치하여, 15MW급 화재연기에 대한 차단성능 및 최적화방안을 도출하기 위해 다양한 시뮬레이션을 수행하였다. 시뮬레이션 결과, 모든 CASE에서 15 MW급 화재강도에 발생되는 연기에서도 효과적인 차연성능을 발휘하였으며, CASE1(화재열차 방향으로 15도 분사)와 CASE5(화재열차 방향으로 15도 분사 + 가압송풍)가 구난역 플랫폼 내부에 CO가스 유입이 가장 적은 것으로 도출하였다. 이러한 결과를 통하여 에어커튼 시스템은 초장대 해저터널 구난역에 화재시 플랫폼에 화재연기가 유입되지 않고 안전한 대피 경로를 확보하여 대피자가 서비스 터널로 안전하게 대피하여 인명피해를 최소화 할 수 있는 방재시설로서 활용되기를 기대한다.

도시철도 지하역사 PSD 설치에 따른 배기시스템 개선 연구 (A study on the improvement of the air exhaust system at the PSD installed subway station)

  • 권순박;송지한;류승원;조주환;오태석;배성준;김효규
    • 한국터널지하공간학회 논문집
    • /
    • 제17권3호
    • /
    • pp.353-362
    • /
    • 2015
  • 도시철도 지하역사에 설치되어 운영중인 승강장 안전문(PSD)은 승객의 추락방지 등 안전사고 예방에 큰 기여를 하고 있지만, 기존 승강장 선로 배기설비의 차단으로 인해, 일부 역사에서 승강장내 환기효율 저하문제를 발생시키고 있다. 본 연구에서는 PSD가 설치된 승강장의 기존 급배기 시스템의 환기효율 개선을 위해, 승강장과 대합실로 통하는 계단부 하부공간의 무효한 공간(창고)에 국부적인 하부 배기시스템을 추가하고, 승강장 배기용 덕트를 선로부의 기존 배기시스템에 연결하여 연동함으로써 기존 시스템에 무리 없이 승강장 실내환경을 개선하고자 하였다. 즉, PSD 설치이후 승강장 내부의 전체적인 기류혼합효과와 오염된 실내공기를 효율적으로 배출하기 위한 하부배기 방식을 연구하였다. 이러한 하부배기 방식의 효과를 예측하기 위하여, 서울지하철 2호선 역사를 선정하여 급배기량을 실측하고, 이를 바탕으로 전산수치해석 연구를 수행하여 개선효과를 예측해보았다. 하부 배기시스템의 적용은 승강장 기류의 지체상태 및 환기효율 특성을 나타내는 공기연령 측면에서 약 16.5%의 개선효과가 있는 것으로 분석되었다.

차량-궤도 상호작용 해석을 통한 사전 제작형 플로팅 슬래브 궤도의 동적 안정성 검토 (Evaluation of Dynamic Stability of Precast Floating Slab Track with Vehicle-Track Interaction Analysis)

  • 장동두;김진호;권세곤
    • 한국산학기술학회논문지
    • /
    • 제18권3호
    • /
    • pp.562-568
    • /
    • 2017
  • 기존 선하역사의 소음 및 진동 문제를 해결하기 위해 제안된 사전 제작형 플로팅 슬래브 궤도는 길이 5m 정도의 슬래브 패널을 공장에서 제작하고 방진장치를 설치하여 일체화한 궤도이다. 이를 통해 별도의 열차 운행 중단 없이 급속 시공이 가능하여 신설역사 뿐 아니라 기존 선하 역사에 적용이 가능한 장점이 있다. 그러나 패널 길이가 5m로 짧아 실제 시공 구간 길이에 따라 다수의 패널이 설치되어야 함에 따라 궤도의 불연속 구간이 많이 발생한다. 또한 플로팅 슬래브 궤도의 작동 원리 상 일반 궤도에 비해 차량 운행으로 인한 과도한 변위가 발생할 여지가 있고 기존 궤도와의 접속부에서의 지지강성 차이로 인해 동적 불안정성이 발생할 우려가 있다. 본 연구에서는 사전 제작형 플로팅 슬래브 궤도에 대해 차량-궤도 상호작용 해석을 수행하여 윤중변동율, 차체가속도, 레일응력 및 상압력의 검토를 통해 동적 안정성을 확인하였다. 검토 결과 플로팅 궤도 구간 내에서의 동적 안정성은 확보하는 것으로 나타났지만 기존 궤도와의 접속부에서는 일부 기준을 초과하는 것으로 나타나 이를 해소하기 위한 방진장치 배치 방안을 제시하였다.

