• Title/Summary/Keyword: Traction Control

Search Result 391, Processing Time 0.034 seconds

A Power Regulation and Harmonic Current Elimination Approach for Parallel Multi-Inverter Supplying IPT Systems

  • Mai, Ruikun;Li, Yong;Lu, Liwen;He, Zhengyou
    • Journal of Power Electronics
    • /
    • v.16 no.4
    • /
    • pp.1245-1255
    • /
    • 2016
  • The single resonant inverter is widely employed in typical inductive power transfer (IPT) systems to generate a high-frequency current in the primary side. However, the power capacity of a single resonant inverter is limited by the constraints of power electronic devices and the relevant cost. Consequently, IPT systems fail to meet high-power application requirements, such as those in rail applications. Total harmonic distortion (THD) may also violate the standard electromagnetic interference requirements with phase shift control under light load conditions. A power regulation approach with selective harmonic elimination is proposed on the basis of a parallel multi-inverter to upgrade the power levels of IPT systems and suppress THD under light load conditions by changing the output voltage pulse width and phase shift angle among parallel multi-inverters. The validity of the proposed control approach is verified by using a 1,412.3 W prototype system, which achieves a maximum transfer efficiency of 90.602%. Output power levels can be dramatically improved with the same semiconductor capacity, and distortion can be effectively suppressed under various load conditions.

A Mock Running And Transient State Test of Propulsion VVVF Inverter for Electric Locomotive using A Inertia Load (관성부하를 이용한 전동차 추진용 VVVF 인버터의 모의주행 및 과도상태시험)

  • 정만규;서광덕
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.6
    • /
    • pp.491-499
    • /
    • 1999
  • This paper is on the high perfonnance propulsion IGBT VVVF inverter adopted new technique for railways. To prove the high performance and stabilit~r of traction, running tests are carried out under the simulated condition alike real field. The tests are perfonned on not only a steady states but also a transient states such a as input voltage variation using inertia load equivalent to 160tons train. The vector control technique is a adopted to improve traction for 4 motors. The low switching synchronous PW1\l method based on a space v voltage vector modulation is pro\XlSed as the optimal method for propulsion system railway. The output voltage l is controlled continuously to six step by prolxlsed ovennodu]ation technique without sudden torque variation.

  • PDF

Neuropharmacological screening of the methanolic extract of Hibiscus vitifolius flowers

  • Seethalakshmi, S;Chamundeeswari, D;Rani, S Jamuna;Parvathavardhini, S;Vasantha, J
    • Advances in Traditional Medicine
    • /
    • v.5 no.4
    • /
    • pp.331-335
    • /
    • 2005
  • The methanolic extract of Hibiscus vitifolius flowers (HVE), was evaluated for neurophamacological activities by carrying out rota rod, locomotor activity and traction performance in mice and swim endurance activity in rats in different dosages (10, 30 and 100mg/kg body weight). HVE showed a significant effect on central nervous system by increasing the time taken for rota rod, traction performance and locomotor activity while swimming time was found to be decreased when compared to normal control animals. These results suggest that HVE possess significant anxiolytic and anti depressant activity which may be attributed to the presence of flavonoid in HVE.

Estimation and Measurement of the Traction return current on the electrified Gyeongbu line.

  • Kim, Y.K.;Yang, D.C.;Han, M.S.;Ryu, C.K.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.99.5-99
    • /
    • 2001
  • This study presents a simulation of the traction return current based on $2{\times}25kV$ power supply system in order to determine the impedance bond intensity of impulse type track circuit on the electrified Gyeongbu line. The results of the simulation enables us to measure the precise intensity of catenary current that returns to the substation through KTX (Korean Train Express) operated by $2{\times}25kV$ power supply system with common earth network. The combination of $2{\times}25kV$ and common earth network established on the electrified Gyeongbu line for the first time in Korea. We show that the relationships among the traction return current, earth current, and catenary current, and catenary current can be applied to this line in order to determine the optimal impedance bond intensity ...

  • PDF

Indian Railway Locomotives with IGBT Based Traction Control Converter (IGBT를 이용한 인도 철도시스템)

  • Gopal, Devarajan;Lho, Young-Hwan;Kim, Yoon-Ho
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.1438-1444
    • /
    • 2007
  • Standard Gate Turn Off (GTO) Thyristor drive technology results in inhomogeneous turn-on and turn-off transients which in turn needs costly dv/dt and di/dt snubber circuits. Added to this GTO is bulky in size, needs external cooling, slower switching time etc. The development of high voltage Insulated Gate Bipolar Transistor (IGBT) have given new device advantage in the areas where they compete with conventional GTO technology. Indian Railway has developed first IGBT based traction converter and was commissioned in November 2006. Some of the supremacy of IGBT are smaller in size, no external cooling is required, built in power supply which enhances reliability, lower switching losses which leads to higher efficiency, reduced gate drive, high frequency operation in real time etc. These advantages are highlighted along with IGBT Traction system in operation.

