• Title/Summary/Keyword: Tower data

Search Result 438, Processing Time 0.024 seconds

Off-Design Performance Analysis of a Counterflow-Type Cooling Tower (대향류형 냉각탑의 탈설계 성능해석)

  • 신지영;손영석;한동원
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.3
    • /
    • pp.191-198
    • /
    • 2002
  • Cooling tower design procedure was set up using conventional Merkel theory, The design data could be different depending on the characteristic curve that the engineer chose. It reveals that the consistent and reasonable criteria are required based on the exact information of the cooling tower Performance. In this study, an off-design performance analysis program for a counterflow-type cooling tower was developed and verified by comparing with experimental data. Also, the off-design performance with various operating conditions was analyzed.

Development of Expert System for Tower Cranes

  • Kim, Ki-sung;Kang, Dong-gil;Hong, Ki-sup
    • Journal of Ship and Ocean Technology
    • /
    • v.3 no.2
    • /
    • pp.27-48
    • /
    • 1999
  • The paper is concerned with application to develop the expert system, which structural analysis and design process for tower cranes. The system is organized into three groups. One is pre-processor for creating input data files, another is `model former' which combines knowledge-base with inference engine for automatic generating structural analysis models, a third is application group for final analysis checks. In this study, geometric subroutine of `model former' designates node positions, nodes, elements numbers and element types. Load data subroutine computes weight of tower crane and device, slewing force, cargo load, wind force form rules or equations in knowledge-base. Also, Property and boundary subroutine applies element properties and boundary conditions to suitable elements and nodes. Design and analysis expert system for tower crane integrates these subroutine, `model former' and pre-processor. RBR(Rule-Base Reasoning) was adopted for a reasoning strategy of this expert system. And this expert system can produce structural analysis model and data, which can be used in ordinary structural analysis program (SAP, ADINA or NASTRAN, etc.). In this paper, this expert system produces format of the analysis model data, which are used in MSC/NASTRAN. The main discussions included in the paper are introduction of the tower crane and structural analysis, composition of the design expert system for tower crane and structural analysis using the expert system.

  • PDF

Vibration Characteristics of the Tower Structure of a 750kW Wind Turbine Generator (750kW 풍력발전기 타워 구조의 진동 특성)

  • Kim, Seokhyun;Nam, Y.S.;Eun, Sungyoung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.2 s.95
    • /
    • pp.219-224
    • /
    • 2005
  • Vibration response of the tower structure of a 750kW wind turbine (W/T) generator is investigated by measurement and analysis. Acceleration response of the W/T tower under various operation condition is monitored in real time by the vibration monitoring system using LabVIEW. Resonance state of the tower structure is diagnosed in the operating speed range. Resonance frequency range of the test model is investigated with the wind speed data of the test site. To predict the tower resonance frequency, tower is modeled as an equivalent beam with a lumped mass and Rayleigh energy method is applied. Calculated tower bending frequency is in good agreement with the measured value and the result shows that the simplified model can be used in the design stage of the W/T tower.

Operational modal analysis for Canton Tower

  • Niu, Yan;Kraemer, Peter;Fritzen, Claus-Peter
    • Smart Structures and Systems
    • /
    • v.10 no.4_5
    • /
    • pp.393-410
    • /
    • 2012
  • The 610 m high Canton Tower (formerly named Guangzhou New Television Tower) is currently considered as a benchmark problem for structural health monitoring (SHM) of high-rise slender structures. In the benchmark study task I, a set of 24-hour ambient vibration measurement data has been available for the output-only system identification study. In this paper, the vector autoregressive models (ARV) method is adopted in the operational modal analysis (OMA) for this TV tower. The identified natural frequencies, damping ratios and mode shapes are presented and compared with the available results from some other research groups which used different methods, e.g., the data-driven stochastic subspace identification (SSI-DATA) method, the enhanced frequency domain decomposition (EFDD) algorithm, and an improved modal identification method based on NExT-ERA technique. Furthermore, the environmental effects on the estimated modal parameters are also discussed.

Analysis of the Effect of Met Tower Shadow using Computational Fluid Dynamics (전산유체역학을 이용한 풍황탑 차폐효과 해석)

  • Kim, Taesung;Rhee, Huinam;Kim, Hyun-Goo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.35.1-35.1
    • /
    • 2011
  • When the wind speed is measured by the met-mast sensor it is distorted due to the shadow effect of tower. In this paper the tower shadow effect is analyzed by a computational fluid dynamics code. First three dimensional modeling and flow analysis of the met-mast system were performed. The results were compared with the available experimental wind-tunnel test data to confirm the validity of the meshes and turbulence model. Two-dimensional model was then developed based on the three-dimensional works and experimental data. 2D analysis for various Reynolds numbers and turbulence strengths were then performed to establish the tower shadow effect database, which can be utilized as correction factors for the measured wind energy.

