• 제목/요약/키워드: Track detector

검색결과 98건 처리시간 0.025초

5GHZ대 연속 전파 수신 시스템의 개발 (DEVELOPMENT OF THE 5GHZ CONTINUUM RECEIVER SYSTEM)

  • 변도영;최한규;이정원;구본철
    • 천문학논총
    • /
    • 제11권1호
    • /
    • pp.109-123
    • /
    • 1996
  • We have developed a 5GHz continuum receiver system. The receiver is a direct type receiver. In order to reduce the noise due to the fluctuation of the gain in the amplifiers, the system employs the Dicke switching method. We made the 5GHz low-noise amplifier and the bandpass filter. The low-noise amplifier gives ${\sim}35dB$ gain and has ${\sim}210K$ noise temperature. The bandpass filter has a passband between 4.3 and 5.4GHz. We also made switch driver, video amplifiers, phase detector, and integrator. Using a 1.8 meter offset parabolic antenna, we measured the efficiency of the system. Since the antenna does not have a driver to track objects, observations were performed with the antenna fixed. The measured noise temperature of the system is ${\sim}650K$. From the observation of the blank sky, noise level was measured. It was found that the systematic noise(${\sim}0.5K$: peak to peak value) is much larger than the thermal noise. The systematic noise is possibly related to the stability of the DC power supplied to the receiver system. Besides the noise of the system, it was found that the airplanes are the very serious noise sources. We measured the radio flux of the Sun using the developed system. The observed radio flux of the Sun is ${\sim}10^6Jy$, which is close to the known value of the quiet Sun. The test observation of the Sun shows that the angular beam size of the antenna is ${\sim}2.2^{\circ}$.

  • PDF

미세도구를 사용한 미세크기의 우라늄입자 취급기술 (Techniques for Handling Uranium Particles with Micro-tools)

  • 표형열;박용준;손세철;전영신;송병철;지광용;김원호
    • 분석과학
    • /
    • 제13권4호
    • /
    • pp.440-445
    • /
    • 2000
  • 흔적량 입자분석을 위해서는 흔적량의 입자를 다룰수 있는 미세도구가 필요하며 이들을 능숙하게 다룰수 있는 기술 또한 필수적이다. 본 연구에서는 다양한 미세도구들의 제작 및 사용방법을 소개하고 원자력 시설의 먼지시료 중 존재하는 우라늄입자의 동위원소비를 측정하였으며 이 결과로부터 미신고 핵활동 시설에서 사용한 우라늄의 종류를 알아 낼 수 있는 기술의 가능성을 확인하였다. 원자력 시설내의 오염가능 지역에서 기기의 표면 또는 바닥을 여과지로 문질러 시료를 채취하였고 먼지 중 존재하는 흔적량의 우라늄입자는 고체트랙 검출기를 이용하여 참아내었으며, 찾은 미세크기의 우라늄 입자는 미세도구를 사용하여 절단 분리한 후 TIMS의 필라멘트로 옮겨서 우라늄입자의 동위원소 비를 측정하였다.

  • PDF

Monte Carlo Calculation for Production Cross-Sections of Projectile's Isotopes from Therapeutic Carbon and Helium Ion Beams in Different Materials

  • Quazi Muhammad Rashed Nizam;Asif Ahmed;Iftekhar Ahmed
    • Journal of Radiation Protection and Research
    • /
    • 제48권4호
    • /
    • pp.204-212
    • /
    • 2023
  • Background: Isotopes of the projectile may be produced along the beam path during the irradiation of a target by a heavy ion due to inelastic interactions with the media. This study analyzed the production cross-section of carbon (C) and Helium (He) projectile's isotopes resulting from the interactions of these beams with different materials along the beam path. Materials and Methods: In this study, we transport C and He ion beams through different materials. This transportation was made by the Monte Carlo simulation. Particle and Heavy Ion Transport code System (PHITS) has been used for this calculation. Results and Discussion: It has been found that 10C, 11C, and 13C from the 12C ion beam and 3He from the 4He ion beam are significant projectile's isotopes that have higher flux than other isotopes of these projectiles. The 4He ion beam has a higher projectile's isotope production cross-section along the beam path, which adds more impurities to the beam than the 12C ion beam. These projectile's isotopes from both the 12C and 4He ion beams have higher production cross-sections in hydrogenous materials like water or polyethylene. Conclusion: It is important to distinguish these projectile's isotopes from the primary beam particles to obtain a precise and accurate cross-section result by minimizing the error during measurement with a nuclear track detector. This study will show the trend of the production probability of projectile's isotopes for these ion beams.

