• 제목/요약/키워드: Toxic Estimation

검색결과 64건 처리시간 0.028초

독성물질 누출의 강도 산정 방법에 관한 비교 연구 (A Comparative Study on the Method of Consequence Estimation for Release of Toxicant Substances)

  • 김윤화;백종배;고재욱
    • 한국안전학회지
    • /
    • 제9권1호
    • /
    • pp.89-94
    • /
    • 1994
  • Two methods, the numerical method of CPQRA and the manual method of IAEA, were used to estimate the effect distance from release and dispersion of toxic materials. The Gaussian plume model which has a weather stability class D with wind velocity of 5m/s was applied to calculate dispersion of toxic materials. Also, probit function were employed to evaluate the human fatality as a result of exposure to toxic gases. Furthermore, concentration of toxic materials corresponding to LC$_{50}$ for 30 min could be determined by setting Pr as 5.0 and solving the probit function. Calculations were conducted by employing chlorine and ammonia as toxic materials because they are not only most commonly used In chemical plants but also very harmful to humans. Calculated results by employing toxic materials indicated that the effect distance from the CPQRA method was between the minimum and maximum distance from the method proposed by IAEA.A.

  • PDF

고압 독성가스시설에서 API-581 적용성 및 사고결과 분석방법에 관한 연구 (A Study on Applicability of API-581 and Methodology for Consequence Analysis in High-Pressure Toxic Gas Facilities)

  • 장서일;김영란;박교식;신동일;김태옥
    • 한국가스학회지
    • /
    • 제18권4호
    • /
    • pp.76-85
    • /
    • 2014
  • 본 연구는 독성가스 사고의 주요 원인의 하나인 부식에 대해 고압 독성가스시설을 대상으로 필요한 안전기술을 정립하기 위하여 미국석유학회에서 개발한 API-581 절차를 채택하여 사고결과 분석방법에 대한 적용성을 검토하고, 이를 바탕으로 사고결과 분석방법을 제시하였다. 고압 독성가스시설에서 API-581의 8단계 사고결과 분석절차에 따라 단계별 적용성을 검토한 결과, 고압 독성가스시설에 적용할 사고결과 분석방법은 총 6단계로 단순화 할 수 있었다. 즉, Step 1(대표물질 결정), Step 5(누출유형 결정), Step 6(유체상 결정)과 Step 8(사고 피해영역 산출)은 적용하지 않고, Step 3(누출량 산출)은 inventory group 개념만 적용하며, Step 4(누출속도 산출)는 기체 누출속도만을 적용하고, Step 2(누출공 크기 선정)와 Step 7(완화시스템 등급 결정)은 전부 적용한다. 이때, Step 5와 Step 8은 일반적으로 적용이 가능한 CCPS 방법을 대안적인 방법으로 채택한다.

기하학적 변수에 의한 다이옥신의 독성 예측 (Estimation of Biological Action of Dioxins by Some Geometric Descriptors)

  • Hwang, Inchul
    • Environmental Analysis Health and Toxicology
    • /
    • 제14권3호
    • /
    • pp.103-111
    • /
    • 1999
  • To effectively predict the lipophilicity, the aryl hydrocarbon receptor (AhR) affinity, and TEF (Toxic equivalency factor) of dioxins by geometrical descriptors, the multiple linear regression methods with the forward selection and backward elimination were employed with statistical validity. The lipophilicity, the Ah receptor binding affinity, and the toxic equivalency factor of dioxins could be predicted using some geometrical descriptors.

  • PDF

Risk Assessment for Noncarcinogenic Chemical Effects

  • Kodell Ralph L.
    • 대한예방의학회:학술대회논문집
    • /
    • 대한예방의학회 1994년도 교수 연수회(환경)
    • /
    • pp.412-415
    • /
    • 1994
  • The fundamental assumption that thresholds exist for noncarcinogenic toxic effects of chemicals is reviewed; this assumption forms the basis for the no-observed-effect level/ safety-factor (NOEL/SF) approach to risk assessment for such effects. The origin and evolution of the NOEL/SF approach are traced, and its limitations are discussed. The recently proposed use of dose-response modeling to estimate a benchmark dose as a replacement for the NOEL is explained. The possibility of expanding dose-response modeling of non carcinogenic effects to include the estimation of assumed thresholds is discussed. A new method for conversion of quantitative toxic responses to a probability scale for risk assessment via dose-response modeling is outlined.

