• Title/Summary/Keyword: Traction inverter

Search Result 153, Processing Time 0.024 seconds

Prospects for the use of Multiphase Inverter-fed Asynchronous Drives in the Field of Traction Systems of Railway Vehicles

  • Brazhnikov, Andrey V.;Belozerov, Ilya R.
    • International Journal of Railway
    • /
    • v.5 no.1
    • /
    • pp.38-47
    • /
    • 2012
  • At present among the most important problems in the field of traction systems of railway vehicles are the following: 1) the minimization of the mass-and-overall dimensions of the drive systems; 2) the increase of the drive systems reliability and obtaining their higher fault-tolerance abilities; 3) the minimization of the motion speed pulsations and its oscillations, etc. The results of the researches received by the authors of this paper show that the use of the multiphase (i.e. having the number of phases more than four) inverter-fed induction motors in these traction systems is the most effective way of solving the above mentioned problems. In this case the motion speed oscillations can be decreased only by the increase of the drive phase number without any change in the inverter control algorithm. In addition, the application of some non-traditional control methods in the multiphase asynchronous traction drive system of a railway vehicle allows to decrease the mass-and-overall dimensions of the system and to improve its reliability and some other technical-and economic characteristics.

The Study of Manufacture and Inertia Load Test of Inverter for Electrical Multiple Unit (전동차용 VVVF 인버터 제작 및 시험)

  • 한영재;김길동;박현준;이은규;한경희
    • Journal of the Korean Society for Railway
    • /
    • v.3 no.1
    • /
    • pp.1-11
    • /
    • 2000
  • In this paper, the IGBT VVVF inverter for 1C4M propulsion system of railway traction is studied. The inverter is consisted of IGBT stacks, a DB unit, and a control unit. The test results of the combined system is given, which shows an excellent performance of the overall system.

  • PDF

An Experimental Study on Traction System of Rubber Tired AGT (고무차륜 경량전철 추진장치 시험)

  • 이병송;정락교;조홍식;정상기;김진선
    • Proceedings of the KSR Conference
    • /
    • 2002.10a
    • /
    • pp.580-584
    • /
    • 2002
  • This paper proposes an experimental study on the traction system of rubber tired AGT (Automated Guideway Transit). IGBT VVVF inverter is developed for 1C2M propulsion system of AGT, and it consists of inverter stack, gate control unit, control unit, and interface unit. The combination test was carried out to prove the performance of inverter, and test results show that the developed inverter is excellent.

  • PDF

A Study on Inverter for DC Traction Regenerative Power Control with Active Power Filter Ability (능동전력필터 기능이 추가된 지하철 회생 전력 제어용 인버터에 관한 연구)

  • Choi, Chang-Youl;Bae, Chang-Hwan;Jang, Su-Jin;Song, Sang-Hun;Won, Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.463-465
    • /
    • 2005
  • This paper proposes a regeneration inverter system, which can regenerate the excessive power form the DC bus line to the AC source for traction systems. The proposed regeneration inverter system for DC traction can reduce harmonics which is a characteristic of the AC current source. The simulation was composed as a prototype model[3.7kW]. Finally, it is shown that the inverter can successfully operate in regeneration mode.

  • PDF

Simulation study of a regenerative inverter for absorption of regenerative energy in a DC traction substation (도시철도직류변전소의 회생전력 흡수를 위한 회생인버터 시뮬레이션)

  • Bae C. H.;Han M. S.;Kim Y. G.;Kwon S. Y.;Park H. J.
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.705-711
    • /
    • 2005
  • In DC traction substation with 12-pulse diode rectifiers, the DC line voltage tends to rise above noload voltage because it can't absorb the regenerative power caused by electric brakes of train. To solve this problem, an IGBT regenerative inverter should be installed and recycles the surplus regenerative power by delivering it. to the supply grid. In this paper, the DC traction substation equipped with a IGBT regenerative inverter is studied using computer simulation. Matlab/simulink is used to simulate the operation of regenerative inverter which injects the regenerative power into the supply grid and stabilizes the DC line voltage. It is confirmed that the high quality regenerative power is delivered to the supply grid thorough computer simulation.