  • PDF

A Study of Traction and Braking of Korean High Speed Rail Vehicle (한국형 고속철도차량의 추진 및 제동 특성에 관한 연구)

  • Kim, Seng-Won;Han, Young-Jae;Kim, Jin-Hwan;Baik, Kwang-Sun;Jeon, Young-Ook;Ae-Sook, Kno
    • Proceedings of the KIEE Conference
    • /
    • 2002.11d
    • /
    • pp.372-374
    • /
    • 2002
  • In this paper, we studied for performance of traction and braking for on-line test and evaluation of korean high speed rail vehicle. It is composed of 6 DAMs(Data Acquisition Modules), 2 monitoring modules and 1 main computer. The software should set and control the hardware of the measuring system, perform the analysis and calculation of measuring data and interface between users and the measuring system. As a result, It has been shown a good performance of traction and braking for test vehicle.

  • PDF

A Study on Inverter for DC Traction Regenerative Power Control with Active Power Filter Ability (능동전력필터 기능이 추가된 지하철 회생 전력 제어용 인버터에 관한 연구)

  • Choi, Chang-Youl;Bae, Chang-Hwan;Jang, Su-Jin;Song, Sang-Hun;Won, Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.463-465
    • /
    • 2005
  • This paper proposes a regeneration inverter system, which can regenerate the excessive power form the DC bus line to the AC source for traction systems. The proposed regeneration inverter system for DC traction can reduce harmonics which is a characteristic of the AC current source. The simulation was composed as a prototype model[3.7kW]. Finally, it is shown that the inverter can successfully operate in regeneration mode.

  • PDF

Comparative Analysis of Magnetic Slot Wedges Design for Increasing Performance of Railway Traction Motor

  • Liu, Huai-Cong;Cho, Sooyoung;Hong, Hyun-Seok;Joo, Kyoung-Jin;Ham, Sang-Hwan;Lee, Ju
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.6
    • /
    • pp.2411-2418
    • /
    • 2017
  • This study focuses on the effects of using open stator slots in an interior permanent magnet traction motor with a magnetic slot wedge design in order to increase the power density at its base speed. In addition, such a configuration reduces the torque ripple under field-weakening conditions. Five different wedge models were selected, each of which was evaluated using a finite element analysis (FEA). Based on the initial model, we designed magnetic slot wedges for maximum back-EMF and minimum cogging torque. In addition, the d-q axis inductance was slightly altered due to the magnetic slot wedges. Finally, we analyzed the performance of a traction machine under field weakening control. Moreover, we have outlined the requirements for an ideal magnetic slot wedge design.

Comparison and Analysis of Return Current Measurement Values on High Speed Line (고속선 귀선전류 측정값 비교 및 분석)

  • Kim, Yong-Kyu;Kim, Ju-Yeop;Oh, Seh-Chan;Baek, Jong-Hyun;Yoon, Yong-Ki;Kwak, Woo-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.5
    • /
    • pp.877-884
    • /
    • 2017
  • A method of common earth, which is proposed by French Railway(SNCF) and is applied to high speed railway, minimizes the effect of the traction return current from tracks so that trackside electric devices can be protected and operation and maintenance staffs are kept out from injury in an electric railway environment. According to it, all the new domestic electric railway lines are replaced from existing individual earth method to the common earth method. In this paper, we analyze the correlation between common earth method and traction return current to prove whether the common earth has surely contributed to minimize the effect of the traction return current. The analysis was done based on the measurement of the traction return current at the domestic high speed railway line.

Regenerative Inverter System for DC Traction Substation with Voltage Drop Compensation Mode (전압강하 보상모드를 갖는 직류 지하철용 회생인버터 시스템)

  • Kim, Jun-Gu;Kim, Jae-Hyung;Cho, Kee-Hyun;Won, Chung-Yuen;Kim, Yong-Ki
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.13 no.3
    • /
    • pp.213-220
    • /
    • 2008
  • In this paper, the regenerative inverter system with voltage drop compensation mode is proposed. When the main rectifier is broken, the DC traction can not be supplied the power from the utility. Actually, the reserve rectifier is mounted in the substation to prevent this accident. In this paper, the voltage drop compensation mode is added to the regenerative inverter system in order to substitute the reserve rectifier. The proposed regenerative inverter system returns the regenerative energy from the DC line voltage to the utility. In addition, the inverter can be compensate the harmonics caused by the power conversion devices used in the DC traction system. We demonstrated the effectiveness of the proposed control algorithm by using computer simulation.