• 제목/요약/키워드: Tracer-test

검색결과 183건 처리시간 0.022초

Application of single-well push-drift-pull tests using dual tracers (SF6 and salt) for designing CO2 leakage monitoring network at the environmental impact test site in Korea

  • Kim, Hong-Hyun;Lee, Seong-Sun;Ha, Seung-Wook;Lee, Kang-Kun
    • Geosciences Journal
    • /
    • 제22권6호
    • /
    • pp.1041-1052
    • /
    • 2018
  • A single-well push-drift-pull tracer test using two different tracers ($SF_6$ and salt) was performed at the Environmental Impact Test (EIT) site to determine suitable locations for monitoring wells and arrange them prior to artificial $CO_2$ injection and leak tests. Local-scale estimates of hydraulic properties (linear groundwater velocity and effective porosity) were obtained at the study site by the tracer test with two tracers. The mass recovery percentage of the volatile tracer ($SF_6$) was lower than that of the non-volatile tracer (salt) and increased drift time may make degassing of $SF_6$ intensified. The $CO_2$ leakage monitoring results for both unsaturated and saturated zones suggest that the $CO_2$ monitoring points should be located near points at which a high concentration gradient is expected. Based on the estimated hydraulic properties and tracer mass recovery rates, an optimal $CO_2$ monitoring network including boreholes for monitoring the unsaturated zone was constructed at the study site.

지하수 검층을 위한 새로운 유전율 추적자 시험법의 개발 (A development of new dielectric tracer test method for groundwater logging: laboratory soil column test)

  • 김만일;김형수;정교철
    • 지질공학
    • /
    • 제14권3호
    • /
    • pp.301-311
    • /
    • 2004
  • 다공질매질을 구성하고 있는 다양한 매질들의 전기적 특성 중의 하나인 유전율상수를 이용하여 지하수 유동 및 매질의 구조를 파악하기 위한 새로운 유전율추적자시험법(dielectric tracer test method)을 본 연구에서 제안하였다. 추적자물질로는 비중이 물과 동일한 에탄올혼합액체(ethanol mixing liquid, EML)를 제작하였으며, 각기 다른 공극률을 갖는 포화 표준사 및 강모래 층에 대해 매질의 유전율상수를 측정할 수 있는 FDR system및 측정센서를 적용해 추적자시험을 실시하였다. 또한 이들의 결과와 비교하기 위하여 추적자물질인 염분농도 $3\%$를 갖는 염분수용액의 농도 변화를 electro multi-meter로 측정하여 비교 검토하였다. 두 시험결과에서 EML추적자시험의 경우, 각각의 포화 흙칼럼에서의 EML 농도변화를 명확히 확인할 수 있었으나, 염분수용액을 적용한 시험에서는 이들이 지속적으로 칼럼 내 하단부로 침전되어 염분농도 변화에 의한 물의 침투 이동은 확인할 수 없었다. 이는 염분수용액의 비중이 물보다 무겁기 때문에 포화토 내 물의 이동 속도에 비례하여 지속적으로 하단부로 침전이 이루어지는 것을 알 수 있었다. 따라서 본 연구에서는 물의 비중과 동일한 EML 추적자물질과 이들의 유전율상수 변화를 측정할 수 있는 FDR system을 적용하여 유전율추적자시험의 적용 가능성을 실내추적자시험을 통하여 확인하였다.

침전지 추적자 실험을 위한 Dispersion Number의 적용 (Application of Dispersion Number for Analysis of Tracer test in Sedimentation Basin)

  • 김영일;박노석;정남정;김성수;배병욱
    • 상하수도학회지
    • /
    • 제21권2호
    • /
    • pp.187-193
    • /
    • 2007
  • Reynolds and Froude numbers, along with tracer tests, have been widely used to estimate hydrodynamics in full-scale horizontal sedimentation basin in water treatment plants (WTPs). In spite of this, the former numbers do not reflect actual operating conditions, instead most often being based on the dimensions of the structures. The index and graphic analyses most often used were found to be too subjective to accurately analyze tracer test results. In order to overcome these limitations, dispersion number was applied for analysis of tracer test results. Tracer tests were conducted in eight full-scale sedimentation basins in six WTPs, and then analyzed by index and graphic analyses as well as by dispersion number. The dispersion number was more useful as an indicator of the hydrodynamic behavior in the basin. It was also found that as dispersion number decreased, flow approached the ideal for plug flow in which case, higher sedimentation efficiency could be expected.

정수지 내 추적자 실험과 CFD(전산유체역학)의 상관관계 분석 (Case study comparisons of computational fluid dynamics modeling versus tracer test to evaluate the hydraulic efficiency of clearwell)

  • 김태균;최영준;조영만
    • 상하수도학회지
    • /
    • 제25권5호
    • /
    • pp.635-642
    • /
    • 2011
  • Hydraulic efficiency was a vital component in evaluating the disinfection capability of clearwell. Current practice evaluates these system based on the tracer test only. In this paper, CFD(Computational Fluid Dynamics) was applied on the clearwell for alternating or supplementing the tracer test. The baffle factor derived from the CFD modeling closely matched the values obtained from full scale tracer testing. And, for suggesting proper numerical model in clearwell; the turbulence model, discretization scheme, convergence criteria were investigated through separate simulation runs. The model validation was conducted by comparing the simulated data with experimental data. In the turbulence model, the realizable ${\kappa}-{\varepsilon}$ model and the standard ${\kappa}-{\varepsilon}$ model were found to be more appropriate than RNG ${\kappa}-{\varepsilon}$ model. The residuals of convergence criteria should be used as not $10^{-3}$ but $10^{-4}$ or $10^{-5}$. In discretization scheme, the difference of simulated values in 1st, 2nd, 3rd upwind scheme was found to be insignificant. Moreover, the result of this study suggest that CFD modeling can be a reliable alternative to tracer testing for evaluating the hydraulic efficiency.