  • PDF

Simulation study of a grid-connected inverter for absorption of regenerative energy in a DC traction substation (도시철도 직류변전소의 회생전력흡수를 위한 계통연계형 인버터 시뮬레이션)

  • Bae, C.H.;Han, M.S.;Jung, H.S.;Kim, Y.K.;Park, H.J.
    • Proceedings of the KIEE Conference
    • /
    • 2005.10c
    • /
    • pp.279-281
    • /
    • 2005
  • In DC traction substation with 12-pulse diode rectifiers, the DC line voltage tends to rise above noload voltage because it can't absorb the regenerative power caused by electric brakes of train. To solve this problem, an IGBT regenerative inverter should be installed and thus recycles the surplus regenerative power by delivering it to the supply grid. In this paper, the DC traction substation equipped with a IGBT regenerative inverter is studied using computer simulation. Matlab/simulink is used to simulate the operation of regenerative inverter which injects the regenerative power into the supply grid and stabilizes the DC line voltage. It is confirmed that the high quality regenerative power is delivered to the supply grid thorough computer simulation.

  • PDF

Improvement of Power Quality in DC Traction Systems Using Statcom

  • Hosseini, Seyed Hossein;Sarhangzadeh, Mitra;Ajami, Ali
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.164-168
    • /
    • 2005
  • In this paper a statcom is developed to improve the power quality in a dc traction system. The proposed statcom can be used as both inverter and active filter. As an active filter, it can compensate harmonic distortion and reactive power and as an inverter, it can recycle regenerative energy caused by decelerating trains. The simulation results are carried out by using PSCAD/EMTDC software.

  • PDF

Direction for Development of Energy Regeneration Device for DC Electric Railway System (DC전철구간의 에너지회생장치 개발 방향)

  • Kim, Yong-Ki;Bae, Chang-Han;Han, Moon-Seob;Yang, Young-Chul;Jang, Su-Jin
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.804-808
    • /
    • 2007
  • when electric traction system used DC 1500V runs on decline of rail road track and slows down, Dc voltage goes beyond regular voltage. In this case extra power is forcibly wasted by resister because rectifier of substation and electric train including power converter and so on are out of order. This paper described a DC electric railway system, which can generate the excessive DC power form DC bus line to AC source in substation for traction system. The proposed regeneration inverter system for DC traction can be used as both an inverter and an active power filter(APF). As a regeneration inverter mode, it can recycle regenerative energy caused by decelerating tractions and as an active power filter mode, it can compensate for harmonic distortion produced by the rectifier substation. In addition, electric traction system products harmonic current and voltage distortion and reactive power because power converter is used so regeneration inverter normally runs such as active power filter(APF) for improving power quality. From the viewpoint of both power capacity and switching losses, the system is designed on the basis of three phase PWM inverters and composed of parallel inverters, output transformers, and an LCL filter.

  • PDF

Acceleration Life Prediction of the Capacitor on a Traction Inverter for a High-Speed Train (고속철도차량용 견인 인버터 커패시터의 가속수명 예측)

  • Maeng, Heeyoung;Jung, Si-Kyo
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.24 no.6
    • /
    • pp.653-659
    • /
    • 2015
  • The aim of this study is to develop a technique for the accelerated life test of the capacitor in a propulsion control device of a traction inverter used for a high-speed train. Using this technique, the accelerated life test can possibly estimate the life cycle of a capacitor under various temperature conditions and irregularly applied voltage. The accelerated life test is conducted for the capacitor of the traction inverter. The common proceedings of this test are selection of failure mechanism, determination of accelerated stress, range determination of the accelerated stress, determination of the test condition, and distribution and determination of the sample. From this result, the continuous applied voltage was not considered for the acceleration factors anymore. Therefore, the final result having an acceleration factor of 9.4 (= 13,626/1,445) was observed. Furthermore, the life-shortening acceleration effect for the irregular applied voltage condition can be applied to various situations.

A study of regenerative inverter system with capability of harmonic reduction (고조파 저감 능력을 가진 회생용 인버터 시스템 연구)

  • Choi, Chang-Youl;Bae, Chang-Hwan;Jang, Su-Jin;Song, Sang-Hun;Won, Cung-Yeun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.443-448
    • /
    • 2005
  • This paper proposed a regeneration inverter system, which can regenerate the excessive power form dc bus line to ac source for traction system. The proposed regeneration inverter system for dc traction can reduce harmonics which are include to ac current source. The regenerative inverter is operated as two modes. As a regeneration inverter mode, it can recycle regenerative energy caused by decelerating tractions and as an active power filter mode, it can compensate for harmonic distortion produced by the rectifier substation. In the paper, a regeneration inverter used PWM DC/AC converter algorithm. And an active power filter used p-q theory. The simulation was composed as a prototype model[3kW]. Simulation results show that two algorithm can be used to real model[100kW]. Finally, the inverter was successfully operated as regeneration mode.

  • PDF