Structural Behavior of Mixed $LiMn_2O_4-LiNi_{1/3}Co_{1/3}Mn_{1/3}O_2$ Cathode in Li-ion Cells during Electrochemical Cycling

  • 윤원섭;이상우
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2011년도 춘계학술발표대회
    • /
    • pp.5-5
    • /
    • 2011
  • The research and development of hybrid electric vehicle (HEV), plug-in hybrid electric vehicle (PHEV) and electric vehicle (EV) are intensified due to the energy crisis and environmental concerns. In order to meet the challenging requirements of powering HEV, PHEV and EV, the current lithium battery technology needs to be significantly improved in terms of the cost, safety, power and energy density, as well as the calendar and cycle life. One new technology being developed is the utilization of composite cathode by mixing two different types of insertion compounds [e.g., spinel $LiMn_2O_4$ and layered $LiMO_2$ (M=Ni, Co, and Mn)]. Recently, some studies on mixing two different types of cathode materials to make a composite cathode have been reported, which were aimed at reducing cost and improving self-discharge. Numata et al. reported that when stored in a sealed can together with electrolyte at $80^{\circ}C$ for 10 days, the concentrations of both HF and $Mn^{2+}$ were lower in the can containing $LiMn_2O_4$ blended with $LiNi_{0.8}Co_{0.2}O_2$ than that containing $LiMn_2O_4$ only. That reports clearly showed that this blending technique can prevent the decline in capacity caused by cycling or storage at elevated temperatures. However, not much work has been reported on the charge-discharge characteristics and related structural phase transitions for these composite cathodes. In this presentation, we will report our in situ x-ray diffraction studies on this mixed composite cathode material during charge-discharge cycling. The mixed cathodes were incorporated into in situ XRD cells with a Li foil anode, a Celgard separator, and a 1M $LiPF_6$ electrolyte in a 1 : 1 EC : DMC solvent (LP 30 from EM Industries, Inc.). For in situ XRD cell, Mylar windows were used as has been described in detail elsewhere. All of these in situ XRD spectra were collected on beam line X18A at National Synchrotron Light Source (NSLS) at Brookhaven National Laboratory using two different detectors. One is a conventional scintillation detector with data collection at 0.02 degree in two theta angle for each step. The other is a wide angle position sensitive detector (PSD). The wavelengths used were 1.1950 ${\AA}$ for the scintillation detector and 0.9999 A for the PSD. The newly installed PSD at beam line X18A of NSLS can collect XRD patterns as short as a few minutes covering $90^{\circ}$ of two theta angles simultaneously with good signal to noise ratio. It significantly reduced the data collection time for each scan, giving us a great advantage in studying the phase transition in real time. The two theta angles of all the XRD spectra presented in this paper have been recalculated and converted to corresponding angles for ${\lambda}=1.54\;{\AA}$, which is the wavelength of conventional x-ray tube source with Cu-$k{\alpha}$ radiation, for easy comparison with data in other literatures. The structural changes of the composite cathode made by mixing spinel $LiMn_2O_4$ and layered $Li-Ni_{1/3}Co_{1/3}Mn_{1/3}O_2$ in 1 : 1 wt% in both Li-half and Li-ion cells during charge/discharge are studied by in situ XRD. During the first charge up to ~5.2 V vs. $Li/Li^+$, the in situ XRD spectra for the composite cathode in the Li-half cell track the structural changes of each component. At the early stage of charge, the lithium extraction takes place in the $LiNi_{1/3}Co_{1/3}Mn_{1/3}O_2$ component only. When the cell voltage reaches at ~4.0 V vs. $Li/Li^+$, lithium extraction from the spinel $LiMn_2O_4$ component starts and becomes the major contributor for the cell capacity due to the higher rate capability of $LiMn_2O_4$. When the voltage passed 4.3 V, the major structural changes are from the $LiNi_{1/3}Co_{1/3}Mn_{1/3}O_2$ component, while the $LiMn_2O_4$ component is almost unchanged. In the Li-ion cell using a MCMB anode and a composite cathode cycled between 2.5 V and 4.2 V, the structural changes are dominated by the spinel $LiMn_2O_4$ component, with much less changes in the layered $LiNi_{1/3}Co_{1/3}Mn_{1/3}O_2$ component, comparing with the Li-half cell results. These results give us valuable information about the structural changes relating to the contributions of each individual component to the cell capacity at certain charge/discharge state, which are helpful in designing and optimizing the composite cathode using spinel- and layered-type materials for Li-ion battery research. More detailed discussion will be presented at the meeting.