  • PDF

독성물질 사용.저장시설에 대한 개인적 위험성 산정에 관한 연구 (A Study on the Individual and Societal Risk Estimation for the Use and Storage Facility with Toxic Materials)

  • 김성빈;김윤화;이철;엄성인;고재욱;백종배
    • 한국안전학회지
    • /
    • 제12권1호
    • /
    • pp.51-59
    • /
    • 1997
  • These days leakage incidents of toxic materials cause serious effects on the nearby residents as well as the workers around the accidents accompanying massive material losses and human damages through widening influential areas. The risk measure through adequate quantitative analysis as well as the qualitative analysis of the leakage incidents of toxic materials becomes an urgent issue. The damage of the leakage incident on the surrounding area of the dangerous toxic material facilities was calculated quantitatively by adopting several models in this research. First, the calculations of the leakage velocity from the factories were performed by using source model for the assessment of the influential area, and the damages on the nearly residents were calculated by using the dispersion model and the effort model. The probability of the Incidents was computed based on "The manual for classification and priorization of major incidents" published by IAEA( International Atomic Energy Agency ). Above calculated damage area and incident probability were further adopted in this study to induce the individual and societal risk, quantitatively. The calculated data of the real Incident of the toxic material leakage showed reasonable agreements to the actual damage of the incidents, which showed a validity of this study. The result of this study might be a helpful measure for predicting damages and preparing safety systems for similar kinds of incidents.incidents.

  • PDF

다중 센서들을 이용한 다양한 화재 상황의 위험도 추정 시스템 개발 (Implementation of Fire Risk Estimation System for various Fire Situations using Multiple Sensors)

  • 이광재;이연성
    • 센서학회지
    • /
    • 제25권6호
    • /
    • pp.394-398
    • /
    • 2016
  • In this paper, a fire detection system based on quantitative risk estimation is presented. Multiple sensors are used to build a comprehensive indicator that represents the risk of fire quantitatively. The proposed fire risk estimation method consists of two stages which determines the occurrence of fire and estimates the toxicity of the surveillance area. In the first stage, fire is reliably detected under diverse fire scenarios. The risk of fire is estimated in the second stage. Applying Purser's Fractional Effective Dose (FED) model which quantitates harmfulness of toxic gases, the risk of the surveillance area and evacuation time are calculated. A fire experiment conducted using four different types of combustion materials for the verification of the system resulted in a maximum error rate of 12.5%. By using FED calculation and risk estimation methods, the proposed system can detect various signs of fire faster than conventional systems.

연소조건에서 중금속 염화물의 휘발 및 유독성 제어 (Volatilization and Toxicity Control of Heavy Metal Chlorides under Combustion Conditions)

  • 서용칠
    • 한국안전학회지
    • /
    • 제8권4호
    • /
    • pp.175-182
    • /
    • 1993
  • Volatilization of toxic heavy metals, especially, metal chlorides at elevated temperatures in oxidation conditions was observed using a thermogravimetric furnace since such metal chlorides used to be a cause for the disease of industrial workers by their toxicity and high volatile extent. Most of tested metal chloride compounds were evaporated or decomposed into gas phase at elevated temperatures ranged from 200~90$0^{\circ}C$, while CrCl$_3$ and NiC1$_2$became stable with converting into oxide forms. A kinetic model for evaporation/condensation could predict maximum evaporation flux and the calculated values were compared with real evaporation flux. The ratio of two fluxes could be explained as the fraction of impinging gas molecules to the condensing surface( $\alpha$ ) and obtained in the range of 10$^{-3}$ ~10$^{-9}$ for the experimented toxic heavy metal chlorides. This ratio might be used to define the volatile extent or toxicity of such toxic metal compounds. The schemes to avoid volatilization of toxic heavy metals Into the atmosphere were suggested as follows ; 1 ) controlling the compositions of metals and Chlorine produced substances( such as PVC ) in the treated materials using a reverse estimation from regulatory limit and characteristics of a processing facility, 2) Installation of wet type devices such as a scrubber for condensing the metal compounds.