나노버블을 이용한 지하철용 전기집진기 포집먼지에 대한 세척효율 평가 (Evaluation of Washing Efficiency of Collective PM by Electrostatic Precipitator in Subway Station Using Nano Bubble)

  • 이형돈;이승환;박찬규
    • 청정기술
    • /
    • 제26권1호
    • /
    • pp.13-21
    • /
    • 2020
  • 지하역사 내 대기오염물질은 외부에서 유입되거나 또는 지하철 내부의 승객 승·하차 시 발생하는 등 여러 가지 요인에 의해 복합적으로 발생한다. 최근 연구 결과에 따르면, 지하역사 내 터널 및 지하철역에서 발생하는 대부분의 대기오염물질은 열차풍에 의해 발생되는 것과 같이 내부적 요인에 많은 영향을 많이 받는 것으로 알려져 있다. 이러한 대기오염물질을 제어하기 위해서는 지하철역사 내에 전기집진장치와 같은 집진시설이 필요하며, 집진장치에 의해 제거된 미세먼지를 보다 효율적으로 관리하기 위해서는 집진장치 내부에 지속적인 세척이 필수적이다. 따라서 본 연구에서는 지하역사에 설치할 전기집진장치 내부 집진판에 쌓인 미세먼지를 세척하기 위한 나노버블세척 장치를 개발하였고 나노버블수의 먼지세척효율을 평가하고자 하였다. 실험 결과, 분사압 증가에 따라 세척 효율이 일정하게 증가하였고 나노버블수로 세척할 경우 수돗물로 세척한 경우보다 부착먼지 제거효율이 130.8% 더 증가하였다. 세척횟수 증가에 따라 최대 제거효율은 수돗물에 비해 143.1% 높았지만 적합한 세척횟수는 3회 미만인 것으로 나타났다. 또한 나노버블수 체류시간 변화에 따른 세척효율 실험결과, 나노버블수의 최대 체류시간은 5분 이내로 유지됨을 확인하였다.

스크린도어가 설치된 대심도 지하역사의 제연 실험 - 터널 송풍기에 의한 제연의 효과 분석 (Smoke Control Experiment of a Very Deep Underground Station Where Platform Screens Doors are Installed - Analysis on Smoke Control Performance by Fans equipped in Tunnel)

  • 박원희;김창용;조영민
    • 예술인문사회 융합 멀티미디어 논문지
    • /
    • 제9권9호
    • /
    • pp.721-736
    • /
    • 2019
  • 본 논문에서는 대심도에 위치한 지하역사(지하 6층) 및 터널에서 화재가 발생했을 경우 제연설비 작동에 따른 연기의 거동을 측정하였다. 열풍기를 이용하여 열부력 효과를 구현한 연기발생장치를 이용하여 화재연기를 생성하였다. 화재발생 위치는 승강장 위 및 스크린도어 외부에 위치한 터널부의 승강장 위의 2가지 위치를 선정하였다. 승강장 화재발생시 승강장에 설치된 환기구를 통하여 연기가 배출되도록 하는 제연모드가 일반적인데 본 연구에서는 승강장 양단에 위치한 터널부의 환기구를 통한 배기도 같이 동작되도록 설정하여 실험을 수행하였다. 다양한 위치에서 연기농도 및 풍향풍속을 측정하였고 화면을 취득하여 연기의 이동 및 제연을 분석하였다. 승강장 내부에서 화재가 발생하였을 경우와 선로부에서 화재가 발생하였을 경우 승강장의 송풍기의 제연모드 동작과 터널의 송풍기의 배연 동작으로 인하여 연기배출이 원활하였고 화재 발생 인근 구역으로의 연기전파가 억제되었다. 본 연구에서 제시한 승강장 및 승강장 양단부의 터널에 적용되는 송풍기를 같이 운전하는 제연모드를 통하여 승강장 화재 및 화재열차 정차시 화재 연기로부터 승객들에게 보다 안전한 대피환경을 제공할 수 있을 것이다.