  • PDF

A study on the analyzing of uncertainty for actual evapotranspiration: flux tower, satellite-based and reanalysis based dataset (실제증발산 자료의 불확실성 파악에 관한 연구: flux tower, 인공위성 및 재분석자료)

  • Baik, Jongjin;Jeong, Jaehwan;Park, Jongmin;Choi, Minha
    • Journal of Korea Water Resources Association
    • /
    • v.52 no.1
    • /
    • pp.11-19
    • /
    • 2019
  • In this study, the actual evapotranspiration products of Global Land Data Assimilation System (GLDAS), Global Land Evaporation Amsterdam Model (GLEAM) and MOD16, which are satellite- and reanalysis-based dataset, were validated at the flux tower sites (i.e., CFK and SMK) managed by Korea Institute of Hydrological Survey, and the uncertainty and correlation analysis were conducted using Triple Collocation (TC) method. The result of validation with the flux tower showed better agreement in the order of GLEAM> GLDAS>MOD16. At the result of three combinations (S1: flux tower vs. GLDAS vs. MOD16, S2: flux tower vs. GLDAS vs. GLEAM, S3: flux tower vs. GLEAM vs. MOD16), the order of best to worst is GLEAM, GLDAS, MOD16, and flux tower for CFK (GLDAS> GLEAM>MOD16>flux tower for SMK). Since the error variance and correlation coefficients of the flux tower show relatively worse performance in TC analysis than the other products, By applying TC method to three products (GLDAS vs. GLEAM vs. MOD16), the uncertainty of each dataset were evaluated at the Korean Peninsula, As a results, the GLDAS and GLEAM performed reasonable performance (low error variance and high correlation coefficient), whereas results of MOD16 showed high error variance and low correlation coefficient at the cropland.

Vibration Characteristics of the Tower Structures of Wind Turbine Generators (풍력발전기 타워 구조의 진동 특성)

  • Kim, Seock-Hyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.49-59
    • /
    • 2009
  • Vibrations of the tower structures of 750kW and 6kW wind turbines(WT) are investigated by measurement and analysis. Acceleration responses of the WT towers under various operation condition are monitored in real time by the remote monitoring system using LabVIEW. Using the monitoring system, resonance condition of the tower structures is diagnosed with the wind speed data within the operating speed range. To predict the tower resonance frequency, 750 kW tower is modeled as an equivalent beam with a lumped mass and Rayleigh energy method is applied. For 6 kW WT, Rayleigh-Ritz analysis is carried out on the tower-cable coupled system. Calculated tower bending frequency is in good agreement with the measured value. Using the analysis model, parametric study is available in order to prevent the severe resonance.

  • PDF

A Numerical Study on the Performance Analysis of the Plume Abatement NWD Cooling Tower (백연 방지를 위한 NWD냉각탑의 성능해석에 관한 수치해석적 연구)

  • 최창혁;최영기;소헌영
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.11
    • /
    • pp.1049-1058
    • /
    • 2001
  • The performance and design analysis for a NWD cooling tower using a combined wet and dry type fill are numerically investigated and compared with the experimental results. The Stoecker's method is applied to the wet section and LMTD or NTU-Effectiveness method to the wet and dry sections. The efficiency ratio of the NWD cooling tower to a wet type crossflow cooling tower is 59.34%. The predicted result shows a good agreement with the experimental data within 1.4% error. Plume abatement is far better with a NWD cooling tower than a counterflow cooling tower. It costs less than a conventional wet/dry tower because the finned exchanger is eliminated. This method also leaves out complexity in structure and Intricacy in operation.

  • PDF

A Study on the relative Efficiency of ATC Towers in Domestic Airports (국내공항 관제탑의 상대적 효율성에 관한 연구)

  • Kim, D.H.
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.11 no.2
    • /
    • pp.59-77
    • /
    • 2003
  • Air Traffic Control Tower is one of the most important units in Airport operation. It provides services related to safe and efficient traffic flows that control aircraft on the ground maneuvering area and terminal airspace. Also It is responsible for managing of ground operators. The major objective of this study is to evaluates relative efficiency of ATC towers in Domestic airports using data envelopment analysis so that it helps the ATC authority to improve the tower efficiency, to decide the level of benchmarking target and to establish the best alternative. The results of this study are the following; First, as a result of analysis for the potential improvement, it has analysed that the common problems of each ATC tower are to increase its number of flight and to reduce its number of runway followed by airside area, the number of air traffic controller and the number of stand. Second, it has shown that the each tower in RKPC(8), RKPT(5), RKPK(l) and RKSS(l) are used as the reference set. Especially, the tower in RKPC analyzed as a relatively efficient unit is the most main target for the towers in RKTU, RKTH, RKPS and RKTY to do bench marking and to set up the strategy for improving relative efficiency of the tower. Third, tower is actually not able to control the input and output data in this study except the number of controller, so that ATC authority is recommended to improve inefficiency of the towers through handling the number of controller.

  • PDF

Online automatic structural health assessment of the Shanghai Tower

  • Zhang, Qilin;Tang, Xiaoxiang;Wu, Jie;Yang, Bin
    • Smart Structures and Systems
    • /
    • v.24 no.3
    • /
    • pp.319-332
    • /
    • 2019
  • Structural health monitoring (SHM) is of great importance to super high-rise buildings. The Shanghai Tower is currently the tallest building in China, and a complete SHM system was simultaneously constructed at the beginning of the construction of the tower. Due to the variety of sensor types and the large number of measurement points in the SHM system, an online automatic structural health assessment method with few computations and no manual intervention is needed. This paper introduces a structural health assessment method for the Shanghai Tower that uses the coefficients of an autoregressive (AR) time series model as structural state indicators. An analysis of collected data indicates that the coefficients of the AR model are affected by environmental factors, and the principal component analysis method is used to remove the influence of environmental factors. Finally, the control chart method is used to track the changes in structural state indicators, and a plan for online automatic structure health state evaluation is proposed. This method is applied to long-term acceleration and inclination data from the Shanghai Tower and successfully identifies the changes in the structural state. Overall, the structural state indicators of the Shanghai Tower are stable, and the structure is in a healthy state.