  • PDF

수질유해물질 배출허용기준 설정에 따른 배출시설 비용영향 분석사례 연구: 1,4-Dichlorobenzene을 중심으로 (Case Study of Cost Effect Analysis for Toxic Compounds to Developing Effluent Limitation Standards : Focus on 1,4-Dichlorobenzene)

  • 김경진;김원기;허진;김광인;김재훈;김상훈;염익태
    • 한국물환경학회지
    • /
    • 제26권4호
    • /
    • pp.557-565
    • /
    • 2010
  • Recently, regulations on toxic compounds in aquatic environment have been strengthened in korea due to the increasing public awareness of the water quality. Typically, these regulations include introduction of emerging toxic compounds and stricter effluent limitations for the already regulated compounds. However, too strict regulations may cause excessive burden on the industry. Therefore it is also important to assess the economic impacts when the new effluent limitation guidelines are introduced. The estimation of the additional cost for the wastewater dischargers to meet the new guidelines are based on the selected treatment technology to handle the hazardous substances and the regulatory levels for effluent limitations. To explore the procedures for cost estimation in enforcing new effluent limitations, a case study was performed specially for 1,4-dichlorobenzene. The pollutants of concern are surveyed for different industrial categories and various treatment technologies. For a given pollutant, the general performances of the treatment technologies are surveyed and a representative technology is selected. For a given technology, the capital cost and annual Operation and Maintenance (O&M) cost was calculated. The calculation of baseline costs to operate ordinary treatment technologies is also important. The ratio between the cost for introducing new treatment process and the baseline cost required for conventional technology was used to evaluate the economic impact on the industry. For 1,4-dichlorobenzene, steam stripping and activated carbon processes were selected as the specific treatment technologies. The cost effects to the regulation of the compound were found to be 6.4% and 14.5% increase in capital cost and O&M cost, respectively, at the flow rate over $2,000m^3/d$ for the categories of synthetic resin and other plastics manufacturing industry. For the case of petrochemical basic compounds manufacturing industry, the cost increases were 5.8% and 12.4%, respectively. It was suggested that cost effect analysis to evaluate the economic impacts of new effluent limitations on the industry is crucial to establish more balanced and reasonable effluent limitations to manage the industrial wastewater containing emerging toxic compounds in the wastewater.

파스콘 트로프의 연기유독성에 관한 연구 (A Study on the Toxic Gases and Smoke Hazard of PASCON Trough)

  • 이창우;현성호;최돈묵
    • 한국화재소방학회논문지
    • /
    • 제20권2호
    • /
    • pp.1-7
    • /
    • 2006
  • 본 연구는 파스콘 트로프의 화재시 발생되는 연기의 유독성 평가를 위해 KS F 2271에 의한 연기유해성 시험 및 NES 713방법에 의해 연소가스를 분석하고, 독성지수를 확인해 봄으로서 연소시 인체에 미치는 영향을 간접적으로 확인해 보고자 한다. 실험결과 파스콘 트로프는 KS F 2271인 건축물의 내장재료 및 구조의 난연성 시험기준에 적합한 것을 확인하였다. NES 713 방법에 의한 파스콘 제품에서 발생하는 연소가스는 이산화탄소와 일산화탄소가 전부임을 알 수 있으며, 연소가스의 독성지수는 0.944로 나타났다. 이러한 수치는 제품의 연소시 발생되는 연소가스를 30분 이상 노출되어야 위험한 농도에 이룰 수 있다는 것을 의미한다. 난연성능 요구시 연기유독성 평가나 연기의 발생량을 규제하지 않고 있는 국내의 실정에 비추어 볼 때 파스콘 제품의 연소가스 독성지수는 비교적 낮은 수치이다.