  • PDF

XCAT를 이용한 실시간 종양 위치 추적을 위한 비직교 스테레오 엑스선 영상시스템에서의 위치 추정 정확도 분석에 관한 연구 (Analysis on the Positional Accuracy of the Non-orthogonal Two-pair kV Imaging Systems for Real-time Tumor Tracking Using XCAT)

  • 정한성;김영주;오오성;이세호;전호상;이승욱
    • 한국의학물리학회지:의학물리
    • /
    • 제26권3호
    • /
    • pp.143-152
    • /
    • 2015
  • 본 연구에서는 두 개의 치료빔 가속기가 사용되는 구조에서 종양 위치 추적을 하는 두 쌍의 kV 영상시스템의 기하학적 설계 및 종양 위치 추적 정확도 분석을 목표로 하고 있다. 특히, 병변의 위치추적을 위한 수식 및 알고리즘을 수립하였고, 두 쌍의 kV 영상 시스템이 비직교 위치에 놓일 때 검출기 해상도가 종양 위치 추적 오차에 미치는 영향에 대해서 모의실험으로 분석하여 보았다. 병변의 위치추적을 위한 수식 및 알고리즘을 수립하기 위해서 각 엑스선원, 검출기 등의 절대좌표는 동차방정식을 이용하여 설정하였으며, 삼차원 상의 두 직선의 방정식을 통하여 병변의 절대위치를 찾아내도록 하였다. XCAT 프로그램을 이용한 모의실험을 통해서 영상 검출기의 해상도가 미치는 영향을 두 개의 kV 영상시스템의 각도에 따라서 분석하여보았다. XCAT 소프트웨어를 이용하여서 팬텀에 병변 추적을 위한 금속 기점 마커를 삽입하였고, CT projection 프로그램을 이용하여 각 kV 영상시스템의 각도별, 검출기의 해상도별 영상을 획득할 수 있다. 모의실험 결과, 두 kV영상시스템의 각도가 $90^{\circ}$에서 $50^{\circ}$까지는 검출기 해상도가 1.5 mm/pixel보다 고해상도 일 때 약 1 mm 이하의 위치 오차를 보였다. 하지만, 검출기의 해상도가 1.5 mm/pixel 이상으로 나빠질수록 오차가 약 1 mm 이상으로 나타날 뿐만 아니라 각도에 따른 오차의 변동이 컸다. 검출기의 해상도가 개선될 수록 그 각도별 오차의 변동이 줄어들고, $90^{\circ}$에서 가장 적은 오차가 발생 하는 것을 볼 수 있었다. 충분한 해상도의 검출기가 사용된다면 듀얼헤드 겐트리 시스템과 같이 공간적으로 제한된 방사선 치료기기에 두 개의 kV 영상시스템을 예각으로 설치하여도 된다는 결론을 도출할 수 있었다. 본 연구에서 개발한 모의실험 방법론은 병변의 위치, 검출기의 특성, kV 영상 시스템의 기하학적 배치에 따른 종양추적 위치 추적시스템의 정확도를 분석하는 도구로서 유용하게 사용될 수 있을 것이다.

서울지역 지하철역의 라돈농도 분포 특성 (Distribution of $^{222}Rn$ Concentration in Seoul Subway Stations)

  • 전재식;김덕찬
    • 대한환경공학회지
    • /
    • 제28권6호
    • /
    • pp.588-595
    • /
    • 2006
  • 본 연구는 서울지역 지하철역 실내 공기 중 라돈분포를 조사하여 그 발생원을 추적 확인하기 위하여 수행되었다. 1998년부터 2004년까지 232개 역사를 대상으로 알파비적검출기를 사용하여 실내 공기 중 장기라돈을 측정하였으며 지하수중 라돈농도는 알파입자계수법에 의하여 측정하였다. 라돈의 주 발생원을 추적하기 위하여 8개 역사를 선정하여 각 역사의 승강장과 인접터널에 대한 공기 중 라돈농도를 조사하였다. 전체역사에 대한 라돈농도 분석결과 기하평균 및 산술평균은 각각 $1.40{\pm}1.94pCi/L,\;1.65{\pm}1.07$였으며, 승강장과 매표소의 기하평균은 각각 $1.54{\pm}1.96pCi/L,\;1.23{\pm}1.88pCi/L$로 승강장에서의 라돈농도가 매표소의 농도보다 더 높게 나타났다. 지질구조와 지하역사의 라돈분포는 밀접한 상관성을 보였으며 터널내부와 지하수중의 라돈농도는 역사 승강장의 라돈농도에 크게 영향을 미치고 있었다. 또한 역사의 승강장이 위치하고 있는 깊이 정도에 따라 라돈농도의 차이를 보였다(p<0.05).