Feasibility of Streaming Potential Signal on Estimation of Solute Transport Characteristics

  • Kabir, Mohammad Lutful;Ji, Sung- Hoon;Lee, Jin-Yong;Koh, Yong- Kwon
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제20권2호
    • /
    • pp.41-46
    • /
    • 2015
  • The drag of the excess charge in an electrical double layer at the solid fluid interface due to water flow induces the streaming current, i.e., the streaming potential (SP). Here we introduce a sandbox experiment to study this hydroelectric coupling in case of a tracer test. An acrylic tank was filled up with homogeneous sand as a sand aquifer, and the upstream and downstream reservoirs were connected to the sand aquifer to control the hydraulic gradient. Under a steady-state water flow condition, a tracer test was performed in the sandbox with the help of peristaltic pump, and tracer samples were collected from the same interval of five screened wells in the sandbox. During the tracer test, SP signals resulting from the distribution of 20 nonpolarizable electrodes were measured at the top of the tank by a multichannel meter. The results showed that there were changes in the observed SP after injection of tracer, which indicated that the SP was likely to be related to the solute transport.

Test of Stokes-Einstein Formula for a Tracer in a Mesoscopic Solvent by Molecular Dynamics Simulation

  • Lee, Song Hi
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권2호
    • /
    • pp.574-578
    • /
    • 2013
  • In this work, the friction and diffusion coefficients of a tracer in a mesoscopic solvent are evaluated as a function of the tracer size by a hybrid molecular dynamics simulation where solute molecules evolve by Newton's equations of motion but the solvent evolves through the multi-particle collision dynamics. The friction coefficient is shown to scale linearly with the tracer size for larger tracers in accord with predictions of hydrodynamic theories. The diffusion coefficient of tracer is found to be inversely proportional to tracer size. The behavior of Stokes-Einstein formula is validated as a function of tracer size.

시간 모멘트식을 이용한 상분할추적자의 해석 (Partitioning Tracer Analysis with Temporal Moments Equations)

  • 조종수
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제16권3호
    • /
    • pp.3-9
    • /
    • 2011
  • Partitioning tracers have been used with non-partitioning, inert tracer such Br, for detection, estimation, and monitoring of remediation performance of the subsurface contaminated with nonaqueous phase liquids (NAPLs). Various partitioning tracers with different partition coefficients between aqueous and nonaqueous phase liquids can be used to determine the hydraulic conductivity, dispersivity, and residual mass of NAPLs in the subsurface soil matrices. Temporal moment-generating equations were used to analyze the field pilot-scale test results. The pilot-scale tests included conservative tracer tests and partitioning tracer tests. Analyses of nonaqueous phase liquid distribution and characteristics of groundwater bearing soil media were performed.

창원지역 화강암의 수리분산 특성

  • 김무진;함세영;황한석;김문수
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2001년도 총회 및 춘계학술발표회
    • /
    • pp.187-190
    • /
    • 2001
  • This study is concerned with the hydrodispersive characteristics of granite in Changwon area. A single-well injection/recovery tracer test was conducted to determine longitudinal dispersivity of the granite, using sodium chloride tracer The dispersivity values obtained from the injection phase are 0.48 m (for between PW-1 and OW-3) and 0.72 m (for between PW-1 and OW-4). That obtained from the recovery phase is 0.68 m. The result of the tracer test indicates that the anisotropy and heterogeneity of the granite and the direction of flow.

  • PDF

단열 및 다공질 대수층에서의 추적자 시험연구 (A Comparative Study of Tracer Tests in Fractured and Porous Media)

  • 이진용;이지훈;김용철;천전용;이민효;이강근
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2001년도 총회 및 춘계학술발표회
    • /
    • pp.132-135
    • /
    • 2001
  • To understand and compare tracer transport in fractured and porous media. multiple tracer tests were conducted in Wonju and Uiwang sites. The target media were fractured in Wonju site and porous in Uiwang site. It was known that groundwater flow for the two hydrogeologic systems could be represented using a EPM approach. However, the tracer transport in the two aquifer systems was greatly different. In this study, we analyzed the different tracer transport behavior in the two systems, from which our understanding of the tracer dispersion was greatly enhanced. we used bromide and chloride as tracers.

  • PDF

현장 규모 biobarrier의 수리학적 특성과 기초 설계

  • 최영화;오재일;왕수균;배범한
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2003년도 추계학술발표회
    • /
    • pp.426-430
    • /
    • 2003
  • Subsurface biobarrier technology has potential applications to contain contaminated groundwater and/or to degrade toxic pollutants in groundwater. Effective biobarrier formation is need to assess of hydrogeologic characteristics and to conduct practical operation strategies and design based on this prior to design biobarrier. Thus, in this study, we examined hydrogeologic characteristics in biobarrier construction site. Hydraulic conductivities which calculated from slug test data have shown difference with each well as 1.20$\times$10$^{-3}$ -6.00$\times$10$^{-5}$ cm/sec. Tracer test is a method in which concentration of tracer solution during withdrawal in each well by vacuum extraction system is measured with time. Tracer solution was continuously injected by constant head tank. Measured tracer concentration versus time data were fitted to analytical solution of convection dispersion equation (CDE). The fitting data of CDE to the measured data at each extraction well yielded were 0.61cm/min(pore velocity), 5.38$\textrm{cm}^2$/min(dispersion coefficient) for discharge rate of 0.47 1/min and 1.75cm/min(pore velocity), 36.34$\textrm{cm}^2$/min(dispersion coefficient) for discharge rate of 0.93 1/min. As a result, we acquired fundamental parameters which need to design biobarrier and operation strategies.

  • PDF