열차 차축검지 신뢰성 향상을 위한 근접센서 방식 Axle Counter 적용 연구 (A Study of the Apply Proximity Sensor for Improved Reliability Axle Detection)

  • 박재영;최진우
    • 한국산학기술학회논문지
    • /
    • 제16권8호
    • /
    • pp.5534-5540
    • /
    • 2015
  • 철도 신호제어시스템에서 열차의 위치 및 점유 유무를 검지하기 위하여 궤도회로 이외에 axle counter적용 사례가 증가하고 있는 추세이다. 이에 본 연구에서는 열차검지 및 차축계수의 신뢰성을 높이기 위해 axle counter의 센서 방식을 지자기 센서 방식과 근접센서 방식을 비교하였으며, 그에 따른 차이점과 결과를 제시하였다. 또한, 정확한 차축검지를 위한 센서부의 취부조건 등을 고려한 설치에 대해 현장 경험을 기반으로 적용된 결과를 제시한다. 본 연구에서는 차축검지의 신뢰성 향상을 위해 센서의 위상차를 판단할 수 있도록 설계 변경한 결과 차축검지 기능뿐만 아니라 다양한 기능까지(열차의 방향검지, 열차속도검지 등) 수행할 수 있는 확장성을 확보하였다. 또한 열차의 종별, 무게 등의 특성에 종속되지 않았으며, 자체적으로 제작한 차축검지를 위한 모의차축 이송장치와 Test Bed를 구축하여 Lab. 테스트를 수행한 결과 350km/h의 속도에서도 차축 검지의 누락이 발생하지 않았음을 확인하였다. 이를 통해 열차의 검지뿐만 아니라 통과하는 열차의 속도와 편성 수, 선로전환기 통과 시 철사쇄정 조건 그리고 건널목 장치에도 적용할 수 있는 기반을 마련하였으며, 향후 철도 신호제어 시스템 전반에 확대 적용하게 되면 열차안전운행에 많은 기여를 할 것으로 판단된다.

Imaging Performance Analysis of an EO/IR Dual Band Airborne Camera

  • Lee, Jun-Ho;Jung, Yong-Suk;Ryoo, Seung-Yeol;Kim, Young-Ju;Park, Byong-Ug;Kim, Hyun-Jung;Youn, Sung-Kie;Park, Kwang-Woo;Lee, Haeng-Bok
    • Journal of the Optical Society of Korea
    • /
    • 제15권2호
    • /
    • pp.174-181
    • /
    • 2011
  • An airborne sensor is developed for remote sensing on an aerial vehicle (UV). The sensor is an optical payload for an eletro-optical/infrared (EO/IR) dual band camera that combines visible and IR imaging capabilities in a compact and lightweight package. It adopts a Ritchey-Chr$\'{e}$tien telescope for the common front end optics with several relay optics that divide and deliver EO and IR bands to a charge-coupled-device (CCD) and an IR detector, respectively. The EO/IR camera for dual bands is mounted on a two-axis gimbal that provides stabilized imaging and precision pointing in both the along and cross-track directions. We first investigate the mechanical deformations, displacements and stress of the EO/IR camera through finite element analysis (FEA) for five cases: three gravitational effects and two thermal conditions. For investigating gravitational effects, one gravitational acceleration (1 g) is given along each of the +x, +y and +z directions. The two thermal conditions are the overall temperature change to $30^{\circ}C$ from $20^{\circ}C$ and the temperature gradient across the primary mirror pupil from $-5^{\circ}C$ to $+5^{\circ}C$. Optical performance, represented by the modulation transfer function (MTF), is then predicted by integrating the FEA results into optics design/analysis software. This analysis shows the IR channel can sustain imaging performance as good as designed, i.e., MTF 38% at 13 line-pairs-per-mm (lpm), with refocus capability. Similarly, the EO channel can keep the designed performance (MTF 73% at 27.3 lpm) except in the case of the overall temperature change, in which the EO channel experiences slight performance degradation (MTF 16% drop) for $20^{\circ}C$ overall temperate change.